Loading…
Loading…
Tender Value
₹4.4 Cr
EMD Value
₹4.5 L
Closing Date
7 Sept 2026, 6:00 pm
Executive Engineer office, Dang (R&B) Division, Ahwa
Construction Of New R&B Division & Sub Division Office At Ahwa, Dist: Dang.
334790
06 OF 2026 - 27
Open
Civil Works - Buildings
Works
Dang
18 documents required · 16 mandatory · 2 optional
₹6,000
Executive Engineer, Dang (R&B) Division, Ahwa
₹4.5 L
14 Aug 2026
14 Aug 2026
14 Aug 2026
7 Sept 2026
14 Aug 2026
No figures
1 Excavation for foundation upto 1.5 m depth including 1091.00 Cumt 125.86
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter
lead.(A) Loose or soft soil
2 Excavation for foundation for depth from 1.5 m to 3.0 618.00 Cumt 309.04
m including sorting out and stacking of useful
materials and disposing off the excavated stuff upto
Meter lead. (D) Soft rock not requiring Blasting
3 Filling in foundation and plinth with sand in layers of 106.00 Cumt 489.28
20 cm. Thickness including watering ramming and
consolidating etc. comp.
4 Filling available excavated Earth (Excluding Rock) in 1048.00 Cumt 137.47
trench plinth side of foundation . in layer not excluding
20 cm in depth consolidation each deposited layer by
ramming and watering etc. complete
soil in layer of 20 cm in thickness including ramming
watering and consolidating etc. complete
6 Applying general insecticide pest control treatment to 497.00 Sqmt 54.04
floors, cupboards etc including labour materials etc.
complete. Using Imidacloprid 30.5 SCas Per IS
part -II( (0.075% concentration by mass) is
recommended 10.5ml chemical diluted with 5 liters of
water application 0.5 litre chemical /Sqm of surface is
recommended as per I.S.
7 Providing and laying controlled cement concrete 189.63 Cumt 4048.90
M.150 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (A) Foundations and plinth pcc
8 Providing and laying controlled cement concrete 300.50 Cumt 5016.67
M.250 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (A) Foundations, footings, and Mass
concrete. footing
9 Providing and laying controlled cement concrete M- 27.00 Cumt 8443.60
250 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in (d) columns Up to Plinth
10 Providing and laying cement concrete 1:3:6 (1-Cement 28.00 Cumt 3106.67
: 3- coarse sand : 6- machine cut stone aggregates
mm nominal size) and curing complete excluding cost
of formwork in (A) Foundation and Plinth
11 Providing and laying controlled cement concrete M- 54.70 Cumt 8362.80
200 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars posts and
struts G.FLOOR
12 Providing and laying controlled cement concrete M- 26.00 Cumt 8362.80
200 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars posts and
struts F.FLOOR
13 Providing and laying controlled cement concrete M- 26.00 Cumt 8405.22
200 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars posts and
struts 2nd.FLOOR
14 Providing and laying controlled cement concrete M- 12.00 Cumt 8446.63
200 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars posts and
struts 3rd.FLOOR
15 Providing and laying controlled cement concrete M- 96.50 Cumt 7058.89
250 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Ground & Plinth BEAMS
16 Providing and laying controlled cement concrete 77.00 Cumt 5427.74
M.150 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Plinth Slabs
17 Providing and laying controlled cement concrete 69.50 Cumt 6482.18
M.200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Ground floor Beams,
18 Providing and laying controlled cement concrete 66.00 Cumt 6482.18
M.200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) First floor Beams,
19 Providing and laying controlled cement concrete 66.00 Cumt 6523.59
M.200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Second floor Beams,
20 Providing and laying controlled cement concrete 6.00 Cumt 6565.00
M.200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Third floor Beams,
21 Providing and laying controlled cement concrete M- 8.00 Cumt 6432.69
200 and curing etc. complete including the cost of form
work and reinforcement for reinforced concrete work
in (c) Chhajja for Ground floor
22 Providing and laying controlled cement concrete M- 5.00 Cumt 6432.69
200 and curing etc. complete including the cost of form
work and reinforcement for reinforced concrete work
in (c) Chhajja for F floor
23 Providing and laying controlled cement concrete M- 5.00 Cumt 6475.11
200 and curing etc. complete including the cost of form
work and reinforcement for reinforced concrete work
in (c) Chhajja for S floor
24 Providing and laying controlled cement concrete M- 1.00 Cumt 6516.52
200 and curing etc. complete including the cost of form
work and reinforcement for reinforced concrete work
in (c) Chhajja for T floor
25 Providing and laying controlled cement concrete M- 1.50 Cumt 8972.84
200 and curing etc. complete including the cost of form
work and reinforcement for reinforced concrete work
in (c) Lintal for Ground floor
26 Providing and laying controlled cement concrete M- 3.00 Cumt 8972.84
200 and curing etc. complete including the cost of form
work and reinforcement for reinforced concrete work
in (c) Lintal for F floor
27 Providing and laying controlled cement concrete M- 3.00 Cumt 9015.26
200 and curing etc. complete including the cost of form
work and reinforcement for reinforced concrete work
in (c) Lintal for S floor
28 Providing and laying controlled cement concrete M- 0.50 Cumt 9056.68
200 and curing etc. complete including the cost of form
work and reinforcement for reinforced concrete work
in (c) Lintal for T floor
29 Providing and laying controlled cement concrete 75.00 Cumt 7947.69
M.200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Ground floor Slab
30 Providing and laying controlled cement concrete 62.00 Cumt 7947.69
M.200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) First floor Slab
31 Providing and laying controlled cement concrete 62.00 Cumt 7989.10
M.200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Second floor Slab
32 Providing and laying controlled cement concrete 7.00 Cumt 8031.52
M.200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Third floor Slab
33 Providing and laying controlled cement concrete M- 5.00 Cumt 6166.05
200 and curing etc. complete including the cost of form
work and excluding the cost of reinforcement etc.
complete in RCC Vertical and horizontal wall for GF
34 Providing and laying controlled cement concrete M- 7.00 Cumt 5961.02
250 and curing etc. complete including the cost of form
work and excluding the cost of reinforcement etc.
complete in RCC Vertical and horizontal wall for Up to
35 Providing and laying controlled cement concrete M- 16.50 Cumt 6166.05
200 and curing etc. complete including the cost of form
work and excluding the cost of reinforcement etc.
complete in RCC Vertical and horizontal wall for FF
36 Providing and laying controlled cement concrete M- 5.00 Cumt 6207.46
200 and curing etc. complete including the cost of form
work and excluding the cost of reinforcement etc.
complete in RCC Vertical and horizontal wall for SF
37 Providing and laying controlled cement concrete M- 2.00 Cumt 6248.87
200 and curing etc. complete including the cost of form
work and excluding the cost of reinforcement etc.
complete in RCC Vertical and horizontal wall for TF
38 Providing and laying controlled cement concrete M- 7.00 Cumt 7381.08
200 and curing etc. complete including the cost of form
work and excluding the cost of reinforcement etc.
complete in (E) Stair case up to floor two level for
Ground Floor to first floor
39 Providing and laying controlled cement concrete M- 5.00 Cumt 7381.08
200 and curing etc. complete including the cost of form
work and excluding the cost of reinforcement etc.
complete in (E) Stair case up to floor two level for First
to Second Floor
40 Providing and laying controlled cement concrete M- 5.00 Cumt 7422.49
200 and curing etc. complete including the cost of form
work and excluding the cost of reinforcement etc.
complete in (E) Stair case up to floor two level for
Second to Third Floor
41 Providing and fixing 90 cm high Stainless steel railing 57.00 Rmt 3719.83
made from anticorrocive 316 grade S S pipe of 50 mm
dia (16Gauge) as hand rail with S S 316 grade Baluster
of 38 mm dia (16Gauge) as a vertical support fixed in
RCC slab at 1.2m c/c including three horizontal S S
pipes of 25 mm dia (16Gauge) at eqal distance fixed by
18.75 mm dia (16Gauge) S S pipe with baluster
including accessories as per detailed drawing as
directed etc. complete.
42 Providing and fixing Stainless Steel Hand Railing made 36.00 Rmt 1969.50
from anticorrocive 316 grade S S pipe of 50 mm dia
(16 Gauge) as hand rail with S S 316 grade Baluster of
40 mm dia (16 Gauge) as a vertical support fixed in
RCC member at 1.2m c/c S S pipe with baluster
including accessories as per detailed drawing as
directed etc. complete.
43 Providing IS Mark TMT FE 500D bar reinforcement for 126754.00 Kg 77.77
RCC work including bending & placing in position
complete up to All floor Level
44 Brick work using common burnt clay building bricks 125.00 Cumt 4279.98
having crushing strength not less than 35 Kg./Sq.m. in
foundation and plinth in cement mortar 1:6 (1
cement:6 fine sand) (b) Conventional.
45 Brick work using common burnt clay building bricks 156.00 Cumt 4575.57
having crushing strength not less than 35 Kg./ Sqm. in
cement mortar 1:6 ( 1 cement : 6 Fine sand ) in super
structure above plinth level upto floor two level ( for
G.F ) Conventional
46 Brick work using common burnt clay building bricks 77.00 Cumt 4575.57
having crushing strength not less than 35 Kg/Sq.cm. in
super structure in cement mortar 1:6 (1cement : 6 fine
sand) {First FLoor}
47 Brick work using common burnt clay building bricks 73.00 Cumt 4618.66
having crushing strength not less than 35 Kg/Sq.cm. in
super structure in cement mortar 1:6 (1cement : 6 fine
sand) {SF FLoor}
48 Brick work using common burnt clay building bricks 42.00 Cumt 4661.75
having crushing strength not less than 35 Kg/Sq.cm. in
super structure in cement mortar 1:6 (1cement : 6 fine
sand) {TF FLoor}
49 Half brick masonry in common brunt clay building 142.00 Sqmt 697.93
bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:4 (1-Cement : 4 -coarse
sand ) in foundation and plinth (B) Conventional for G
50 Half brick masonry in common brunt clay building 376.00 Sqmt 697.93
bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:4 (1-Cement : 4 -coarse
sand ) in foundation and plinth (B) Conventional for
51 Half brick masonry in common brunt clay building 377.00 Sqmt 704.33
bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:4 (1-Cement : 4 -coarse
sand ) in foundation and plinth (B) Conventional for
2nd floor.
52 Half brick masonry in common brunt clay building 15.00 Sqmt 710.74
bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:4 (1-Cement : 4 -coarse
sand ) in foundation and plinth (B) Conventional for
3rd floor.
53 Providing 20 mm thick double coat mala cement 641.50 Sqmt 290.72
plaster on interior brick / concrete work for plastering
comprising of base coat of 12 mm thick cement plaster
in cement mortar (1 Cement : 4 coarse sand) in rough
finishing and 8 mm thick top coat of cement mortar 1:2
(1 Cement : 2 Coarse sand) finished with trovel
including scaffolding curing etc. complete.For GF
54 Providing 20mm thick cement plaster in single coat on 1404.00 Sqmt 290.72
single or half brick walls for interior plastering upto
floor two level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand)For FF
55 Providing 20mm thick cement plaster in single coat on 1405.00 Sqmt 319.44
single or half brick walls for interior plastering upto
floor two level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand)For SF
56 Providing 20mm thick cement plaster in single coat on 257.00 Sqmt 348.17
single or half brick walls for interior plastering upto
floor two level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand)For TF
57 Providing 10 mm. Thick Mala plaster in single coat for 821.50 Sqmt 198.57
plastering on ceiling and soffits of stairs and finished
in : (I) Cement mortar 1:4 (1 cement : 4 sand) with
Mala finished of neat cement slurry etc.
complete.Ground Floor
58 Providing 10 mm. Thick Mala plaster in single coat for 534.00 Sqmt 198.57
plastering on ceiling and soffits of stairs and finished
in : (I) Cement mortar 1:4 (1 cement : 4 sand) with
Mala finished of neat cement slurry etc. complete.F
59 Providing 10 mm. Thick Mala plaster in single coat for 533.00 Sqmt 223.72
plastering on ceiling and soffits of stairs and finished
in : (I) Cement mortar 1:4 (1 cement : 4 sand) with
Mala finished of neat cement slurry etc. complete.S
60 Providing 10 mm. Thick Mala plaster in single coat for 43.00 Sqmt 248.86
plastering on ceiling and soffits of stairs and finished
in : (I) Cement mortar 1:4 (1 cement : 4 sand) with
Mala finished of neat cement slurry etc. complete.T
61 Providing and laying synthetic Granular Texture 2757.00 Sqmt 687.41
plaster of average 2-3 mm thickness on a base of
smooth mala plaster having final coat incorporating
fine filaments made up of polymers and aggregating
natural stone powder as tvaried drection,colour and
shade for all floor approved by architect office.
62 Providing 20 mm thick double coat mala cement 2895.00 Sqm 348.17
plaster on Exterior brick / concrete work for
plastering comprising of base coat of 12 mm thick
cement plaster in cement mortar (1Cement : 4 coarse
sand) in roughfinishing and 8 mm thick top coat of
cement mortar 1:2(1Cement : 2 Coarse sand) finished
with trovel including scaffolding curing etc. complete.
63 Providing throating or plaster drip and moulding to 251.00 Rmt 45.33
R.C.C. Chhajja.
64 Providing and finishing POP PUMMING Plaster of 5043.00 Sqmt 217.35
Paris Punning with necessary groove over plastered
wall surface to be finished in line and plumb with
smooth surface ready to receive paint base.(1)12 mm
Average Thickness (2)19mm Average Thickness
including on Punning applying to give an even shade
including thoroughly brushing the surface free from
mortar droppings and other foreign matter and sand
papered smooth. For all floor
65 Wall painting (three coats) with plastic emulsion paint 3610.50 Sqmt 128.91
of approved brand and manufacture on undecorated
wall surface to give an even shade to colour including
throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered
66 Painting (two coats) with plastic emulsion paint of 1931.50 Sqmt 90.64
approved brand and manufacture on undecorated
ceiling surface to give an even shade to colour
including throughly brushing the surface free from
mortar droppings and other foreign matter and sand
papered smooth.
67 Wall Painting (Two coats) with weather proof 100 % 2872.00 Sqmt 122.14
acraylic emulsion (Apex or equivalent type)Water
Repllent paint of approved brand and manufacture and
of required shade on exterior wall surface to give an
even shade over and including primery coat with
Alkaly resistance primer of approved brand after
thoroughly brushing surface to remove all dust and
remains of loose powdered material etc. copm. for all
68 Providing and laying controlled cement concrete M- 11.00 Cumt 8379.97
200 for RCC work and curing complete including the
cost of form work but excluding the cost of reinforced
concrete work in coping on Ground Floor
69 Providing and laying controlled cement concrete M- 3.50 Cumt 8379.97
200 for RCC work and curing complete including the
cost of form work but excluding the cost of reinforced
concrete work in coping on First Floor
70 Providing and laying controlled cement concrete M- 3.00 Cumt 8422.39
200 for RCC work and curing complete including the
cost of form work but excluding the cost of reinforced
concrete work in coping on S Floor
71 Providing and laying controlled cement concrete M- 5.00 Cumt 8463.80
200 for RCC work and curing complete including the
cost of form work but excluding the cost of reinforced
concrete work in coping on T Floor
72 Providing & fixing in position standard extruded 133.00 Sqmt 3796.59
Aluminum Four track (4 shutter) with Fix Glass above
an top Standard Extruded Colour Anodied Alluminium
Section Equivalent to Jindal Series E (30mm) Section
Numbered: Frame -Bottom with Weep Holes -20737,
Frame Top & Side-20738 ,Shutter Top & Bottom
20993, Shutter Inter Lock -20550 ,Shutter Side
(handle) -20549 With 5mm thick Transparent Tinted
Float Glass With EPDM Rubber Gasket, Air Lock Stirip
and Finishing , Joint With Section Sealant, With Power
Coated Standard Alluminium Fitting.with as per
window size including all required materials labours
and equipments as per detailed drwg. as directed.
73 Providing & fixing in position standard extruded 22.00 Sqmt 3843.05
Aluminum Three track (3 shutter) with Fix Glass
above an top Standard Extruded Colour Anodied
Alluminium Section Equivalent to Jindal Series E
(30mm) Section Numbered: Frame -Bottom with Weep
Holes -20737, Frame Top & Side-20738 ,Shutter Top &
Bottom 20993, Shutter Inter Lock -20550 ,Shutter Side
(handle) -20549 With 5mm thick Transparent Tinted
Float Glass With EPDM Rubber Gasket, Air Lock Stirip
and Finishing , Joint With Section Sealant, With Power
Coated Standard Alluminium Fitting.with as per
window size including all required materials labours
and equipments as per detailed drwg. as directed.
74 Providing & Fixing in position standard extruded 8.00 Sqmt 3098.68
approved colour anodised Aluminum Ventilator with
outer frame 65.00 x 25.00 x 1.95 mm (of Jindal Section
No.4605,@ Wt 1.094 kg/Rmt ) with 3mm thick Bajari
figure adgesteble tinted louvers glass fixed to
alluminium strip blade including fixtures , fastenning
labours and equipments as per detailed drawing as
directed. For Ventilators
75 Providing and fixing anodized aluminium door frame 9.00 Sqmt 4648.02
equivalent to Jindal door section No. 19552, weighing
not less than 1.10 kg per metre, with wooden inserts
for durable grips at door hinges and hardware,
complete in all respects; and providing and fixing
mm thick solid core wooden flush double shutters with
Side FIX Glass 5 mm thick conforming to IS:2202 and
ISI approved manufacturer, finished with 1 mm thick
laminates on both sides of each shutter, 6 mm thick
S.S. 316 handles on both sides, S.S. fixtures and locking
arrangement of standard make (Kich or equivalent),
fixed with 150 mm high S.S. hinges and floor spring,
including all fittings, fixtures, samples and shade as
approved by the Architect, complete.
76 Providing and fixing anodized aluminium door frame 96.00 Sqmt 6377.14
equivalent to Jindal door section No. 19552, weighing
not less than 1.10 kg per metre, with wooden inserts
for durable grips at door hinges and hardware,
complete in all respects; and providing and fixing
mm thick solid core wooden flush Single shutters
conforming to IS:2202 and ISI approved manufacturer,
finished with 1 mm thick laminates on both sides of
each shutter, 6 mm thick S.S. 316 handles on both
sides, S.S. fixtures and locking arrangement of
standard make (Kich or equivalent), fixed with
mm high S.S. hinges and floor spring, including all
fittings, fixtures, samples and shade as approved by
the Architect, complete.
77 Providing and fixing anodized aluminium door frame 8.00 Sqmt 5387.34
equivalent to Jindal door section No. 19552, weighing
not less than 1.10 kg per metre, with wooden inserts
for durable grips at door hinges and hardware,
complete in all respects; and providing and fixing
mm thick solid core wooden flush Double shutters
conforming to IS:2202 and ISI approved manufacturer,
finished with 1 mm thick laminates on both sides of
each shutter, 6 mm thick S.S. 316 handles on both
sides, S.S. fixtures and locking arrangement of
standard make (Kich or equivalent), fixed with
mm high S.S. hinges and floor spring, including all
fittings, fixtures, samples and shade as approved by
the Architect, complete.
78 Providing and fixing anodized aluminium door frame 5.00 Sqmt 5177.26
equivalent to Jindal door section No. 19552, weighing
not less than 1.10 kg per metre, with wooden inserts
for durable grips at door hinges and hardware,
complete in all respects; and providing and fixing
mm thick solid core wooden flush double shutters with
Above FIX Glass 5 mm thick conforming to IS:2202
and ISI approved manufacturer, finished with 1 mm
thick laminates on both sides of each shutter, 6 mm
thick S.S. 316 handles on both sides, S.S. fixtures and
locking arrangement of standard make (Kich or
equivalent), fixed with 150 mm high S.S. hinges and
floor spring, including all fittings, fixtures, samples and
shade as approved by the Architect, complete.
79 P & L 60x60 cm' Double Charged vitrified Tiles 10 mm 387.00 Sqmt 1406.93
thick tile flooring over 20mm (Average) thick base of
cement mortar 1:6 (1-cement : 6-coarse sand) or L.M.
1.1.5 laid over and jointed with grey cement slurry
including rubbing and polishing etc
80 Providing and laying Vitrified tiles 8 to 10 mm thick , 70.00 Sqmt 1531.82
36'' x 36'' in flooring treads of steps and landing laid
on a bed of 12mm thick cement mortar 1:3 (1-cement :
3-coarse sand ) finishing with flush pointing in white
81 P & L 60x60 cm' antiskid porcelene Tiles 10 mm thick 45.00 Sqmt 1756.39
tile flooring over 20mm (Average) thick base of
cement mortar 1:6 (1-cement : 6-coarse sand) or L.M.
1.1.5 laid over and jointed with grey cement slurry
including rubbing and polishing etc
82 Providing and laying antiskid Ceramic tiles 6mm thick 75.50 Sqmt 1017.30
in flooring treads of steps and landing laid on a bed of
12mm thick cement mortar 1:3 (1 cement : 3-coarse
sand ) finishing with flush pointing in white cement.
83 Providing and laying Ceramic tiles 6mm thick in 498.50 Sqmt 1091.96
skrting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with
white cement slurry
84 P & L 60x60 cm' GVT Tiles 10 mm thick tile flooring 315.00 Sqmt 1431.17
over 20mm (Average) thick base of cement mortar 1:6
(1-cement : 6-coarse sand) or L.M. 1.1.5 laid over and
jointed with grey cement slurry including rubbing and
polishing etc
85 Providing and fixing readymade full body vitrified tiles 118.00 Sqmt 1913.95
colour in staircase area, including 152 × 30 cm treads
nosing and self-embossed anti-skid strips, 150 × 15 cm
risers, 60 × 60 cm full body vitrified tiles in
landings/rest areas, and 10 cm high skirting of the
same material and colour, laid over prepared surface
using approved tile adhesive, maintaining proper line,
level and alignment, including cutting, edge finishing,
joint filling with matching grout, cleaning and all
incidental works, complete in all respects as directed
by the Engineer-in-Charge.
86 Providing and laying water proofing treatment with 453.00 Sqmt 779.70
broken chine mosaic flooring for terrace using 12 mm
to 20 mm broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be
tempered to bring mortar creme out upto surface
using white cement including rounding off junctions
and extending them upto 15 cm along the wall,
clearing with water and oxalic acid etc. as directed.
87 Providing and laying cement concrete flooring 1:2:4 (1- 453.00 Sqmt 348.85
cement : 2-coarse sand : 4-graded stone aggregate
20mm nominal size) laid in one layer and finished
with a floating coat of neat cement. (B) 50mm thick.
88 Providing and laying Heavy Duty 10 to 12 mm thick 359.00 Sqmt 1522.47
Parking Vitrified tiles flooring of PAVIT or equivalent
make in required pattern, shape & design, laid on
mm. thick cement mortar 1:6 ( 1 cement : 6 coarse
sand) make with spacer joint of approved quality
cement grout of the make Bal Gold Star, cleaning,
washing & etc. complete. For Parking
89 Providing and fixing Granite 18 to 20 mm with full 214.50 Sqmt 1995.76
round edge and polished of approved quality in clading
on sill and around the doors/ windows/ ventilation
with 12 mm thick cement mortor CM (1:4) and fixing
with cement slurry & adhesive including moulding of
exposed edges as directed by engineering in charge
etc. complete.
90 Providinfg and fixing Safty grills of required pattern for 2904.00 Kg 125.85
windows/ Door using necessary M.S angle/ M.S pipe,
M.S flats and other structural steel at required spacing
including cutting, welding and fabriction etc. including
one coat of primer of approved quality and two coats
of oil painting as per detail drawing etc complete.
91 Providing Erecting and fixing Triple Layer Plastic Pure 10000.00 Litre 12.63
Antibacterial Water White Tank of required capacity
each with all necessary fittings and connection etc.
complete on terrace.
92 Providing laying and jointing in true line and level 60.00 Rmt 195.67
50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings make PRINCE / SUPREME / ASTRAL
/ FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
93 Providing laying and jointing in true line and level 190.00 Rmt 148.12
40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings make PRINCE / SUPREME / ASTRAL
/ FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
94 Providing laying and jointing in true line and level 330.00 Rmt 91.84
25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings make PRINCE / SUPREME / ASTRAL
/ FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
95 Providing laying and jointing in true line and level 240.00 Rmt 72.65
15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings make PRINCE / SUPREME / ASTRAL
/ FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
96 Providing, laying and jointing in true line and level 160 50.00 Rmt 834.38
diametre U.P.V.C (Type B) conforming to IS 13592-
1992 with one end plain and other end socketed with
rubber ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe
shall be jointed with each other with rubber lubricant,
pipe shall be fixed on wall using of PVC clamp of the
size 160 mm diametre x 210 mm length x 196 mm
heigh at every 2000 mm center to center or shall be
concealed in walls as directed including necessary
fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
97 Providing laying (to level or slopes) and jointing 372.00 Rmt 678.03
reinforced concrete Light duty non-pressure pipes I.S.
class NP2 of the following internal diameter with
collars and butt ends prepared for collar joints
including testing of joints complete.(D)
98 Providing, laying and jointing in true line and level 110 100.00 Rmt 899.49
diametre U.P.V.C (Type B) conforming to IS 13592-
1992 with one end plain and other end socketed with
rubber ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe
shall be jointed with each other with rubber lubricant,
pipe shall be fixed on wall using of PVC clamp of the
size 110 mm diametre x 149 mm length x 145 mm
heigh at every 2000 mm center to center or shall be
concealed in walls as directed including necessary
fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
99 Providing, laying and jointing in true line and level 75 30.00 Rmt 779.72
mm dia. UPVC SWRType B pipe conforming to IS
13592-1992 with one end plain and other end
socketed with rubbering and fitting conforming to ISI
14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of
PVC clamp at every 2000 mm c/c or shall be conceled
in walss as directed including necessary fittings such
as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement
including cost of all materials.
100 Providing and fixing in PVC SWR cowel went 75mm 2.00 No 15.66
dia to pipes.(B) 75mm dia.
101 Providing and fixing in PVC SWR cowel went 110mm 10.00 No 28.79
dia to pipes.(B) 110mm dia.
102 Providing and fixing MS Z clamp on Wall or celling for 415.00 No 116.15
Pipe Fitting including all type necessary fittings and
accessory etc. completed as per directed engineer in
103 Providing and fixing PVC SWR Nahni trap IS 14735 for 30.00 No 613.92
drain - 100 mm diameter with jali of the following
nominal diameter of self cleansing design with C.I
scread down or hinged grating including the cost of
cutting and making good the walls.
104 Providing and fixing Tankless Wall Hung WC with 10.00 No 33218.90
Sensor Flush, model ONS-WHT-10961BIUFSMTL or
Jaquar standard company, of size 380 x 625 x 385 mm,
complete with UF soft-close slim seat cover, hinges,
concealed flush system, suitable wall frame support
system ( Jaquar ), exposed part kit of concealed stop
cock & flush cock (model KUP-35083KPM or
equivalent), health faucet (model ALD-577 or
equivalent) with 8 mm dia, 1 meter long flexible tube,
wall hook and N.R.V. (backflow preventer), including
all required fittings, accessories, connection materials,
testing and installation complete as per
manufacturer’s specifications and as directed by the
Engineer-in-Charge.
105 Providing and fixing S3030102 Orissa Pan Cello 500 x 5.00 No 3764.25
400 mm CERA or equivalent premium quality awith
'P' or 'S' trap jointed with C.I. pipes in C.M. 1:1
complete for all Floor with all accessories etc.
complete. The BRAND should be as per given
specification or Equivalent or as per directed engineer
106 Providing and fixing stainless steel grab 22 cm x 60 cm 3.00 No 1492.78
for handicapped toilet
107 Providing and Fixing a set of wall mounted 38 mm dia 3.00 No 5090.40
U shaped horizontal stainless steel collapsible grab bar
, 38mm vertical stainless steel fixed grab rail of grade
SS 304 from round pipe supported and 75 mm dia
mm thick SS 304 base flange on wall including anchor
fasteners, nuts, accessories as per detailed drawing
etc. complete as directed by Architect or Engineer in
108 Providing and fixing Bib Cock (Straight Line Model) 25.00 No 2643.17
with Wall Flange (Range: Solo, Code: SOL-CHR-6047)
made of high quality brass with chromium plated
finish, complete with wall flange, nuts, washers and all
necessary fittings, including connection to water
supply line, complete as directed by the Engineer-in-
109 Providing and fixing Full Pedestal Wash basin for CNS- 5.00 No 6806.39
WHT-801 Jaquar brand or equivalent CNS-WHT-801
wall mounted Size: 560x415x200 size snow white with
C.I. or M.S. bracket including cutting holes and making
good the same including fixing Auxiliaries - Waste
coupling full thread, C.P. brass extension nipple 62 mm
long, S.S. flange water super connection pipe 60cm.
long and full thread waste coupling, etc.
complete.The BRAND should be as per given
specification or Equivalent or as per directed engineer
110 Providing and fixing 5 mm thick mirror of approved 12.00 No 993.54
quality and make size 600 x 450 mm with moulding
edge by using 4.0 mm thick hard board and fixing on
wall with C. P.brass studs etc. complete. For all floor
The BRAND should be as per given specification or
Equivalent or as per directed engineer incharge
111 Providing and fixing ball cock of approved. quality as 2.00 No 189.84
directed.(A) Copper Metal (ii) 50mm dia.
112 Providing and fixing Chrome plated Bib Cock with Wall 15.00 No 3049.19
Flange (Make: Opal Prime, Range: Opal Prime, Code:
OPP-CHR-15037PM) of approved quality, made of high
quality brass with chromium plated finish, including
wall flange, complete with all necessary fittings, joints,
nuts, washers and connection to the water supply line,
complete as directed by the Engineer-in-charge.
113 Providing and fixing Single Towel Rail 450 mm long 18.00 No 3165.34
(Range: Continental, Code: ACN-ABR-1111BSM) made
of high quality brass with approved finish, fixed to wall
with necessary screws, rawl plugs and fittings,
complete in all respect as directed by the Engineer-in-
114 Providing and fixing Pillar cock JAQUAR brand 18.00 No 1835.17
FLORENTINE CAT. NO. - 5011N with 15 mm dia with
C.P. brass extension nipple 62 mm long etc.
complete.The BRAND should be as per given
specification or Equivalent or as per directed engineer
115 Providing and fixing in position 300 mm high, 150 mm 100.00 No 707.00
wide English letters made from 1.0 mm thick stainless
steel sheet as directed by Engineer in charge with all
necessary tools & plants etc. complete.
116 Providing and laying (two level or slopes) and jointing 70.00 Rmt 531.19
with stiff mixture of Cement Mortar in proportion 1:1,
Salt glazed stone ware pipes of pipes 150mm laying
lime concrete 1:2:4 (1-Lime putty :2-Fine samd : 4-
Graded brick aggregates 40mm nominal size) bedding
for stoneware pipes of following internal diameters
with necessary formwork and curing complete.
117 Providing and fixing S.W. gully trap with C.I. grating 10.00 No 1246.92
brick masonry chamber and water tight C.I. cover with
frame of 300mm x 300mm size (inside) with standard
weight (i) Square mouth traps (B) 150mm x 100mm
size P or R type
118 Constructing brick masonry chamber for underground 12.00 No 3454.80
C.I. Inspection chamber and bends with briocks having
croshing strength not less than 35Kg. Cm2 in C.M. 1:5
precast RCC cover 455mm x 610mm intenal
dimensions with frame (R.C.C. top slabe with 1:2:4 mix
(1-cement :2- coarse sand :4-graded stone aggregate
20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth
with a floating coat of neat cement on walls and bed
concrete etc. complete (i) Inside dimensions 455mmx
610mm and 450mm deep for single pipe line.
119 Constructing brick masonry chamber for underground 11.00 No 4258.97
C.I. Inspection C.I. Inspection chamber and bends with
briocks having croshing strength not less than 35Kg.
Cm2 in C.M. 1:5 precast RCC cover 500mmx 700mm
intenal dimensions with frame (R.C.C. top slabe with
1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10
inside plaster 15mm thick with cement mortar 1:3
finished smooth with a floating coat of neat cement on
walls and bed concrete etc. complete (i) Inside
dimensions 500mmx 700mm and 450mm deep for
single pipe line.
120 Extra over items for every additional depth of 0.1M. of 6.00 Each 242.39
part thereof beyond 450mm depth for Brick masonry
chamber.(i) for 455mm x 610mm size.
121 Extra over items for every additional depth of 0.1M. of 5.00 Each 264.86
part thereof beyond 450mm depth for Brick masonry
chamber.(i) for 500mm x 700mm size.
122 Providing and fixing MS Ladder of required pattern 250.00 Kg 126.76
with MS flats(30x3mm) or round or square bars
(12mm) at required spacing & with round headed
bolts and nuts or screws or welding including primer
coat of approved quality and two coats of oil paintas as
directed by engineer in charge
123 Providing and fixing in position 150 mm high, English 100.00 No 404.00
letters made from 1.0 mm thick stainless steel sheet as
directed by Engineer in charge with all necessary tools
& plants etc. complete.
124 Constructing drinking/Handwash Platform of 18 mm 7.00 Sqmt 8228.47
thick Polished Black Granite having 0.45m width and
0.60m height including 0.60m support at every 0.7m
c/c with cementing Materials / adhsives including
makeing necessary grooves in walls including Wash
Basin Snow White size 400x400x135mm including
Polyamide braided connection pipe 12mm dia, 450mm
length Wast coupling with ceramic Pop-up push type
(Full thread) 32mm Dia Cat. No. F8050351 with all
fitting inlet and outlet connection and all required
fitting accessories etc. with all labour material of
approved quality incl. full moulded round front edge
granite strip of one side polished and jointed with
grey cement slurry including rubbing and polishing
etc. complete for all floors
125 Providing and fixing Urinal of Jaquar URS-WHT- 9.00 Nos 6864.47
13261H Urinal With Spreader Hole And Fixing
Accessories, Size: 355x340x535 mm including
connection with trap , Auxiliaries Waste coupling full
thread and with integral longitudinal flush pipe with
Quarter turn flush valve Brass etc completed The
BRAND should be as per given specification or
Equivalent or as per directed engineer incharge
126 Providing and fixing polished 18 mm thick black 5.00 Sqmt 2897.69
granite with full round edge and double side polished
of approved quality in between urinal and fixing with
cement slurry & adhesive including moulding of both
exposed edges as directed by engineering in charge
etc. complete.
127 Charges for making holes from 50mm to 160 mm dia 40.00 No 858.50
in RCC wall, slabs or any other RCC members or Brick
work by diamond core cutting machine of HILTI or
equivalent including disposing the debris. For all floors
128 Providing and fixing coloured self adhesive PU-Tactile 54.00 Sqmt 4586.41
tile, ground surface indicators of Polyurethane) of size
300mm x 300mm for guiding/warning to the visually
visitors in the centre/side of the pedestrian/approach
pathway as per specification and guidelines complete
in all respect to the entire satisfaction of in charge.
129 Providing and fixing 150 mm wide, approved quality 544.00 Sqmt 368.65
chicken wire mesh at junction of brick work and RCC
work or two dissimilar surfaces, at all heights fixed by
nails, rowal plugs or tag by cement mortar 1:3 before
applying the plaster, including curing, scaffolding all
complete as directed.
130 Providing and fixing acrylic multilingual Braille (raised 36.00 Nos 1696.80
dots) DIRECTIONAL SIGNBOARDS of size 225 x
150mm designed as per accessibility standards and
having 3.5mm thick acrylic base plate with Upper Case
San Serif words made of white acrylic non glare cut out
letters of height 15mm raised not less than 0.8mm
above base plate and the equivalent word written in
Hindi with Devanagari non glare acrylic letters of
height 15mm raised not less than 0.8mm above base
plate and having a non-glare acrylic cut arrow pointing
in the required direction. Each signboard to be fixed as
per manufacturers specifications on the wall at the
approved location and at a height of 1200mm from FFL
complete as per design / specifications and guidelines
as per the entire satisfaction of the Engineer-in-charge
131 Providing And filling with good quality sinder(steam 70.00 cumt 555.50
coal) as directed by engineer in charge in sunks in
layers of 15 cm thick,including watering,placing
,ramming well etc as directed, for all floor.
132 Providing and laying water proofing treatment by 93.00 sqmt 986.77
conventional method including cleaning the slab
surface by wire brush as directed including provding
first layer of C.M. 1:4 of 40 mm thickness mixed with
water proofing compound at rate prescribed by
manufacturer, including putting of brick bats of
average thickness 40 mm Well immerssed in water
laid uniformly on first layer of mortar including
applying cement slurry @ rate of 0.08 bag/sqm. on
fixed layer of brick bats including maintaining
necessary slope, in second layer 40 mm thick C.M 1:4
mixed with water proofing compound as directed,
including finishing smooth with cement slurry as
directed complete.
133 Providing & Fixing tactile layout plan of size 900mm x 1.00 Nos 33027.00
600mm as approved design, made of 3.0mm thick
acrylic non glare base plate and non glare cut out
symbols with Braille on which individual facility
points, like inquiry, reception, restrooms, medical
room / first aid, cafeteria or breakout area, lounge,
meeting room, conference room etc. present the
respective floors with pictograph wherever needed all
in tactile raised by minimum of 1.0mm to 2mm in
various colours to make it legible for seniors, partial
vision impaired etc. All the facility names should be in
Braille, along with English or Hindi. The entire block of
tactile signs should be mounted on wall for easy
reading. The map to be installed at specified locations
and installed at a height of 800mm from ground level
complete in all respect as per Harmonized guideline &
satisfaction of Engineer in charges.
134 Providing and fixing of acrylic, non-glare, tactile audio 1.00 Nos 43480.50
pictorial building layout as per the approved size,
design and make, having 3mm thick acrylic non glare
base plate of the approved colour and non-glare acrylic
cut out symbols raised 3mm above base plate and
Grade 2/ Grade 1 Braille to be integral with the sign
face and be raised 0.5mm above base plate. The map to
be installed at the specified location as per
accessibility standards, shall be oriented to the
position of the viewer and to be installed at a height of
800 mm from the finished ground/ floor level and
using the necessary hardware specified by the
manufacturer and to be installed up to the height of
800 mm from the finished ground/ floor level and
using the necessary hardware specified by the
manufacturer and to be installed complete as per
design/specifications and guidelines as per the entire
satisfaction of the the Engineer-in-charge
135 Providing & fixing Braile indicator of size 170 mm x 90.00 Rmt 820.12
35mm for handrails of the approved design and make
have braile dots raised 0.5 mm above base plate to be
installed at specific locations as per direction of
engineer in charge
136 Providing and fixing of conspectus tape 50mm width 90.00 Rmt 91.91
on of treads in staircase including cutting pasting etc.
As per harmonised guidelines complete in all respect
to the entire satisfaction of engineer in charge.
137 Providing and fixing POP false ceiling including all 367.00 sqmt 972.63
necessary framework, supports, and accessories. The
system consists of main channels, intermediate
channels, and perimeter channels fabricated from
suitable galvanized sections, with hangers (rods,
cleats, and fasteners) and connecting clips/screws for
proper alignment and stability. A wire gauge mesh of
0.71 mm thickness is fixed as required. The false
ceiling is finished with 9 mm thick POP (Plaster of
Paris) powder applied over the framework to achieve a
smooth and level surface. The work includes careful
measurement and execution as per site conditions,
including proper fixing of all channels, accessories, and
POP finishing, complete with labour charges, ensuring
a durable, as approved by the engineer-in-charge.
138 Providing & Fixing 114mm wide G.I. Sheets lovers 17.00 sqmt 5091.41
having weight not less than 490 Gm/m roll formed to
create 84mm wide louver snap fixed on special shaped
GI channel. Fix louvers & channels shall finished with
powder coating of 55 micron (1) 0.55mm thick
139 20mm thick sand faced cement plaster on walls upto 55.00 Sqmt 365.95
height 10 metres above ground level consisting of 12m
thick backing coat of C.M. 1:3 (1-cement : 3-sand) and
8mm thick finishing coat of C.M. 1:1 (1-cement : 1-
sand) etc. complete.
140 Providing and fixing C.I. Manhole cover 0.60 M. x 1.00 Nos 958.17
0.45M. size having weight not less than 35Kg.
141 Providing & erecting open well horizontal mono block 1.00 Nos 16483.20
pump set with cast iron body, complete for three phase
submersible motor having [H]For 5 H.P,3 phase open
well horizontal mono block pump set suitable for
LPM to 285 LPM @ 20 to 24 MTR head suitable for
65/80 mm dia delivery pipe
142 Supplying & erecting approvedmake 3 phase motor 1.00 Nos 19695.00
control cubicalpanel (Star-Delta) made from 16G.CRCA
sheet duty painted with epoxy powder painted inside
and outside with hinged doors and locking
arrangement, consisting suitable size of ON-OFF
isolator (AC- 3/23duty) main fuses,single phasing
preventer cum water level, Guard(Compe unit), Toggle
switch to by pass Single phase preventercum
WLG,indicating lamps forR-Y-Bphases, over load
relay.Automatic water level controller, Ammeter
incoming wires duty socket Crimped,Panel to be
erected on angle iron frame grouted on wall as
overload relay,thermal/Electronics star delta cutoff
timer,start-stop push buttons.The isolator overload
relay &cntractors ofL&T,Siemens or Cuttler Hamer
make only.Panel to be erected on angle iron frame
ground on wall (e)S/D upto 2.5 H.P.
143 Applying two coats of Birla or Asian acrylic lapy 132.00 Sqmt 40.59
(putty) & two coats of primer of approved brand and
manufacture on new wall surface to give an even shade
including thoroughly brushing the surface free from
mortar dropping and other foreign matter and sand
papered smooth.
144 Providing and fixing rolling shutters of approved make 5.00 Sqmt 3554.40
made of 80 mm wide M.S laths inter-locked together
through heir entire length and jointed together at the
ends by end locks mounted on specially designed pipe
shaft with bracket plates,guide channels and
arrangement for inside and outside locking with push-
pull operation including the cost of hood cover and
sprig etc.complete(A) Shutters having width below
145 Drilling of min. 250 mm dia. bore hole in all strata 90.00 Rmt 1240.28
including dualover burden strata by combination
DR/DTH rig including lowering 200 mm dia MS ERW
pipes in bore hole and testing etc.all work as per
directed engineer incharge.
146 Supplying slotted PVC pipes of approved quality at site 90.00 Rmt 555.50
of work confirming to IS. 1239/1974 180mm dia.
147 Bore plug having 100 mm height made from M.S. plate 1.00 Nos 1161.62
with 3 holes at equal distance on circumference for nut-
bolts type, locking arrangement with nuts-bolts & lock
nuts of std. Make complete. For 250mm dia
148 Providing PVC insulated flat submersible cable as per 50.00 rmt 180.79
detailed technical specifications of R/C of GWSSB
conforming to IS 694, IEC 60227 / 60228.d)1 R x 3 C x
149 Suppling and installing 3 Phase Borewell 3.0 HP 1.00 Set 37130.63
Submersible Pump Sets Electric motor driven
conforming to I.S. 8034 and motor conforms to IS-
9283 working at 3 phase 400/440 volt 50 C/S A.C.
supply & 2900 R.P.M. cat
150 Providing and fixing check or non return pully wheel 1.00 Nos 1111.00
valve of 50 mm diameter.
151 Manufacture, supply and delivery of following ISI 45.00 rmt 152.51
marked HDPE pipes (IS:4984/1985 with latest
amendment) having material Grade PE-80 in
approximate 100 meter coil length or as per GWSSB
requirement with SS 316 nipple at both ends having
11 TPI threads as per specifications, press fitted and
bolted having nominal diameter as under as per
detailed technical specifications.
152 Constructing brick masonry chamber for underground 4.00 No. 7180.44
C.I. Inspection chamber and bends with briocks having
croshing strength not less than 35Kg. Cm2 in C.M. 1:5
C.I. cover with frame (Light duty) 455mm x 610mm
intenal dimensions, total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of
frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-
cement :2- coarse sand :4-graded stone aggregate
20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth
with a floating coat of neat cement on walls and bed
concrete etc. complete.(iii) Inside dimensions 600mm
x 850 mm and 450mm deep for pipe lines with three
or more inlets.
153 Providing and fixing and floor 10.0 Kg. F/Cm2 working 110.00 Rmt 339.05
pressure poluthene pipes of the following outside Dia.
Low densidy, complete with special falnge
compression type fittings, wall clipsetc. including
making good the wall ceiling and floor.(G)110 mm
154 Providing and fixing and floor 10.0 Kg. F/Cm2 working 40.00 Rmt 696.90
pressure poluthene pipes of the following outside Dia.
Low densidy, complete with special falnge
compression type fittings, wall clipsetc. including
making good the wall ceiling and floor.(G)180 mm
155 Providing junction for rain water juncton chamber of 2.00 Nos. 9133.43
size 0.60x0.60x0.75m with excavation of size
1.96x1.96 m & 0.15m thick c.c.1:2:4 bed concrete
including brick masonary wall in CM 1:6 of 0.75m
height & 0.23m thick with 15mm thick cement plaster
inside & outside & 1.06x1.06 RCC (1:2:4) slab of
thickness 0.15m with CRS steel and 0.60mx0.45m cast
iron manhole cover with frame weight not less than
kg as per directed by Engineer-in-charge
156 Providing and installation Recharge pit of “RAIWOHA” 1.00 Nos. 109645.60
Make 3 layer RCC Precast Injection well system of size
1.5 meter Dia. X 3.4 Meter Height rein forced concrete
precast three layer module with 6” dia x 12” dia. V wire
screen of 0.75mm x 1.0 mm Slot size in SS 304 material
and 1.0 meter height with MS Top cover and required
Air vent including all necessary excavation and
transportation at site including required filter media
for the recharge system as per site requirement.
157 Box cutting the road surface to proper slope and 375.00 Cum. 112.02
camber for making a base for road work including
removing the excavated stuff and depositing on the
road side slope as directed upto upto All lift and lead..
158 Construction of granular sub-base 150 mm thick by 159.00 Cum. 1276.64
providing coarse graded machine crushed B.T.
material satisfying MOST specification of grading I
(B.T. stone aggregate 53 mm to 26.5 mm 35 %, 26.5 to
4.75 mm - 45 % and 2.36 mm below - 20 % )including
spreading in uniform layer with motor grader on
prepared surface, mixing by mix in place method with
rotavator at OMC and compacting with vibratory roller
to achieve the desired density etc. complete.
159 Providing and laying wet mix macadam base course 154.00 Cum. 1313.00
250 mm thick in two layers using machine crushed
B.T. chips as per required gradation mixing with
required optimum quantity of water, conveying the
mix to site of work, spreading in to grade and camber
with mechanical paver and consolidation each layer
with vibratory roller including cost of material labour
plant and equipment etc. complete.
160 Compaction and finishing of cement concrete road by 732.00 Sqm 65.65
trimix process providing extra Labour charges for the
trimix vacume dewatering service process on cement
concrete road sutface by using vacuum dewatering
pump floater surface vibrator including making groves
and rough finish to surface including leveling etc
161 Providing and fixing pre-cast Rubber Dye inter locking 274.00 Sqm 707.55
concrete block 60mm thick with grade of concrete
M300 pnumatic compressed by mechanically pressed
and as per approved design including 75mm Sand
layer for levelling and filling the joint with sand in
proper line and level etc complete.
162 Providing and Laying homoginious Grey cement based 274.00 Rmt 374.92
concrete kerbing of size 30 cm x 30 cm x 10 cm size as
per detailed drawing having grade of concrete M25
grade, including necessary excavation, BBCC 1:5:10
cm as per ddetailed drawing fixing in line and level,
filling joints in CM 1:3 with smooth finished, white
washing three coats etc. complete as directed by
Engineer in charge.
163 Demolition of Brick work and stone masonry including 113.00 Cumt 591.68
stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(ii) In
Cement Mortar.
164 Demolition including stacking of serviceable materilas 26.00 Cumt 1137.19
and disposal of unserviceable materials with all lead
and lift. (i) R.C.C. work
165 Steel work, welded in built up sections framed work 750.00 kg 91.08
including cutting, hoisting, fixing in position and
applying a priming coat of read lead paint & two coat
oil paint. (A)In beams and joists, channels angles Tees,
flats, with connecting plates or angle cleats as in main
and cross beams. Hip and jack rafters, purlins
conneted to common rafters and the like.(Gate)
166 Providing and fixing concertina coil fencing with 199.00 Rmt 516.11
punched tape concertina coil 600 mm dia 10 mt
openable length having 50 no rounds per 6 mt length,
upto 3mt height of wall with existing angle iron
(50mm x50mm x5mm )requird shaped As per
Directed Engeenier in charge. placed 2.4mt or 3.00mt
apart and with 4 horizontal R.B.T. reinforced barbed
wire(3 mm) , stud tied with G.I. staples and G.I. clips to
retain horizontal, including necessary bolts or
G.I.barbed wire tied to angle iron, all complete as per
direction of Engineer-in-charge, with reinforced
barbed tape (R.B.T.)/Spring core (2.5 mm thick) and
weight 43.478 gm/meter at compound wall for ESR
M4/ intakewell.
167 Constructing providing and fabricating cattle guard 5.00 Sqmt 5194.43
using channel section frame of size ISMC series
mm x 50 mm (Weight 9.20 kg/Rmt) and ISMC section
100 mm x 75mm (weight 11.50 kg/Rmt) intermediate
support for welding G.I.pipe at 12 Cm C/C of size
mm in a frame made of Channel section size 100 mm x
50 mm all round including fixing the unit on prepared
chamber of masonary wall using MS hold fast embeded
in masonary wall top as directed by Engineer in charge
and as per drawing and necessary required
arrangement etc complete.
168 Supplying of well rotted FYM manure with all lead and 16.00 Cum. 378.75
Lift including spreading mixing dressing and rolling
with hand roller etc. complete.
169 Scarifying the surface of Soil including spreading of 629.00 Sqm 26.26
DAP fertilizer mixing with Soil properly levelling gand
dressing of the plot
170 Supplying and planting semi carpet lawn in Gunny Bag 629.00 Sqm 121.42
and Cost of labour And including maintanatce .As per
Eng-in charge
171 Supplying And Planting box hedge Shurbs of Average 15.00 No. 103.01
hight 1ft-2 ft By providing and mixing FYM 2@ rate of
0.06cmt/pit with soil pesticide & Insectiside Plant
should be deisease Free and fungs free in 6inchx 8inch
polythene bag plastric bag or pots should be remove
carefully and soilt around the roots should not be
droped or distrub much bill shall be placed after
completions of maintanace period but not before
stablizing the shurbs.mortality rate to beinclusive .as
directed and approved by ECI. the ground coverage
should be dense and uniform throghout the planting
172 Supplying well Grown Shurbs Plants of Average hight 20.00 No. 103.01
3ft-4 ft and planting in 300x300x300mm size Pits By
Mixing Of FYM & Existing soil in ration 1:3 with soil
,Pesticide & insecticide .plants should be disease free
and fungus free in 8ftx10ft polythene bag plastric bag
or pots should be remove carefully and soilt around
the roots should not be droped or distrub much bill
shall be placed after completions of maintanace period
but not before stablizing the shurbs.mortality rate to
beinclusive .as directed and approved by ECI. the
ground coverage should be dense and uniform
throghout the planting area
173 Supplying well Grown Canna Bulb Plants of Average 15.00 No. 86.75
hight 1ft-2 ft and Providing in 2 row at 300mm/cc in
300x300x300mm size pits by Providing and Mixing Of
FYM @ 0.06cmt/pit with soil pesticide and insecticide
.plants should be disease free and fungus free in
8ftx10ft polythene bag plastric bag or pots should be
remove carefully and soilt around the roots should not
be droped or distrub much bill shall be placed after
completions of maintanace period but not before
stablizing the shurbs.mortality rate to beinclusive .as
directed and approved by ECI. the ground coverage
should be dense and uniform throghout the planting
174 Providing and planting of Khengar tree plants healthy 15.00 No. 961.70
and well-grown, of height not less than 3 ft, in polybags
or earthen pots, including excavation of pit of required
size, arrangement and placing of rubble at bottom for
proper drainage, refilling the pit with good quality
garden soil mixed with FYM, watering, application of
organic and chemical fertilizers, pesticides, all
complete including cost of labour, materials, and as per
direction of Engineer-in-Charge."
175 Bowing and developing flowering plants grown in 8.00 No. 10.10
nusery having approximate height 4 to 5 ft or Height
ad per Landscaps Plan with natural growith and nature
colour planted in alump of soil packed in polithyline
bag or Earthern pot. Including organic & chemical
fertilizer pesticides, fungicides hormones &
maintaining the plants uo to three months as deserted
green mahindi
176 Bowing and developing flowering plants grown in 5.00 No. 15.15
nusery having approximate height 4 to 5 ft or Height
ad per Landscaps Plan with natural growith and nature
colour planted in alump of soil packed in polithyline
bag or Earthern pot. Including organic & chemical
fertilizer pesticides, fungicides hormones &
maintaining the plants uo to three months as deserted
New block ficus.
177 Labour charges for planting various plantsafter proper 78.00 No. 40.40
anti termite treatment in pits including placing
property and filling the pit with requred prepared mix
soil and wetering and dispporting etc complete.
178 Maintance of the garder for 360 days after Complition 1.00 Job. 10100.00
of 3 month stipulated period is completed for
plantation o lawn and plants including applying second
round of proper antitermite tretment.
179 Providing and fixing brass screw doen stop cock (A) 15 1.00 Nos 287.85
180 Rubber Hose pipe 15 mm dia of approved brand and 120.00 Rmt 80.80
181 Providnig and fixing G I Nipple as directed. 1.00 No. 20.20
182 Earthwork in cuting in all sorts of soil and soft murrum 0.80 Cumt 129.28
including conveying and spreading the stuff,
embankment as and where directed within 200meters
from the end of the cutting with all required lead and
lift.(C) Above 400 Meters
upto 500 Meters.
183 Earthwork for embankment including breaking clods, 1067.80 Cumt 173.31
dressing with all lead and lift (excluding watering and
consolidation)(E) From Borrow area within all lead
184 Rolling of earthwork in layers with power roller 1068.00 Cumt 23.18
including filling in depressions which occur during the
process and Watering of earth work as directed.
185 Supply, installation, testing & commissioning of ISI 1.00 No 98432.21
approved electrical motor driven jockey pump set
having 10.8 m3/hr. @ 70m head. The pump unit shall
be a horizontally direct mounted motor. Unit shall
comprise the following minimum requirements: a)
Pump, b) Electric motor IE2, c) Foundation bolts, d)
Mating flanges with gasket and fasteners, e) Discharge
gauges, etc. complete in all respect, with labour.
186 Supply, installation, testing & commissioning of 1.00 No 25677.97
Priming tank, HDPE type, 1000 litres, with necessary
piping 100 mm size, G.I pipe for priming the pumps,
pipe of with butterfly valves for isolation, Water
Filling to priming tank by piping min. 50 mm size, with
all complete.
187 Supply, installation, testing & commissioning of 1.00 No 55635.60
Manifold (surge vessel) for fire hydrant system, min.
300 mm diameter, made from M.S plate, hydro tested
to 15 kg./cm2. with ball valves, header with couplings
for fitting pressure switches, pressure gauges etc.with
necessary isolation valves with all complete.
188 Supply, fabrication & erection of aboveground G.I. 'C'- 30.00 Mtr 398.01
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system
pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 25 mm dia.
189 Supply, fabrication & erection of aboveground G.I. 'C'- 30.00 Mtr 641.95
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system
pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 50 mm dia.
190 Supply, fabrication & erection of aboveground G.I. 'C'- 20.00 Mtr 1176.90
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system
pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 80 mm dia.
191 Supply, fabrication & erection of aboveground G.I. 'C'- 100.00 Mtr 1690.47
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system
pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 100 mm dia.
192 Supply, fabrication & erection of aboveground G.I. 'C'- 6.00 Mtr 2525.00
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system
pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 150 mm dia.
193 Supply, fabrication & erection of aboveground G.I. 'C'- 6.00 Mtr 3423.73
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.
Hydrostatic testing for 2 hour's at 150% of the system
pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 200 mm dia.
194 Supply, installtion, testing & commissioing of 10.00 Mtr 2020.00
Underground GI (ERW) piping conforming to IS:1239,
part-I, Heavy class ('C' class) up to 150 mm dia. and
IS:3589 Heavy class ('C' class), for 200 mm dia. &
above, min. 6.35mm thickness including Heavy class
fittings, anti-corrosive tape of size 150 mm wide x
mm thick, wrapping & coating with 13KV holiday
testing . Rates shall include sand bedding of 75mm dia
all around, backfilling of the excavated including
installation of heavy pipe fitting's, flanges, etc. 10 % of
all the welded joints shall be done radiographically
tested and 50% of the joints radiographed shall be the
"Field Joints". Hydrostatic testing for 2 hours at 150%
of the system pressure, hook-up etc., complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. (Road Crossing) 100 mm dia.
195 Design, Supply and installation of Safety Signage made 1500.00 Sq. 9.41
of Zinc Sulphilde based glow in dark , Rigid sheet with inch
High Luminous property enclosed in a transperent
weather proof UV stabilized plastic pasted on 3 mm
thick clear acrylic sheet such as EXITS, EMERGENCY
EXIT, DO NOT USE LIFT DURING FIRE, FLOOR
MARKINGS, FIRE LIFT, STAIRCASE EXIT, FIRE ALARM
CALL POINT, FIRE HOSE REEL, FIRE HYDRANT POINT
196 Supply, Installtion, Testing & Commissioing of 50.00 No 556.36
Standard Response Sprinkler, Pendent Brass Sprinkler,
Quartzoid Bulb type with crome finish, nickel crome
platde, K factor K-80, Temp.- 68 C, 1/2" end connection
including resessed escutcheon. (UL Listed).
197 Supply, installation, testing & commissioning of 2.00 No 2824.58
pressure switch. (Range 0 to 16 kg/cm2)
198 Supply, installation, testing & commissioning of 150 2.00 No 2738.99
mm dia. dial Burdon Type Glycerine Filled pressure
gauge with isolation ball valve arrangements with
necessary isolation valves with all complete.( Range
199 Supply, Installation, Testing & Commissioning of Cast 3.00 No 2011.45
iron body Butterfly valve according to IS: 13095, PN-
1.6, Iron Disc for size 150 mm dia. & below Lever
operated and above 150 mm dia. Gear operated
complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc.,
with all complete. 50 mm dia.
200 Supply, Installation, Testing & Commissioning of Cast 2.00 No 2567.80
iron body Butterfly valve according to IS: 13095, PN-
1.6, Iron Disc for size 150 mm dia. & below Lever
operated and above 150 mm dia. Gear operated
complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc.,
with all complete. 80 mm dia.
201 Supply, Installation, Testing & Commissioning of Cast 2.00 No 3124.15
iron body Butterfly valve according to IS: 13095, PN-
1.6, Iron Disc for size 150 mm dia. & below Lever
operated and above 150 mm dia. Gear operated
complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc.,
with all complete. 100 mm dia.
202 Supply, Installation, Testing & Commissioning of Cast 1.00 No 4493.64
iron body Butterfly valve according to IS: 13095, PN-
1.6, Iron Disc for size 150 mm dia. & below Lever
operated and above 150 mm dia. Gear operated
complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc.,
with all complete. 150 mm dia.
203 Supply, installation, testing & commissioning of Cast 3.00 No 1540.67
iron body Dual Plate Wafer Type NRV conf. to IS:
PN-1.6 complete with mating Flanges class # 150 with
bolts & nuts, washers, gaskets 3 mm thick, etc., with all
complete Accessories 50 mm dia.
204 Supply, installation, testing & commissioning of Cast 2.00 No 2225.42
iron body Dual Plate Wafer Type NRV conf. to IS:
PN-1.6 complete with mating Flanges class # 150 with
bolts & nuts, washers, gaskets 3 mm thick, etc., with all
complete Accessories 80 mm dia.
205 Supply, installation, testing & commissioning of Cast 3.00 No 3166.95
iron body Dual Plate Wafer Type NRV conf. to IS:
PN-1.6 complete with mating Flanges class # 150 with
bolts & nuts, washers, gaskets 3 mm thick, etc., with all
complete Accessories 100 mm dia.
206 Supply, installation, testing & commissioning of Cast 1.00 No 5820.34
iron body Dual Plate Wafer Type NRV conf. to IS:
PN-1.6 complete with mating Flanges class # 150 with
bolts & nuts, washers, gaskets 3 mm thick, etc., with all
complete Accessories 150 mm dia.
207 Supply, installation, testing & commissioning of SG 1.00 No 1112.71
iron body SinglePlate Wafer Type NRV conf. to ASTMA
536, PN-1.6 complete with mating Flanges class #
with bolts & nuts, washers, gaskets 3 mm thick, etc.,
with all complete. Accessories 50 mm dia.
208 Supply, installation, testing & commissioning of SG 1.00 No 1455.09
iron body SinglePlate Wafer Type NRV conf. to ASTMA
536, PN-1.6 complete with mating Flanges class #
with bolts & nuts, washers, gaskets 3 mm thick, etc.,
with all complete. Accessories 80 mm dia.
209 Supply, installation, testing & commissioning of SG 1.00 No 1797.46
iron body SinglePlate Wafer Type NRV conf. to ASTMA
536, PN-1.6 complete with mating Flanges class #
with bolts & nuts, washers, gaskets 3 mm thick, etc.,
with all complete. Accessories 100 mm dia.
210 Supply, installation, testing & commissioning of Y 1.00 No 5563.55
Type Strainer complete with mating flanges with bolts
& nuts, washers, gaskets 3 mm thick, etc., with all
complete accessories. 80 mm dia.
211 Supply, installation, testing & commissioning of Y 1.00 No 7275.42
Type Strainer complete with mating flanges with bolts
& nuts, washers, gaskets 3 mm thick, etc., with all
complete accessories. 100 mm dia.
212 Supply, installing, testing and commissioning of 1.00 No 4194.07
Normax make CI heavy duty ball type foot valve with
flanges, nut bolts, gaskets etc. with necessary complete
accessories. 80 mm dia.
213 Supply, installing, testing and commissioning of 1.00 No 6162.71
Normax make CI heavy duty ball type foot valve with
flanges, nut bolts, gaskets etc. with necessary complete
accessories. 100 mm dia.
214 Supply, installation, testing & commissioning of Four 1.00 No 8987.29
way fire brigade Inlet connection with 63 mm dia.
stainless steel (SS304) instantaneous male inlets with
built in non return valve in each inlet with 150 mm dia.
header pipe, suitable rubber cap and GI chain including
nuts, bolts, washers, gasket 3 mm thick, etc. with all
215 Supplying FIRE bucket round bottom of 9 liters 8.00 No 1027.12
capacity made out of 24 gauge G.I Sheet with extra
handle at bottom duly painted white inside and Red
out side with FIRE mark. Filled with dry-sand and kept
on existing stand provided or hung on wall hook.
216 Supplying and erecting floor mounting Stand for 2.00 No 5563.56
keeping four nos. of FIRE buckets comprising
mm in length, 900 mm height frame made out of
30mm x 30 mm x 4 mm angle iron with cross supports
legs, welded with 4 hooks and duly painted with one
coat of primer and two coats of approved enamel PO
red paint.
217 Supply & installation of stainless steel body Orifice 5.00 No 1069.91
Plate of suitable inner bore along with matching flange -
as per specification & requirement as per hydraulic
calculation.
218 Supply, installation, testing & commissioning of 5.00 No 5435.17
Oblique pattern type stainless steel (SS 304) single
headed External Fire Hydrant Valve with 63 mm dia.
female instantaneous outlet conf. to IS: 5290, type - A,
including mating flanges, galvanised nuts, galvanised
bolts/studs, washers & gaskets 3 mm thick with all
219 Supply, installation, testing & commissioning of 63 mm 5.00 No 1754.66
dia. stainless steel (SS 304) Universal Branch Pipe
conf. to IS:
220 Supply & installation, testing & commissioing of Fire 5.00 No 6967.29
Fighting Hose - conf. to IS : 636, type B (type- 3), The
fire hose shall be 15 m long with 63 mm dia. stainless
steel (SS 304) couplings conf. to IS: 903, at both the
ends for connection with the hydrant valve and the
branch pipe.
221 Supply, installation, testing & commissioning of 5.00 No 2525.00
fabricated from 3 mm MS sheet, hose box of size-450
mm x 600 mm x 250 mm - painted with Fire Red as per
IS: 5, shade no. 536 front 3 mm thick transparent glass
with lock & key, handle and brass hinges - to
accommodate one number of 15 mtr long hose and one
number of universal branch pipe, including supporting
arrangement with civil work.
222 Supply, Installation, testing & commissioing of 5.00 No 7403.82
Swinging type mild steel hose reel drum with 20 mm
dia. x 30 mtr. rubber hose as per IS: 884. The mounting
stand shall be of mild steel and the hose shall be fitted
with a SS shut-off nozzle & SS ball valve of 25 mm dia.
including supporting arrangement with all complete.
accessories
223 Supplying, fixing & testing of of CI ball Valve 25mm dia. 15.00 No 706.14
224 Supplying, fixing & testing of New Battery of diesel 1.00 No 15834.75
engine 150 Amp.
225 Supply and installation of Diesel Tank For Diesel 1.00 No 16690.67
Engine With All Accessories 100 Ltrs.
226 Supplying, filling & testing lube oil for diesel engine 20.00 Ltrs 320.98
227 Supply and commissioning of Oil Filter. 1.00 No 706.14
228 Supplying, filling of diesel in diesel engine tank 75.00 Ltrs 89.87
229 Supply and commissioning of Diesel Filter 1.00 No 427.97
230 Supplying, filling & testing coolant to engine cooling for 20.00 Ltrs 239.66
231 Filling Of Gaps Between pipe and Core Cutting Hole 16.00 No 299.58
With Chemical and Cement
232 Steel work, welded in built up sections framed work 150.00 Kg 84.13
including cutting, hoisting, fixing in position and
applying a priming coat of read lead paint & two coat
oil paint. (A)In beams and joists, channels angles Tees,
flats, with connecting plates or angle cleats as in main
and cross beams. Hip and jack rafters, purlins
conneted to common rafters and the like.
233 Supplying & erecting XLPE(IS:7098)(I)-88 ISI 20.00 Mtr 136.35
unarmoured copper cable 1.1 KV grade to be erected
as directed of following size. (E) 3 core 2.5 Sq. mm for
pressure switch
234 Providing and erecting XLPE(IS:7098)(I)-88 ISI 20.00 Mtr 285.83
armoured cable multistrand Copper conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of
following size of cable. (Only Fire Panel to Fire Pump)
(B) 3 core 4 Sq. mm
235 Providing and erecting XLPE(IS:7098)(I)-88 ISI 20.00 Mtr 497.93
armoured cable multistrand Copper conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of
following size of cable. (Only Fire Panel to Fire Pump)
(D) 3 core 10 Sq. mm (Only Fire Panel to Fire Pump)
236 Providing and erecting XLPE(IS:7098)(I)-88 ISI 20.00 Mtr 213.11
armoured cable multistrand Copper conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of
following size of cable for Diesel Engine Battery
Charger (A) 3 core 2.5Sq. mm
237 Supply, Filling and Fixing of approved make ABC type 6.00 No 1968.64
fire extinguisher - 6 Kg. Capacity as per IS:15683 & IS :
238 Supply, Filling and Fixing of approved make CO2 type 6.00 No 5520.76
fire extinguisher. Capacity 4.5 Kg. (conforming to IS-
239 Supply, Filling and Fixing of approved make ABC 2.00 No 3423.73
Moduler type automatic fire extinguisher. Capacity
Kg. (conforming to IS-15683).
240 Submitting the application to obtain Fire Plan 1.00 No 202000.00
Approval and After Completion of Work Obtain Final
Fire NOC for 3 Year.
241 Supply, Installation and commissioning of Air Release 1.00 No 1412.29
Valve, 25 mm Dia. connection.
242 Supply, Installation and commissioning of Fire Alarm 1.00 No 15150.00
Panel Conventional type, 2 zone, with complete
accessories.
243 Supply, Installation and commissioning of smoke 50.00 No 1027.12
detectors / heat detectors, with complete accessories.
244 Supply, Installation and commissioning of plug in base 50.00 No 256.78
for the smoke detectors, hooters, with complete
accessories.
245 Supply, Installation and commissioning of Audio 5.00 No 1069.91
hooters , with complete accessories.
246 Supply, Installation and commissioning of Manual Call 5.00 No 1010.00
Points, with complete accessories.
247 Providing and erecting XLPE(IS:7098)(I)-88 ISI 600.00 Mtr 176.75
armoured cable multistrand Copper conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (A)
core 2.5 Sq. mm for Fire Alarm System
248 Core cutting in wall and in RCC slab with size as below: 6.00 No 342.37
50 mm dia. Hole
249 Core cutting in wall and in RCC slab with size as below: 4.00 No 427.97
80 mm dia. Hole
250 Core cutting in wall and in RCC slab with size as below: 2.00 No 513.56
100 mm dia. Hole
251 Core cutting in wall and in RCC slab with size as below: 2.00 No 599.15
150 mm dia. Hole
252 Core cutting in wall and in RCC slab with size as below: 2.00 No 855.93
200 mm dia. Hole
253 Supplying, installing, testing and commissioning of 1.00 Set 447652.54
Kirloskar make diesel engine driven fire hydrant pump
set, suitable for automatic operation and consisting of
horizontal type centrifugal end suction back pull-out,
top discharge pump with cast iron body and bronze
impeller, mounted on M.S. fabricated common base
plate with coupling, coupling guard, foundation bolts
and all necessary accessories, complete as required.
The pump shall be of Model KFE, having a discharge
capacity of 137 m³/hr at 70 meters head, driven by a
62 HP diesel engine, 3 phase, with suction and delivery
size of 125 mm x 100 mm.
254 Fire Hydrant Panel suitable for 10 HP Jockey Pump, 62 1.00 No 141400.00
HP (137 m³/hr @ 70 m head) Diesel Engine Operated
Pump, consisting of Incomer with MCCB (1 No.), R Y B
Indication (1 Set) and VAF Digital Meter (1 Set);
Outgoing with F2 – 10 HP DOL Starter for Jockey
Pump, F3 – Auto On/Off Diesel Pump with Battery
Charger, Control Circuit with Auto/Manual On/Off,
On/Off Trip Indication and On/Off Push Button;
Fabrication duly powder coated in PO Red Colour,
fabricated from 14/16 SWG GI Sheet with IP-42
Protection, fixed type floor mounted with bottom cable
entry, complete as required.
255 Pay Legal Fees to Concern Authority for Obtaining Plan 1004.00 Sq.mt 12.12
Approval and Final NOC
256 Dismentling of doors, windows, ventilators etc. (wood 56.00 No. 201.79
or steel) shutters including chowkhats architraves,
holdfasts and other attachment etc. complete and
stacking them within all lead and lift (ii) Not Exceeding
3 Sq.M. in area.
257 Dismentaling tiled of stone floors laid in mortar 348.00 Sqm 51.82
including stacking of serviceable materials and
disposal of unserviceable materials with all lead and
258 Dismentling wood work, wrought framed and fixed in 10.00 Cum 1891.33
fram es trusses including stacking the materials with
all lead and lift.
259 Demolition of terrace including stacking of serviceable 191.00 sqm 68.59
materilas and disposal of unserviceable materials with
all lead and lift.(i) Brick tile covering.
260 Demolition including stacking of serviceable materilas 53.50 Cum 1137.19
and disposal of unserviceable materials with all lead
and lift. (i) R.C.C. work
261 Demolition of Brick work and stone masonry including 216.37 Cumt 591.68
stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(ii) In
Cement Mortar.
262 Dismentling steel work including distempering and 3439.00 Kg 3.94
stacking the materials with all lead and lift.
263 Dismentling C.I. pipes G.S.W.pipes abd A.C. rain water 147.00 Rmt 80.72
pipes with fittings and clamps including stacking the
materials with all lead and lift ( for any dia, of pipe)
264 Dismantling santtary fittings like wash basin . W.C. pan 6.00 Nos 436.07
Indian and European type, flushing tank etc. including
stacking the materials with all lead and lift.
265 Point wiring for Tissino / Modular secondary light 38.00 Pt. 167.66
point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires, in below type of
pipe to be erected complete with earth continuity and
necessary connection with primary light with
accessories erected on Metal / PVC / wooden box
covered with 3 mm thick PC(Polycarbonate) / Acrylic
sheet for open / concealed wiring. with necessary
Lamp holder / ceiling rose / H.D.Connector as directed.
Note:- Maximum up to 6 mtrs length, excess will be
considered as Mains for Secondary Point. (f) with
medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete
266 Point wiring for Light / Bell with 2-1.5 sq.mm & 214.00 Pt. 485.81
earth wire of 1.5 sq.mm (Green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length , in below type of pipe
erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type,
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector
as directed.(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete Cat.III
267 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 62.00 Pt. 674.68
1.5 sq.mm (Green) both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step
type electronic fan regulator mounted and
accessories with earth continuity of following type
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as directed. (f)
with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat.III
268 Point wiring for Individual Plug with & earth wire of 6.00 Pt. 510.05
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires up to
mtr length, in below type of pipe erected complete
with Modular type switch & 5 pin Plug erected on PVC
/ Metallic/Wooden box covered with appropriate front
plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories. [I] For 6A
Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from
nearby switchboard/mcb db board (f) with medium
class Rigid PVC pipe and accessories erected concealed
in wall/ceiling complete Cat.III
269 Point wiring for Individual Plug with & earth wire of 15.00 Pt. 871.63
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires up to
mtr length, in below type of pipe erected complete
with Modular type switch & 5 pin Plug erected on PVC
/ Metallic/Wooden box covered with appropriate front
plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories. [III] For
16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire
with 2.5 sq.mm ( green) earthing wire from mcb d b
board. (f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete Cat.III
270 Point wiring for on board Looped Plug with 6A 49.00 Pt. 257.55
Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following
type accessories Cat.III
271 Providing following type of Modular Type Accessories 44.00 Ea. 160.59
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed by
Engineer In charge. (3) Two Pin/RJ-11 Telephone
Socket [A] For One Gang Cat.III
272 Providing following type of Modular Type Accessories 29.00 Ea. 25.25
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed by
Engineer In charge. (7) Blank Plate Single Cat.III
273 Providing following type of Modular Type Accessories 44.00 Ea. 160.59
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed by
Engineer In charge. (8) Computer RJ-45 socket Cat.III
274 Providing and erecting ISI mark Medium class RIGID 52.00 Mtr. 24.24
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in approved
manner as directed (a)20 mm
275 Providing and erecting ISI mark Medium class RIGID 1012.00 Mtr. 33.33
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in approved
manner as directed (b) 25 mm
276 Providing and erecting Mains with 1.1 KV grade FRLS 1395.00 Mtr. 82.82
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed
in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) With
medium class Rigid PVC pipe and accessories (b)
wire 2.5 sq. mm
277 providing and erecting Mains with 1.1 KV grade FRLS 60.00 Mtr. 147.46
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on wall
/ ceiling with 2.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth
continuity of following size (A) with medium class
Rigid PVC pipe and accessories (b) 2 wire 6 sq. mm
278 providing and erecting Mains with 1.1 KV grade FRLS 200.00 Mtr. 260.58
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on wall
/ ceiling with 2.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth
continuity of following size (A) with medium class
Rigid PVC pipe and accessories (h) 4 wire 6 sq. mm
279 providing and erecting Mains with ISI marked, 1.5KV 57.00 Mtr. 56.56
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
required. (e) One wire 6.00 sq. mm
280 providing and erecting Mains with ISI marked, 1.5KV 51.00 Mtr. 91.91
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
required. (f) One wire 10.00 sq. mm
281 providing and erecting Mains with ISI marked, 1.5KV 18.00 Mtr. 142.41
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
required. (g) One wire 16.00 sq. mm
282 providing and erecting Mains with ISI marked, 1.5KV 10.00 Mtr. 236.34
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
required. (h) One wire 25.00 sq. mm
283 Supplying and erecting Flexible PVC insulated multi 60.00 Mtr. 22.22
strand multi core 1.1 kv grade ISI marked copper wires
of following size to be erected as directed. (c)
Sq.mm 2 core round/ flat PVC sheathed
284 Supplying and erecting Flexible PVC insulated multi 86.00 Mtr. 46.46
strand multi core 1.1 kv grade ISI marked copper wires
of following size to be erected as directed. (e)
Sq.mm 3 core round PVC sheathed
285 Supplying & erecting approved make Telephone Cable 1100.00 Mtr. 20.20
electrolytic copper conductor PE insulation twisted in
two pairs, & wrapped with FRLS PVC tape & sheathed
with FRLS PVC or HFFR outer Jacket suitable for
telephone wiring & confirming to C-DOT erected in
existing pipe. of following size of conductors & nos.of
pairs. With necessary connections. [A] Conductor Size
0.5 mm (a) Unarmoured (2) Two Pairs
286 Supplying & erecting approved make Telephone Cable 20.00 Mtr. 199.98
electrolytic copper conductor PE insulation twisted in
two pairs, & wrapped with FRLS PVC tape & sheathed
with FRLS PVC or HFFR outer Jacket suitable for
telephone wiring & confirming to C-DOT erected in
existing pipe. of following size of conductors & nos.of
pairs. With necessary connections. [A] Conductor Size
0.5 mm (b) Armoured [Jelly Filled] (2) Twenty Pairs
287 Supplying & erecting approved make LAN cable of 1100.00 Mtr. 47.47
following size in existing pipe as per direction [C] CAT -
288 Providing & erecting main Distribution (MDF) indoor 1.00 Ea. 1368.55
type, back mounted frame as per DoT standard
approved with krone strips (b) Suitable for 20 pair
289 Providing & erecting main Distribution (MDF) indoor 1.00 Ea. 1747.30
type, back mounted frame as per DoT standard
approved with krone strips (c) Suitable for 50 pair
290 Providing & erecting Switch board for Computer or 44.00 Ea. 1133.22
electric apparatus consisting of following modular
type accessories mounted with PVC / Metallic
concealed/open box with single mounting base frame
covered with textured/metallic /white front
plate,modules erected with necessary connections as
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories
291 Decorative call bell Ting-tong box type 250 volts 10.00 Ea. 71.71
complete erected
292 Supplying and erecting LED indoor fittings with LEDs 84.00 Ea. 535.30
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more than
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
shown.) (A) Tube Light with integral driver (v) 36-40
Watts, Surge-2 KV, IP-20, conventional 4 feet Cat.III
293 Supplying and erecting led lamps with following 14.00 Ea. 112.11
wattage capacity of 220 to 240 voltage, minimum
15000 burning hours life, 500 V in built-surge
protection,Polycarbonate diffuser, mounting suitable
for E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED
Lamps integral type, with PC diffuser suitable LAMP
holder (ii) 5 to 8 watts Cat.III
294 Supplying and erecting LED indoor fittings with LEDs 103.00 Ea. 758.51
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD <
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
shown.) (A) Square/ Circular shaped
Surface/Recessed Mount Downlight with provision for
spring loaded mounting clips complete.IP20 (iv) 22-24
watts, Surge-2 KV Cat.III
295 Supplying and erecting LED indoor fittings with LEDs 21.00 Ea. 1794.77
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD <
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
shown.) (B) LED Panel Light with provision for Plane
front frame with translucent cover fixed to housing
complete.IP20 (vi) 36 watts, 24" x 24", Surge- 2KV
296 Supplying and erecting LED street light / Flood light 21.00 Ea. 4997.48
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die
cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 &
LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The
between the ranges shown.) (A) Street Light (IP-65),
Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection. (ii)
above 48 to 60 Watts Cat.III
297 Supplying and erecting LED street light / Flood light 2.00 Ea. 4819.72
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die
cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 &
LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The
between the ranges shown.) (C) Post Top Lantern LED
fitting comprises of finish cast aluminum spigot and
spun aluminum canopy fixed with opal polycarbonate,
pipe arrangement for vertical mounting driver and
accessories wired upto terminal block.IP 65 (ii)32-
40W Cat.III
298 Providing and erecting Approved make Four pole 17.00 Ea. 6173.12
moulded case circuit breaker having breaking capacity
ICU of 25 KA. at 415 V,having normal current rating up
to 25 A to 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all internal
connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing. ICS=100% of ICU
only Cat III
299 Providing and erecting Approved make Four pole 6.00 Ea. 8055.76
moulded case circuit breaker having breaking capacity
ICU of 35 KA. at 415 V. having normal current rating
125A. with Fixed thermal & magnetic release suitable
to work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing. ICS=100% of ICU
only Cat III
300 Providing and erecting Approved make Four pole 2.00 Ea. 20946.39
moulded case circuit breaker having breaking capacity
ICU of 35 KA. and above at 415 V . having normal
current rating 250A. with variable thermal & magnetic
release suitable to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III
301 Providing and erecting Approved make Earth fault 1.00 Ea. 5415.62
Relay suitable to mount with inter connection suitable
to following size of moulded case circuit breaker
having CT ratio & MCCB rating as following along with
shunt trip 220V AC. with all internal connections &
complete erected in existing M.S.housing. (3) 250 A -
400 A , CT Ratio 1/400
302 Supplying and erecting triple pole & neutral 440V / 1.60 Rn.Mt 1961.42
500V panel mounting Copper Busbars with four equal r
Nos. of electrolyte bus having current density not more
than 1.6 Amp. / sq.mm (Rated current / cross section
area) duly wrapped with colour insulating tape for
phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators,
main cable socket to each bar, erected in existing
cubical panel with necessary connections. (A) Suitable
for 100 Amp. Capacity
303 Supplying and erecting triple pole & neutral 440V / 1.60 Rn.Mt 3202.71
500V panel mounting Copper Busbars with four equal r
Nos. of electrolyte bus having current density not more
than 1.6 Amp. / sq.mm (Rated current / cross section
area) duly wrapped with colour insulating tape for
phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators,
main cable socket to each bar, erected in existing
cubical panel with necessary connections. (B) Suitable
for 200 Amp. capacity
304 providing and erecting Miniature circuit breaker single 21.00 Ea. 270.68
pole 0.5A to 2A system and having breaking capacity
10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
305 providing and erecting Miniature circuit breaker single 120.00 Ea. 112.11
pole 6A to 25A suitable to operate on 240 V A.C.
system and having breaking capacity 10 KA to be
erected in existing box. confirming to IS 8828/1996
with ISI Mark Cat.III
306 Providing & erecting 240 V MCB double pole switch for 4.00 Ea. 278.76
lighting Load (B Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (A) 6 to 32 Amp. Cat.III
307 Providing & erecting 240 V MCB double pole switch for 10.00 Ea. 295.93
lighting Load (B Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (B) 40 Amp. Cat.III
308 Providing & erecting 415V MCB Four Pole Switch for 5.00 Ea. 638.32
Lighting Load (B curve) having 10KA breaking capacity
& confirms to IS :8828 in existing box having following
capacity (b)40 Amp. Cat.III
309 Providing & erecting 415 V MCB Four Pole for Motor & 12.00 Ea. 668.62
Inductive Load (C Curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
following capacity (b)40 Amp. Cat.III
310 Providing and erecting Sheet Steel powder coated MCB 1.00 Ea. 629.23
distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
suitable for (A) single phase incoming and horizontal
single phase outgoing (b) sheet steel double door (IP-
311 Providing and erecting Sheet Steel powder coated MCB 3.00 Ea. 1492.78
distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
suitable for (A) single phase incoming and horizontal
single phase outgoing (b) sheet steel double door (IP-
43) (iv)12 way
312 Providing and erecting Sheet Steel powder coated MCB 8.00 Ea. 2339.16
distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
suitable for (B) three phase incoming and single phase
horizontal type outgoing Per phase isolation type
(PPI) (b) sheet steel double door (i)4 way
313 providing and erecting Approved make RCCBs 28.00 Ea. 1969.50
conforming to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz.
having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic
component. for following Max. rating erected as
directed (i) 25 Amps.DP Cat.III
314 Providing and erecting Annealed bare Copper wire 8 to 11.00 Kg 794.87
315 Providing and erecting Pipe type earthing having 150 6.00 Ea. 368.65
cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth
pit complete with necessary 8 SWG earth wire.
316 For using salt and charcoal / coke as required for pipe 6.00 Ea. 171.70
type earthing.
317 Supplying & erecting in earthpit of minimum bore dia. 5.00 Ea. 7095.25
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250
Micron galvanising, connection terminal dia of
mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation
suitable for following type of applications with
chamber and heavy duty cover (A)(approved make
OEM has to submit test certificate including value of
earth resistance of installation duly stamped and
signed by agency and officer Incharge has to ensure
the value of earthing resistane mentioned in test
Certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm
/ meter testing as per IEC 62561-2017, Voltage drop:-
< 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound
should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
[B] For Electrical installation up to 11 KV located in
other than normal soil i.e. Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of 25 Kg.
318 Providing & erecting weather proof, dust & vermin 4.00 Sq.Mtr 10468.65
Providing & erecting weather proof, dust & vermin
proof, floor mounted front operated indoor type
cubical panel board necessary IP-42 and above
protection as per approval from engineer incharge
made from 14 SWG thick CRC M.S. sheet for outer body
& doors, 16 SWG thick CRC M.S.sheet for internal
partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending,
drilling, welding, riveting with internal partitions &
cable alley as per requirements & instruction of
engineer-in-charge with erection of supplied switch
gears, BUSBARS, suitable size of inter connecting PVC
copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for
measuring instruments, earth bus & earth bolts,
foundation flange - bolts-base Plates, sufficient nos. of
hinged doors, handles with locking arrangement and
rubber gasket,heavy duty end terminal
connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be
painted with epoxy powder coating. (The rates
excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips, meters,
Fuses etc. The dimension shall be measured excluding
base beams) The panel shall be supplied with
following approved manufacturers with following size.
(A) locally fabricated panel board (i) with 350 mm
319 Providing , erecting , fabricating the M.S. structure as 70.00 Kg. 77.77
per requirement on site incorporating proper size of
M.S. angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing
duly painted with one coat of red oxide with erection
on site as per direction of engineer in charge with
necessary grouting, cementing, plastering & finishing
320 Providing and erecting XLPE(IS:7098)(I)-88 ISI 70.00 Mtr. 92.92
armoured cable Aluminium conductor for 1.1 KV. to
be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables. (B) 2 core
321 Providing and erecting XLPE(IS:7098)(I)-88 ISI 60.00 Mtr. 284.82
armoured cable multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (C)
1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
322 Providing and erecting XLPE(IS:7098)(I)-88 ISI 80.00 Mtr. 490.86
armoured cable multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (E)
1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
323 Providing and erecting XLPE (IS:7098)(I)-88 ISI 302.00 Mtr. 126.25
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (B) 4 core 6 Sq. mm
324 Providing and erecting XLPE (IS:7098)(I)-88 ISI 150.00 Mtr. 140.39
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (C) 4 core 10 Sq. mm
325 Making trench in soft soil of suitable width of 90 cm 410.00 Mtr. 55.55
deep for laying cable or locating the fault all over the
run and back filling the same and making the surface
as normal ground.
326 Supplying following size of Light duty “A” Class G.I . 25.00 Mtr. 471.67
Pipe & erecting as directed by Engineer-in-charge. (C)
80 mm dia.
327 Providing & laying approved make Double walled 365.00 Mtr. 62.62
corrugated pipes (DWC) of polyethylene(conforming
to IS 14930 II )with necessary connecting accessories
of same material at required depth in existing trench
for laying of cable. below ground / road surface for
enclosing cable (A)50 mm outer dia
328 Providing & laying approved make Double walled 20.00 Mtr. 95.95
corrugated pipes (DWC) of polyethylene(conforming
to IS 14930 II )with necessary connecting accessories
of same material at required depth in existing trench
for laying of cable. below ground / road surface for
enclosing cable (C))90 mm outer dia
329 Providing and, fixing heavy duty flange type brass 6.00 Ea. 38.38
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
insulating tape etc for following size of cables. (C) 2 to
4 core 10 Sq. mm
330 Providing and, fixing heavy duty flange type brass 6.00 Ea. 75.75
double compression type cable gland with rubber
ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of
cables. (B) 3 & 1/2 core 35/50 Sq. mm
331 Providing and, fixing heavy duty flange type brass 4.00 Ea. 131.30
double compression type cable gland with rubber
ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of
cables. (D) 3 & 1/2 core 95 Sq. mm
332 Solder less crimping type Aluminium lugs conforming 144.00 Ea. 6.06
to IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an
approved manner. (A) 1.5/ 2.5/4/6 Sq.mm
333 Solder less crimping type Aluminium lugs conforming 24.00 Ea. 13.13
to IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an
approved manner. (B) 10 Sq.mm
334 Solder less crimping type Aluminium lugs conforming 24.00 Ea. 20.20
to IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an
approved manner. (D) 35/50 Sq.mm.
335 Solder less crimping type Aluminium lugs conforming 16.00 Ea. 40.40
to IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an
approved manner. (G) 120 Sq.mm.(F) 95 Sq.mm.
336 Providing and erecting Approved make Ceiling fan 62.00 Ea. 1596.81
with double ball bearing ISI mark with condenser A.C.
23OV.50 c/s.1200 mm. sweep complete, canopy
erected on existing hook or clamp with earthing. [Make
shall be approved by Engineer in charge]
337 Replacing old & u/s by Supplying and erecting 19 / 20 62.00 Mtr. 108.07
mm. nominal bore Medium Class M.S. Pipe down rod
erected duly painted for fan complete with proper
insulation without leakage and earthing.
338 Supplying & erecting fan hook box of 10 mm M.S. 62.00 Ea. 108.07
round bar bounded to the RCC bars up to 50mm length
each side and pierced through a 16 Gauge M.S. box /
Heavy Duty PVC box complete erected concealed in
Ceiling with necessary finishing.
339 Providing 2.5mm.thick laminated acrylic sheet to cover 62.00 Ea. 18.18
the fan hook or Fan box.
340 Supplying & erecting approved make low noise 17.00 Ea. 1366.53
decorative exhaust fan having square frame ABS body
with inbuilt lowers & square frame. 250mm with
RPM Cat.II
341 Supplying and erecting approved make Octagonal pole 9.00 Ea. 6874.06
made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as
per IS 2629/2633/4759, suitable suspend local wind
speed with integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable termination to be
erected With Suitable foundation (Included) as per
details given by manufacturer considering site
requirement. (C) 5 Mtr. Long 70 mm Top X 130 mm
bottom dia, 3 mm thickness with
200mmX200mmX12mm base plate, 4-M16 Bolts and
600mm long with necessary G.I. J Bolts .Approx Pole
weight 46 kg
342 Supplying & erecting approved make SMC press 10.00 Ea. 515.10
moulded composite FRP. loop-in, loop-out approx.
2mm thick box complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps& earth
bolt of following size of box. (B) 250mm x 200mm x
100mm [deep]
343 Supplying and erecting Street light pole bracket 7.00 Ea. 491.87
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class G.I. sleeve
tubing of approx. 45cms.length and suitable for
76.5mm/80mm/require size of pole top having nuts
and bolts for fixing the brackets and having spread of
0.5 mtr. Length with 110 deg.with vertical plane and
suitable welded stiffener reducer and nipple with
check nut complete painted with one coat.of Red oxide
/ PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms. [A] Single Arm
bracket 0.5 Mtr
344 Supplying and erecting Street light pole bracket 2.00 Ea. 622.16
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class G.I. sleeve
tubing of approx. 45cms.length and suitable for
76.5mm/80mm/require size of pole top having nuts
and bolts for fixing the brackets and having spread of
0.5 mtr. Length with 110 deg.with vertical plane and
suitable welded stiffener reducer and nipple with
check nut complete painted with one coat.of Red oxide
/ PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms. [B] Double Arm
Bracket 0.5 Mtr
345 Supplying and erecting B class galvanised iron pipe 32 8.00 Ea. 343.40
mm outside dia 45 cm long duly welded on 20 cm x
cm x 3 mm thick M.S. base plate, erected on wall or
corner for mounting street light luminaire with
necessary hardware materials duly painted.
346 SITC of Digital / PCM / TDM EPABX System having 1.00 Ea. 77077.14
SMT design, system with flexible universal slots.
Inbuilt Auto attendant facility, Minimum 15 Nos.
conference, Analog extension line, Calling GSM, E&M
line, PRI / EI & VOIP program me through Analog
telephone digital key from Ethernet, public address
cord, shall have unrestricted simultaneous dialing
QSIG protocol on PRI, 95 / STD / ISD / Local-Locking,
Class of Service, Quick Dial-Single Digit dialing of any
two external number, Once only ring device, Chairman
/ Secretary - Do not disturb Facility, Power Down
Mode, Hot Line, Hot Outward Dialing, Day Night Mode,
Auto Call Back, Barge-in, Call Pick Up & Call Transfer,
Call transfer while Ringing with Voice Guide System,
(DISA), Caller ID (CLI), CLI Base ECF, CLI Base routing
Internet Ready Port, External Music Port, Call
Budgeting, Call Most Calculation (ASMDR), DID Direct
Inverse Dialing, External Music Input, Fax Homing,
Global Directory Printing with following capacities
[[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ] [C] No of Extension 48, No
of Junctions 9, 8 Port IP Resource in-built, 4 Port Web
base Video Conferencing, No of expandable ports :
Operators Console - 01 Compatible : ISDN
347 Providing & erecting, programming, testing of 1.00 Ea. 5992.33
chairman unit microphone with flexible stem of
mm in length and light ring built in loud speaker ,two
head phone socket ,attractive design ,priority button
for chairman microphone,built in volume control for
head phones,chime tone facility to precede chairman
priority calls,microphone on/off button,red indicates
for microphone is active,frequency response -400Hz to
10kHz,nominal acoustic input -85 dB SPL [[Approved
by Competent Authority i.e. not Below the rank of
Executive Engineer ]
348 Providing & erecting, programming, testing of Delegate 8.00 Ea. 5565.10
unit microphone with flexible stem of 480 mm in
length and light ring built in loud speaker ,two head
phone socket ,attractive design ,built in volume control
for head phones,chime tone facility to precede
chairman priority calls,microphone on/off button,red
indicates for microphone is active,frequency response -
400Hz to 10kHz,nominal acoustic input -85 dB SPL
[[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
349 Supplying & erecting dual channel amplifier ,power 1.00 Ea. 11128.18
handling capacity of 180 watt ,four micro phone inputs
with independent level control ,built in FM tuner,with
preset memories,USB drive & SD card for MP3
playback ,100v /telephone input with priority and
VOX,frequency response-80 Hz to 18k Hz Philips /
/distortion less than 1% @ rated power up to 50 units
[[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
350 Supplying and erecting ceiling speaker with rated 6.00 Ea. 2569.44
power of 30 watt/power tapping 30/15/7.5 watt
available,opening angle 180 degree H * 77 degree V
,sound pressure level 88 dB ,frequency response of
70Hz to 20KHz [[Approved by Competent Authority i.e.
not Below the rank of Executive Engineer ]
351 Providing and erecting Inverter based approved make 2.00 Ea. 48257.80
split air-conditioning unit consisting of condensing
unit with variable speed fan motor, inverter type
hermetically sealed rotary compressor with
accessories etc. duly connected separately erected
evaporating unit and blower motor with its
accessories by means of extra supplied proper
insulated copper tubing,drain PVC pipes suitable for (
cost includes Eco Friendly green gas charging and 15A
plug top & Remote Control & MS Stand) with necessary
core cutting. (1)For ISEER Range (KWH/KWH)(3.1 to
3.99) (B) for 1.5 ton capacity - Premium Cat.
352 Supplying and erecting insulated pair of soft copper 16.00 Rmt 965.56
tubing open or concealed including power and control
cable,necessary PVC drain pipes for Split AC machine
up to 4 TR capacity
353 Providing & erecting water cooler having storage 2.00 Ea. 55893.40
capacity 150 Ltr. & cooling capacity 150 Ltr.per hour
@ an ambient temp of 45˚ C. The outlet temp. of the
water should drop by 15˚C within a hour, The water
cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank
surrounded by evaporating, coil, thermostats, relay
etc.complete with necessary inlet & outlet connection.
The body of water cooler will be made from Stainless
354 Supplying & erecting 5 stage single reverse osmosis 2.00 Ea. 29187.99
water purification system with M.S. powder coated
frame, prefilter housing with 'O' ring presediment
filter GAC filter, carbon filter suitable buster DC pump
capacity 80 psi, mention with 40 psi inline type post
carbon filter auto low & high pressure switches with
following size of storage tank & LPH capacity & erected
as directed [C] 50 Ltr / Hr with 150 psi 2 nos booster
355 Supplying and erecting approved make panel 1.00 Ea. 1275.63
mounting type Digital Voltmeter having 3 digits LED
display, 0 to 750 AC Volts range erected on existing
panel board with all connection, wiring etc .with
manufacturers calibration certificate.
356 Supplying and erecting approved make panel 1.00 Ea. 1558.43
mounting type Digital Ammeter having 3 digits LED
display, external CT operated, calibrated for 0 to
Amps suitable to operate on 500 Volt AC , erected on
existing panel board with all connection, wiring etc
.with manufacturers calibration certificate.
switch for 3 phase AC Supply 500 V on existing panel
board with necessary connections.
358 Providing & erecting L.T. Current Transformer with 3.00 Ea. 274.72
bar primary 50/5 to 1000/5 ratio 15 VA burden
erected in existing CRCA box duly secured with
insulating materials connected to the meter
359 Supplying and erecting approved make suitable panel 9.00 Ea. 43.43
indicator LED type lamp, lens cover, complete erected
with necessary connections.
360 SITC of Vertical Air Termination Solid aluminium with 6.00 Ea. 9416.23
Base- 10 mm dia and 1000 mm long. Air Termination
Base tested for conditioning, Ageing Test & Lightning
impulse current withstand test: 100 kA of 10/350µs
waveform in an accredited Third party laboratory as
per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST
34mm dia 3000 mm long- Cold Galvanized
361 SITC of 8 mm dia solid Aluminium Conductor for roof 183.00 Mtr. 299.97
top mesh grid and tested as per IEC 62561-
conducted in the Govt. accredited thirty party
laboratory to meet the requirement of IS/IEC
with Required Accessories - Aluminium Holding clamp
at every 1 mtr distance, Aluminium/SS cross splicer at
every crossing of Alu. conductor, Expansion piece with
connectors at every 20 mtr distance, Aluminium
straight Splicer to connect conductors. All Accessories
should be tested as per IEC 62561-1 2018 Cl. 6.3 for
conditioning & Ageing Test & 6.4 for Lightning
impulse current withstand test: 100 kA of 10/350µs
waveform(Ageing & Electrical test ) conducted in a
sequence manner & tested in the Govt. accredited
Third party laboratory to meet the requirements of
IS/IEC
362 SITC of Galvanized Steel Flat 25x6 mm thickness from 88.00 Mtr. 154.53
earth electrode directly in ground as required. Zinc
coating: 500 g/m square (Approx:70 micron coating)
tested and used exclusively for lightning protection
earthing system and ring equipotential bonding.
363 SITC of 14.2 mm dia 3 mtr long Earth electrode of High 6.00 Per 5992.33
tensile steel electrode with 250 micron copper Set
bonding & 1 bag of Carbon fill Based environment
friendly backfill tested as per IEC 62561-7 in NABL
accredited Laboratory and suitable stainless Steel
double sided clamp. Eco Friendly rust proof heavy duty
weather proof Polyethylene Earth Pit Chamber with
following dimensions :254 mm dia (top), 330 mm dia
(bottom) & 260 mm (height).
364 Supplying, Erecting, Testing & Commissioning the 1.00 Ea. 1235286.56
passenger lift having following main features:
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High
Starting torque Lift 3 phase 440 V A. C. Permanent
Magnet Synchronous motor of proper rating with high
efficiency shall be used.[2] Micro processor based /
PLC, ACVVVF, vector control drive with encoder
feedback closed loop system shall be used for lift car
and door operation which shall be full collective
UP/DOWN hall stops, Main, Up/ Down Contactor with
overload and phase reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate
size and to sustain the impact load cabin + passenger
with safety factor of fire for steel and side panels of
Stainless steel of sheet of grade 304 duty. Car ceiling
will be S.S. finishes with aesthetic appearance with
LED ceiling lights. Car flooring shall be of s/s
chaker plate design sugeested of engineer in charge. of
engineer in charge. Car doors shall be of stainless steel
grade 304, hairline finish with centre opening /
telescopic automatic doors. Car panel will also be S.S.
304 finished with emergency stop device, mechanical
door safety device, facility of auto/ attended mode. All
car panel buttons and all floor switches must be with
brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour shall
be fully automatic centre opening/ telescopic opening
made of hairline finish steel grade of 304 with key
holes and infrared curtains with Unlocking facility
from outside
[5] Appropriate battery operated emergency light in
the car along with alarm switch shall be provided. Also,
Emergency Light & Fan should start immediately
without any Time Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down
arrow along with floor position indicator shall be
provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual Rescue
Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic
sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and
submission of calibration certificate submission, door
key holes in the floor doors, fireman switch shall be
[15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit should be
provided by the lift agency, along with the other steel
structure works, foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided
without any extra cost, where ever required as / if
directed by engineer in charge.
[17] Permanent wiring with necessary safety devices
like RCCB in all circuit, Over Voltage Under Voltage
protection and THD eliminator in circuit for lift
machine room and lift well with proper numbers of
light points, with fixtures, exhaust fan and plug points
shall be provided by the agency. Only 3 phase Power
Supply shall be made available by department in lift
machine room. Necessary Earthing as per Lift
Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and
alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without any
extra cost. (granite/marble fixing around all landing
door openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all
necessary permission from lift inspector and other
authorities. [20] acrylic transparent
licence/display A4 size holder in lift car
[20A] As per statutory requirement of Govt. Of Gujarat
lift & escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after
lift erection and provide report by third party
authorized by concern licensing authority 5.agency
has to provide third party insurance upto completion
of free maintenance period and submit the document
for the same.
[21] Car Panel Operating Buttons with floor position
indicator/buttons must be of Auto Glow type clearly
visible when view from inside cabin.
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should
be provided at appropriate height on the Rear & Side
Wall Panels in Lift Car. [23] With Necessary KVA
rating voltage controlled Stabilizer suitable for your
controller, drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required
for lift is in scope of work which rating is sugested by
CEICED Department (electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for
PREMIUM category
1. Advanced control system dual 64 bit embedded
microprocessor with CANBUS Serial Communication
mode including Regenerative power efficient
operation,on site programming facility, Anti nuisance,
Pte-opening, BMS/RMS with necessary online real
time monitoring system having necessary connectivity
for remote monitoring & other suitable supporting
hardware & software devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration &
brail mark with arrival gong and hall lantern & TFT
Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS Moonrock
finish / Hair Line / Honeycomb for car and all Doors,
All landing doors must have fire rating up to 2 hours
and car door must have multi-level crisscross beam
door protection.
4. To & fro communication system & wiring (i.e. car
control room & guard room ) and Each elevator are
equipped with remote monitoring system.agency has
to provide mobile app and user id and password for
monitoring
6 Passengers, Ground plus 2 upper floors with Rated
Speed of 1.0 m/sec. (C) With General PLUS
ADDITIONAL SPECIAL FEATURES attached herewith.
Prem. Cat.
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures and
words) of the estimated rate mentioned above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
1 The Credit Value of Dismentalled Materials of Amount Rs. 6,08,800.00 ( Main Building ) + Rs.97,296.00 (
Compound Wall ) = Rs.7,06,096.00 * shall be recovered from the 1st Running Bill of the Contractor . *(
Refer As per Special Condition atteched in SBD).
2 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-
In-Charge for which no extra payment shall be made.
3 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
4 Income tax TDS will be deducted at a source while making payments of bills
5 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-
10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where
there is a change as per actual mix design the cost of difference of cement consumption have been deducted
from the rate of original item at the rate of input rate mentioned in all the tender.
6 GST will be paid Extra as per Govt. amendment
Deputy Executive Engineer Executive Engineer
Dang (R&B) Sub Division Dang (R&B) Division
Ahwa Ahwa
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
0.0 SBD Sub Divisional Office Ahwa Dang (2 side).pdf
1.0 GRs - SBD with Index (2 side).pdf
1.2 Speical Condition Demolition.pdf
2 BOQ Sub Divisional Office Ahwa Dang (1 side).pdf
3 Item Wise Specification Sub Divisional Office Ahwa Dang (2 side).pdf
4 Building-Specification Booklet (2 side).pdf
Drawings.pdf
2.0 Special condion Electric.pdf
3.0 NOMINATED ELECTRICAL SUB CONTRACTORS.pdf
4.0 SBD Specification Electrical Work Compressed.pdf
5.0 General Specification for LIFT - Not in DTP.pdf
6.0 Lift-contract on stamp.pdf
7.0 ALL IN-SERVICE and MAINTANANCE.pdf
8.0 MOU Electrical Work.pdf
7. Revise Yearly Lift Maintanance and Clause.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].