Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 1076 BEHERA SAHI NAYAPALLI BHUBANESWAR 751012 | KHORDHA | ODISHA | 751012 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance FLAT NO 102 BLOCK C 1ST FLOOR DHPL SAHOO RESIDENCY GADAKANA MANCHESWAR BHUBANESWAR KHORDA ODISHA 751017 | KHORDHA | ODISHA | 751017 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.4 L
EMD Value
₹4,811
Closing Date
7 Jun 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director, NISER
NISER Bhubaneswar, Jatni
Provision for Additional power point fixing and wiring in the Lab no. 313 and Earthing installation with UPS wiring in Lab no. 305 of SPS building
2021_NISER_631028_1
NISER/IWD-ELE/SPS/2021-21/07
Open Tender
Electrical Works
Works
30 days
NISER Bhubaneswar, Jatni
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹4,811
Yes
8 Jun 2021
25 May 2021
8 Jun 2021
25 May 2021
7 Jun 2021
28 May 2021
90 days
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 6 way (4 + 18), Double door Make: Legrand/Hager/Schnieder
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp MCB Isolator, Make: Legrand/Hager/Schnieder
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp RCCB, Make: Legrand/Hager/Schnieder
Supplying and fixing 10A and 16 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SP MCB, “C” curve, 10 kA breaking capacity. Make: Legrand/Hager/Schnieder
Supplying and fixing of 6 Module modular PVC surface box with 2nos. of 5/15A socket out let and 2 nos. of 15amp Modular switch including installation, fixing of switch and socket and connection.) Make: Legrand (Mylinc/Myrius) or Equivalent
Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 32A 415 V "C" curve TPN MCB complete with connections, testing and commissioning etc. as required. Make: Legrand/Hager/Schnieder
Supply, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required with double run 10 SWG GI wire. 3.5Cx25 Sq MM AL Armoured XLPE Cable Make: Polycab/RR Kabel/Havells/ Universal
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X 25 sq. mm Cable
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Make: Polycab/RR Kabel/Havells/ Universal
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Make: Polycab/RR Kabel/Havells/ Universal
Supplying and fixing 4pole double door TPN sheet steel enclosure on surface/ recess along with 63A 240 V "C" curve 4P MCB complete with connections, testing and commissioning etc. as required. Make: Legrand/Hager/Schnieder
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Make: Polycab/Universal/RR/Havells
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke, soft soil and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip with Rhobust pvc sleev for earthstrip protection, on surface or in recess for connections etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
M/S TATHAGATA ENGINEERING
NAMAH SHIVAYA ENTERPRISE
SHIVAM POWER ELECTRICALS AND CONSULTANCY
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .