| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹19.5 L+₹44,450 (2.33%)Rejected-Finance 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹21.4 L+₹2.3 L (12.0%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹22.3 L+₹3.2 L (17.0%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹23.9 L+₹4.8 L (25.3%)Rejected-Finance PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2023_MES_588191_1
GE MAINT EZHIMALA 8552
Open Tender
Civil Works
Item Rate
330 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹60,000
Yes
13 Jun 2023
4 Apr 2023
3 May 2023
4 Apr 2023
1 May 2023
18 Apr 2023
5 Apr 2023 - 12 Apr 2023
Amount
Notes for all items of BOQ :- 1. The contractor should visit the site before quoting the tender to know the exact working condition of the station. 2. All requisite safety measures to be adopted by contractor on site. 3. The contractor shall provide and deploy sufficient electrician ( as approved by GE/ Engineer in charge) shall report at 9.00 hrs to JE E/M / Engineer in charge to collect the complaints job card in working days and complete the same complaint within 24 Hrs. 4. The complaints shall be rectified within 24 Hrs, if the complaints is/are not attended / not completed with in 24 Hrs ( except repair/replacement of major items) recovery will be done at Rs. 500 per complaint per day. 5 For major parts like rplacement of MCB,DBs,MCCBs etc should be rectified within 3 working days, if the contractor not rectify within time then the recovery will be done at Rs 1000 per complaint per day. 6. After completion of Job work complaint, the contractor has to produce job card duly signed by user & JE /Engineer in charge. 7 If contractor failed to provide their electrician or attend the complaints then recovery will be done at Rs 1000 per day.
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete including fittings such as switches ceiling roses, pendent, regulators, sockets, etc including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
M&L for color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC casing and caping suitable size modular metal flush box/PVC box fitted with modular cover plate with frame (inner/ outer plate) for mounting switches,sockets,regulators etc including FRLS 1.5 sqmm earth wire copper insulated connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge for the following:- Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral and earth conductor. (iii) The wiring shall be done strictly by following proper colour coding using red , blue, yellow for phase, black for neutral and green for earth leads. (iv) Size of copper earth wire must be equal to size of current carrying conductor upto size 16 sqmm.
(a) One light/ fan point controlled by one switch.
(b) One 3 pin socket outlet 5 Amps on the same board with other switches.
(c) 5 Amps socket point on independent board.
All as per item no 3 here in above but 2.5 sqmm for 15 Amps socket on independant board complete all as specified and directed by Engr-in-charge.
M&L in replacement of old unserviceable sub main wiring color coded using 2 runs of 2.5 sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through PVC casing caping along with 1 run of 2.5 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring and making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of old unserviceable sub main wiring using 2 runs of 4 sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing caping along with 1 run of 4 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring and making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of old unserviceable sub main wiring using 2 runs of 6 sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing caping along with 1 run of 6 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly complete ncluding taking down the unserviceable wiring and making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Notes for item No.5 to 7 :- (i) One run of PVC casing and caping alongwith 3 runs of respective size of PVC insulated copper conductor cable with necessary accessories will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase,black for neutral and green for earth. (iii) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.
M&L in replacement of old unserviceable sub main wiring color coded using 2 runs of 2.5 sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through existing conduit along with 1 run of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly, including taking down the unserviceable wiring and making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of old unserviceable sub main wiring using 2 runs of 4 sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including existing conduit along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring and making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of old unserviceable sub main wiring using 2 runs of 6 sqmm FRLS PVC insulated cupper conductor 1100 Volts grade conforming to IS specification drawn through and including existing conduit along with 1 run of 6 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring and making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Notes for item No.8 to 10 :- (i) 3 runs of respective PVC insulated copper conductor cable with necessary accessories will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase,black for neutral and green for earth. (iii) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.
M&L in replacement of old unserviceable switch, piano, flush mounting type, single pole, one AC 230V grade 5Amps ISI marked including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
All as per item No.11 here in above but 15 Amp ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable socket outlet 5 amp multi pin type ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable socket outlet 3 pin15 amp multi pin type ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable fan regulator electronic step up type 100/120 Watt AC 230 watts including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable ceiling rose 3 pole 240V PVC/Poly carbonate insulated body ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable modular switch one way 6 Amps 1 module ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable modular socket 6 Amps 2 module multi pin ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable modular switch one way 16 Amps 1 module ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable modular socket 16 Amps 2 module ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable white cover plate2/3/4 module including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable switch socket combination 5/16 Amps 5 in one flush type ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable MCB single pole AC 240 Volts, 6 to32 Amps C-Series including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable MCB single pole & neutral, AC 240 Volts, 32 Amps C-Series including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable MCB triple pole & neutral, 40 Amps, 415 Volts AC, C-Series including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable RCBO's for earth leakage protection double pole 300 mA, 40 Amps including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable modular AC Socket with MCB single pole 25/32Amps C-Series, AC 240 Volts including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable lamp holder, PVC type suitable for pendent/batten fittings including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable condenser 4 mfd, AC 440 Volts suitable for exhaust fan including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable condenser 2.5mfd, AC 440 Volts suitable for ceiling fan/exhaust fan including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable fan regulator(Modular) electronic step up type 100/120 Watt AC 230 Volts including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable hylam sheet 3 mm thick suitable for switch boards etc including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable LED lamp 10 Watt B 22 suitable for batten/pendent holder including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge. Make:- Havells/Crompton/Philips/Bajaj/Wipro.
S&F in replacement of old unserviceable MCB DB SPN 240V double door outdoor type, 12 way with bush bar of appropriate current carrying capacity, neutral link, earth bar and din rail including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable MCB DB TPN 415V double door type, 6 way with bush bar of appropriate current carrying capacity, neutral link, earth bar and din rail including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable decorative ultra slim round profile 1 feet 5Watt output lumens greater than 110 lumens /watt,efficiency 110 lumen/watt, life 30000 hrs, surge protection 2.5Kv, power factor > 0.98, THD 20% LED lighting with extruded poly carbonate ready to use pack making connection to existing ceiling rose to fitting with 3 core, 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Havells. Model No. ELITE PRIDE PLUS 5W LED 6000K or equivalent in Philips/Wipro/Havells/Bajaj Note:- LM79 report accredited by NABL certified lab should be submitted.
S&F in replacement old unserviceable wall mounted 10 W 2 ft LED batten, out put lumen ≥ 100 lumen/watts, CCT ≥5500k, efficacy 100 lumen per watt, life 50,000 burning hrs, aluminum body, surge protection 4kV, power factor ≥ 0.95, THD ≤10%, extruded channel in thermally conductive material for efficient heat dissipation with Polycarbonate diffuser and integrated electronic driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton model No. CCS-103-10-65-SL-DP-NWH or equivalent in Philips/Wipro/Havells/Bajaj. Note:- LM79 report accredited by NABL certified lab should be submitted.
S&F in replacement old unserviceable wall mounted 20 W 4 ft LED batten, out put lumen >110 lumen/watts, efficiency 120lumen per watt, life 50,000 burning hrs, aluminum body, surge protection 4kV, power factor > 0.98, THD <10%, extruded channel in thermally conductive material for efficient heat dissipation with Polycarbonate diffuser and integrated electronic driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton Model TRIM LINE NEU CCS-103-20-65-SL-DP-NWH or equivalent in Philips/Wipro/Havells/Bajaj. Note:- LM79 report accredited by NABL certified lab should be submitted.
S&F in replacement of old unserviceable LED down lighter fitting 12W with round shaped output lumen greater than 110 lumen/watt, efficiency 110 lumen/watts, life 50000 burning hrs, surge protection 4Kv, Power factor >0.98, THD≤10%, CRI ≥80 surface mounted and high translucent frosted plastic diffuser makes it a robust luminaire efficacy 100lm/w with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model PEARL NIOS-R-LCDSPLN-R-12-CDLor equivalent in Philips/Wipro/Havells/Bajaj. Note:- LM79 report accredited by NABL certified lab should be submitted.
S&F in replacement of old unserviceable LED down lighter fitting 18W with round shaped out put lumen greater than 110 lumen/watt, efficiency 110 lumen/watts, life 50000 burning hrs, surge protection 4Kv, Power factor >0.98, THD≤10%, CRI ≥80 surface mounted and high translucent frosted plastic diffuser makes it a robust luminaire efficacy 100lm/w with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model PEARL NIOS-R-LCDSPLN-R-18-CDLor equivalent in Philips/Wipro/Havells/Bajaj. Note:- LM79 report accredited by NABL certified lab should be submitted.
S&F in replacement of old unserviceable LED bulk head fitting 10W output lumen greater than 110 lumen/watts, efficiency 110 lumen per watt, life 50000 burning hrs, surge protection 4Kv, power factor >0.98, THD <10%, CRI ≥80 , IP 65 surface mounted LED, PMMA diffuser, powder coated white finish housing with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model STUD- LBHP-10-CDL or equivalent in Philips/Wipro/ Havells/Bajaj. Note:- LM79 report accredited by NABL certified lab should be submitted.
S&F in replacement of old unserviceable surface mounted 18W luminaire 1x1 tile, output lumen greater than 110 lumen/watts, efficiency 110 lumen/watts, life 50000 burning hrs, surge protection 4kV power factor >0.98, THD≤10%, CRI ≥80 glare free uniform illumination housing with opel diffuser with colour temp 6000K with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model PEARL NIOIII- S-LCTLSNE-18-FO-CDL or equivalent in Philips/Wipro/Havells/Bajaj. Note:- LM79 report accredited by NABL certified lab should be submitted.
S&F in replacement of old unserviceable recess mounted 36W luminaire 2x2 tile, output lumens greater than 110 lumen/watt, efficiency 110 lumen per watt, life 50000 burning hrs, surge protection 4kV, power factor>0.98, THD≤10%, CRI ≥80, glare free uniform illumination housing with opel diffuser with colour temp 5700K with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model PolarisNIO I LCTLRNE-36-FO-CDL or equivalent in Philips/Wipro/Havells/Bajaj. Note:- LM79 report accredited by NABL certified lab should be submitted.
S&F in replacement of old unserviceable surface mounted 36W luminaire 2x2 tile, output lumens greater than 110 lumen/watt, efficiency 110 lumen per watt, life 50000 burning hrs , surge protection 4kV, power factor>0.98, THD≤10%, CRI ≥80, glare free uniform illumination housing with opel diffuser with colour temp 5700K with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model Polaris NIO III I LCTSNE-36-FO-CDLor equivalent in Philips/Wipro/Havells/Bajaj. Note:- LM79 report accredited by NABL certified lab should be submitted.
Benchmark Engineers and Contractors
LUCKY ENTERPRISES
JEETH CONSTRUCTION
Gates Infra Construction Co
KDR CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .