| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L1 | Accepted-AOC The letter of Acceptance of tender | |
| 2 | L2₹16.5 L+₹2.1 L (14.8%)Rejected-Finance | L2 | Rejected-Finance Not the lowest e-tenderer | |
| 3 | L3₹17.6 L+₹3.2 L (22.5%)Rejected-Finance | L3 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
13 Aug 2022, 6:00 pmClosed
Shri T Rajasekharam,IDSE
HQ Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
SPECIAL REPAIRS TO BLDG NO T 2 AT SUPPLY POINT UNDER GE DEHU ROAD
2022_MES_538987_1
84076/DR/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Dehu Road
Please ref Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Dehu Road
₹39,000
12 Dec 2022
18 Jul 2022
15 Aug 2022
18 Jul 2022
13 Aug 2022
1 Aug 2022
18 Jul 2022 - 6 Aug 2022
Amount
Dismantling plain or corrugated steel sheeting any gauge, any thickness including Nainital or similar pattern roof covering , in wall clading and velley gutters & removing clear off site after credit for the same is recovered by Dept complete all as specified and directed.
Dismantling of wrought iron or mild steel work any description and fixed in any position & removing clear off site after credit for the same is recovered by Dept complete all as specified and directed.
Demolition of brick work built in cement mortar & removing clear off site after credit for the same is recovered by Dept complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing PVC water tanks of capacity 500 litres, setting aside (or lowering if required) for replacement & removing clear off site after credit for the same is recovered by Dept complete all as specified and as directed.
Taking out existing water proofing treatment including cement plaster(any no of layers) on roof surfaces, cleaning the surfaces and removing the debris outside MOD land complete all as specified and as directed.
M & L for providing 25 mm thick PCC 1:2:4 type B1 ( using 20mm graded stone aggregates ) as in filling in levelling course over roof slab complete all as specified and directed.
Extra over rendering for work in isolated width such as in bands, sunk panels, cornices, skirting sides of slabs, parapet sides and top drip moulds etc and similar work not exc 15 cm width or girth complete all as specified and directed.
M & L for cleaning the plastered / concrete surfaces with wire brushes and applying water proofing treatment as under :- (a) Apply one coat of oil bituminous primer @ 0.20 kg/SQM over concrete surface. (b) Laying APP Polymerised modified membrane not less than 3 mm thick and weighing not less than 3.5 kg per SQM by torch applicaton method. (c) The overlap for APP membrane shall be 75 mm on longitudinal direction and 100 mm on transverse direction. (d) Finally applying a coat of solar reflective bitumiious aluminium paint @ 0.15 Kg/SQM over the membrane. (e) The make / treatment shall be from the one of the following manufacturer:- (i) 'Moply FP' of M/s Texsa (I) Pvt Ltd. (ii) 'Hyperplast' of IWL India Ltd. (iii) 'Super thermpay' manufactured by M/s Shalimar tar product (iv) 'Hydroflame' of M/s Hydrotech Ltd.
S & F rotational moulded polyethylene double layered water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe spouts for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
M & L rolled sections as in main and cross beams, hip rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed witjh angle cleats or other connecting plates Fe 410 W (gde E 250 ) quality A including a shop coat of zink chromate primer complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks,straight or curved on plan, exc 6m mean redius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
S & F 0.50mm thick pre painted/coloured galvalume aluminium zinc coating GI based corrugated steel sheet of any colour in roofing having tensile strength 550 Mpa fixed with self tapping screws all as specifeed.
All as per item No. 12 above but plain sheet in valley gutter / ridge complete all as specified and as directed.
Dismantling wall & ceilling boards(fibre pulp insulation etc) or insulation boards/ slabs/blankets, any thickness including cover fillets & removing clear off site after credit for the same is recovered by Dept complete all as specified and as directed.
S & F 12mm thick Gypsum board for ceiling, insulation and accoustic purpose 60x60cm in size fixed with screws with staples incl aluminium snap grid frame work 605x605 mm in flat/slopting ceiling with aluminium anodised grid work 35.60x23.60x1.60mm main Tee 23.60x23.60x1.60mm cross section and 26x26x1.60mm angle including 3mm dia GI wire suspender of suitable length aluminium cleats etc complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing of 15 mm bore of pipe complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing of 20 mm bore of pipe complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth
M & L for 15 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
M & L for 20 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
S & F in repairs ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore and fixed (minimum weight 210 gms ) complete all as specified and as directed.
S & F in repairs 15 mm dia stop valves, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or union fixed for 15 mm dia GI pipe all as specified and as directed.
S & F in repairs 15 mm dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass furrule and fixed for 15mm dia pipe complete all as specified and as directed.
S & F in repairs 15 mm dia pillar taps, fancy type, cromium plated with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15 mm dia pipe complete all as specified and as directed.
S & F in repairs 15 mm dia Brass cromium plated shower rose of 125 mm long leg complete all as specified and as directed.
S,&,F in repairs,Grating round 100 mm size of PTMT (Minimum weight 25gms.) complete all as specified and as directed.
S & F in repairs Vitreous china wash basin white flat back size 550 x 400mm including , waste pipe and plug and porcelain stopper and brackets incl cutting for and pinning in ends of brackets or erecting stand along with 32mm dia CP waste coupling and PVC waste pipe complete all as directed.
S & F in repairs for PVC connection pipe 15mm dia with PTMT nuts of length 450mm complete all as specified and as directed.
S & F in repairs PVC low/high level flushing cistern white 10 litre capacity incl PVC inlet pipe with brass check low level full both sides along with PVC flush pipe 32mm dia jointed to WC and handle incl brackets all as directed.
S & F in repairs vitreous china wash down water closet pan (pedestal pattern) of size 580x440 white with 'P' or 'S' trap including connection to drains (or outgoing pipes) and to the flushing pipes, complete all as specified and directed.
S & F in repairs PVC (SWR) pipes, type B, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm dia complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 110 mm dia PVC (SWR) bends, any radius with access door complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) & removing rubbish outside MD land complete all as specified and directed.
M & L non skid coloured ceramic tiles 7 to 8 mm thick area of EACH tiles exceeding 0.06 SQM but not exceeding 0.11 SQM , in floors, etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match Including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete.
M & L for vitrified coloured tiles 10mm th (square/rectangular), area of EACH tile 0.36 SQM but n exc 0.42 SQM in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles over 15 mm th screed bed in CM 1:6 complete
Ditto as per item No 37 above but on skirting over 10 mm th rendering in CM 1:4 complete all as specified and directed.
M & L Glazed ceramic tiles on vertical surface 450mm x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles incl backing coat 10mm thick in CM 1:4 all as direced.
Demolition of cement concrete ( unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) & removing rubbish outside MD land complete all as specified and directed.
M & L for cement concrete Type C2 1:3:6 (using 40mm graded aggregates) as in plinth protection 75 mm thick finished top surface even and smooth without using extra cement complete all as specified and as directed.
M & L for 75 mm thick Cement concrete type D-2 1:4:8 (40 mm graded aggregate) as in sub base complete all as specified and as directed.
M & L laying 25 mm thick sand cushion on bed for paver block including spreading levelling in layers for fixing of Paver blocks complete all as specified and directed.
M & L for precast concrete interlocking paver block,rubber moulded any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade with grey cement and pigment complete all as specified and as directed.
M & L for Chequered cement concrete tiles of 30 cm x 30cm x 25 mm thick with grey cement and pigment,set and jointed in neat cement slurry in floors including 15 mm thick screed bed or bedding layers in cement mortar 1:6 for laying tiles complete all as specified and as directed.
Taking down chowkhats or with shutter (without taking off shutter from the frames), exc. 1.5 SQM but n. exc. 4 SQM EACH & removing clear off site after credit for the same is recovered by Dept complete all as specified and directed.
–Ditto- as item No 46 above but n.exc. 1.50 SQM EACH
Taking down steel window/ventiltors of any size & removing clear off site after credit for the same is recovered by Dept complete all as specified and directed.
S & F for pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 125 X 60mm
M & L for PCC 1:2:4 type B1 in door frame filling all as specified and directed.
S & F factory made 35 mm thick glazed & skeleton shutter of 2nd class hard wood open rebated and prepared to receive gauge (divided into squares with sash bars) edges of framing plain chamfered or rounded, fitted without & fitted beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I Sec-8 clause 8.23 (b) and fitted to chowkhats complete all as specified.
S & F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.00mm fixing to steel window with nut bolt.
S & F aluminium powder coated window sliding type (3 track) with frame size100x35x1.2mm and shutter 39.40x17.70x1.2mm with two glass shutter & one mesh shutter incl necessary jointing cleats glazing clips, rubber packing,and locking arrangement powder coated aluminium snap beading screws including 4mm plain float glass & 0.36 mm dia and 1.4 mm width of aperture SS wire mesh, fittings etc complete all as specified.
S & F in repairs curtain rod 25 mm dia anodised aluminium alloy, powder coated fancy type complete with side knobs all as specified and directed. Note- Brackets shall be measured & paid seperately
S & F in repairs brackets fancy type powder coated for 25 mm dia curtain rod complete all as directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
S & F factory made PVC solid panel door shutter 30mm thick (style) connecting of frame made out of MS tube for top and bottom rail. MS frame shall be coverd withheat moulded plain coour PVC 'C' channel having a PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail of either side and as gap insert for toprail and bottom rail panellinn of plain colour PVC to be fitted in the ms frame welded/ sealed in the stiles and rail with suitable PVC sheet and loading and jointed together with solvent cement, supplying and fixing in the frame at site all as directed by Engineer -in -charge.
S & F 150 mm size extruded aluminium alloy handles,fabricated type anodised.
S & F aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 150mm
S & F aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 100mm
S& F 100 mm Butt hinges, stainless steel, bright polished and fixed, type B-11 all as specified and directed
S& F 150 mm Butt hinges, stainless steel, bright polished and fixed, type B-11 all as specified and directed
S & F 250 mm long aluminium alloy anodised sliding door bolts with hasp,staple(bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolt of extruded section or cast aluminium alloy complete all as directed and specified
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. & removing rubbish outside MD land complete all as specified and as directed.
M & L for rendering cement plaster 10 mm thick in CM 1:6 on fair faces of brick walls finished even and smooth w/o using extra cement complete all as specified and as directed.
M & L for rendering cement plaster 15 mm thick in CM 1:4 on fair faces of brick work or conrete wall surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M & L for Preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper on walls over a coat of primer on plastered surfaces complete including 3mm thick wall care putty complete all as specified and as directed.
M & L for Preparation of newly plastered surfaces of wall and applying two coats of cement base paint on walls over a coat of primer on plastered surfaces complete all as specified and as directed.
M & L for preparation for two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces of 10cm width or girth.
M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a red oxide primer complete all as specified and directed.
Complete removal of existing treatment from old decorated surfaces of walls preparation of surfaces and applying two coats of distemper oil emulsion over including a coat of alkali resistant primer complete all as specified and directed by Engineer - in - Charge.
Complete removal of existing treatment from old decorated surfaces of walls preparation of surfaces and applying two coats of cement base paint complete all as specified and directed by Engineer - in - Charge.
M & L applying one coat of white wash on old decorated surfaces of ceiling including preparation of surfaces complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-Charge.
Taking down carefully old/ damaged/unserviceable copper/ aluminium pointwiring (light, fan, socket or power) complete, (fittings such as switchs, ceiling roses, pendents, regulators sockets etc. to be measured seperately), removing materials to store for keeping insafe custody for ruse at site and making good disturbed surfaces of wall, floors etc. comlete all as specified.
Taking down of unserviceable main switches ,DBs along with teak wood boards etc and making good surface of walls/floors to match the existing surfaces all as specified.
M & L for point wiring complete including single core PVC insulated and unsheathed type flexible bright unsheathed multi stranded 1.5 SQM copper conductor FRLSH in and including PVC casing caping or surface/concealed PVC Conduit and accessories having ISI Mark to be fixed with proper screws (MS Steel strips if required) including all accessories/ fitings/ junction boxes/ inspection covers etc including hard PVC board of required side fixed with wall surface by means of brass screws and sunk/cupwasher, for mounting of switches fan regulators etc including 1.5 SQM (22/0.30mm) 1100 V grade PVC insulated, unsheathed flexible multi stranded copper conductor FRLSH cable as continuous earthwire connected to metallic bodies of luminaries/fans etc. at one end and to common earth duly at other end and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and applying two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point controlled by one switch complete all as specified and directed by Engineer-in- Charge
- do same as Item No. 77 above but for One fan/exhaust point controlled by one switch & regulators
- do same as Item No. 77 above but for One socket 5 pin 5 Amps flush type on independent board
- do same as Item No. 77 above but for One socket 5 pin 5 Amps flush type on same board
- do same as Item No. 77 above but for but for one socket point on independent board, 15 Amp with 2.5 sq mm PVC unseathed FRLSH wire along with 2.5 sq mm FRLSH green colour wire as earth continuity conductor connected to common earth dolly complete all as specified & as directed by engr-in-charge. Note for Item No. 77 to 81:-color coding to be followed as given R-Phase,B-Neutral & G- Earthing
S & F switch piano, flush type, single pole, one way, 5 Amps
S,&,F socket Out let, 2 in 1, 5 Amps, flush type
S & F switch socket combination 2 in 1, 15 Amps, flush type
S & F ceiling rose, surface type, 65 X 50mm, isolated body with 3 terminals, to be fixed on PVC block
S & F regulator, electronic step type, for ceiling fans suitable for AC 230 volts 50 Hz 1200 / 1400mm sweep
S & F MCB DB SPN sheet metal enclosure,double door suitable for mounting MCB 240 volts with 200 Amps rated busbar 8 way
S & F isolator, SPN, 40 Amps, 240 volts
S & F MCB, SP, 240 volts, 6-32 Amps
S & F in replacement of 2 feet 10 W linear aluminium LED batten with white acrylic cover complete with all accessories prewired and connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fixing LED lights fitting 1x 16W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
M& L for taking down ceiling fan/exhaust fan, sealing cable end,dismantling blades and removing fan and blades to store
S & F ceiling fan,1200mm sweep, BLDC (Brushless Direct Current), 5 star Rated, AC, single phase,230 Volts and connecting up including provision of flexible wire 23/0.0076 size, three core, 1100 Volt, twisted, PVC insulated, copper conductor, multistranded for connection from ceiling rose or connector to fan complete all as specified and as directed by Engr-in-Charge.
S & F exhaust fan, AC, single phase, 230V, 300mm sweep, 1400 RPM, single phase with double ball bearing , 5 blade, metallic robust rust proof body & blade with louver for protection of bird and rain water including cutting round shape in wall, grouting the foundation bolt in the wall, making good the disturbed surfaces of wall including rendering, painting to match the existing surfaces and connection with three core copper flexible wire 23/0.0076 from ceilling rose/connector to fitting complete all as specified and as directed by Engr-in-Charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element 2 KW capacity 25 litre, BEE 5 Star rated complete with all ccessories such as safety valve, thermostate,NRV, connection piece etc.
S & F and commissioning LED Security/street light fittings , 35 watts, 2500 lumens luminaire fixture in IP 65 protection level with aluminium pressure die cast reflector with heat shrink LM6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours and including suitable GI bracket made out of 40mm GI pipe heavy grade of approximate length 2mt, bent to shape and fixed on wall with MS clamps of size 32 x 6mm, 02 Nos nuts, bolts, wshers etc per clamp complete with all accessories internally pre-wired and including provision of flexible wire 23/0.0076 size, three core, 1100 Volt, twisted, PVC insulated, copper conductor, multistranded for connection from ceiling rose or connector to light fitting including painting of clamps with two coats of aluminium paint over a coat of approved prime complete all as specified and as directed by Engineer-in-Charge.
M & L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.75m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to using galvanised iron wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron. Earth strip protected by GI pipe of size 20mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, CI frame and cover with locking arrangement , funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
S & F in repairs GI tubing 20mm bore, medium grade with all fittings conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 , laid in trenches complete all as specified and directed by Engg-in-charge.
S & F in repairs GI tubing 25mm bore, medium grade with all fittings conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 , laid in trenches complete all as specified and directed by Engg-in-charge.
S & F in repairs GI tubing 40mm bore, medium grade with all fittings conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 , laid in trenches complete all as specified and directed by Engg-in-charge.
S & F in repairs Gun metal gate valve 20mm dia with iron wheel head screwed both ends for iron pipe and fixed in position complete all as specified.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in Soft / loose soil all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in hard/dense soil all as specified and directed.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material, not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.
M & L for MS Work including cutting,welding,other process for shaping of material to get into required shape as per site requirment and fixing on site. Note: Earthwork will be measured and paid separately
Dismantling/ disconnecting LT cables of any size with accessories.old unserviceable of any type broken or damaged cables fitting on poles/laid in trenches and keeping aside for further disposal.
Supply, laying, jointing , testing and commisioning XLPE cable 1100 volts grade PVC insulated armoured & PVC sheathed with stranded aluminium conductor heavy duty ISI marked incl cable glands lugs bolts nuts washers etc to suit the cable size 16 SQMm 2 core as directed by engineer in charge
M & L for HDPE DWC pipe 50 mm outer dia, ISI Marked, fixed on walls, ceilings or in floors, trenches etc. for cable protection of the following outer dia :- Make:-Infra/Supreme/Prince
M & L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) complete all as directed by Enger -in- charge.
H S TAKHI
AVS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .