| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC Lowest and reasonable tender accepted as amended |
| 2 | L2₹2.0 Cr+₹12.3 L (6.74%)Rejected-Finance BETONG SHOP KHANGSAR COMPLEX NOWSHARA LEH LADAKH 194101 J K | LEH | LEH | JAMMU AND KASHMIR | 194101 | ₹2.0 Cr+₹12.3 L (6.74%) | L2 | Rejected-Finance Bid on higher side |
| 3 | L3₹2.5 Cr+₹67.8 L (37.0%)Rejected-Finance BIAMATHANG BAROO KARGIL J K | KARGIL | KARGIL | J K | ₹2.5 Cr+₹67.8 L (37.0%) | L3 | Rejected-Finance Bid on higher side |
| 4 | L4₹2.7 Cr+₹86.1 L (47.1%)Rejected-Finance PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | ₹2.7 Cr+₹86.1 L (47.1%) | L4 | Rejected-Finance Bid on higher side |
| 5 | Rejected-Technical | - | - | Rejected-Technical Tender validity not extended by the firm. |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
10 Apr 2021, 6:00 pmClosed
CE LEH ZONE
HQ CHIEF ENGINEER LEH ZONE PIN- 901 205
AUGMENTATION OF WATER SUPPLY FOR VARIOUS LOCATION AT DRASS
2020_MES_383378_2
180070/E8
Open Tender
Civil Works - Water Works
Lump-sum
548 days
DRASS KARGIL
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE KARGIL
₹2.9 L
Yes
13 Aug 2021
3 Mar 2021
17 Apr 2021
4 Mar 2021
10 Apr 2021
27 Mar 2021
4 Mar 2021 - 10 Mar 2021
Amount
BUILDING WORK (SCHEDULE 'A' PART-I) Lump sum price worked out by the Contractor for “Building Work” as listed in Schedule ‘A’ Part- I.
INTERNAL WATER SUPPLY (SCHEDULE 'A' PART-II) (Sec-I) Lump sum price worked out by the Contractor for “Internal water supply” as listed in Schedule ‘A’ Part- II (Sec-I)
INTERNAL WATER SUPPLY (SCHEDULE 'A' PART-II) (Sec-II) SCHEDULE `A' PART-II(Sec-II) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
S&F for Brass CP shower rose 125mm size, complete all as specified and directed.
Sub Total
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III)(Sec-I) Lump sum price worked out by the Contractor for “Internal Electrification” as listed in Schedule ‘A’ Part- III (SEC-I)
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III)( Sec-II) SCHEDULE `A' PART-III(Sec-II) is not prepriced by MES and prepriced rates indicates 5.01 to 5.05 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply and fixing of wall mounted LED batten , high efficiency comprising of extruded chanel in thermally conductive material with white diffuser to get glare free and smooth light distribution , 1x20 Watts LED 6K, Pre-wired suitable for surface mounting on wall, ceiling , all accessories prewired including connecting with PVC insulated multi stranded copper flexible cable of suitable size three core, complete all as specified and directed.
Supplying and fixing of wall mounted LED batten , high efficiency comprising of extruded chanel in thermally conductive material with white diffuser to get glare free and smooth light distribution , 1x10 Watts LED 6K, Pre-wired suitable for surface mounting on wall, ceiling , all accessories prewired including connecting with PVC insulated multi stranded copper flexible cable of suitable size three core, complete all as specified and directed.
Supply and Fixing exhaust fan of size 200mm sweep with louvers and connecting including provision 3 core flexible PVC insulated multi stranded copper conductor of suitable size from ceiling rose / connector to fan complete all as specified and directed.
Supply and fixing 6 to 16 Amps MCB SP 50 C/S 10 KA 'C' series complete all as specified and directed.
Supply and fixing LED street Light fitting 36 Watt made of pressure die cast housing, with toughened glass and high power LEDs with with IP65 protection complete with 40 mm GI pipe bracket not less than 1.2 mtr length and bent to a shape incl 02 Nos 25x6 mm flat clamps with nut bolt and washers complete with all fixing acessories as reqd at site for fixation on wall and connection with 3 core flexible copper suitable size wire complete all as specified and directed
Sub Total
Puff tank with staging (SCHEDULE 'A' PART-IV) (Sec-I) Lump sum price worked out by the Contractor for “Puff tank with staging” as listed in Schedule ‘A’ Part- IV Sec-I.
Puff tank with staging (SCHEDULE 'A' PART-IV) (Sec-II) SCHEDULE `A' PART-IV) (Sec-II) is not prepriced by MES and epriced rates indicates 7.01 and 7.02 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
S&F for puf tank of capacity 1000 Ltrs each and including 75mm thick puf insulation complete all as specified and directed.
S&F for puf tank of capacity 500 Ltrs each and including 75mm thick puf insulation complete as specified and directed.
Sub Total
SEWAGE DISPOSAL (SCHEDULE 'A' PART-V) Lump sum price worked out by the Contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part- V
PROTECTIVE WORK (SCHEDULE 'A' PART-VI) Lump sum price worked out by the Contractor for “PROTECTIVE WORK” as listed in Schedule ‘A’ Part-VI
BORE WELL (SCHEDULE 'A' PART-VII) (SCHEDULE 'A' PART-VII) is not prepriced by MES and prepriced rates indicates 10.01 to 10.32 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Drilling the Pilot (Trial) bore well for boring trial bore well as per IS 2800 in any strata upto following depth of 200 mm dia bore to deliver 6 LPS quantity of water i.e. yield complete all as specified and directed.
(a) Depth upto 25 m
(b) Depth from 26 m to 50 m
(c) Depth from 51 m to 75 m
(d) Depth from 76 m to 100 m
(e) Depth from 101 m to 125 m
(f) Depth from 126 m to 150 m
(g) Depth from 151 m to 175 m
(h) Depth from 176 m to 180 m
Note for item no. 10.00 (a) The rate quoted by the tenderers shall be deemed to include for tranportation of suitable truck mounted drilling attachment alongwith necessary accessories and T & P and also clearance for setting of machinary etc. (b) Lithlog testing by using computerized composite lithlog machine and ascerterning the position of slotted and plain casing pipes and finding out the approximate yield of the bore after chemical/bactrological analysis shall be carried out before lowering of cassing pipe and report must be submitted to GE for approval. Rate for Electrical logging test also included in quoted rate. (c) Second and third trial bores shall only be carried out in case the first and second trial bores respectively declared to be unsuccessful by the GE in writing. (d ) Depth of second and third trial bores may vary if suggested by the CGWB. Contractor shall have no claim on account of reduction or addition in the depth. In case the depth is increased beyond 180 m, rate of item No. 10.09(h) shall be applicable for the increasing depth. (e) Payment of unsuccessful trial bore(s) shall only be released after successful boring in the successive trial. However in the event of unsuccessful boring even after 3 Nos of trial bores if it is declared to be given up, the site will be abandoned & payment for all the trial bores will be allowed only after approval of accepting officer. (f) Rate applicable for payment of the second and third trial bore shall be 20 % less than the rates quoted against 1st trial bore (item No.10.02 to 10.09).
Development of bore well by means of compressor of min 250 PSI capacity and over pumping by pump of capacity not less than 25 HP until the sand free water obtained and carrying out necessary yield test by V notch method and submitting the test report complete all as specified and directed. Note - The compressor/submersible pump set and other equipment shall be arranged by contractor and cost of FOL for running of compressor is deemed to be included in the item rate complete all as specified and directed.
Supply, assembling and lowering 200 mm nominal bore mild steel ERW ISI marked casing blank pipe having wall thickness 8 mm as per IS - 4270-1992 and jointing with electric arc welding, screwing and socketed in random length of 3 to 6 m, including necessary fittings i.e. special steel sockets, coupling , jointing and painting with two coats of bituminous paint of external surfaces of pipe below ground level complete all as specified and directed.
(a) Depth upto 25 m
(b) Depth from 26 m to 50 m
(c ) Depth from 51 m to 75 m
(d ) Depth from 76 m to 100 m
(e ) Depth from 101 m to 125 m
(f ) Depth from 126 m to 150 m
(g) Depth from 151 m to 162 m
Supplying, assembling and lowering 200 mm nominal bore MS ERW fine cut having wall thickness 8 mm slotted pipe confirming to IS 4270-1992 with slot of suitable size and number as per location of intermediate aquifiers complete all as specified and directed. NOTE - for Srl Item No. 9.13 only - Item qty and depth may vary depending upon the actual requirement at site.
Supply, jointing, assembling, lowering and fixing in position stainless steel (55304) 'v' wire screen suitable for 200 mm bore pipe having a screen opening of 0.5/0.75/1.00 mm depending on water bearing strata and assembled lowered as per location chart approved by GE including cutting, threading complete all as specified and directed.
M&L Mild steel casing shoe to be welded with MS ERW casing pipe of 200 mm nominal bore complete all as specified and directed.
M&L for MS housing clamp made of MS flat iron of size 115cm x 20 cm x 2 cm to hold 80 mm dia MS column pipe at/or ground level including two coats of black bituminous paint over a coat of red oxide primer complete, all as specified and directed.
Supply only strata box made of 20 mm thick in veneered particle board and 12 mm thick ply wood with 25 mm x 25 mm aluminium angle 2 mm thick bearer overall length 1200 mm x 750 mm x 100 mm with front glass sheet sliding type cover with aluminium frame all around 2 nos. key holes plate of size 40 mm x 25mm and 3 mm thick complete showing name of tube well location and strata chart complete (duly glass framed with wooden beadings) showing depth complete all as specified and directed.
M&L for MS well cap fabricated out of 6 mm thick MS Sheet having an internal threading and locking arrangement for 200 mm dia bore pipe in two pieces having 80 mm dia hole in centre with external bracket of flat iron of size 100 mm x 6 mm thick complete with nut, bolts and washers etc including painting over a coat of red oxide primer complete all as specified and directed.
M&L for Foundation including earth work, excavation, removal etc for holding of tube well of size 100 x 100 x 100 cm at ground level made of precast cement concrete 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) complete all as specified and directed.
Chemical/bacteriological analysis and potability test of water obtained from from Borewell and get tested from state water testing depratment/ NABL accredited lab and submitting the report in triplicate, complete all as specified and directed.
Fixing only and Installation, lowering, testing and commissioning for submersible pump, motor complete all as specified and directed. Note- The rate quoted is deemed to be inclusive the cost necessary for MS pipe and suitable accessories for connecting delivery lines to the delivery of pumpset so as to match the manufacturers
Fixing only for motor starter including all inbuilt protection for single phase prevention, for single phase prevention, over voltage, under voltage in sheet steel enclosure 2 mm thick on MS frame box with provision for fixing / mounting on for submersible pump relay of suitable range, including all connections from LT Panel to starter and starter to motor complete all as specified and directed. Note- The rate quoted is deemed to be inclusive the cost of necessary accessories.
Supply and fixing submersible copper conductor cable 3 core 16 sqmm 1100 volts flat including Nylon binding wire and accessories to clamp with column pipe at places to column pipe complete all as specified and directed.
Supply, lowering & fixing MS flanged Pipes medium grade of bore 80 mm with MS Flange of 10 mm thick including provision to cut for passing submersible cable and four no. holes 10 mm dia 3 meter length with suitable size of nut bolts washers and rubber gaskets complete all as specified and directed.
Supply only copies of details of borehole strata and assembly alongwith details on full size paper duly laminated and framed with 10 mm thick particle board complete all as specified and directed.
Sub Total
EXTERNAL WATER SUPPLY (SCHEDULE 'A' PART-VIII) (SEC-I) Lump sum price worked out by the Contractor for "External water supply" as listed in Schedule ‘A’ Part-VIII (Sec-I)
EXTERNAL WATER SUPPLY (SCHEDULE 'A' PART-VIII) (SEC-II) SCHEDULE `A' PART-VIII (Sec-II) is not prepriced by MES and prepriced rates indicates12.01 to 12.12 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply, installation, testing and commissioning of horizontal type submersible pumping set, multi stage, of discharge capacity 4000gallon per hour at 130 metre head, and including 3 phase, 50Hz, 415 Volts, suitable size motor of the same manufacturers, including MS adopter or reducer and all accessories for proper functioning of pumping set etc, complete all as specified and directed.
Supply and fixing Cast iron Air Release Valves with double orifice air Outlets, conforming to IS 14845, class PN 1.6 of size 100 mm dia bore and fixing up in GI Water supply mains of size 100 mm dia. Complete all as specified and directed.
Supply and fixing Cast Iron reflux/NRV valve with by pass arrangement of size 80 mm dia including nuts ,bolts, gasket etc as jointing material reqd as per site reqmt complete all as spd and directed. Complete all as specified and directed.
M &L for Construction of Valve pit of size 120cm x120cm x 220cm (internal dimensions), PCC Block construction, including all necessary excavation and earth work in hard/loose soil, returning , filling in disposal of surplus spoil to distance not exceeding 50m and depositing where directed, PCC in foundation of the mix 1:4:8, type D-2, (Using 40mm graded crushed aggregate) copingin PCC (1:2:4) type B-0 using 12.5mm crushed stone aggregate, brick masonry in cement mortar 1:6, rendering 12mm thick in cement mortar 1:4, internally, externally above ground level around as the work proceeds in the same mortar mild steel frame of size 50 x 50 x 6mm, MS sheet cover 3.15 mm thick with handle and locking arrangement, painting to all the exposed M.S work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the M.S embedded in PCC with two coats of black bituminous paint complete all as specified directed.(Note:- The earth works rates are included in this item)
M &L for Construction of Valve pit of size 120cm x120cm x 150cm (internal dimensions), PCC Block construction, including all necessary excavation and earth work in hard/loose soil, returning , filling in disposal of surplus spoil to distance not exceeding 50m and depositing where directed, PCC in foundation of the mix 1:4:8, type D-2, (Using 40mm graded crushed aggregate) copingin PCC (1:2:4) type B-0 using 12.5mm crushed stone aggregate, brick masonry in cement mortar 1:6, rendering 12mm thick in cement mortar 1:4, internally, externally above ground level around as the work proceeds in the same mortar mild steel frame of size 50 x 50 x 6mm, MS sheet cover 3.15 mm thick with handle and locking arrangement, painting to all the exposed M.S work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the M.S embedded in PCC with two coats of black bituminous paint complete all as specified directed.(Note:- The earth works rates are included in this item)
M & L for Construction of Valve pit of size 90cm x90cm x 150cm (internal dimensions), PCC Block construction, including all necessary excavation and earth work in hard/loose soil, returning , filling in disposal of surplus spoil to distance not exceeding 50m and depositing where directed, PCC in foundation of the mix 1:4:8, type D-2, (Using 40mm graded crushed aggregate) copingin PCC (1:2:4) type B-0 using 12.5mm crushed stone aggregate, brick masonry in cement mortar 1:6, rendering 12mm thick in cement mortar 1:4, internally, externally above ground level around as the work proceeds in the same mortar mild steel frame of size 50 x 50 x 6mm, MS sheet cover 3.15 mm thick with handle and locking arrangement, painting to all the exposed M.S work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the M.S embedded in PCC with two coats of black bituminous paint complete all as specified directed by Engineer-in-charge.(Note:- The earth works rates are included in this item)
Supply and fixing 60mm thick closed cell elastomeric insulation 42 kg /m3 density glass wool fiber insulation with Al cover over GI pipes of size 100/80 mm complete all as specified and directed.
Supply, installiation testing and commissing of water level indicator with alarm by showing filling level stage from 10% to 100% in 10 stages(10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90% and 100% to filled are empity the sump) LED bulb indicator connecting through water sencer installed at underground sump with connecting of circuit by using 10 pairs of telephone cable of sutaible size copper conductor.(Note:- 10 pairs telephonic cable shall be measured and to be paid seperately in relevant item) .
Supply and laying of telephonic cable 10 pairs of sutaible size of copper conductor size 0.10 sq mm by including connecting of water sensors and water level indicators at UG Sump and pump house.
Supply & installation, testing and commissioning of Chemical dozing system mechanically activated diaphragm pump with speed, stroke & length controlling operation on 415volts 3 phase 50 Hz supply,motor of size 1.5 KW complete with suction/discharge & other accessories capacity 8 litres per hour and injection pressure 0.9 Kg/Sqcm, pump set suitable for injecting the doze of hypo chloride solution to get the result of chlorine contents 2ppm at tube well point and to pump into discharge line of submersible pump of cap of 4000 GPH capacity at 130 metre head, complete all as specified and directed. Note - Qty 12 ltr of Sodium Hypochloride also included in quoted rates complete all as specified and directed.
Supply and laying GI tubing medium grade flanged pipe of dia 100 mm ISI marked complete with all necessary fittings such as nut,bolt and washer and necessary rubber gasket packing laid in trenches/wall/ floor etc. Complete all as specified and directed.
M&L for providing antifreezing /tracer cable required to keep the pipe warm upto avoiding freezing connection complete all as specified and directed.
Sub Total
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-IX (SEC-I) Lump sum price worked out by the Contractor for “External Electrification” as listed in Schedule ‘A’ Part-IX Sec -I.
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-IX (SEC-II) SCHEDULE `A' PART-IX Sec -II is not prepriced by MES and prepriced rates indicates 14.01 to 14.07 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply, Installation, testing and commissioning of 100 KVA (80KW), 415 Volt, 0.8 PF, 3 phase, 50 Hz, factory assembled Silent Diesel Engine Driven Generating set, mounted on common base plateform with flexible coupling 1500 RPM alongwith sound proof enclosure (acoustic enclosure) designed for reducing the sound level to 75 DB(A) average IS 8528 Part-10 as per approved CPCB norms and as per GSR 371 (E) and independently supported from engine to outside of power house upto 1.00 mtr, AVM pads foundation as per manufacturer's design, cold starting kit battery start with suitable cables for connecting from DG set to panel board, DG set shall be capable of operating in temperature range of (-35 to +35 degree centigrade) complete with and including of the following accessories :- (A) Prime Mover :- Diesel Engine of suitable capacity water cooled/coolant cooled radiator type closed circuit as per BIS 649 or IS-1002 direct inject type turbo with turbo charger. The DG set shall be capable of running 24 hrs continuously with 10% overloading for one hour in every 12 hrs as per BIS-5514 / BIS-649, Engine shall be equipped with all standard fitting as per manufacturers recommendations and mounted on common base frame through flexible coupling with following accessories :- (i) Battery charging ammeter (ii) Battery charging voltmeter (iii) Ignition key and starting with push button switch (iv) Lubricating oil pressure gauge.
(v) Electronic / Microprocessor based Governor controlling (vi) Toggle switch for idle running (vii) Oil temperature gauge (viii) Water temperature gauge (ix) Safety Control (Trip):- (a) High water temperature (b) Low lubricant oil pressure (c) Over speed. (x) Lubricant oil heater to avoid freezing (xi) 24 Hours starting equipment comprising of the following :- (a) 01 No, 12 Volts, 180 AH Battery as per requirement (b) Battery charging alternator with inbuilt regulator (c) Self starter motor of suitable capacity (d) Battery leads (copper standard cable) of suitable size with brass thimbles and terminals
(f) MCCB for incoming as recommended by manufacturer – 01 (g) Set of indicating lamps for 03 phase RYB - 01 (h) Oil pressure meter - 01 (j) Set of copper bus bar of suitable size - 04 Nos (D) Other Fittings :- (i) Battery charger:- Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts, 180 AH battery 01 Nos at a time and with 01 Nos ammeter or suitable range provision of incoming electric connector single phase 220 Volts and two terminal of connecting outgoing leads to connect battery including suitable size of 02 Nos copper leads with connecting clips duly fixed on suitable size of angle iron frame made out of 40x40x6 mm angle iron and suitable size of wooden plank complete all as specified and directed. Note :- The contractor shall produce a copy of approved certificate to authenticate the above from the OEM/OEAD. (ii) Fuel Tank capacity as per manufacturer recommendations on steel frame at suitable height with all connecting pipes and fitting upto pump and over flow pipe form engine to tank including fuel level indicating gauge duly marked and drain valve and air vent plug etc.
(E) Maintenance Spares :- (i) Fuel fitter element - 02 Nos (ii) Oil fitter – 03 Nos (iii) Fan Belt – 01 Nos (iv) Hose Belt - 01 Nos (v) Tappet cover gasket - 01 Nos (F) DG Set shall be supplied alongwith acoustic original enclosure of the manufacturer suitable for 100 KVA DG set as per CPCB Norms. (G) Tool kit as supplied by the manufacturer alongwith each set - 01 set complete. (H) The DG set shall be tested by the Contractor in presence of the Accepting Officer’s representative / IEM & Engineer-in-Charge for 12 hr as per standard procedure without any extra cost to the department and the quoted rates are deemed to be included for all these aspects. (I) Payment of DG set will be made after satisfactory testing. (J) The DG Set 100 KVA shall be supplied, installed, tested & commisioned at Drass(location as directed by Engineer-in-charge) under the AOR GE Kargil and the quoted rates are deemed to be included for this aspects. (k) The load for testing is also included in item rate.
Supply and installation erection commissioing and testing of main LT pannel cubical indoor type weather/dust proof, factory made out of 2 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 200 amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and flands complete comprising the following:-
Sub Total
Prime Cost Sum (a) Provide a PC sum of Rs 110500.00 for supply only of submersible pump set, motor and fully automatic Star - delta motor starter for bore well. (b) Add 15% (Fifteen percent) above on Serial item No 15(a) above for contractors over head charges and profits i.e Rs 19500.00. (c) Total of Serl 15 (a) & (b) :- Note:- Fixing, commissioning & installation shall be paid & measured in item No 10.28 & 10.29 here-in-before.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .