Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | ₹17.1 L Quoted ₹18.6 L | L1 | Accepted-AOC being lowest bidder |
| 2 | L2₹24.5 L+₹5.8 L (31.3%)Rejected-Finance D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹24.5 L+₹5.8 L (31.3%) | L2 | Rejected-Finance Being Not L1 bidder |
| 3 | L3₹24.8 L+₹6.2 L (33.2%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | ₹24.8 L+₹6.2 L (33.2%) | L3 | Rejected-Finance Being Not L1 bidder |
| 4 | L4₹32.0 L+₹13.4 L (71.7%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | ₹32.0 L+₹13.4 L (71.7%) | L4 | Rejected-Finance Being Not L1 bidder |
| 5 | L5₹33.3 L+₹14.7 L (78.8%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | ₹33.3 L+₹14.7 L (78.8%) | L5 | Rejected-Finance Being Not L1 bidder |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
25 May 2024, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
SPECIAL REPAIRS / REPLACEMENT OF OLD UNSERVICEABLE BER LIFTS AT BUILDING NO. P-45 (HQ ENC) UNDER GE (U-I) VISAKHAPATNAM
2024_MES_651166_1
8634/E8
Open Tender
Electrical and Maintenance Works
Item Rate
1215 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
6 documents required · 6 mandatory
₹500
Garrison Engineer Utility-I
₹62,000
Yes
11 Jun 2024
25 Apr 2024
27 May 2024
25 Apr 2024
25 May 2024
13 May 2024
Amount
PHASE - I SCHEDULE 'A' PART-I
Design supply, install testing & commissioning of 08 passengers lift (544 Kg capacity), speed 1.5 meter per sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to serve G+ 06 upper floors i.e., with 7 stops and 7 landings with or without attendant suitable for synchronized operation automatic power operated centre opening sliding stainless steel Car and landing door with vision panel of 1800 x 350 mm, however dimension may vary as per site requirement with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex full collective automatic & manual dual controlled operation with or without attendant, centre opening doors with door drive (electric motor driven mechanism), automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified and directed by Engineer-in-Charge.(Location/Building HQENC BUILDING).
Hairline finish stainless steel on both sides of the wall inside the car, the front wall of the car should be hairline finish stainless steel, the floor of the car should be granite colour & design as approved by Accepting Officer, the COP inside the car should be full height of premium quality acrylic touch panel, Car indicator should be colour LCD display, finish stainless steel on lintel, flush mounted finish of 1.5 mm with infra-red sensors all along the height for car door with automatic rescue/leveling device (ARD) (with (+) or (-) 5 mm) with suitable batteries, Floor position digital indicators in car and all landing with call indicating lights etc including necessary joists and beams for mounting machine in the machine room including additional/alteration to existing lift well if any, all necessary civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :- [a] Fire man switch [b] Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. [c] Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. [d] Designer six sleek circular LED light fitting 5 Wattsx4 Nos in false ceiling with AC louvers to be provided in the cabin. [e] Provision of one cross flow fan suitable for recessed mounting in false ceiling [f] Provision of premium quality Granite stone slab of 18-20 mm thick as in flooring for lift car as approved by Accepting Officer over 3 mm thick aluminium chequeres sheet. [g] Nonstop button /independent operation [h] Over load warning indicator with both audio and visual type with over load protection/tripping system having relays etc and floor announcement system [j] Front landing door with full vision glass panel with stainless steel hairline finish frame operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds programmable. (Contd...)
[k] All the dimensions of lift and connected items shall be designed in conformity with IS 14665 standards and the contractor shall submit the design drawing to accepting officer for approval before commencement of work. Car size shall be in conformity with IS-3534-1976 and body to be stainless steel of 1.5 mm hairline finish with stainless steel hand rail 38 mm dia SS handrail in hairline finish. [l] Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS [m] Full length display indicator panel. [n] Instruction plate with complete details to be provided inside the cabin. [o] Continuous earthing for machine and equipments as per schedule. [p] Steel Wire rope of adequate size as per relevant IS and as per manufacturer specification. [q] Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit breaks, control panel, locks governor car operational panel, power control and trailing cables complete all as per latest IS specifications. [r] Lift design, specifications, drawings, manufacturer’s instructions shall be got approved from accepting office before placing order for procurement. [s] Main drives and controls shall be of latest, high effective and low power consumption. [t] Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. [u] Stainless steel sliding doors with front opening for all landing made of 1.5 mm SS sheet with Hair line finish with vision panel of full size 350 mm x 1800 mm, however dimensions may vary as per site requirement with toughened glass not less than 8 mm thick, car back panel (in front of entrance door panel) shall be made out of single toughened glass of thickness not less than 10 mm thick fitted seamlessly on stainless steel back panel design as approved by Accepting Officer. (Contd...)
[v] Some others technical specifications are as follows: (a) Car travel-G+6 travel approx 21 meters (b) Landing entrance- Auto door CO SS hair line finish 1.5 mm thick with 1800 X 350 mm vision panel (c) Car inner dimensions (WXD) – 1300 X1100 mm however dimensions may vary as per site (d) CLEAR ENTRANCE (WXD) – 800 X2000 mm however dimensions may vary as per site (e) Hoist way required (WXD) – 1900 X 1900 mm (f) Types of machine- Gearless to be fixed in existing machine room (g) Signals- Emergency Alarm bell up/down, direction indicators, digital position Indicator in car and landings, Audible floor hooter, emergency stop etc. (h) Gearless machine unit- Kirloskar / Montanari / Siemens (j) Ropes- USHA MARTIN (k) Controller- microprocessor/Latest technology Based- As per OEM (l) In built AC suitable for 8 passenger lift cabin with a provision for condensed water in lift well. (m) Full length display indicator panel with touch COP and touch LOP (n) Provision of CCTV and LCD / LED screen of size minimum 8” inside the car cabin.
MAKE : [a] Lifts : Kone India / Schneider India Pvt. Ltd. / Kinetic Hyundai Elevators Movement Tech Ltd. / Hitachi Lifts India Pvt. Ltd. / Mitsubishi Elevator India Pvt. Ltd. / Otis Elevator Company India Ltd. / Fujitech India Pvt. Ltd./ Johnson Lifts Pvt. Ltd. / Thyssenkrupp Elevators India Pvt. Ltd. / Omega Elevators / Escon Elevators Pvt. Ltd. / LT Elevators Pvt. Ltd. / IES Elevators Pvt. Ltd. [b] Gearless Motor : Kirloskar / Montanari / Siemens [c] Controller : As per OEM [d] Automatic Rescue Device : As per OEM [e] Over load Warning Device : As per OEM [f] Steel Wire ropes : Usha Martin [g] Cable/Wires : Havells / Gloster Cables / KEI Industries Ltd / Polycab / Asian Cables / Finolex [h] Buffer Springs : As per OEM [j] Guide Rails : Elcon / Greaves / Radicon /As per OEM [k] Drives : Fujitech / Yashikawa/ Mitsubishi / Gefran [l] Electrical & Electronic : C & S / Schneider / Telemecqunics [m] LED Light Fittings External / Internal : Philips / Havells / GE [n] ERW MS Pipes / GI Pipes / Fittings : Surya Roshni Ltd / Tata / Jindal steel / Prakash [o] MCBs / RCCB / RCBO & DB for MCBs : Legrand / L & T [Hager] / Siemens / ABB / Schneider / GE / C & S [p] Limit Switches : As per OEM [q] Brakes : As per OEM [r] Governor : As per OEM [s] Counter Weight : As per OEM [t] Battery : Exide / Amco / Amaron / Luminious
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L earth continuity conductor or main earthing lead using 32 x 6 mm galvanised iron strip, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
M&L Maintenance Free Chemical Earthing complete with 40 mm X 3000 mm Advance Chemical Earthing Pipe with [Strip in pipe Technology] with 50 KG of Backfill Compound buried directly in ground [Rocky Soil] with earth pit not less than 2.25 m deep below ground level with top edge of Plate not less than 1.50 m below normal ground level connected to existing Copper Earth Strip by means of Stainless Steel bolts, nuts, check nuts and washers all as per IS- 3043 including testing on completion complete all as specified and as directed. The earth resistance shall be measured using fall of potential method as per Para 37 of IS-3043 & combined resistance should be less than 1 Ohms. Note: The unit rate quoted shall be deemed to include for PCC [1:2:4. Type 81] Pit with RCC 1:2 4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS handle 12mm dia, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
S&F MCCB 4 pole 63, breaking capacity 16 kA, Ics = 100% Icu, thermal megnatic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 lr) including necessary modification in the panel & taking down existing MCCB complete all as specified and as directed. Make :- Legrand / L & T / Siemens / ABB / C & S / Schneider / GE / Hager
Suuply and fix TPN Sheet metal enclosure double door 4 way complete all as specified and as directed.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 50 Sqmm x 3.5 Core, laid in trenches / duct / on pole / floor / wall including taking down existing cable complete all as specified and directed. Make :- Havells / Gloster Cables / KEI Industries Ltd / Polycab / Asian Cables / Finolex
S&F on-load change over switch 100 Amp capacity, four pole, 415 volts with SS enclosure including taking down existing one complete all as specified and directed. Make :- Legrand / L & T (Hager) / Siemens / ABB / C & S / Schneider / GE
PHASE - II SCHEDULE 'A' PART-II: Comprehensive Maintenance of Passenger Lifts as Provided Under Schedule "A" / BOQ Part - I for Three Years After Successful Completion of Defects Liability Period of Work under Phase - I
M & L for Comprehensive Maintenance of Electricallay Operated Lift of 08 passenger (544 kgs Capacity), serving G+6 Floors, installed at P-45 building (HQ ENC) catered under catered under Serial Item No. 02 of BOQ / Schedule "A" Part - I for Third Year after successful completion of work under Phase-I complete and all as specified and as directed
M & L for Comprehensive Maintenance of Electricallay Operated Lift of 08 passenger (544 kgs Capacity), serving G+6 Floors, installed at P-45 building (HQ ENC) catered under catered under Serial Item No. 02 of BOQ / Schedule "A" Part - I for Fourth Year after successful completion of work under Phase-I complete and all as specified and as directed
M & L for Comprehensive Maintenance of Electricallay Operated Lift of 08 passenger (544 kgs Capacity), serving G+6 Floors, installed at P-45 building (HQ ENC) catered under catered under Serial Item No. 02 of BOQ / Schedule "A" Part - I for Fifth Year after successful completion of work under Phase-I complete and all as specified and as directed
[k] The Contractor is responsible for Insurance, EPF, ESI, Gratuity, Bonus, Labour Welfare Cess etc., as applicable and shall be paird to the Workmen as per existing Labour Rules / Acts / Regulations and rate qouted shall be deemed to be included for the same. [l] INSURANCE AND DRESS CODE: The contractor shall provide the workmen with Dark Blue Colour uniform with labels showing the Name of Firm and the Designation and "GE (Utility-I) [V]" printed on them along with protective clothing. The contractor shall also provided shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. [m] The contractor shall be responsible for all Accidents / Injuries happening to the workmen. Any accident causing Minor / Fatal Injury, Partial Disability due to any untoward incident or non-adherence to Safety and IE Regulations or fault in maintaining of Lifts System / Safety Mechanism or on account of any mishandling / wrong operation / lack of knowledge of safety precautions or on account of any circumstances beyong his/their control, the contractor shall be solely responsible for settling all claims of compensation to the deceased, failing which department will have a right to recover any sum indicated / claimed by Labour Commissioner / Court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Contractor shall provide first aid boxes to meet any emergency situations. [n] The contractor shall carryout the comprehensive maintenance of the lifts catered under subject work through the Original Equipment Manufacturer of that lift or from their accredited / authorised agencies only. The lowest bidder shall submit MoU from the Original Equipment Manufacturer of the Lift or from their accredited / authorised agencies to provide technical support, trained persons for maintenance & testing and spares before commencement of the work to GE. The spares shall be of the make as per existing or as per the OEM. [o] MINIMUM MANPOWER TO BE EMPLOYED: The contractor shall be required to employ the One Lift Mechanic per Shift of 08 Hours form 0900 Hours to 1700 Hours and shall report to Office of AGE [E/M] for day to day maintenance and efficient operation of Lifts.
INDUSTRIAL ENGINEERING SYSTEMS
Saviour Security Systems
Escon Elevators Pvt Ltd
MONITOR ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .