Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.7 L+₹2.7 L (24.6%)Rejected-Finance KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance Being L2 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
9 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR / MAINT OF SUMMER APPLIANCES AT HARNI/HARNI AIRFIELD AT AF STN BARODA
2021_MES_488054_1
8680/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹38,000
Yes
12 Feb 2022
12 Nov 2021
11 Dec 2021
12 Nov 2021
9 Dec 2021
26 Nov 2021
13 Nov 2021 - 18 Nov 2021
60 days
Amount
Material and labour for replacement of unserviceable hermitically sealed compressor of Refrigerator 310/ 280 Ltr. Capacity with new uncut hermitically sealed compressor including suitable relay and over load with new sealed unit as per the company manufacturer complete all as specified and directed.
All as above item No 1.00 but for 165/ 170/ 180 Ltr capacity refrigerator.
Material and labour in replacement of relay suitable for 280/ 310 liters cap refrigerator as per existing make complete all as specified and directed.
All as above item No 3.00 but cap 165/170/180 Ltrs. Refrigerator
M&L in repair of thermostat automatic `R' frost with knob suitable for 165/170/280/310 liters cap refrigerator as per existing make complete all as specified and directed.
M&L in repair of freezer assembly complete with screw, jointing of tubes etc. and testing of cap 280/310 Ltrs refrigerator (any make) complete all as specified and directed.
All as above item No 6.00 but of capacity 165/170/180 Ltr refrigerator.
Material and labour in replacement of condensor unit of refrigerator cap 280/ 310 Ltrs jointing of tubes and testing etc complete all as specified and directed.
All as above item No 8.00 but for 165/170/180 ltrs capacity refrigerator.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with suitable refrigerant for up to 310 ltr capacity refrigerator complete all as specified and directed. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labor for replacement of unserviceable cut sealed compressor of window type/split type ACs 1.5TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, complete and testing after completion of work at MES store yard for satisfactory functioning complete all as specified and directed. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
All as per ser item No.11.00 above but for 2 TR capacity Split / Window type AC.
Material and labour for rewinding of blower motor of Speed 900 RPM of window/Split Air conditioner of capacity 1.5/ 2 ton any make with super enameled copper conductor including replacement of worn out bushes ,Shaft and capacitor etc complete all as specified and directed.
Labour only for attending complaints of Air conditioner carried out by manufacture's authorised mechanic from the servicing centre without any delay with rectified the defects by carefuly opening and check the ACs parts which defects find out at site and replace the defected parts from the ACs for smooth functioning complete all as specified and directed Note :- Supply only item shall be measure and paid seperately under respective item of BOQ
All as per item no 14.00 above but for AC plant of 22 TR Capacity
Supply only condensor fan motor of outdoor unit of capacity 1.5 TR and existing make.
Supply only Condensor fan motor of outdoor unit of capacity 2.0 TR and existing make.
Supply only Blower motor of indoor unit AC type of capacity 1.5 TR and existing make.
Supply only Blower motor of indoor unit AC type of capacity 2.0 TR and existing make.
Supply only Blower motor of indoor unit DC type of capacity 2.0 TR and existing make -Samui.
Supply only Capacitor of capacity 50/45 MFD, 240 volts 50 cycles
Supply only Capacitor of capacity 55/60 MFD, 240 volts 50 cycles
Supply only Over load protector with relay.
Supply only Thermostat switch for Split/window type AC cap.1.5/ 2.00 ton capacity
Supply only in repair Defective wiring set (with suitable copper wire)
Supply only Condensing fan motor blade of outdoor unit of any capacity.
Supply only Air filter 5 micron as per existing size
Supply only Expansion valve as per existing size
Supply only Blower for window/split type AC capacity 1.5 Ton.
Supply only Blower for window/split type AC capacity 2.0 Ton.
Supply only Sensor for indoor unit of split/window type AC of any capacity.
Supply only Contactor NO/ NC type as per existing make and capacity.
Supply only Evaporator Coil for split AC 1.5 TR and existing make.
Supply only Evaporator Coil for split AC 2.0 TR and existing make.
Supply only PCB Card for split type AC of capacity 1.5 TR as per existing make and model
Supply only PCB Card for split type AC of capacity 2.0 TR as per existing make and model
Supply only PCB Card for invetor type split AC 1.5 as per existing make and model
Supply only PCB Card for invetor type split AC 2.0 as per existing make and model
Supply only Remote hand set for split type/window type AC 1.5/2 TR capacity
Supply only Valve 1/2 " ,1/4 " and 5/8 " for split type AC 1.5/2 TR capacity
Supply only Condensor unit of capacity 1.5 TR split AC.
Supply only Condensor unit of capacity 2.0 TR split AC.
Supply only Drainout Pipe of existing make
Supply only Swing motor of split AC capacity 1.5/2.0 TR of existing make.
Supply only Mounting stand for outdoor unit split type AC
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with refrigerant R-22, R-32, R-401A oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton complete all as specified and directed.
Material and labour for servicing/ overhauling with chemical wash of split /Window type AC unit capacity 1.5/ 2.0TR complete all as specified and directed.
M&L in repair of copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
M&L in repair of copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
M&L in repair of copper pipe of size 5/8 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
Material and labour for foam type insulating flexible pipe fitted on suction/ discharge copper tubes complete all as specified and directed.
Taking down carefully existing split type AC of capacity 1.5/2 TR (complete unit) and refixing the same from one site to another site as per users requirement complete all as specified and directed.
Material and labour for repairing of PCB of split type AC of capacity 1.5/2 TR soldering and brazing of circuit, including replacement diode IC complete all as specified and directed.
Supply and fix in repair single pole and neutral enclosure with 2 pin earth industrial plug and socket complete with one MCB SP 20 Amps as in replacement complete all as specified and as directed.
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for water cooler cooling capacity 40 liters/hour with new uncut sealed compressor supplied by manufacture complete. (Makes :-Tecumesh/Kirlosker copeland or existing make) Note:- i) Old sealed compressor received from the water cooler will be property of contractor ii) The rate quoted by the contractor includes all charges like transportation , filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition iii ) The new sealed unit will be purchased from authorized dealer/manufacturer.
Supply and fix in repairs of following parts for Water cooler for Storage Capacity 80 Ltr Cooling cap 40 Ltr/hr complete all as specified and as directed.
Copper filter and capillary tube of water cooler of any cap and existing make.
Relay with over load protectors of water cooler of any cap and existing make.
Condensor fan of motor HP- 1/32 ,RPM-1300 with clips and motor fixing stand of water cooler of any cap and existing make
Thermostat switch with knob of water cooler of any cap and existing make
Drip tray made out stainless Steel sheet of water cooler of any cap and existing size.
Fan motor mounting stand of water cooler of any cap and existing size.
Push cock, 15mm bore of water cooler of any cap.
Running capacitor of 10 Mfd of water cooler of any cap.
Starting capacitor 40 Mfd 240 volt AC Supply of water cooler of any cap.
Fan blade for condensing fan motor of water cooler of any cap.
Condenser unit of existing size and make of water cooler of any cap.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with suitable refrigerant, oil charging complete in compressor of water cooler having capacity 40 ltr per hour of existing make complete all as specified and directed & with entire satisfaction of Engineer-in-Charge. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and Labour for rewinding of condensing fan motor of water cooler (1/35 HP) cap. 40 Ltr/Hr with super enameled copper wire of suitable gauge including insulating material and replacement of gun metal bush & capacitor 2.5 MFD complete all as specified and directed.
S&F in repair of copper piping with fittings for hot gas line from package AC 22 TR unit to outdoor condenser unit, hard copper pipe of 18 guage having size of 5/8" with supporting accessories and painting complete all as specified and directed.
S&F in repair of copper piping with fittings for liquid line from package AC 22 TR unit to outdoor condenser unit, hard copper pipe of 18 guage having size of 7/8" with supporting accessories and painting complete all as specified and directed.
S&F in repair of copper piping with fittings for liquid line from package AC 22 TR unit to outdoor condenser unit, hard copper pipe of 18 guage having size of 11/8" with supporting accessories and painting complete all as specified and directed.
S&F in repair of cath all driers 5/8"x5/8" for package type AC 22 TR complete all as specified and directed.
S&F in repair of ball valves 5/8" in liquid line for package type AC 22 TR complete all as specified and directed.
Material and labor for replacement of unserviceable cut sealed compressor of package type AC plant 11TR capacity with new uncut sealed scroll compressor unit 11TR capacity supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, complete and testing after completion of work satisfactory functioning complete all as specified and directed. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labour for servicing/ overhauling with chemical wash of package type AC capacity 22 TR complete all as specified and directed.
Material and labour for rewinding of blower motor of 5 HP 3 Phase 415 V package type AC capacity 22 TR with super enameled copper conductor including replacement of worn out bushes, Shaft etc and testing complete all as specified and as directed.
Material and labour for rewinding of condensor fan motor of package type AC capacity 22 TR with super enameled copper conductor including replacement of worn out bushes ,shaft and capacitor etc and testing complete all as specified and as directed.
Supply and fix in repair of contactor CE certified for 5 HP motor starter 415 V, 50 Hz capacity for blower motor of AC plant of capacity 22 TR complete all as specified and directed.
Supply and fix in repair fan blade suitable for 11 TR capacity plant complete all as specified and directed.
Supply and fix in repair of contactor CE certified for 11 TR compressor 415 V, 50 Hz capacity for AC plant complete all as directed.
Material and labour for rewinding of Desert Cooler fan motor 3 speed,1400 RPM any make of cap. 1/5 HP with super enameled copper wire of appropriate size incl. replacement of bush, shaft and oil filled capacitor 4 MFD, 240 volts complete all as specified and directed.
Material and labour for painting to old steel surfaces of Desert cooler up to 5000 cfm with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES NO etc complete all as specified and directed.
S&F Fan motor cap three speed,1400 RPM single phase of Desert cooler with stand complete all as specified and directed.
S&F Submersible pump for Desert cooler of existing make. complete all as specified and directed.
S&F Wood/ wool chips pad for Desert Cooler (set of three pads) complete all as specified and directed.
S&F Supporting jali of wood/ wool chips pad set made out of hard MS wire and fitted in side louvers. (set of three pads) complete all as specified and directed.
S&F Name plate of front grill (as per sample kept in AGE E/M office). complete all as specified and directed.
S&F Desert Cooler body with tank, slide panel, front grill etc complete complete all as specified and directed.
S&F PVC water distributor of 3 outlets with MS nuts & bolts. complete all as specified and directed.
S&F PVC elbow suitable for desert cooler (as per sample) complete all as specified and directed.
S&F PVC pipe 15 mm dia heavy duty for Desert Cooler Pump. complete all as specified and directed.
S&F 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz complete all as specified and directed.
S&F Motor fixing ring for desert cooler eight screw / clip type complete all as specified and directed.
S&F Desert cooler Capacitor 4 mfd 240 Volt complete all as specified and directed.
S&F Fan blade suitable for fan motor 1400 RPM capacity for Desert cooler. complete all as specified and directed.
S&F in repair of single phase input 180 to 250 Volts out put voltage stabilizer 230V complete and testing on completion of 5 KVA capacity complete all as specified and directed.
M &L in repair of replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 23/ 0.0076 cross sectional area superior quality complete all as specified and directed.
M/s Yash Electrical and Maintenance
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .