| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.0 L+₹2.1 L (6.04%)Rejected-Finance PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹38.1 L+₹4.1 L (12.0%)Rejected-Finance JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
4 Jul 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
SPECIAL REPAIR TO BUILDING NO. P-45 TO P-47 (MES COMPLEX), INTERNAL ELECTRIFICATION AND ALLIED FIXTURES AT LIBRARY AT INS SARDAR PATEL AND PROVISION OF EXTENSION OF EXTERNAL WATER AND ELECTRIC SUPPLY AT NAVAL OFFICER INSTITUTE UNDER GE NAVY PORBANDAR
2022_MES_517385_2
9115/PBR/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹70,000
Yes
18 Jul 2022
10 Jun 2022
5 Jul 2022
10 Jun 2022
4 Jul 2022
17 Jun 2022
10 Jun 2022 - 16 Jun 2022
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing, rubbish off the premises complete all as specified and directed.
Non skid Ceramic coloured Joint free tiles of size 300x300x7-8mm thick (area of each tile exceeding 0.6 Sqm but n.exc. 0.11 Sqm) as in floor set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over and including 15mm thick bedding layering cement mortar (1:6) complete as specified and directed.
Glazed ceramic tiles, coloured (light colour as approved) of size 300x600x7to8mm / 350x250x7to8mm / 450x300x7to8mm / 300x200x7to8mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete as specified and directed.
Vitrified Ceramic tiles 9-10 mm thick, Light shade coloured (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including screed bed or bedding layer 20mm thick in cement mortar 1:6 complete all as specified and as directed.
Vitrified Ceramic tiles 9-10 mm thick (square / rectangular) area of each tiles not exceeding 0.36 sqm, as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid dry beded in any mortor complete all as specified.
Granite 20mm thick machine cut, bedded andjointed as in cills, jambs, steps and the like with grey cement slurry and pointed with white cementwith admixture of pigment to match the shade of granite stone including grinding and polishing, etc with 15mm thick screed in cement mortar (1:4) complete all as specified.
20mm thick Granite machine cut, in skirting/dado door window sill, jambs etc laid over cement screed (1:3) and jointed with grey cement slurry, and pointed with white cement with admixture ofpigment to match the shade ofgranite stone including grinding and polishing complete all as specified.
Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete artilcles and precast concrete block walling etc. Complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses but except stone complete all as specified and directed (Serviceable stones retrieved from item No. 10 will be reused).
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Rendering 15mm thick on fair faces of brickwork or concrete surfaces 'in CM 1:4 finished even and smooth without using extra cement all as specified and directed.
Rendering 5mm thick in CM 1:3 on concrete surfaces finished even and smooth without using extra cement as in ceiling complete all as specified and directed.
Forming jambs, etc. with CM ( 1:6) or Cement Concrete 1:1:8 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as spd
Preparation of new plastered surfaces and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of white primer and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complet`e, as per manufacturer's specification complete all as spd and as directed by Engineer in Charge.
Preparatiion of new plastered surfaces and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as spd and as directed by Engineer in Charge.
Preparation of new plastered surfaces of ceiling applying two coats of white wash complete all as specified and directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete all as specified.
Preparation of old steel surfaces of any description, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
Material and labour for preparation of old wooden surfaces of any description exceeding 10 cm width or grith not otherwise described and applying one coat of syntheic enamel paint complete all as specified and as directed.
Preparation of new or previously untreated surface of wood or wood based materials of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
Preparation of old surfaces of walls by washing scrapping rubbing down and stopping of painted surfaces, removing grease, Nail paints, other marks, preparing the surfaces with wall care putty and applying one coat of water based distemper complete all as directed by Engineer-in-Charge.
Preparation of old surfaces of ceiling including cornicess plasters and applying one coat of lime wash (white washing) on ceiling complete all as specified and directed.
Preparation of old surfaces of walls, chajjas and projections etc by washing scrapping rubbing down and stopping of painted surfaces and applying one coat of first quality weather proof acrylic paint exterior grade complete all as directed by Engineer-in-Charge.
S&F Mild steel CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F Mild steel CRS bars 6mm dia and over upto and including 10mm dia in stirrups and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Demolition of reinforced cement concrete in ground floor and paving in any position below or above ground level complete all as specified and as directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in roof slab supported on walls, beams and columns in roofs complete all as specified and directed.
Use and waste of wooden Formwork to soffits of suspanded slabs such as roof slabs, floor slabs, beams, landings and similar work etc (Horizontal/sloping/verticle) complete all as specified and directed.
Vitreous China wash down water closet (European pattern) white with connected S-Trap / P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe fixed in repairs complete all as specified and directed.
Vitreous china white squatting pan Orissa pattern of size 580mm x 440 mm with integral foot rests including necessary cement concrete and 100 mm bore ‘P’ trap SWR (PVC) with 550 to 600 mm long neck for connecting WC to branch piece with cement joints fixed in repair complete all as specified and as directed.
PVC low level flushing cistern 10 litres capacity valve less symphonic action type, ISI Marked white with inlet, ball valve, float and handle including brackets fixed in repairs complete all as specified and directed.
Fixing only 10 litres capacity PVC flushing tank, syphonic action type, high / low level, valveless, with PVC inlet ball valve, PVC flush pipe, float, chain and pull and suitable sized brackets including taking down complete all as specified and directed by Engineer in charge.
Vitreous China wash hand basin white flat back, size 550mm x 400mm, cutting for and pinning in ends of brackets Including waste pipe, brass coupling, 32 mm bore chromium plated brackets, restoring all connections, fixed in repairs, complete all as specified.
Pillar tap brass 15mm bore, with capstan head chromium plated fancy type screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe fixed in repairs complete all as specified and directed.
Soap dish brass chromium plated, vitreous China white, approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws complete all as specified.
Toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified.
Brass Chromium plated towel rail, 600mm long, min 20mm dia pf superior quality, fancy type fixed in repair complete all as specified.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing complete all as specified and as directed.
ABS body Health faucet with wall hook and 1 metre SS braided rubber holes pipe complete all as specified. Make : CERA - F8030102 or F8030301 or equivalent model of make specified here-in-before.
CP brass wall mixer for mixing hot & cold water with bend pipe for over head shower screwed down for CPVC and fixed as in repair complete all as specified.
Brass chromium plated shower rose 125mm size and 15mm dia with swivel joint and arm including fixing to steel pipe or union complete fixed in repairs,complete all as specified and directed.
15mm bore fancy type CP brass Stop cock / Angle valve with wall flange fixed in repair / replacement complete all as specified.
Bib cock brass long nose chromium plated with wall flange and aerator for CPVC pipe and fixed in repair / replacement complete all as specified.
Angle valve Flora 2 in 1 Brass Chrome Plated / Two way Angle Cock / Angle Cock Quarter Turn with wall flange and areator for CPVC pipe and fixed in repair / replacement complete all as specified.
CP Sink tap brass chromium plated with long nose (swan neck type) Fancy type with wall flange and areator for CPVC pipe and fixed in repairs complete all as specified.
Statinless steel plate rack size 900x700x250mm complete all as specified.
Kitchen sink with drainage board made of stainless steel 1mm thick (SS grade 304AISI 18/8) IS embossed (IS:13983) glossy finish with plugs, washers and wastes; including bedding in cement mortar to platform or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, fixed in repairs, complete all as specified.
Low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm,600mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe fixed in repair / replacement complete all as specified.
CP grating square min 150mm size fixed in repair / replacement complete all as secified.
Taking down chowkats or frames exc 1.5 sqm and n.exc 4 Sqm each with shutter (without taking off Shutter) complete all as specified.
Taking down Shutters of any description exc 1 Sq. m and n exc 2 sq. m each and removing complete all as specified and as directed.
Factory made 35 mm thick,2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified.
35mm 2nd class HW rail and style Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified.
Plain solid, straight chowkats and frames of second class hard wood Wrought Framed rabatted on the solid rounded or chamfered, put together with glue pinned at joints Complete all as specified and directed.
Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Supply and fixing 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
S & F Stainless steel curtain rod fixing with side brackets, finials on both end of every opening length end cups, etc and fixed with PVC rawl plugs & steel screws as in repairs complete all as specified.
Dismantling boarding, any description, fixed in any position with nails complete all as specified.
18-19mm thick pre-laminated particle board (incl dismantling), flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in cup board shutter , shelves etc including 6 mm thick teak wood leaping on three sides and 20mm thich on hanging side & French polishing to edging complete all as specified.
25mm thick pre-laminated particle board (incl dismantling), flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in cup board shutter , shelves etc including 6 mm thick teak wood leaping on three sides and 20mm thich on hanging side & French polishing to edging complete all as specified.
20mm Solid PVC board plain colour, fixed with screws or adhesive with complete accessaries as in shutters with rebates including shelves ,cupboard etc fixed on PVC soild patten complete all as spd and directed by Engineer in charge. Make : Rajshree, Echon or equivalent as approved by GE
300mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified.
150mm long (Length of Bolt in mm) Aluminium anodised, barrel tower bolts of extruded section and fixed all as specified and directed.
150mm (Size of Handle in mm) Aluminium handles, cast type, anodised all as specified.
100mm Butt hinges (Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed all as specified.
Safety chain in Entrance door fixed with complete fixtures fixed in repair complete all as specified.
Magic eye in Entrance door including filling gaps in door with putty work fixed in repair complete all as specified.
Hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws complete all as specified.
75mm aluminium handle, cast type anodised complete all as specified.
40mm dia cupboard knobs fixed with nut, screw and washer of mild steel bright finished complete all as specified and directed.
2nd class hard wood Plain fillets. square, rectangular or triangular in section, secured with nails or brads. Sectional area exc 3 sqcm n. exc 6 sqcm fixed in repair / replacement complete all as specified.
Drapery rods, powder coated aliminium of 20-25 size with fixing brackets, stops rollers complete all as specified and directed.
Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and also inserted in Cupboard area fixing with cement mortar 1:2 including 20 to 25mm cutting work fixed in repair complete all as specified and directed.
M&L for water proofing treatment to existing RCC roof slab including preparation of surfaces parapet comprising with the following course of treatment/ specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.0 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 160 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. (Note:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instruction. (c ) Applying two coats of reflective Bituminous aluminium paint on top of APP membrane. Laying of Standard APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) including removal existing treatment , complete all as specified and directed by Engineer in Charge.
M&L for 10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, including add WPC @3% of cement weight ( Dr Fixt /Cera /Krishna etc ) , finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Rate includes WPC & Polymeric membrane will be measured and paid separately)
Special treatment of sunken portion of WCs and Bath room as per following stages:Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc .Stage 2:- Providing 10mm thick plaster in CM 1:4 with chemical of Dr. Fixit Pidicrete URP/SIKA /plaster seal of STP Ltd or Equallent Stage 3:- Applying Dr Fixit Primseal primer or STP Ltd(and allow to dry for 8 hours) under touch dry condition Stage 4:- Applying two coats of water proofing of Dr Fixit Pidicrete for the sunken portion of toilets/bathrooms (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufactutrer instruction Stage 5:-Again rendering 10mm thick in CM 1:4 mixed with Dr Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP. Stage 7:- Making holes in wall and fixing 600mm long 25mm dia GI spout for draining the surplus water if any.
Plain cement concrete (1:5:10) type E-2 using 40mm gdd stone agg as in floor filling as mass concrete or in sub base of floors complete all as specified.
Plain Cement concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate min radius of 75mm thick as in roof and parapet wall junction , roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, filling rails embedded sec etc incl necessary sloping on roof top surfaces including form work complete all as specified.
Demolition of unreinforced cement concrete in ground floor and paving n.exc 15 cm thick below or above ground level complete all as specified and directed
75mm Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection,Floor topping etc , surfaces finished of concrete flooring with brooming / checked finish complete all as spd u including provision of necessary construction joints filled with bitumen filler etc complete all as directed by Engr-in-Charge
Taking up or down existing steel water tubing 15mm, 20mm & 25mm bore alongwith connections fixed/laid in any situation complete all as specified
20mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
25mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
Dismantling CI pipe alongwith fitting of 100mm dia or less, below or above ground level jointed in cement mortar and taking out complete all as specified and directed.
S& F in repair PVC (SWR) pipes, 110mm bore, single socketed, 4.00 Kgf per Sqcm pressure, in any length with rubber ring joints complete all as specified and as directed.
S&F 110mm dia bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips complete all as specified and as directed
S& F in repair PVC (SWR) pipes, 75mm bore, single socketed, 4.00 Kgf per Sqcm pressure, in any length with rubber ring joints complete all as specified and as directed
S&F 75mm dia bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips complete all as specified and as directed.
S & F in PVC (SWR) junction single, (Single T) equal or unequal of size 110mm complete all as specified and as directed.
S & F in PVC (SWR) junction single, (Single T) equal or unequal of size 75mm complete all as specified and as directed.
S & F in PVC (SWR) vent cowl of size 110mm complete all as specified and as directed.
S & F in PVC (SWR) vent cowl of size 75mm complete all as specified and as directed.
S & F in 75mm PVC (SWR) floor trap, plain with grating including jointing set to solvent cement and white cement complete fixtures all as spd
S & F in PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete fixtures all as spd
Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified.
Framed work ( Fe 410 -W(Gde-E- 250) quality-A)- as in doors or gates of angle or other section with gusset plates, rails, posts, braces, rafters, purlins etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing as in repair complete complete all as spd and directed by Engineer in Charge.
Supply and fixing of powder coated aluminium section of overall size of outer frame 90mmx34.5mmx1.2mm thickness fixing with gasket, beading, Star lock also Gaps to be filled with weatherproof Silicon Sealant (both sides), and fixing to opening area incl necessary cleats, brackets, screws bolts, Fixed to wall, floor a etc as in repair complete all as specified and as directed By Engineer In Charge
Supply and fixing of powder coated aluminium section of overall size of outer frame 30mmx34.5mmx1.2mm thickness fixing with gasket, beading, Star lock also Gaps to be filled with weatherproof Silicon Sealant (both sides), and fixing to opening area incl necessary cleats, brackets, screws bolts, Fixed to wall, floor a etc as in vantitalor single window complete all as specified and as directed By Engineer In Charge
Supply and fixing powder coated aluminium sliding window shutters, , aluminium section ( 40mm(Ht) x18mm-20mm (W) x1.2mm thickness aluminium Section for window Shutters ) including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No.) or hinges type B-21 100 mm long (2 nos.), suitable handle or Star lock, (1 no.) gasket, Fixing arrangement with Stainless Steel Mesh or Plain glass section . etc as in repair complete all as specified and directed. NOTE : Glass & Wiremesh shall be paid separately
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge complete all as specified and directed.
Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.etc as in repair complete all as spd
1000 Ltr Cap Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with inlet outlet with suitable PVC Float Valve etc connections all as specified in SSR Part I Complete all as spd and as directed by Engineer in Charge.
500 Ltr Cap Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with inlet outlet with suitable PVC Float Valve etc connections all as specified in SSR Part I Complete all as spd and as directed by Engineer in Charge.
S & F in Ball valves high pressure (min 1.5 psi to 2psi)of PTMT with epoxy coated aluminium rod and high density plastic ball ( long/big size ) screwed for iron pipe and fixed for 25mm bore pipe (Minimum weight-455gms), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting existing tanks 500 to 1000 ltr cap, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position with Cleaning, repairing, incl complete connection with inlet and outlet with GI / CPVC pipe fitting, Float valve etc Complete all as spd and as directed by Engineer in Charge.
Cutting into existing sewage line manholes for connecting new drains of any dia of pipe and making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate finished smooth and reforming benching as required for 150mm dia.complete all as specified.
Taking down carefully copper/aluminium point wiring (light/fan, buzzer, socket or power point etc) complete including all fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surface to match with the existing all as specified and directed by Engineer-in-charge.
Taking down carefully main switch /DB with MCCBs/MCBs of any capacity/size etc and making good disturbed surfaces of walls, floors etc including making good the disturbed surface to match with the existing all as specified and directed by Engineer-in-charge.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following:-
One light or fan point controlled by one one way switch
One ceiling fan/exhaust fan controlled by one way switch
One bell point controled by bell push
All as per above item No. 117.00 but wire 1.5 sq mm cable for switch socket outlet 3 pin 5 amps with 1.5 sq mm cable as earth continuity conductor.
All as per above item No. 117.00 but below/parallel the switch board of independent 5 Amps socket in the same vertical/horizontal board.
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 5 pin 5 Amps and all as directed at site.
All as per above item No.120.00 but below/parallel the switch board of independent 5 Amps socket in the same vertical/horizontal plane.
Point wiring with 4 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 3 pin 15 Amps complete all as directed at site.
Switch piano 1 way 6A, 1 module all as specified and directed by EIC.
Ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed.
Ceiling fan electronic regulator five step 02 module, hum free, AC, 230 volts, 100 watts complete all as specified & directed.
Bell push 6A, 1 module 230 volts fixed in repair / replacement complete all as specified and directed.
Buzzer, Ding Dong AC 230 Volts single pole bell complete all as specified and directed.
Taking down existing ceiling fan / exhaust fan any size, any make, refixing the same after replacing the rubber bushes, split pin, servicing, greasing and painting with two coats of synthetic enamel paint (spray painting) complete all as specified and directed.
Supply and fixing ENDURA LINEAR NEO (1200mm) 20 W LED fitting baten fro surface and wall conduit mounting High Transmissitivity diffuser High lumen Output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod , complete all as specified and directed by Engr-in-Charge. Make : Havells No :- ENDURALINEARNEOBS20WLED865SPCWH or equivalent model of make specified in appx 'B' hereinbefore.
Supply and fixing ENDURA LINEAR NEO (600mm) 10 W LED fitting baten fro surface and wall conduit mounting High Transmissitivity diffuser High lumen Output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod , complete all as specified and directed by Engr-in-Charge. Make : Havells No :- ENDURALINEARNEOBS10WLED865SPCWH or equivalent model of make in PHILIPS/CG.
Supply and fixing LED lights fitting 20W, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED down lighter, 6W, Ultra sleek recessed downlight for low height false ceiling in square profile 220V, AC decorative box type with driver, holder including connecting up with three core flexible copper conductor cable of suitable complete all as specified and directed by Engr-in-Charge.
Supply and fixing fully diffused surface / recessed mounted 2x2 LED light luminaire with high transmitive diffuser suitable for indoor spaces 36W, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps fixed in repair / replacement complete all as specified and directed.
Supply and fix TPN DB's 4 way vertical double door including 100/63 Amps MCCB 4 pole as in main incomming fixed in repair complete all as specified and directed.
Supply and fixing MCCB, AC 415 V, 50 HZ, fixed type, capacity 100 Amps, 3 Pole, 16 KA, suitable to be fixed in 4/6/8 way TPN DB fixed in repair / replacement complete all as specified and directed.
S & F in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar complete all as specified and directed.
S & F in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar complete all as specified and directed.
TPN and vertical loadline 4 way double door suitable for G frame MCCB DBs are fitted with Bus Bars, Neutral Links, Blanking Plates with incomiing MCCB 100 Amp -01 N, (4 Pole, 35 KA breaking capacity Fixed Thermal & Fixed Magnetic setting Ics = 50% of Icu) and Outgoing MCB Tpn 63 Amp -3 Nos connected with duly wire fitting on wall and smooth finishing after fixed in repair / replacement complete all as specified and directed. Make :- Havells Cat No :- DHDLVDRWGOFO04 or equivalent cat part of makes specified here-in-before.
MCB SP 6-32 Amps,10 KA breaking capacity suitable for 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge.
MCB SP 415 Volts AC 63 Amps of breaking capacity 10 KA fixed in repair / replacement complete all as specified and directed.
MCB SPN 63 Amps, 10 KA breaking capacity suitable for 415 V, 50 Hz AC complete all as specified and directed by Engineer - in - Charge.
MCB SP 240 Volts AC 40 Amps of breaking capacity 10 KA fixed in repair / replacement complete all as specified and directed.
MCB SPN 40 Amps, 10 KA breaking capacity suitable for 415 V, 50 Hz AC complete all as specified and directed by Engineer - in - Charge.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 25x4mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 32 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion,as in replacement, complete all as specified and directed.
Earthing continuity galvanised iron strip 25 x 4 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
Sub main wiring concealed with 4 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduet shall be measured and paid separately).
Sub main wiring concealed with two runs of single core 6 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 6sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduet shall be measured and paid separately).
Sub main wiring concealed with 10 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including 10 sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduet shall be measured and paid separately).
20 mm rigid non-metallic PVC concealed conduit medium grade including all PVC conduit accessories, cutting / chases and making good disturbed surfaces complete all as specified and directed.
Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 10 sqmm 4 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Supply laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
25mm bore galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions) and fixing complete with clips, wall hooks, wooden plugs or laying in trenches also cutting, screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting complete all as specified and as directed.
Making hole for cable in existing LT panel and making arrangement and S&F MCCB 4 pole 415 volt, 63 Amp AC 50 Hz, of breaking capacity 16 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment (Ics=100% of Icu) for connecting of LT cable including enclosure box for housing MCCB with all accessories complete all as specified and as directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pipe line, cable, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete as specified.
Removing excavated material (soil/ rock) to distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point,complete all as specified and directed.
Fine dry river sand cushion in trenches for cable protection with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Note :- Only compacted thickness will be measured and paid.
Unreinforced precast concrete cable cover, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
Cutting of hard standing/ Road up to 30cm wide and 45cm in depth for laying of pipe line/cable and making good surfaces by using 100mm thick PCC 1:2:4 type B-2 over hard core 150mm thick over rammed earth after laying of pipe line/ cable and removing rubbish outside MD land complete all as specified and as directed.
AADESH CONSTRUCTION
OM ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .