Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹96.3 LAccepted-AOC D NO 50 53 2 5 FLAT NO 504 SRI SAI VENKATESWARA RESIDENCY NE LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | 1 | Accepted-AOC Being Lowest Bidder | |
| 2 | 2₹1.1 Cr+₹13.6 L (13.6%)Rejected-Finance D NO 58 18 78 1 SRIVARI NILAYAM 2ND FLOOR NEAR NSTL MAIN GATE BUTCHIRAJUPALAM VISAKHAPATNAM 530 027 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530027 | 2 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹86 L
EMD Value
₹1.5 L
Closing Date
12 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Provision of Catwalk for Safety and Maintenance of HQ ENC Building and Addition Alteration of Building No. P - 45 at INS Circars, Visakhapatnam
2021_MES_473535_1
82182 / E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class C
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹1.5 L
Yes
5 Nov 2021
7 Sept 2021
19 Oct 2021
7 Sept 2021
12 Oct 2021
28 Sept 2021
7 Sept 2021 - 14 Sept 2021
60 days
Amount
Excavation over areas not exceeding 1.50m in depth and getting out in Soft / Loose soil complete all as specified and as directed.
Excavation over areas exceeding 1.50m and not exceeding 3.00m in depth and getting out in Soft / Loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance exceeding 1.50 KM and not exceeding 5.0 KM and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
M & L for Crusher Dust / Stone Dust / M-Sand filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for RCC M–30 Design Mix, using 20mm graded stone aggregate as in Foundations including Pile Caps, Rafts, Footings, Foundation Beams, Plinth Beams, Bases for Columns, Fillings, Mass Concrete, etc. complete all as specified and as directed.
M & L for Use and Removal of Steel Formwork to sides of Concrete Foundations, Pile Caps, Footings, Bases of Columns, Raft and Raft Beams, sides and soffits [if any] of Foundation and Plinth Beams and similar work, Vertical or to Batter for rough finished surfaces complete all as specified and as directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Columns, Pillars, Piers, Posts and struts etc. complete all as specified and as directed.
Use and removal of Steel Formwork to Sides of Pillars, Posts, Struts, Piers, Columns and Stanchions of any Shape / Cross Section for Fair Finished surfaces of concrete complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F MS machine made screw bolts with hexagonal or square head one end and screwed other or screwed both ends, fitted with washers and one hexagonal or square nut not exceeding 5 cm long, dia of neck exceeding 16 mm but not exceeding 20 mm complete all as specified and as directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Plates [Plain & Chequered], Channels, Angles, square cut or notched [ordinary or counter sunk] forming holes without any attachment including fixed with Nut and Bolt / welding complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Main and Cross Beams, Hip and Jack Rafters, Purlins where connected to common rafters, and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Stairs [Framed] including Stringers, Treads, Landing, Balusters, Hand Rails etc including cleats, brackets, etc complete all as specified and as directed.
S & F Aluminium Composite Panel sheet of 3 mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30 micron fixed with suitable Self Tapping Screws over frame work of anodised aluminium tubular section 25 X 50mm, 2mm thick, duly fixed to wall / ceiling with expansion fastener, having panels not exceeding 1200X1200mm with necessary silicon filling, in approved pattern / size as in column, beam, wall etc. complete all as specified and as directed. Note:- Rate quoted is deemed to be included for necessary MS Scaffolding up to a height of 12m from the GL for carrying out the job. Nothing shall be paid extra on this account. [Make of Aluminium Composite Panel: ALSTRONG / ALCOBOND / ALSTONE] [Make of Aluminium Sections: JINDAL / HINDALCO / INDAL]
S & F for pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm or Tiled Profile or Sinusoidal Profile and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer.
S & F Zinc Plated Carbon Steel Hilti Chemical Anchors of 16mm to 20mm dia, 200mm long inserted in to Column / Beams, fixed with injectable chemical anchor complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 21 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 21 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1000 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB, SPN, 40 to 63 Amps, 10 KA, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, AC, 230 Volts, 50 Hz complete all as specified and as directed.
N Sydeswara Rao
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .