Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹46.1 L+₹4.2 L (10.1%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹49.4 L+₹7.5 L (18.0%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹50.0 L+₹8.1 L (19.4%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L4 | Rejected-Finance Not the lowest bidder |
Tender Value
₹39.7 L
EMD Value
₹79,400
Closing Date
25 Dec 2021, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
REPAIR AND MAINTENANCE OF DG SETS OF DIFFERENT LOCATIONS INCLUDING REPAIR AND MAINT OF AMF AND OTHER MISC WORK AND REPAIR/REPLACEMENT OF STREET LIGHT FITTINGS, CONTROL PANELS, POLES, LT UG CABLE AT BARRACKPORE UNDER GE BARRACKPORE
2021_MES_490214_1
8596/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹79,400
Yes
29 Jan 2022
24 Nov 2021
27 Dec 2021
24 Nov 2021
25 Dec 2021
9 Dec 2021
Amount
Carryout periodical routine maintenance consisting of checking, Inspection, Maintenance, and servicing complete including replacement of unserviceable parts of the DG set comprising of Engine/Alternator/Control Panel/AMF panel, attending breakdown and testing of DG Set complete, i.e. engine, Alternator etc for efficient functioning including provision of all consumables items like cotton , waste cloth , kerosine oil etc. Maintenance will be carried out for various capacity of DG sets here-in -after complete all as specified and directed. Note: (i) Spare parts shall be measured and paid separately under respective items as shown below. (ii) Labour charges for dismantling / Taking down and replacement /refixing of new spare parts as when required as deemed to be included in unit rate quoted.
380 KVA DG , MAKE : KIRLOSKAR
320 KVA DG , MAKE : KIRLOSKAR
200 KVA DG, MAKE : KIRLOSKAR
125 KVA DG, MAKE : KIRLOSKAR
100 KVA DG, MAKE : KIRLOSKAR
82.5 KVA DG, MAKE : KIRLOSKAR
70 KVA DG, MAKE : KIRLOSKAR
63 KVA DG, MAKE : KIRLOSKAR
40 KVA DG, MAKE : KIRLOSKAR
35 KVA DG, MAKE : KIRLOSKAR
30 KVA DG, MAKE : KIRLOSKAR
5 KVA DG, MAKE : Kirloskar
NOTE FOR ITEM NO.1 MONTHLY INSPECTION AND PREVENTIVE MAINTENANCE Contractor shall provide qualified trained service engineer from OEM/Authorised by OEM as refered item No 1 above to visit at site with material and labour , testing equipment to check / inspection and routine maintenance of the following:- (a) DG set servicing (B-check, C-check) (b) DG set Maintenance/Health checkup. (c) Control Panel/APFC Panel/Alternator troubleshooting only (d) Replacement of avr, water pump, starter motor, charging alternator, Fuel, coolant & lube oil hose, solenoid as per requirement. (e) Check lube oil level and conditioning of lube oil, top up/refill if required. (f) The oil filters shall be replaced whenever oil is changed. (g) The air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required. (h) Check functioning of alternator. (j) Engine safety viz. high water temperature gauge, oil pressure gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/ replaced if required. (k) Coolant level and conditioning of coolant shall be checked and refilled if required. (l) Check fan and alternator drive belts and tightened if required. (m) The governor shall be checked and tuned for proper functioning (n) Check for leaks if any and shall be rectified. (o) Checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations
Supply only following spare parts with confirming to the existing unserviceable parts for DG set of capacity 320 / 380 KVA complete all as specified and directed:-
Fuel Filter with gasket and washer
O Ring - L.O.PUMP
Oil Filter with gasket and washer
Belt V Section (BX58-Pitch Length 1520)
V Warapped Belt, SPB AR 1170 (Set of 3 Nos)
V Wrapped Belt SPB AR 1230 (Set of 3 Nos)
Temperature thermostat
Generator control unit
Air filter with gasket and washer
Air pipe (DV8) from turbo compressor out to CAC
Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete.
Supply only following spare parts with confirming to the existing unserviceable parts for DG set of capacity 200 KVA complete all as specified and directed:-
Oil filter with gasket and washer
Poly V Belt (4PK-1570)
Poly V Belt (8PK:983)
Air Filter with gasket and washer
Fuel filter with gasket and washer
Temperature thermostat
Set of copper washers for 6SL 1500 TA
Generator control unit
Bracket for fuel filter
Controller for AMF Panel
Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete
Supply only following spare parts with confirming to the existing unserviceable parts for DG set of capacity 100KVA to 125 KVA complete all as specified and directed:-
Fuel Filter with gasket and washer
O Ring - L.O.PUMP
V belt (XPA 1345) Raw Eeged cogged-(FENNER/HILTON)
Poly V Belt
Dismantling the nozzle and complete servicing, re-assemble and testing the same.
Air filter with gasket and washer
Oil filter with gasket and washer
Calibration of fuel injection pump including minor repair and servicing of injector nozzles
Supply only following spare parts with confirming to the existing unserviceable parts for DG set of capacity 40 KVA to 82.5 KVA complete all as specified and directed:-
Oil filter with gasket and washer
Fuel filter with gasket and washer
Air filter with gasket and washer
On delay timer
Gasket for cylinder head, 1.10mm thick,
Thermostat element (74 DEG) - WTIL No.DEV358,
Fuel pipe -fuel filter to fuel pump (HA4 BS III),
V Belt (XPA 1345) Raw edged cogged--(FENNER/HILTON),
Water pump and fan pulley (Poly V belt)-120 PCD,
HOSE (Radiator to water pump pipe (45X45X130L),
Connector assembly for control panel with KG934 unit
Generator control unit KG934 Level
Engine wiring harness S/F KG934 unit (pump side control panel)
Calibration of fuel injection pump including minor repair and servicing of injector nozzles
Controller for AMF Panel
Supply only following spare parts with confirming to the existing unserviceable parts for DG set of capacity 5 KVA to 35 KVA complete all as specified and directed:-
Air Filter with gasket and washer
Fuel Filter with gasket and washer
Oil Filter with gasket and washer
On delay timer
V Belt (AVX 101500) SPZ
Gasket for rocker cover high temperature application
Generator control unit
Safety element for air cleaner
Fuel pump mounted stop solenoid
Fuel pipe (7.5, 14 x 14B, 700 WB)-
Calibration of fuel injection pump including minor repair and servicing of injector nozzles
Dismantling of radiator assembly from generator set (DG Set) of following capacity and re-fixing the same after proper cleaning/repair with caustic soda and brazing the tube if any leakage is found complete all as specified and directed:-
380/320 KVA DG Set, (Make : Kirloskar)
200 KVA DG Set, (Make : Kirloskar)
125 /100KVA DG Set, (Make : Kirloskar)
82.5/70KVA DG Set, (Make : Kirloskar )
63 KVA DG Set, (Make : Greaves)
40/35 KVA DG Set, (Make : Kirloskar)
30 /5 KVA DG Set, (Make : Greaves)
Disconnecting the self starter (12V) from the engine body and dismantling the same for checking and identification of faulty spares and reassembling the same after replacement / renewal of the following spares, if required, including refixing to its original position complete all as specified and directed. (NOTE:- Spares required to be replaced shall be measured and paid separately under respective items here as under)
Supply only the following spares for fixing in repair against the faulty self starter (12V) complete all as specified and directed:-
Supply only Solenoid switch (Make : LUCAS TVS)
Supply only Carbon Brush (Make : LUCAS TVS)
Supply only Armature Field Coil (Make : LUCAS TVS)
Supply only armature Bush set complete (Make : LUCAS TVS)
Supply only Self armature coil (Make : LUCAS TVS)
Disconnecting the self starter (24V) from the engine body and dismantling the same for checking and identification of faulty spares and reassembling the same after replacement/renewal of the following spares, if required, including refixing to its original position complete all as specified and directed (NOTE:- Spares required to be replaced shall be measured and paid separately under respective items here as under)
Supply only the following spares for fixing in repair against the faulty self starter (24V) complete all as specified and directed:-
Supply only Solenoid switch (Make : LUCAS TVS)
Supply only Carbon Brush (Make : LUCAS TVS)
Supply only Armature Field Coil (Make : LUCAS TVS)
Supply only armature Bush set complete (Make : LUCAS TVS)
Supply only Self armature coil (Make : LUCAS TVS)
S&F for automatic voltage regulator 12 Volt of the following capacity DG set after and including taking down old unserviceable one complete all as specified and directed:- (Make :- Kirloskar / MRI / Crompton Greaves)
12 Volt, suitable for 5 to 30 KVA DG Set,
12 Volt, suitable for 35 to 40 KVA DG Set,
12 Volt, suitable for 63 to 82.5 KVA DG Set,
12 Volt, suitable for 100 to 125 KVA DG Set,
S&F for automatic voltage regulator, 24 Volt, suitable for 320 & 380 KVA DG Set after and including taking down old unserviceable one complete all as specified and directed. (Make :- Kirloskar / MRI / Crompton Greaves as approved)
S&F for Automatic voltage regulator, 24 Volt, suitable for 200 KVA DG Set after and including taking down old unserviceable one complete all as specified & directed. (Make :- Kirloskar / MRI / Crompton Greaves as approved)
S&F power contactor assembly 25 Amp, 3 pole 415 volt suitable for 63 KVA DG Set after and including taking down old unserviceable one complete all as specified & directed. (Make : ABB/Schinder/Havells/L&T/C&S as approved)
S&F for current transformer tap wound, ring type rated burden 5 VA, for ammeter, of ratio 250/5 after and including taking down old unserviceable one complete all as specified & directed. (Make : Kappa/AE/L&T/Rishabh as approved)
S&F for indicator lamp LED type, 220 volt AC (RED/YELLOW/BLUE) for each Phase after and including taking down old unserviceable one complete all as specified and directed. (Make: L&T/RAAS/SIEMENS as approved)
S&F for lead acid batteries including accessories like terminal clamps, copper cable of required size and length, petroleum jelly and battery initial charging of the following after and including taking down old unserviceable one complete all as specified and directed.:- (Make Exide/Amron as approved) (Note:-Old battery will be deposited to the MES Store Yard of AGE E/M Barrackpore)
12 Volts, 100 AH, 25 plates , Make Exide/Luminous /Amaron
12 Volts, 180 AH, 25 plates , Make Exide/Luminous /Amaron
12 Volts, 130 AH, 25 plates , Make Exide/Luminous /Amaron
Supply only Battery charger 10 A, 12 Volt DC complete all as specified and directed. (Make : NHP as approved)
Supply only Battery charger 10 A, 24 Volt DC complete all as specified and directed. (Make : NHP as approved)
S&F for DC Relay Board of AMF panel of various capacity of DG set complete after and including taking down old unserviceable one complete all as specified and directed.
Supply and filling of Coolant suitable for DG set complete all as specified and directed. (Make : CASTROL / SERVO / PUROKOOL / K-Kool as approved)
Supply and pouring distilled water for battery and radiator complete all as specified and directed.
Supply only BATTERY CABLE ASSEMBLY (FOR -VE & +VE) for connection of battery to self with copper Lugs, copper cable and copper connector of battery as per existing size for both terminal complete all as specified and directed.
Supplying and laying PVC insulated, armoured, heavy duty electric control cable with copper conductor, 1100 volts grade, cross sectional area 2.50 sqmm 8 core after and including taking down old unserviceable one complete all as specified and directed. (Make: Havells/Plaza as approved)
S&F for 3 Phase 415 V , AC, 50 Hz (R,Y,B &N) DIGITAL LINE VOLTAGE MONITOR after and including taking down old unserviceable one complete all as specified and directed. (MAKE- PROTON MODEL PR-07 or equivalent as approved)
S&F for oil pressure Sensors including taking down old unserviceable one after and including taking down old unserviceable one complete all as specified and directed.
S&F for change over switch (SS Enclosure) complete with of capacity 200 Amp, 415 Volt, 4 pole, 50 HZ after and including taking down old unserviceable one complete all as specified and directed. Make : Havells Cat No IHCNFE0200 or equivalent of Legrand/L&T/ABB as approved)
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised steel earth strip of size 32 x 6mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed . (Galvanised strip upto 7.5m including testing consider in this item).
General servicing and overhauling for existing Water Treatment Plant & RO System of capacity 1000 Ltr with and including unloading of media from the shells of Iron Removal Filter & Activated Carbon Filter, Cleaning of the shells as per direction and supply and fixing of following defective spare parts after and including taking out of old unserviceable defective parts complete all as specified and directed. (Note: Spares will be measured and paid as "Supply" only separately under respective items of BOQ)
Supply only new charge of Media (Zeofil & Gravel) for IRP
Supply only Activated Carbon for Activated carbon Filter
Supply only Tool for opening Micron Filter
Supply only 20" x 2.5 " dia Micron Filter Cartridge
Supply only RO Membrane (4040)
Supply only Pen type TDS Meter
Supply only Antiscalant
Supply only 3.0 core, 1.5 sqmm PVC sheathed, flexible, multistranded copper conductor cable, 1100Volts grade complete all as specified and directed.
Supply only PVC conduit pipe, 20 mm dia medium grade, ISI marked complete all as specified and directed.
Supply only MCB, SP, 6 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
Supply only MCB, SPN, 40 to 63 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
Supply only MCB, TPN, 40 to 63 Amps , 'C' series, 415 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
Supply only 25 mm dia (medium grade) GI house service bracket (hook type) 1.2m long with bends, mild steel hook and stay or guy complete all as specified and directed.
Supply only 40 mm dia (medium grade) GI house service bracket (hook type) of 1.2m long with bends, mild steel hook and stay or guy complete all as specified and directed.
Supply only fabricated flat iron MS clamps of any size as required including necessary holes, nuts, bolt and washers etc and bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated including of two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Supply only LED electronic driver of capacity 20 watt to 36 watt, 240 Volts, 50 Hz suitable for wall mounted and post top lanterns as per existing complete all as specified and directed.
Supply only LED electronic driver of capacity 40 watt to 60 watt, 240 Volts, 50 Hz suitable for street lights as per existing complete all as specified and directed.
Supply only LED electronic driver of capacity 70 watt to 100 watt, 240 Volts, 50 Hz suitable for street/security lights as per existing complete all as specified and directed.
Supply only LED electronic driver of capacity 120 watt to 150 watt, 240 Volts, 50 Hz complete as existing per complete all as specified and directed.
Supply only LED electronic driver of capacity 200 watt to 250 watt, 240 Volts, 50 Hz complete as per existing complete all as specified and directed.
Supply only LED electronic strip for rating 60 watt to 90 watt, 240 Volts, 50 Hz fittings suitable for Street lights and security lights as per existing complete all as specified and directed.
Supply only LED electronic strip for rating for 100 watt to 150 watt, 240 Volts, 50 Hz fittings suitable for street light and flood lights as per existing complete all as specified and directed.
Supply only LED electronic strip for rating 200 watt to 250 watt , 240 Volts, 50 Hz fittings suitable for flood lights complete as per existing complete all as specified and directed.
Supply only surge protection device suitable for LED light fittings of 60 watt to 250 watt, upto 4 -10 KV Surge protector, 240Volts, 50Hz as per existing complete all as specified and directed.
Supply only analogue time switch (daily time switch) with suitable power contactor 32 Amps, ML-2 type, 3Phase, 415 volts complete all as specified and directed. (Make: L&T Cat No. AUTSO3ANA00 or equivalent of Legrand as approved)
M&L for re-winding of high mast 3 Phase motor, 3HP, 415 Volts, 50Hz providing suitable gauge copper wire as existing, varnishing, heating and testing including overhauling and servicing with replacing necessary accessories such as capacitor, connectors, Nylon fan blades, nuts, bolts and washers etc after and including taking out from existing position complete all as specified and directed.
S&F for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified conforming to IS- 2317/1980 type 410 SP-31 (9 metres long) complete with cast iron base plate including staying the poles in a truly vertical position till the foundations are properly set, including painting to pole (inside & outside) with two coats of aluminium paint on exposed surfaces of poles and two coat of black bituminous paint on embedded portion after and including taking down old unserviceable pole of any description after disconnection of electric supply complete all as specified and directed. (Note: Excavation, foundation concrete and coping will be measured and paid separately)
S&F for mild steel cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer after and including taking down old unserviceable one after disconnection of electric supply complete all as specified and directed.
S&F for stay assembly complete with accessories and GI stay rod of 20 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate of size 300 mm X 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x140 mm clearance of hole 25.5 mm all shown in electrical plate of SSR Part-I after and including dismantling of existing broken/unserviceable stay assembly complete all as specified and directed. (Note : Excavation and concrete work etc will be measured and paid separately)
S&F for hot press moulded SMC junction box of inner size 400mm X300mm X190mm with incoming and outgoing connector/terminals and comprising of MCB, SP, 6 Amps, 240V, 10KA, 'C' Series and including MS flat iron clamps of size 25X5mm thick -02 Nos, nuts, bolts & washers etc for fixing on PCC/Steel tubular pole/ wall surface etc after and including removing of old unserviceable item complete all as specified and directed. (Make:- Sintex Cat No. GSJB 4030 or equivalent make of Hensel as approved)
M&L for PVC conduit heavy duty of size 20mm dia from looping box to street light connector, holding in MS clamp of size 25X2 mm thick at every one mtr used in each pole 04 Nos of clamps with necessary nut, bolts and washers etc including PVC sheathed three core multistranded copper conductor cable of size 1.5 sqmm from looping box to light fittings connector after and including removing old unserviceable items complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value after and including removing old item complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised steel earth strip of size 25 x 4mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion after and including removing old item complete all as specified and directed. (Galvanised strip upto 7.5m including testing consider in this item).
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking up /down of existing unserviceable cable of any description complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking up /down of existing unserviceable cable of any description complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 2 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking up /down of existing unserviceable cable of any description complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer after and including removing of old unserviceable items complete all as specified and directed.
S&F for 1X70/72 watt LED security light fitting, with LED lamps in aluminium PDC housing, toughened glass cover with IP66 protection with minimum 4kv inbuilt surge protector and cable connection from looping box to light fitting and testing after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make:- Bajaj Cat No. BRTFG 72W LED V3/ Crompton cat No.CRP-409-70-57-SL-GL-NSG /Havells cat No.ENDURACITYLINERNEOSL70WLED757PASYBOTG as approved)
S&F for 1X90 Watt LED security light fitting in aluminium PDC housing with LED lamp toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting and testing after and including removing of old unserviceable fittings complete all as specified and directed. (Make:-Crompton Greaves cat No.CRP-404-90-57-SL-GL-NSG /Havells cat No.ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO/ Bajaj Cat No. BRTFG90WLEDIV2 as approved)
S&F for 1X200 watt LED flood light fitting with LED lamp secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP65 protection with inbuilt surge protector and cable connection from looping box to light fitting and testing after and including taking down of old unserviceable fittings complete all as specified and directed. (Make:-Crompton Greaves Cat No.LFLN-200-CDL/60-M /Havells Cat No. JETAVALOURFL200WLED757PINTNBLTG as approved)
S&F for 1X35/40 watts LED post top decorative lantern with LED lamp made in cast aluminium spigot housing with decorative opal polycarbonate diffuser and IP65 protection with suitable fixing arrangements such as lugs, glands, nuts, bolts and washers etc including necessary electric connection with suitable size copper wire after and including taking down of old unserviceable fittings complete all as specified and directed. (Make : Bajaj Model BGCS 40W LED WH /Havells cat No : CORALPT35WLED757PSYMTOPC /Crompton Greaves Cat No.LPTM-40-CDL as approved)
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 80mm dia for passing of UG cable complete all as specified and directed.
M&L for providing cement concrete (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling for poles complete all as specified and directed
M&L for providing cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed.
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil complete all as specified and directed.
Removing surplus excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points complete all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for steel tubular pole painting of any type/size/length and removing from existing pole painting by using wire brush and using with emery paper and cleaning with chemical agents after cleaning of steel tubular pole and GI brackets and cross arms etc and applying two coats of aluminium paint over a coat of red oxide primer. Upto 1.5 mtr from bottom painting works shall be carried out layer by layer of 30 cm with yellow and black paint and 15cm wide circle around the pole to be made by blue paint after black paint. Painting work shall be carried out at any height including marking of pole numbers marked with black paint over 20 cm yellow paint circle with all necessary safety equipments & tools complete all as specified and directed.
M&L for PCC pole painting of any type/size/length and removing from existing pole painting by using wire brush and using with emery paper and cleaning with chemical agents after cleaning of PCC pole and GI brackets and cross arms and applying two coats of cement based paint over a coat of primer on pole and two coats of aluminium paint over a coat of red oxide primer on steel surfaces. Upto 1.2 mtr from bottom painting work shall be carried out layer by layer of 30 cm with yellow and black paint. Painting work shall be carried out at any height and including marking of pole numbers as directed with all necessary safety equipments & tools complete all as specified and directed.
M&L for tree branches/vegetation cutting around the LT/HT lines and installations from line conductor to tree distance up to 4 mtrs and cutted wood pieces/vegetation materials disposal upto a distance not exceeding 100 mtr where indicated and including providing necessary safety eqpts & cutting tools, ladders etc will be contractors own arrangement and complete all as specified and directed. (Note:- quoted rate shall be of the following:- (1) Necessary safety measures will be fully responsible by tenderer (2) Due care shall be taken during tree branches, so that OH line should not be damaged. If damaged the same shall be rectified by the contractor without any extra cost.)
NANDY ENTERPRISE
S..S. ELECTRIC CO.
M/S H.P Singha
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .