Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC 00 CHAH KATHAUTI CHAH KATHAUTI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹42.8 L+₹89,407.24 (2.13%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹44.9 L+₹3.0 L (7.22%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹45.9 L+₹4.0 L (9.48%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹46.5 L+₹4.6 L (11.0%)Rejected-Finance AIR FORCE ROAD NEAR BRIDGE OPP KHETIWADI RAJIV NAGAR JAMNAGAR 361002 | JAMNAGAR | JAMNAGAR | GUJARAT | 361002 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹41.8 L
EMD Value
₹83,500
Closing Date
29 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
ADDN ALTN TO BLDG No P 160 AND IMPROVEMENT TO SEWAGE LINES IN CERTAIN LOCATIONS OF MARRIED ACCN AND FEW SANCTIONED WORKS AT VARIOUS LOCATIONS AT VALSURA UNDER GE I NAVY JAMNAGAR
2021_MES_474569_1
8549
Open Tender
Civil Works - Others
Item Rate
180 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹83,500
Yes
1 Jan 2022
11 Sept 2021
1 Oct 2021
11 Sept 2021
29 Sept 2021
24 Sept 2021
11 Sept 2021 - 23 Sept 2021
60 days
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etcand removal of entire debris as ordered outside MD land complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of cement concrete of any description not other wise specified and provided etc complete and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of reinforced cement concrete of any description and in any position including removal of entire debris as ordered outside MD land complete all as directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chaj-jas and similar sus-pended work (reinforcement cut as required to facilitate demolition) including removal of entire debris as ordered outside MD land complete all as directed.
Dismantling wrough iron or mild steel work of any description not other wise provided for and stacking at site complete all as directed.
Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MD land complete all as directed.
Taking down chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from frame) and stacking at site where directed.
All as per item 8 here-in-above but exceeding 1.5 Sqm but not exceeding 4 Sqm each
Dismantling fencing wire mesh any type etc complete all as specified.
Dismantling post or struts (wood, steel or RCC) any section, including taking out embedded portion in concrete and making good the disturbed ground complete all as specified and as directed.
Demolition and breaking up 150 mm internal dia drain pipes (PVC, cast iron, Salt glazed ware, AC or Reinforced concrete) set in cement mortar including removal and deositing of debris to a distance not exc 50 mts and depositing where directed.
Excavation in trenches and not exe. 1.5 m wide and not exceeding 1.5 m in depth for foundation of drain, man hole, stay etc. not exe. 10 Sq. m on plan and getting out in soft / loose soil.
Excavation over areas, n exc 1.5 m deep n. exc 1.50 mtr wide and getting out in soft/loose soil.
Excavation in trenches and not exe. 1.5 m wide and not exceeding 1.5 m depth for foundation of drain, man hole,laying of cables etc. not exe. 10 Sq. m on plan and getting out in soft / disintegrated rock.
All same as per item No 15 here-in-above but depth exceeding 1.5 m but not exceeding 3.0 m -do-
M&L hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance exceeding 500 mts but not exceeding 1.0 km and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L for PCC 1:3:6, type C2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
M&L for plain cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate as in surface channel of drains benching finished the top of benching even and smooth using extra cement including necessary form work complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B1 using 20 mm graded granite stone aggregate as in cast in situ in cills and other similar bands, plinth courses, coping, bed plates including necessary form work , weathering slightly rounded, chamfered angles and throating complete all as specified and directed.
M&L for Precast Reinforced cement concrete M-30 Design Mix ( 20 mm aggregate stone aggregate) as in cover slab to Man holes set and jointed in cement mortar 1:6 complete all as directed (Note: Reinforcement shall be measured and paid seperately.)
M&L Reinforced Cement Concrete Type M-30 (using 20 mm graded granite stone aggregate) in Columns, piers, posts and struts complete all as specified and as directed by Engr-in-Charge.
M&L RCC M-30 design mix (using 20mm graded aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as directed.
M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified.
Supply only Integral Water Proofing Compound (ISI Marked) of Make : CICO, Acco Proof, Impermo, Aqua flex as approved.
M&L for Extra for forming fair finishing drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered stopped ends etc complete all as specified and directed.
Cutting holes in brick works of size not exc half brick built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required including making good as per its original specification with out any extra cost complete all as directed.
Cutting chases in brick/ stone wall, pinning in, making good to facing where required and plastering in CM 1:4 to ends of edges of landing, steps, cills, lintels etc and cutting chases not exceeding 10 cm girth for concealed water tubing and making good cutting as per its original specfication complete all as directed.
S&F Second class hard wood factory made kiln - seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as directed.
S&F 35 mm thick second class hard wood factory made glazed and skeleton shutter open rebated and prepared to receive glass, guage etc edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (a) supplied and fitted to chowkats.
S&F 30 mm thick Flush shutter with solid core construction with block board core and ply wood face panels commercial type on both sides fixed in position complete all as directed
S&F 19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balacing white lamination, fixed with screws to timber frame work including external teak wood lipping, 6mm thick fixed with nails complete all as directed.
S&F fibre glass reinforced plastic (FRP) door frames of three legged of cross section 90x45 mm having single rebate 32x15 mm to receive shutter of 30 mm thickness. The laminate door frame moulded with fire retardant grade unsaturated polyster resin and chopped mat. Door frame laminate of 2 mm thick and filled with suitable wooden block in all three legs. The frame shall be covered with fibre glass from all sides. Mild steel stay shall be provided at the bottom to steady the frame.
S&F 30 mm thick fibre glass reinforced plastic (FRP) paneled door shutter made with fire retardant grade unsaturated polyester resin moulded to 3 mm thick FRP laminated for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5 mm thick FRP laminated for panels.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frames and shutter for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as directed.
S&F powder coated anodised aluminium window and ventilator shutter, side hung type without sash or sliding type, aluminium sections weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no) hinges type B-21 100mm long(2 no) suitable handle (1 no) complete all as specified.
S & F 200 mm long aluminium, anodised , barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F 150 mm size aluminium alloy handles (ISI Marked) fabricated type anodised and fixed.
S & F 300 mm long aluminium alloy, anodised sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S&F 75mm door stopper of aluminium alloy body with rubber bottom fixed with screw in bottom rail of door complete as specified.
S&F XPM design aluminium alloy wire mesh, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples along with wooden beads.
S&F 6 to 8 mm dia TMT bars cut to length bent to shape required cranking including bending, hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L MS round bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending, painted with one coat of aluminium paint over a coat of primer and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed.
S&F mild steel screw bolts of 11-15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5 cm but not exceeding 10 cm long complete all as specified.
S&F rolled mild steel as in fencing post conforming to fe-290 Gde E-165 complete all as specified and as directed.
S & F rolled mild steel (Fe410-W Gde E-250 quality A) in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S & F rolled mild steel (Fe410-W Gde E-250 quality A) in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc.
Supply only MS galvanized chain link fencing (120 to 140 gms) 4mm dia and 75mm spacing and weighing not less than 2.75 kg/sqm diagonally pinned including line wire rails, straining bolts and provision of binding wire complete all as specified and as directed. Make : M/s Sachin , TATA or any approved make as approved.
Fixing only diagonally pinned fencing wire including line wire, any mesh size and type of standards, rails, straining bolts etc. including provision of binding wire complete all as directed.
S&F Steel rolling shutters of 1.25 mm thickness laths but gear operated type with bevel gear box and crank handle, without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete
Material and labour for removal of existing WPT course or any other kind of treatment surface over roof slab including plaster any thickness, PCC etc and cleaning of surface with wire brushes and water removing of unsolvent materials and depositing of the same as directed outside MoD land and provide 15 mm thick screed bed/ bedding layer in CM 1:3 mixed with Water Proofing Compound (WPC) as per manufacturer instructions, including finishing the surface fair and even on RCC roof/ parapet once bedding layer of concrete is completely dried and apply oil bound bituminous primer @ 0.30 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure as directed and finally finished the top surface with two coats of thermal resistant paint complete all as specified and as directed. Note: (i) The quoted rate is deemed to be inclusive of taking down & removal of debris , 15 mm thick 1:3 screed & complete APP treatment. (ii) WPC will be paid seperately (iii) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT (iv) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M&L for 40mm avg thick plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in levelling course to floors etc complete all as directed.
M & L for 100 mm thick plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base of floor/ path complete all as directed
M & L for 75 mm thick plain cement conctere 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection finished the surface fair and even complete all as directed.
M&L for rendering 15 mm thick in CM 1:6 on brick work/ stone work or concrete surface work finished even and smooth without using extra cement complete all as specified.
All as per item No 58 here-in-above but 10mm thick in CM 1:3 on ceiling,chajja,roof projection etc.
M & L for rendering cement plaster in two coats, 8mm thick in CM 1:4 using WPC over 12mm thick in CM 1:6 on external surfaces of stone masonary walls finished even and smooth without using extra cement
M & L non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified.
M & L non-skid jointless coloured ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified.
All same as per item No 62 here-in-above but as in skiting / verticals surfaces, set and jointed in neat cement slurry including 10 mm thick back coat in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all directed.
M&L glazed ceramic designer tiles any shade or pattern as approved of size 600x300x7 mm thick, on verticals surfaces, set and jointed in neat cement slurry including 10 mm thick back coat in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all directed. (Note for item Nos 61 & 64 : i) Quoted rate is deemed to be inclusive of cement screed. ii) Shade / pattern / Colour of tiles shall be got appproved before procurement).
M&L 16 to 18 mm thick granite slab (Jet Black) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms etc laid over and including 15 mm thick screed bed in cement mortar 1:6 and set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified.
M&L M-35 grade, 60 mm thick machine pressed precast cement concrete interlocking paver blocks any shape and size with grey cement and pigment confirming to IS: 15658-2006, laid over and including 50 mm thick compacted sand cushion complete complete all as specified.(Note ; Quoted rate is deemed to be inclusive of 50 mm thick compacted sand cushoning).
M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with WPC as per manufacturer instruction , and finished the surface fair and even complete all as specified and directed. (Note : WPC shall be measured and paid separately).
S&F 4mm thick sheet glass, ordinary quality and glazing fixed to aluminium sections exceeding 0.5 Sqm in each pane complete all as directed.
Three coats of white wash on newly plastered surface of ceiling after necessary preparation of surface complete all as directed.
M&L preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or unplastered surfaces) and applying three coat of white wash of white wash complete all as directed.
M&L preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 3 mm thick white cement based wall care birla putty complete all as specified.
M&L complete removal of existing treatment and preparing old plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer over a coat of 3mm thick white cement based wall care putty complete all as specified.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L for preparation of old painted surfaces by complete removing the existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M & L Two coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surface complete all as directed.
M & L one coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over not exceeding 10 cm in width or girth when unconnected with other painting or when painted in a different tint including necessary preparation of new steel surface complete all as directed.
M & L for 15 mm bore steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors in repairs complete all as directed.
M & L for 20 mm bore steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors in repairs complete all as directed.
M & L for 25 mm bore steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors in repairs complete all as directed.
S&F in repairs stop/ gate valve, cast copper alloy screwed down high pressure with cruch or butterfly handle, screwed both end for iron pipe or for unions and fixed of size 25 mm dia complete all as specified. Make: Leader/ Zoloto/ Gem/ SEIKO/ Sant
Cutting of existing DI / GI pipe of 40mm dia in position for inserting of new pipe all as specified and as directed.
S&F in repairs 15 mm bore bib taps, fancy type long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as directed. Make: Prayag 6509 or equvalent make approved by GE.
S&F in repairs stop valves for 15 mm bore of pipe cast copper alloy, screwed down, high pre-ssure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified. Make: Prayag Cat No. 6510 or equivalent in approved make.
S&F new sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or cutting and fixing into granite platform including fixing cantilever brackets and connecting union to pipe overall size 915 x 460 mm bowl size 410mm x 330mm x 160mm complete all as directed .Make : Jayna Cat No. SBSD (05) or equivalent of Prayag, Nirali, Franke, Parryware, Neelkanth, Diamond
S&F 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, fixed to wall, ceilings or in floors etc. complete as directed.
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints laid in floors complete all as directed.
S&F in repair 75 mm size PVC (SWR) floor trap with grating including jonting the same with solvent cement complete all as directed.
S&F 550 mm X 400 mm size white flat back vitreous china wash hand basin including chromium plated pillar tap (Make: Prayag Cat No. 6502) cap stain head suitable for 15 mm bore of pipe , PVC connection 15 mm dia 45 cm long with chromium plated nuts and bolts and suitable washers, PVC waste 32 bore CP waste coupling chain and plug , porcelain stopper including CI bracket fixed in repair complete all as diirected.
S & F in repairs Vitreous china squatting pan "Orissa pattern" long pan of size 580 x 440 mm white with integral foot rest but (excluding flushing cistern and flush pipe ) including connection etc including setting the trap and pan in lime concrete ( 1 lime 2 sand or surki as ordered and 5 aggregrate ) , min. 150 mm thick alround and finished just below level of rim of pan to floor finish complete all as directed.
S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as directed.
S&F in repairs PVC connection 15mm bore and 45cm long with two Nos of brass check nuts and washers complete all as directed.
S&F new 1000 litres capacity rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover including PVC float valve high pressure suitable for 25 mm bore of pipe with polythene float, fixture hoisted and fixed in position where ordered and making necessary connection and testing complete all as directed. Make: Sintex/ Polycon/ Rotex/ Infra/ Ashish Plast/ Arolex
Dismantling of existing any type & any capacity water storage tank fixed in any description and stacking at site and S&F new 1000 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover including PVC float valve high pressure suitable for 20 mm bore of pipe with polythene float, fixture hoisted and fixed in position where ordered and making necessary connection and testing complete all as directed.
M & L for concrete bed in PCC 1:3:6 type C2 using 40 mm graded stone aggregrate to 150 mm bore SWG / Hume pipe including packing and haunching completely surrondings of the pipe after they are laid and tested complete all as specified and directed. .
All same as per item No 94 here-in-above but 200 mm bore pipe -do-
M&L for Reinforced concrete pipe 150mm bore Class NP2 (ISI Marked ) alongwith collar laid to slope in trenches over PCC bed & jointed in cement mortar 1:3 and tested on completion complete all as specified and directed.
All as per item No 96 here-in - above but 200 mm bore -do-
M&L for cutting into existing manhole for connecting 200 mm bore (internal dia ) new drain pipe, making good to pipe and rendering, cuttingout existing benching for forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded granite stone aggregrate, smooth finished and reforming benching as required complete all as specified and directed.
Chipping / dismantling of loose damaged concrete removed carefully by using mechanically concrete up to good parent concrete to expose the existing reinforcement (Direct hammering should be avoided . (avg thickness of 50-75 mm allround of lintel/ beams/columns/slab all as per the direction of Engr-in-charge.
After chiping of loose concrete the exposed surface shall be cleaned to remove any loose materials with wire brushes for further treatment like application of rust convertor (Rebaklens RR Fosroc/Conmix RR) . Apply epoxy - Phenolic based anti corrosive coating (BASF make Master Emaco P130/Nitrozinc Primer of Foserock/Recon Zinc of Conimix ) over the exposed reinforcement in two coats and allow the coating to cure in air for atleast eight hours before starting further treatment. The entire concrete surface shall be applied with concrete penetrating corrosion inhibitor solution.(EPCO KP 100 Krishna Conchem) on lintel / beam/columns/slab etc. all as specified and directed.
Providing and fixing shear key using 10mm diameter TMT bars including drilling holes of 12mm diameter and 100 mm depth @ 300 mm spacing on all sides of lintel/beams/columns/slabs and providing TMT bars of same diameter of reinforcement where as reduced to less then 20% of original diameter including tack welding and grout the holes of shere key with two component epoxy resion based anchoring grout Master Flow 935 of BASF/LOK fix P of FOSROC by power gun etc.
Providing, fixing and removing of water tight shuttering (Form work) using film coated 12 mm thick ply wood sheets for micro - concreteing the lintels/beams/column/slab in line and level with proper support of avg thickness 50-75 mm all as specified and as directed. Note: The rate under this item will be for formwork as well as microconcreting specified.
TREES: Digging of pits of size 1.00x1.00x1.00 m, removal of debris, weed roots etc., refilling with good soil and cattle manure in 4:1 ratio, with provision of pesticide treatment , routing manure, watering etc as per the guidance of horiculture consultant at plantation time including supply and planting of approved saplings (Coconut, Bottle palm, Manilkara Zapota, Ashoka, Mango, guvava, Red palm etc.). Sapling should be healthy, grown up with good root system and minimum 4 feet height from ground level after plantation.
SHURBS: Digging of pits of size 0.60x0.60x0.60 m, and refilling with good soil and cattle manure in 4:1 ratio, with provision of pesticide treatment, routing manure, watering etc as per the guidance of horiculture consultant supply and planting of approved species of healthy grown up sapling with good root system minimum 2 feet from ground level (Bougain villa, Song of India, Drackenia, Ixora, Ticoma, Nirivim Red etc.)
Lawn: Loosening of soil and removal of weed roots and refiling with agricultural soil and cattle manure in the ration 4:1,Provn of ATT, Mixing,levelling and planting of deep mexican grass complete all as specified and directed.
LAWN: Planting & development of lawn mexician carpet grass including earthwork excavation by digging upto a depth of 30 cm in any type of soil and filling the same with good soil and cattle manure in 4:1 ratio, farm yard manure and fertile soil in propotion 1:2:3 with necessary pestiside treatment, routing manure, watering etc as per the guidance of horiculture consultant complete including removal of surplus soil complete all as directed.
GROUND COVER: Digging up to 0.3 m, refilling with agricultural soil and cattle manure in 4:1 ratio, with necessary pestiside treatment , routing manure , watering etc as per the guidance of horiculture consultant complete including supply and planting of healthy grown up plant material (Chandani Double, Chandani Single, Red ruhy, Erem Thirma Black, Erem Thirma Green, Acalipha, Java etc.) compete all as directed..Note for Item No Srl item No 101 to 105.00 : i) Contractor shall maintain the above items for a period of 06 (six) months from date of completion by spreading of approved pestisides, insecticides in the desired periodically, deweeding, watering and replacing dead plant with new plant etc, Contractor shall deploy minimum (01) Mali. ii) The contractor shall ensure that he is having tractor tanker, small tanks on rickshaw fitted with hose pipe etc for watering purpose and requisite equipment for spraying the medicine on plants, ploughing the earth for deweeding out unwanted frowth /grass etc in running condition throughout the period.iii) The foliager and other unwanted items shall be removed from entire site. iv) Trained gardner shall be deployed all the working days of the week except sunday and national holiday. v) Supply of pestisides, insecticides, replacment of dried/ dead plants/ grass/ trees, mixture of vermin compost, farm yard manure etc free of cost upto maintainance period. vi) In case contractor fails to maintain the saplings/ lawns etc as said above for whatso ever reasons dring the period an amount of Rs 1000/- per day shall be recoverd form the Contractor )
Taking down carefully copper/ aluminium point wiring ( Light, Fan, socket or power) complete (fittings such as switches, celling roses, pendants, regulators, sockets, DB,s) etc all as specified and directed by Engr -in - charge.
M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through including PVC concealed conduit 20mm, concealed MS box / PVC/ MS/ Cast Iron box and logic modular whtie plates of suitable as required at site with PVC insulated unsheathed stranded copper of size 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 109 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
All as per item No. 109 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 109 here-in-above, but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F Modular switch 1 way 6 Amps,1 module all as specified and direced.
S&F Modular switch 1 way 16 Amps,1 module all as specified and direced.
S&F Modular Socket 6A -2/3 pin combinaed 2 Module all as specified and directed.
S&F Modular Socket 16A -2/3 pin combinaed 2 Module all as specified and directed.
S&F Step type electronic fan regulator modular type 120W, 2 Module.
S &F ceiling rose surfaces bakelite three terminals
S&F sheet metal enclosures for DB's double door in wall / nitch when MCB's to be used Triple pole and neutral, 4 way,415 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 4 way, single door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
Supply and fix MCB TPN 40 to 63 Amp 10KA 415V 50 Hz AC Supply Make : Legrand Cat No 4086 81 to 4086 83 equivelent in ABB/ Havells/ L&T
Supply and fix MCB SPN 10 to 32 Amp 240 V 50 Hz AC Supply Make : Legrand 4086 12 to 4086 17 equivelent in ABB/ Havells/ L&T
Supply and fix MCB SP 6-20 Amp (In accordance with IS/IEC 60898-1) 240V, 50Hz, 10KA ISI marked Suitable for lighting and other domestic loads Cat No 408587 to 408593 Make: Legrand or equivelent in ABB/ Havells/ L&T
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
S&F exhaust fan, steel body AC single Phase. 230V of size 380m sweep with, blades, and frame and louvers heavy duty complete all as specified and as directed.
S&F LED Wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver 22W LED (4ft) complete all as directed. Make : Havells/ Jaquar/ Bajaj
S&F LED Post top 45W IP65 protection in spherical shape polycarbonate diffuser complete all as specified and directed by Engr-in-Charge. Make: Bajaj Cat No BGCT W4 LED WW P/No-112364 or equivalent in Wipro/ Havells/ Jaquar
Supply and fix 45 Watt LED street light fittings, High Efficiency IP 65 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate/ toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of he system shall be greater than 4000 lumens with minimum lumens as per watt 101+3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing on GI bracket of suitable size including nut bolts, 2.5 sqmm, 3 core cable and electrically connected complete all as directed. Make : Havells/ Jaquar/ Bajaj
S&F Junction box made from SMC/ FRP sheet ready made of size of 300x200x100 m having 100A Capacity RYB nad neutal aluminum busbar, MCB SP 6 A 10 kA 240V - 01 No fixed to pole/ wall with MS Clamp 25x5 mm and nut bolts etc complete all as specified and directed
Supply and lay 32mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, laid in trenches as cable protection with all fitting complete all as specified.
M&L for submain wiring with two runs of single core 4 Sqmm PCV insulated unsheathed multi-stranded copper conductor cable drawing in and including PVC rigid medium grade conduit concealed of suitable size complete including provision of 4 Sq mm copper unsheathed cable PVC insulated as earthwire connected to earth doll inclusive of al tees, bends, elbows,reducers etc all as specified and directed by Engr-in-Charge (Note : 3 runs of 4 sqmm cable and one run of PVC conduit shall be measured as one unit length)
Supply, laying, testing, XLPE insulated screened, PVC innersheathed galvanised steen strip or wire, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sq mm, 4 Core including taking down existing cable complete all as specified.
S&F in repairs earth continuity conductor or main earthing lead of Galvanised iron strip of size 32x6 mm, fixed on pole/wall from existion earth test point complete all as specified and as directed by the Engineer-in-Charge.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead GI strip 25x4 mm, 7 mtr long by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrial plate No. 3 connected or indicated including testing on completion. Including necessary excavation, earthwork, PCC pit, RCC cover, funnel with watering pipe 20 mm bore light grade, GI protection pipe 40 mm bore medium grade complete including taking out existing any type of earthing complete all as specified.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead 32x6 mm GI strip means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected or indicated including testing on completion. Incl necessary excavation, earth work, PCC pit, RCC cover, funnel with watering pipe 20mm bore light grade, GI protection pipe 40 mm bore light grade complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for Name board made out of acrylic sheet (colourful) & GI sheet frame work of size 7ftx4ftx9inch depth duly prewired & with LED lights batten 4ft 20 Watts Make Jaquar Model No. Glaze LED Batten Cat No. LGLZ01X020XC - M 04 Nos with mounting/ fixing hooks. The following lettering of size 9" in height to be written on Name board: MILITARY ENGINEER SERVICES MAIN RECEIVING STATION 11KV AGE E/M (NAVY) JAMNAGAR GE (I) NAVY JAMNAGAR
ruturajconstruction
M/s. Jayant G Rampariya
Amar Constructions
Suraj Builders
Hirachand Sunderji and co
M/s Balaji Enterprise
rahil enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .