Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹34.0 L+₹1.0 L (3.05%)Rejected-Finance 695 NEAR ANJALI CLINIC SHIV PALACE SHANTI VIHAR BADAUN ROAD SUBHASH NAGAR BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L2 | Rejected-Finance Not being lowest tenderer | |
| 3 | L3₹36.3 L+₹3.3 L (9.92%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tenderer | |
| 4 | L4₹42.2 L+₹9.2 L (28.0%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
10 Jun 2023, 6:00 pmClosed
GE RANIKHET
GE (MES) RANIKHET
CERTAIN REPAIR TO PERIODICAL SERVICES INCLUDING WELCOME MAINT AND SEWAGE SYSTEM AREA DRAINAGE FENCING AND GATE AND MISC ITEMS AT HALDWANI KATHGODAM RANIBAGH AND KAMOLA UNDER GE RANIKHET
2023_MES_594650_1
GE/RKT/24 OF 2023-24
Open Tender
Civil Works
Item Rate
330 days
Haldwani, Ranibagh, Kamola, Kathgodam under GE Rkt
Class D, Cat a (i)
7 documents required · 7 mandatory
₹500
GE RANIKHET
₹96,000
19 Aug 2023
11 May 2023
19 Jun 2023
11 May 2023
10 Jun 2023
26 May 2023
Amount
BOQ ( Sch 'A') B/R items Cleaning of blocked / chocked sewer / sewage line of any description (SGSW / RCC / CI Pipe) of 100mm / 150mm / 200mm dia and any depth by rodding or by mechanical means and well flushing the complete sewer line from manhole to manhole or from cleaning eye to next manhole to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed.
Removing the existing manhole covers & cleaning of manhole of any description & size upto 1 metre in depth including lifting up and removing sludge & accumulated solid/semi solid sludge and any other foreign material with proper equipments & washing down with water for smooth functioning of sewage line all as directed incl disposal of sludge / containted works out side the defence area to a place designated for the same by the civil authrities for dumping of sludge / contement water after cleaning incl covers to be put back to its place complete all as specified and directed.
Removing the existing manhole covers & cleaning of manhole of any description & size exceeding 1metre and not exceeding 1.5metre in depth including lifting up and removing sludge & accumulated solid/semi solid sludge and any other foreign material with proper equipments & washing down with water for smooth functioning of sewage line all as directed incl disposal of sludge / containted works out side the defence area to a place designed for the same by the civil authrities for dumping of sludge / contement water after cleaning incl covers to be put back to its place complete all as specified and directed.
Removing the existing manhole covers & cleaning of manhole of any description & size exceeding 1.5 metre in depth including lifting up and removing sludge & accumulated solid/semi solid sludge and any other foreign material with proper equipments & washing down with water for smooth functioning of sewage line all as directed incl disposal of sludge / containted works out side the defence area to a place designed for the same by the civil authrities for dumping of sludge / contement water after cleaning including covers to be put back to its place complete all as specified and directed.
Removing the existing covers of septic tank & cleaning the same of any size / capacity by dewatering and taking out sludge in liquid, mud, silt or in solid state after emptying the water by manual or by mechanical means and removing the sludge complete all as specified and directed incl disposal of sludge / contained works out side the defence area to a place designated for the same by the civil authorities for dumping of sludge / contement water after cleaning including covers to be put back to its place complete all as specified and directed.
Removal of blockage from WC by using rubber cup 125mm dia with wooden handle and clearing the blockage up to 1st manhole with cleaning rod including removal of all materials from P trap of WC and dispossing off complete all as specified and directed.
Removal of blockage from traps of kitchen/bathroom/WHB by using rubber cup 125mm dia and clearing the blockage up to gully traps with cleaning rod including removal of all materials from floor trap and disposing off complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and disposal of unserviceable materials, debris and rubish to a distance not exc 50m as directed by Engr-in-Charge complete all as specified.
Material & Labour for precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:6 including necessary form work complete all as specified and directed. (Note:- reinforcement to be measured separately)
Material & Labour for reinforced cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate)., as in Slab supported on walls,beams and columns in floors,roof, landing, balconies,complete all as specified & directed. (Note:- reinforcement to be measured separately)
S & F mild steel reinforcement TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, for fair finished flat surfaces of concrete complete all as specified and directed.
Demolition of brick work/stone or boulder/ PCC block masonery built in cement or cement lime mortar and disposal of old materials, debris and rubish from site complete all as specified and directed.
Material & Labour for bricks work with sub class 'B' bricks using old size brick straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
All as per item No 14 above but except bricks complete all as specified and directed. (Note:- Old seviceable bricks retreived from item No 13 shall be reused)
Material & Labour for bricks work with sub class 'B' bricks using old size brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
All as per item No 16 above but except bricks complete all as specified and directed. (Note:- Old seviceable bricks retreived from item No 13 shall be reused)
Demolition of cement concrete ( unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) and disposal of unserviceable materials, debris and rubish to a distance not exc 50m as directed by Engr-in-Charge complete all as specified.
Material & Labour for PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Material & Labour for PCC 1:3:6 ,type C1 (using 20mm graded stone aggregate as in copings, bed plates etc including necessary form work complete all as specified and directed.
Excavation in trenches not exc. 1.50m wide and not exc. 1.50m in depth for foundation etc or for manholes cesspits, shafts etc not exc 10 sqm on plan and getting out in hard / dense soil complete all as specified and directed.
All as per item No 21 above but exc 1.50m in depth and not exc 3.00m in depth
Removing excavated soil to a distance n.exc 50m where directed at a level n.exc 1.50m above the starting point complete all as specified and directed.
Returning, filling in, including spreading , levelling, watering and well ramming in layers not exc 25 cm thick in hard/dense soil complete all as specified and directed.
Demolition and breaking up drain pipes (SGSW, AC or RCC) of internal dia 150mm, set in cement mortar complete all as specified and directed.
Material & Labour for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
Material and labour for unplasticised PVC pipe 160mm dia type 'B' with wall thickness 4mm (Min) of pressure rating 4 KN/Sqm laid in trenches and jointed with cement solvent including testing complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 finished even and smooth and reforming benching as required, for internal dia of pipe 150mm/160mm complete all as specified and directed.
Dismantling of CI pipe 100mm dia jointed in cement mortar and taking out of trench if required complete all as specified.
Dismantling of CI pipe 75mm dia jointed in cement mortar and taking out of trench if required complete all as specified and directed.
Supply & Fixing cast iron spun pipe 100mm dia for soil, waste or vent pipe in any lengths with or without ears, jointed with and including cement joints fixed to walls including necessary clamps etc complete all as specified and as directed.
Supply & Fixing cast iron spun pipe 100mm dia for soil, waste or vent pipe in any lengths with or without ears, jointed with and including cement joints laid in trenches or in floor complete all as specified and as directed.
Supply & Fixing cast iron spun pipe 75mm dia for soil, waste or vent pipe in any lengths with or without ears, jointed with and including cement joints fixed to walls including necessary clamps etc., complete all as specified and as directed.
Supply & Fixing cast iron spun pipe 75mm dia for soil, waste or vent pipe in any lengths with or without ears, jointed with and including cement joints laid in trenches or in floor complete all as specified and as directed.
Supply & Fixing CI spun branch piece 100mm bore, double(equal or unequal), with parallel branches and fitted with oval access door complete all as specified and directed.
Supply & Fixing CI spun branch piece 75mm bore, single (equal or unequal), ordinary or inverted spigot or socketed type with parallel branches and fitted with oval access door complete all as specified and as directed.
Supply & Fixing in repairs CI floor trap of size 75mm with grating including jointing to CI pipe with lead joint including making joint water tight complete all as specified and directed.
Supply & Fixing CI spun bends 100mm bore of any radius, diminishing piece or tappers complete all as specified and as directed.
Supply & Fixing CI spun bends 75mm bore of any radius, diminishing piece or tappers complete all as specified and as directed.
Supply & Fixing CI spun vent cowl for 75mm bore pipe complete all as specified and directed.
Material & Labour for extra over cast iron pipes and fittings if lead joint is provided in lieu of cement joint for 75mm bore pipe complete all as specified and directed.
Material & Labour for extra over cast iron pipes and fittings if lead joint is provided in lieu of cement joint for 100mm bore pipe complete all as specified and directed.
Supply & fixing in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed with and including necessary fittings like socket, bend, elbow, single/double tee etc in any length with rubber ring joints fixed with clamps of flat iron and including bolts and nuts and securing ends of stays to wall or roof and making good with cement mortor 1:3 or with PCC 1:2:4 including finishing to match with existing surface complete all as specified and directed.
Supply & Fixing in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed with and including necessary fittings like socket, bend, elbow, single/double tee etc in any length with rubber ring joints fixed with clamps of flat iron and including bolts and nuts and securing ends of stays to wall or roof and making good with cement mortor 1:3 or with PCC 1:2:4 including finishing to match with existing surface complete all as directed.
Supply & Fixing in repair PVC ( SWR) 110 mm bore bends for any radius complete all as specified and directed.
Supply & Fixing in repair PVC ( SWR) 75 mm bore bends for any radius complete all as specified and directed.
Supply & Fixing in repair PVC (SWR) junction single, (Single T) equal or unequal in 110 mm bore complete all as specified and directed.
Supply & Fixing in repairs for PVC (SWR) floor/Nahani trap 75 mm dia outlet, plain with grating including jointing with solvent cement to waste pipe, fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or PCC blocks or stone wall or concrete surface etc, including raking out joints, hacking for keys, scrubbing down with water etc including taking out / removal of all the tree roots from the brick / concrete surface and removing rubbish to a dostance not exc 50 m complete all as specified and directed. ( Note ;- Rate quoted by the contactor shall deemed to included this aspect and nothing extra shall be paid on this account )
Material & Labour for rendering 15mm thick in cm 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply & Fixing in repairs vitreous China squatting pan, Orissa pattern, size 580 x 440 mm white, with integral foot rests squatt pattern closet also includes setting the CI trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggregate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing (thickness as indicated) and making good floor to match with existing surface including cutting to the flush pipe and necessary repair to the floor complete all as specified and directed.
Material & labour for Non skid ceramic tiles 7 to 8mm thick coloured ( square/rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile over with and including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and directed.
Supply & Fixing Vitreous china wash down water closet pan (padestal pattern), white(excluding fixing bolts, flushing cistern and flush pipe) including connection to flush pipe and drainage pipe including CP jet complete all as specified and directed.
Cleaning and removing all scale, green algae and dirt, etc from water tanks and from mouths of circulating pipes, etc by brushing with iron brushes, using bleaching powder, capacity of tank n exc 250 litre including writting date of cleaning with synthetic enamel paint complete all as specified and directed.
Cleaning and removing all scale, green algae and dirt, etc from water tanks and from mouths of circulating pipes, etc by brushing with iron brushes, using bleaching powder, capacity of tank exc 250 litre & n exc 500 litre including writting date of cleaning with synthetic enamel paint complete all as specified and directed.
Cleaning and removing all scale, green algae and dirt, etc from water tanks and from mouths of circulating pipes, etc by brushing with iron brushes and using bleaching powder, capacity of tank exc 500 litre & n exc 1000 litre including writting date of cleaning with synthetic enamel paint complete all as specified and directed.
Supply and fixing 20 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms). complete all as specified .
Supply and fixing 25 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 25mm-455gms). complete all as specified .
Complete removal of existing treatment on wall(Internal/External) /roof projections including facis, cornics etc(Internal surfaces by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc) & (External surface by Jet washer) by skilled labour complete all as specified and directed. Makes :- Nerolac -Excel, Asian - Apex, Berger - Weather coat antidust, Dulux - Weather shield.
M & L for providing and applying minimum 1mm thick wall care putty over prepared surface and rubbing it with mechanical sander (having mechanical vaccum mechanism) to achive the surface even and smooth for further application of finishes complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over any surfaces.
M & L for applying Two or more coats of Acrylic Interior Emulsion paint, of approved manufacturer, of required shade and colour over a coat primer complete, as per manufacturer's specification complete all as specified and directed. Makes: Nerolac-Little Master(Beauty), Berger-Bison Lite, Asian- Tractor emulsion spark. Note- 1. Application of Primer and distemper to be carried out through Roller (Mechanical means) 2. Wall care putty (if required at site before application of above painting in certain portion ) shall be done and same shall be measured and paid seperately under serial item No 60 above
M&L for applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer over a coat of primer, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed. Note- 1. Application of Primer and distemper to be carried out through Roller (Mechanical means) 2. Wall care putty (if required at site before application of above painting in certain portion ) shall be done and same shall be measured and paid seperately under serial item No 60 above
M&L for one coat of synthetic enamel paint incl preparation of old concrete surfaces plain or moulded, over 10 cm width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed.
M&L for one coat of white wash on old decorated surfaces of wall including preparation of surfaces by brooming down or steel, wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and directed.
All as per item No 65 above but on ceiling, soffits of chajjas/balcony etc
M&L for one coat of colour wash with using mineral colour on old decorated surface of external wall including preparation of surfaces by brooming down on steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and directed.
All as per item ser No-67 above but applying two coats of colour wash complete all as specified and directed.
M&L for preparation of old decorated plastered or unplasteredsurfaces of walls including cornices etc by brooming down stell wire brushing, scraping down smoke soot, moulds, masss and efflorscent salts and trading oil and greasy spots & removing of nails mark & applying one coat of cement base paint on wall complete all as specified and directed.
M&L for complete removal of existing surface and applying two coat of cement base paint on old decorated/undecorated surfaces of walls complete all as specified and directed.
M&L for applying one coat of oil bound distemper to old decorated surface of wall including preparation of surfaces complete all as specified and directed.
M&L for complete removal of existing surface and applying two coats of oil bound distemper white or tinted on old decorated/undecorated surfaces of wall complete all as specified and directed.
M&L for applying one coat of oil bound distemper to old decorated surface of ceiling to match the existing surface including preparation of surfaces complete all as specified and as directed,
M&L for one coat of synthetic enamel paint to old decorated wooden surfaces over 10cm width or girth including preparation of surface complete all as specified and directed.
M&L for one coat of synthetic enamel paint to old decorated steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and directed.
All as per item No 75 above but n.exc 10 cm width or girth complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:3) on fair faces or concrete ceiling surfaces finished even and fair without using extra cement complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion, over a coat of primer on wall complete all as specified and as directed
Preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer on wall complete all as specified and directed.
M&L Writing letters or figures (Block Roman, Italic or Indian) n exc. 30 cm high incl preparation of surface and making the base to receive letters by applying synthetic enamel paint. Letters etc shall be paint with thick paint
M & L for preparation of old painted steel and iron CGI/PGI sheet roof of any description not otherwise described over 10cm width or girth and applying one coat of roof paint (Coptic of Jenson and Nicholson or Anisole of Berger or equivelent of other make as approved by GE ) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using (20 mm graded stone aggregates) as surface channels and drains complete all as specified and directed.
Material & Labour for PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate as in copings, bed plates etc including necessary form work complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground
M&L Hand rails, half round or other stock section hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters nosing to steps incl embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing incl cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets incl all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 .
S & F round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips.
Dismantling fencing wire mesh, any type complete all as specified and directed
Supply and fixing chain link fencing, 4mm dia galvanised steel wire, 50x50mm mesh made up into mattresses or cages lapped wired and fixed in position including fixing to any type of posts, standards, rails, straining bolts, etc including provn of binding wire complete all as specified & directed.
Supply and fixing chain link fencing, 4mm dia galvanised steel wire, 75x75mm mesh made up into mattresses or cages lapped wired and fixed in position including fixing to any type of posts, standards, rails, straining bolts, etc including provn of binding wire complete all as specified & directed.
S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (Note: Each line wire to be measured)
Preparing new steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished surfaces of concrete complete all as specified and directed
M&L RCC 1:2:4 (using 20mm garded stone agg) as in foundation, including rafts, footings, foundation beams, plinth beams; bases for columns, etc., basement slabs, under reamed piles and mass concrete,complete all as specified and directed
Use and waste of formwork to the sides of pillars, posts, streads, piers, columns for fair finished surfaces of concrete complete all as specified and directed.
M&L RCC 1:2:4 (using 20mm garded stone agg) as in column, pillars, piers, posts and structs etc. complete all as specified and directed
Mild steel TMT bar 5mm dia and over upto 10mm dia as in stirrups, spacers and binders cut to length bent to shape required, including cranking, binding spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia for securing with clips complete all as specified and directed
S&F Mild Steel framed work and hung as gates including pintel hinges, stops, hand made sliding bolts, hold fasts etc. conforming to Fe 290.Gde E-165 complete all as specified and directed
M&L for wall cladding digitel coloured tile, area of each tile not exceeding 0.18 sqm, in verticle surfaces, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with backcoat of screed bed or bedding layer 15mm thick 1:4 and pointed in white or coloured cement to match complete all as specified and directed
SURYA CONSTRUCTION
Shri Varada Enterprises
KRISHNA SAI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .