Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.9 L+₹41,843.88 (1.95%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹26.0 L
EMD Value
₹51,940
Closing Date
14 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
REPAIR/MAINTENANCE OF HT DISTRIBUTION SYSTEM AND ALLIED WORKS AT NAA UNDER GE (N) TEZPUR
2023_MES_580841_1
CWE/TEZ(N)/T-49 of 22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(N) Tezpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(N) Tezpur
₹51,940
Yes
22 Mar 2023
14 Feb 2023
16 Mar 2023
14 Feb 2023
14 Mar 2023
28 Feb 2023
Amount
Dismantling and taking down existing unserviceable Gang operated switch complete including dropout fuse set from RCC / Steel tubular (Single/2 Pole/3 Pole/ 4 Pole) pole structures complete all as specified and directed.
Dismantling and taking down unserviceable Lightining arrestors complete all as specified and directed.
Dismantling and taking down rusted / corroded Cross arms any shape and size from PCC/ Steel Tubular Poles including nut bolts clamps complete all as specified and directed.
Dsmantling and taking down unserviceable stay assembly complete from PCC / Steel tubular poles complete all as specified and directed.
M&L for Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of two coats of Aluminium Paint over a Coat primer, complete all as specified and as directed.
M & L for Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted having 12 insulator and fitted on steel frame suitabe for, current rating 200 Amps, mechanically operated mechanism consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including Expulsion Fuse, Single Pole, Channel type/ drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps including taking down unservice-able Fuse , complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe /Cables etc complete all as specified.
Excavation in trenches not exceeding 1.5 Mtr wide and exceeding 1.5 Mtr depth up to 3 mtr in soft / loose soil and getting out for remonving / laying of pipe /Cables etc complete all as specified.
Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified and directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified and directed.
M&L for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed.
M&L for Boring / Drilling (Horizontally) manually / mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class HV, type - I, flat, size 300 x 180 x 40 mm all as specified and directed.
Dismantling and taking down unserviceable HT UG cable from pole or in trench all as specified and directed.( Note Excavation work will be measured and paid separately under respecive item of schedule.)
M&L Relaying of serviceable UG Cables of any size obtained from item No- 14 in trenches/poles/walls complete all as specified and directed. .NOTE : Earthworks, Sand Cushioning, PCC cable cover, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, PCC cable cover, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 120 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, PCC cable cover, GI Pipe, etc. will be measured and paid under appropriate Items.
Materials and labour for outdoor cable end termination joint cold shrink type suitable for 11 KV 95 sq mm 3 core HT XLPE 11000 volts heavy duty armoured cable complete all as specified and directed.
Materials and labour for indoor cable end termination joint cold shrink type suitable for 11 KV 95 sq mm 3 core HT XLPE 11000 volts heavy duty armoured cable complete all as specified and directed.
Materials and labour for outdoor cable end termination joint cold shrink type suitable for 11 KV 120 sq mm 3 core HT XLPE 11000 volts heavy duty armoured cable complete all as specified and directed.
Materials and labour for indoor cable end termination joint cold shrink type suitable for 11 KV120 sq mm 3 core HT XLPE 11000 volts heavy duty armoured cable complete all as specified and directed.
Materials and labour for outdoor cable straight through joint heat shrink type suitable for 11 KV 95 sq mm 3 core HT XLPE 11000 volts heavy duty armoured cable complete all as specified and directed.
Materials and labour for outdoor cable straight through joint heat shrink type suitable for 11 KV 120 sq mm 3 core HT XLPE 11000 volts heavy duty armoured cable complete all as specified and directed.
S&F of Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitablefor working pressure of 11000 Volts including earth strip , complete all as specified and directed.
M&L for Servicing and painting of 11 KV GOD by cleaning the contact ,Pin insulator with CTC and applying the Patrollium Jelley at the contact point /down rod links for smooth operation including replacing the rusted /corroded bolts and nuts(using GI Nuts& Bolts)and defective insulator of GOD as required at site. Painting shall be done by after preparing/scrapping the metal surface with emery sheet in all respect and painted with one coat of primer and two coat of aluminium paint including cross arm/MS channel and male female contact in red/yellow/blue colour Note:-Male/female contactors,copper jumper ,etc shall be measured and paid under relevant items
Supply only Male Contact/ moving contact blade of Air Break Switch 11 Kv complete all as specified and directed.
Supply only Female contact/ fixed contact Jaw of Air Break Switch 11 Kv complete all as specified and directed.
Dismantling and taking down of transformers of capacity 100 to 400 KVA outdoor,by disconnect HT & LT connections from plinth/ platform mounted and repair the PCC foundation and refixing of transformer including HT & LT connections all as specified and directed by Engineer-in-Charge Note:- (a) Required tools & plant including crane for lifting arrangement, shall be included in the rate quoted. (b) Any damage occurred during lifting/ transporting, the firm will be responsible to rectify such defect free of cost. (c) PCC and brick work shall be measured and paid seperately.
Materials and labour for replacement of silica gel of breather including providing silica gel as per the existing size / model complete all as specified and directed.
Supply & fixing GI Pipe light grade 80 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc complete all as specified and directed.
Materials and labour for Stay assy complete with accessories as shown in electric plate No.1 stay rod 20 mm including loop type insulator & stay clamp stay strands excavation & concrete measured seperately complete all as specified and directed.
Material and labour for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete for poles / stays complete all as specified and directed.
Material and Labour for Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate in cement mortar 1:4 for coping incl necessary formwork complete all as specified and directed.
Material and Labour for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in cement mortar 1:4 for coping incl necessary formwork complete all as specified and directed.
M & L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as 100 mm thick in sub floors and sub base floors and paving complete all as specified and directed.
Labour for restringing/tilting, clamping, bending, jumpering etc to remove excess sag of loose ACSR overhead line using essential T&P such as manila rope, puller and teipod etc upto permissible sag between two poles continuously upto termination point. Note- 1. Three runs of ACSR shall be measured as one unit. 2. Span Between two consecutive poles shall be measured as one unit upto 80 mtrs. 3. The cost of use of required tools and safety equipments is deemed to be included in this unit price.
Labour for trimming/cutting to small tree branches girth not exc 30cm upto minimum 2 Mtr clearance, tightening to stay stand in proper angle complete all as specified and directed by Engr in charge. Note- 1. Span Between two consecutive poles shall be measured as one unit upto 80 mtrs. 2. The cost of use of required tools and safety equipments is deemed to be included in this unit price.
Material and labour for painting to steel tubular pole 11.0 metre long with two coats of synthetic enamel silver up to below 1.5M from Top edge and 1.50 metre height from ground level in 30 cm alternative black and red strips and remaining portion with alluminium paint incl numbering of pole no by stensils and MS frames like channel,clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified and directed.
Supply and fix danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolt and nut approved size for HT poles, 25x25cm size including taking out old unserviceable danger notice plate complete all as specified and directed.
Materials and Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel strip 32 mm x 6mm by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete as specified and directed. Note: (i) Earth value should be less than 1 ohm. If sand found in the depth of 2.25 M during excavation fresh soil to be filled after removal of sand the cost shall be deemed be included the quoted rate. (ii) Earth test report shall be submitted by contractor duly signed.
M&L for GI strip 32x6 mm as earth continuity lead beyond test point fixed to wall on batten or recess or chases or buried in ground or drawn in conduit pipe complete all as specified and directed.
Supply and fixing Board Display / Notice Board (for display Standing order/Security order/Fire order/ Duty roster etc) of size 5Ft x 4Ft made out of 20 mm thick soft particle board and pasting velvet cloth on front and then binded with teak wood 40mm x 15 mm beat duly planned, finished and polished including necessary clamps for hanging arrangements on walls complete including dismantling of old perished board all as specified and as directed. Note- Standing order/Security order/Fire order/ Duty roster etc shall be supplied by the Dept free for fixing and necessary board pin/ colored ribbon etc for fixing deemed to be included in the item rate
Material and labour for Glow sign Board of size 5 feet x 4 feet x 8 inch size made out of PGI sheet (1 mm thick) on angle iron (25 x 6 mm) structure, detachable front cover with perplex sheet white in colour of 3mm thick, binded with angle aluminum, writing / pasting the ‘matter/subject’ given by the Engr – in- charge with self adhesive synthetic vinyl sticker blue in colour, including fixing inside 03 nos LED tube light fittings 1 x 20 watts patty type with one tube complete with all accessories prewired and all internal wiring and main connection with single core stranded copper conductor 1.5 sqmm size-10 RM including fixing arrangements with two extended legs of 50 mm dia GI medium grade pipe grouted in and including PCC(1:2:4) foundation of size 5 feet x 1 feet x 2 feet height (1 feet above GL) including thermoplastic cable junction box with two bus bar complete including dismantling of all perished board all as specified and fixing as directed.
Supply and fixing ‘Board display’ for electric supply installation including marking of lay out diagram of 33 KV MRS of size 5Ft x 4Ft made out of 3 mm thick perplex sheet( white in color) framed with teak wood beat 1” x I” on backside and angle aluminium ¾ size binding on front side duly screwed, incl suitable fixing arrangement for hanging on wall complete incl dismantling of old perished board all as specified and as directed.
S & F in repair cable route markers made out of PCC (1:3:6) type C1 using 20mm graded stone aggregate size 900 x 300 x 100 mm thick (60 cm buried in ground with "DANGER/11 KV UG CABLE MES" embossed on marker including excavation and earth work complete all as directed.
M&L Paint to existing HT bus bar chamber of any type complete with two coat of weather proof synthetic enamel paint after preperation of the surface by scrapping emery paper complete all as directed by Engr-in-Charge.
M&L for Boring / Drilling (Horizontally) manually / mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 80 mm bore complete all as specified and directed.
Supply, install, testing & commissioning of HT busbar chamber CPRI approved of size (0.90x0.90x0.75)m , outdoor type, 7 tank processed factory fabircated CRCA sheet powder coated of 3.15 mm thickness, powder coated indoor plates 2mm thick, angle iron of size 50X50X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete comprising of following :- BUS-BAR AND CABLE ENTRY (a)The bus-bars shall be made up of 03 Nos Aluminium 200 A rated not less than 32mmx6 mm, (b)The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.
Notes:- (i) Danger notice plate of size 25 x 20 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for HT conforming to IS-2551 - 02 Nos. (ii) Design / Drawing / BOM of the HT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. (iii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. (iv) The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. (v) The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
PURBANCHAL BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .