Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹42.3 L+₹5.4 L (14.6%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L2 | Rejected-Finance Rejected due to L2 | |
| 3 | L3₹44.1 L+₹7.2 L (19.6%)Rejected-Finance FIRST B ROAD SARDARPURA NEAR HANUMAN MANDIR JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Rejected due to L3 | |
| 4 | L4₹46.5 L+₹9.6 L (25.9%)Rejected-Finance | L4 | Rejected-Finance Rejected due to L4 |
Tender Value
₹46.6 L
EMD Value
₹93,172
Closing Date
9 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (Army) No 2 Jodhpur
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (ARMY) NO 2, MULTAN LINES, JODHPUR - 342010
EXECUTION OF CERTAIN SANCTIONED WORK UNDER GE (ARMY) NO 2 JODHPUR
2023_MES_622232_1
8800/23-24/56/13/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer (Army) No 2 Jodhpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (Army) No 2
₹93,172
Yes
3 Jan 2024
7 Oct 2023
11 Nov 2023
7 Oct 2023
9 Nov 2023
21 Oct 2023
Amount
Demolition of stone/ brick work masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stone work, serviceable stone aside for reuse and removing unserviceable material in low laying area complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for (such as copings, bands of any type, roof padding, kerbs, sunken etc; overall thickness and removing the dust debris etc to a distance out side MOD land from site and disposing the same complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L PCC (1:4:8) type D2 (40 mm graded aggregate) in foundation filling and mass concrete etc complete etc. complete all as specified and as directed.
Demolition of stone/ brick work masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stone work, serviceable stone aside for reuse and removing unserviceable material in low laying area complete all as specified and as directed.
M&L for squared rubble walling jodhpur type, brought upto course,well bonded bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and as directed.
-ditto- all as per above item but, except stone complete all as specified and as directed.
Extra over stone walling for hammer dressing upto 20 mm to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and as directed.
M&L for brickwork with fly ash bricks (old size bricks), straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and as directed.
M&L for providing PCC block masonary (1:3:6) with solid blocks exc 10cm in width and setting in cement mortar (1:6) complete all as specified and as directed.
M&L for 10 cm thick Sand stone slabs in sun-shades, chajjas,shelves, cills, landings, cover stones, pemplates, etc. n exc. 2m in length, punched dressed on face and along exposed edges,self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified and as directed.
M&L Jodhpur stone roof slabs, self faced exceeding 10cm but not exceeding 12.5 cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in cement mortar (1:3) complete all as specified and as directed.
M&L for carrying out water proofing treatment for roofs in the following stages - (i) PCC (1:2:4) type B0 25 mm thick using 12.5mm graded stone aggregates as in sub base floors roof paddding as in levelling course (ii) Rendering 10mm thick in 1:4 mixed with integral water proofing liquid all as per manufacturer's instructions over concrete surfaces finished even and smooth with out using extra cement. (iii) First coat of bitumen primer confirming to IS 3384 @0.300 Kg/ Sqm over plastered surafces (vi) Second layer of 3.0 mm thick APP modified polymeric membrane with centre core of Single non woven polyster reinforcement and having weight 3 Kg/ Sqm with mineral gravel finish on top complete laid with blown type bitumen grade 85/25 @ 1.20 Kg/ Sqm (v) Finally applying two protective coats of bituminous aluminium based reflective paint to safeguard against UV, including preparing surfaces (second coat apply after 24 hrs or as per manufacturing instructions).
Demolition of cement concrete (unreinforced) in ground floor not exceeding 15cm thickness below or above ground level including floor finishes and removing debris from the site complete all as specified and as directed.
Dismantling glazed tiles/ kota stone/ terrazzo tiles any type as in dado/ skirting etc; including cement mortar bedding ( but not backing ) complete all as specified and as directed.
Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) as in skirting / dado, Cut out of ceramic tiles of size exceeding 0.11 sqm but not exceeding 0.38 sqm, (Matching with floor tile of the same room) set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM (1:4) complete all as specified and as directed.
M&L for non skid ceramic coloured tiles of approved shade and pattern, 7 to 8 mm thick , area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm laid in floor, set and jointe (square/ rectangular) in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of approved shade and pattern of size 450X350X7mm to 8mm thick or any other nearer size as approved in vertical surface set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM (1:4) as in backing coat of tiles complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 18-20 mm (+ 2mm) thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 15mm thick screed bed or bedding layer in CM (1:4) complete all as specified and as directed.
M&L for mirror polished machine cut Kota stone slab 15-16 mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 and jointed complete all as specified and as directed.
M&L for 16-18mm thick granite (black colour) work (table rubbed and polished) in steps, shelves, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
M&L for Jodhpur stone slab patti machine cut, 40 to 50mm thick set in over and including 15mm thick cm (1:4) and jointed & pointed in neat cement slurry as in floors, plinth protection, including provision of construction joints as required etc complete all as specified and directed.
Excavation in Post holes each , not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm , watering, and removing surplus soil to a dist n. exc 50 m and making good surface in any type of soil complete all as specified and as directed.
M&L, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 incl painting one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed.
M&L for pre painted galvatume aluminium zinc GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering fixed with J or L hooks complete all as specified and as directed.
Surface excavation n.exc 30 cm deep & averaging 15 cm deep getting out in soft/ loose soil complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2, (40mm graded stone aggregate) as in sub floor, sub bases, floor and paving etc complete all as specified and as directed.
M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
M&L for 60mm thick factory made pre cast cement concrete rubber moulded laquer finish using chemical and admixure inter locking tiles having compressive strength not less than 350 kg/Sqcm, of shape and colour as approved by GE , laid over 25mm thick compacted approved sand cushioned surface, joints filled by fine sand and compacting the top surfaces complete all as specified and as directed.
M&L for factory made precast cement concrete solid blocks M-30 Grade, using 20 mm graded crushed stone aggregate as in kerb stones of any size (with plain or interlocking joints as directed) set in cement mortar 1:4 for path edgings etc; embedded in position including all necessary excavation, tamping ground arround blocks and removal of rubbish/ surplus soil etc complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified and as directed.
M&L for Jodhpur stone slab patti machine cut, 40 to 50mm thick set in over and including 15mm thick cm 1:4 and jointed & pointed in neat cement slurry as in walls, Chajja complete all as specified and directed.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and as directed
M&L for rendering 15 mm thick in CM 1:6 over stone masonary, concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for 15 mm thick rendering on stone masonary wall surfaces in CM 1:4 finished fair and even complete all as specified and as directed.
M&L for dubbing out average 20mm thick in cement plaster 1:4 on uneven/ irregular surface such as walls / ceilling / chajjas etc complete all as specified and as directed.
Rough cast plaster 15mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and rough without using extra cement complete all as specified and as directed.
M&L for 10mm thick rendering in CM (1:3) on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for carrying out water proofing treatment for sunken portion in the following stages - (i) Taking down of existing sunken slab treatment from the sunken portion and cleaning the surfaces washing down with water and rubbish of the pemises , cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00kg/sqm and grouting 25mm thick cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate on sunken slab portion and finishing the top surfaces even and smooth without using extra cement. (ii) M&L for two coat of acrylic cementitious water proofing coating (Dr FIXITpidifin 2k manufactured by M/s Pidilite Industries Ltd or equivalent) and followed by a overlay protective screed (10mm thick cement mortar (1:4) along with liquid water proofing compound approved make as per manufacturer's instructions) on top surfaces of sunken slab after preprations as mentioned above. Method of application for acrylic cementitious water proofing coating achieved as per manufacturers instruction complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4.00 sqm each and removing from site or to store complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing from site or to store complete all as specified and as directed.
Cutting holes in brick walls built in cement or cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required depth of embedded portion of hold fast exceeding half brick but not exc one brick complete all as specified and as directed.
Pressed steel framed made out of 1.25mm thick MS sheet, of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including PCC (1:3:6) type C-1 as in fillings and mass concrete, filling backs of chowkats complete all as specified and directed.
Ditto as per item no 45 but of size 105x60mm
Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in lintels upto 1.50 m clear span, cills , steps, seismic and other similar bands, copings, kneelars, apex stones, bed plates, bed blocks of hold fasts etc including necessary form work complete all as specified and as directed.
S&F of factory made 35 mm thick Plain framed, panelled shutters (two panel) with 2nd class hard wood rail and style with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified.
S&F of factory made 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified.
S&F of factory made steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skeleton shutter jointed internally with flat iron 40x4mm complete including grill of 8/10mm square bars as directed by Engineer incharge, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. (with provision of fixing for cooler if required) all as shown on drawing No CEJZ/TD/20 sheet 1/3 to 3/3 fixed in repairs i.e, incl taking down and removal of old steel windows from site or to store complete all as specified and directed. Note:- Guard bar/ grill shall be measured and paid separately under respective item of Sch 'A'.
M&L for fabrication of aluminium powder coated ventilators (with louvered) fabricated with anodized aluminium rectangular section in frame & with deco grill of approved design & stainless steel wire cloth on the outer side of frame & trade pattern louvers with suitable mechanism for tilting /opening closing etc all as per sample kept in GE office & fixed in position complete all as specified and as directed. (Note : Glass pane in louvers & stainless steel wire cloth shall be measured & paid separately)
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & as directed.
S&F Sheet glass ordinary quality 4 mm thick and glazing with oil putty or fixed with wooden beads or fixed with rubber gasket in squares any size of pane complete all as specified & as directed.
.-Ditto- all as per above item no 54 but 4 mm thick frosted glass complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
Mild steel round bars welded to steel windows or ventilators as in guard bars framed or unframed complete all as specified & as directed by Engineer incharge. Note :- Guard bars shall be factory welded & given one shop coat of red oxide or zinc chromate primer. Cost of factory welding & Shop coat of primer is deemed to be included in quoted rates.
S&F of Factory Made Solid PVC Moulded Door Shutter made out of with particle board core , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, fix in frame at site as per specification & drawing complete all as specified and as directed.
S&F of solid PVC door frame of size 50mm x 47mm made out of 5.0 mm single side prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S & F 100 mm size PVC/ Stainless Steel (as approved by Engineer incharge) butt hinges all as specified and directed.
S&F mild steel door handles, stove enameled black, 150 mm long and fixed with steel screws complete all as specified and as directed.
Mild steel barrel tower bolts, stove enameled black, with bright bolt, 150 mm long and fixed with steel screws complete all as specified and as directed.
300 mm long mild steel, sliding door bolt, plate type, stove enameled black, with bright bolt not less than 12 mm dia with and including bolts and nuts complete all as specified.
S&F Mild steel rat tail rod pattern helical door spring of size 300mm including roller and roller plate fixing to iron frame by welding complete all as specified & as directed.
Dismantling wrought iron or mild steel work of any description and in any position not otherwise specifically provided for (framed/ unframed work) complete all as specified and as directed.
S&F rolled mild steel framed work any type/ size or description joist/ girder with gusset plates, rails, braces,cooler stand, chajja framed, frame for water storage tanks, complete drilled for fixing of door etc; to be prepared for hanging with and including hold fasts and locking arrangements confirming to FE- 410-W(Gde-E- 250) complete all as specified and as directed.
Decorative mild steel curtain rods 32mm dia (powder/PVC coated) including fixing brackets & side cups complete fixed in repairs i.e., including taking down the existing unserviceable curtain rods complete all as specified and directed
S&F Powder coated aluminium anodised deco grill weighing not less than 1.40 kg/ sqm and fixing necessary joining cleats/ frame etc; complete all as specified.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed.
Dismantling cast iron work of any description and in any position complete all as specified.
S&F 100mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, laid in trenches or in floor etc complete all as specified and as directed.
Fixing only in repair 100mm bore any type of soil, waste and vent pipes in any length with or without ears, laid in trenches or in floor etc complete all as specified and as directed.
S&F 100mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, fixed to walls etc complete all as specified and as directed.
Fixing only in repair 100mm bore any type of soil, waste and vent pipes in any length with or without ears, fixed to walls etc complete all as specified and as directed.
S&F 75mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, laid in trenches or in floor etc complete all as specified and as directed.
Fixing only in repair 75mm bore any type of soil, waste and vent pipes in any length with or without ears, laid in trenches or in floor etc complete all as specified and as directed.
S&F 75mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, fixed to walls etc complete all as specified and as directed.
Fixing only in repair 75mm bore any type of soil, waste and vent pipes in any length with or without ears, fixed to walls etc complete all as specified and as directed.
S&F 100mm bore pipe cast iron 'P' or 'S' trap, complete all as specified.
S&F 75mm bore pipe cast iron 'P' or 'S' trap, complete all as specified.
S&F 100mm bore pipe cast iron cowls, complete all as specified.
S&F 75mm bore pipe cast iron cowls, complete all as specified.
M&L cast iron up to 150mm bore fittings of Bends (any type, radious and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces, single branch, 'Y' junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc complete all as specified and as directed.
M&L 100mm bore cast iron pipes and fittings joints or connections are filled/ sealed properly by epoxy sealant of ISI mark or M-Seal (Make:- Dr Fixit) apply as per manufacturing instructions, complete all as specified and as directed.
M&L 75mm bore cast iron pipes and fittings joints or connections are filled/ sealed properly by epoxy sealant of ISI mark or M-Seal (Make:- Dr Fixit) apply as per manufacturing instructions, complete all as specified and as directed.
S&F for 100mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc complete all as specified and as directed.
S&F for 75mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc complete all as specified and as directed.
Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specified and as directed.
Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specified and as directed.
Taking down 25mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specified and as directed.
S&F 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and as directed.
S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and as directed.
S&F 25mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and as directed.
Fixing only 15mm bore steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and as directed.
Fixing only 20mm bore steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and as directed.
Fixing only 25mm bore steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and as directed.
M&L vitreous china wash down water closet pan (pedestal pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet with 1.00 to 1.50m long tube (Make of Jet 'Praayag' Cat Part No 5211 or Equivalent) incl making connection to inlet flush pipe, & to 'P' or 'S' drain trap, incl supply of long special 'P' or 'S' trap fixed in repair complete and making good the disturbed portion etc. all as specified and directed.
S&F for Vitreous china squatting pan, Orissa pattern, size 580x440mm white/ coloured with integral foot rests including flus pipe and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified.
S&F for PVC 10 ltr. Cap. valveless syphonic action type, flushing cictern, low level, white/ coloured with inlet, ball valve, float and handle including brackets and connection to pipe etc complete all as specified and as directed.
S&F for Vitreous china wash basin, white/ coloured, flat back, size 550x400mm including PTMT waste fittings, 32mm bore size, waste pipe pvc 32mm bore and angle iron brackets of required size and length, pillar tap, brass, 15mm dia, with capston heads, chromium plated, fancy type . and making good disturbed surfaces to match with the existing complete all as specified and as directed.
S&F Steel Sink (Kitchen or Laboratory sink) made of Stainless steel 1.00mm thick with plugs, washers and PVC waste pipe & CP Waste 40mm/ 32mm size as approved including bedding in cement mortar/ chemical on to dwarf walls or including fixing vertical white marble 18-20mm thick (not exceeding 1.2 sqm each piece) and connecting union to pipe overall size 1040 x 510 x 203mm with bowl size 510 x 410 x 203mm with drainage board Cat Part No 1244-D Make 'Prayag' or Equivalent, fixed in repair incl removal of old unserviceable sink of any description & size complete all as specified and as directed.
Low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm, 450 mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe as in repair complete all as specified and as directed.
Disconnecting existing PVC tank exc 250 Ltrs and not exc 500 Ltrs setting aside (or lowering if required) for repairs. Cleaning, etc and hoisting if required reconnecting refixing in position complete all as specified and directed.
S&F in repair 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) tripal-layer in white colur hoisted and fixed in position including 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified and as directed.
S&F in repair 15mm bore chromium plated Bib taps, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Supply and fix in repair for Pillar tap, brass, 15mm dia, with capston heads, chromium plated, fancy type screwed down, high pressure, with or without lettered hot or cold, with long shank, screwed shanks and fly nuts, screwed for iron pipes or for wash hand basin complete all as specified and as directed.
S&F in repair 15mm bore stop valve/ angle stop cock chromium plated, fancy type cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe with long shank and cup complete all as specified and as directed.
S&F in repair 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F in repair Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union suitable for 15mm bore pipe etc; complete all as specified.
S&F in repair CP towel rail 450mm long fixed with and including CP brass screws and wooden/ plastic cleats complete all as specified and as directed.
S&F in repair CP greating doom 100mm dia complete all as specified.
Supply and fixing 25mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight for 25mm ball valves-455gms) fixed in repairs i.e., incl taking down and removal of old unserviceable float valves complete all as specified and as directed.
S&F in repair PVC SWR type 'B' socketed rain water pipes 110mm dia conforming to IS: 4985/ IS: 13592 complete all as specified and as directed.
S&F in repair PVC SWR bend/shoe of PVC 110mm dia suitable for 110 mm bore / dia PVC SWR rain water pipes complete all as specified and as directed.
Preparing new or previously untreated surfaces of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
Preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cm and applying two coats of synthetic enamel paint complete all as specified and as directed.
Preparing new plastered surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and two coats of Distemper oil Emulsion on new plastered surfaces complete all as specified and as directed.
Preparing new plastered surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and two coats of cement base paint on new plastered surfaces complete all as specified and as directed.
Preparing new plastered surfaces incl preparing the surfaces smooth by rubbing and / or sandpapering and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
Preparation of new plastered surfaces of walls etc. & applying three coats of lime white wash on walls complete all as specified and as directed.
Preparation of new plastered surfaces of ceiling etc. & applying three coats of lime white wash on ceiling complete all as specified and as directed.
Supply and Laying into trenches of Reinforced concrete pipes, class NP3, of dia 300mm laid and jointed complete with collars complete all as specified and as directed.
Suuply and laying of Bends of size 300 mm , laid and jointed complete all as specified and as directed.
Cutting into existing manholes for connecting new drains of size 225 mm internal dia , making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
Returning,filling in,including spreading,levelling,watering and well ramming in layers not exc 25 cm each layer in hard/dense soil complete all as specified and as directed.
Removing excavated soil n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed.
Preparing old plastered surfaces brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of distempered or painted surfaces and M&L for applying one coat of distemper oil emulsion on old plastered/ unplastered surfaces of walls complete all as specified and directed by Engr-in-Charge.
Preparing new plastered surfaces incl preparing the surfaces smooth by rubbing and / or sandpapering and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
Preparation of old decorated plastered/ unplastered surfaces of walls etc. & applying one coat of white wash complete all as specified and as directed.
Preparation of old decorated plastered/ unplastered surfaces of ceiling etc. & applying one coat of white wash complete all as specified and as directed.
S&F of Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.
M&L for point wiring (Concealed modular) complete for one light point / fan point / exhaust fan point / bell point controlled by one 1-way switch / bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as specified and as directed. Note : 1. The cost of modular type Metal flush boxes and modular accessories like inner/outer cover plates etc is deemed to be included in quoted rate. 2. The cost of cutting chases on wall and making good surface on wall are deemed to be included in the quoted rate. 3. Make of wire for Srl No 1 to 5 & 11 to13 : Polycab / RR Kable / KEI
All as per item ser No 134 above but for One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
All as per item ser No 134 above but for One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
All as per Srl item No. 134 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
S & F Modular switch 1 way 6A , 1 module size complete all as directed.
S & F Modular switch 1 way 16A , 1 module size complete all as directed.
S & F Modular Socket two-in-one, 5 pin, 5 Amp, complete all as specified and directed.
S & F Modular Socket 6 pin, 15 Amp, multipurpose shutter type, 230 volts, complete all as specified and directed.
S & F Modular Socket , 6 A / 16 A , 5 Pin , 2 module size complete all as directed.
S&F in replacement of LED light fitting 1 X 18/20 watt (4 feet), T5 Rechargable Emergency Batten Light, has power backup of 3 to 4 hours, a slim design with internal driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed.
All as per Srl item No. 143 here-in-before but with 1 x 10W (2 feet)
S&F of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with Brush Less Direct Current motor (BLDC) complete all as specified and as directed.
S&F exhaust fan made of strudy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250 mm with cutting chases on brick wall and grounting with nut bolts complete all as specified and as directed.
Supply, install, commissioning and testing for storage type electric Water heater vertical type 25 liters having 5 Star rating as per BEE, including fastner nut and bolts, and making connection complete all as specified and as directed.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated heavy duty armoured electric power cable with stranded aluminium conductor 1100 volts grade 70 Sq mm 3.5 core, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection complete all as specified and as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
All as per item Srl No 148 but 10 Sqmm 4 core
M&L for Sand cushioning to protection of underground cables, laid 8cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18cm thickcomplete all as specified and as directed. Note : Punned thickness shall be measured and sand cover to UG cable,
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning complete all as specified and as directed.
Supply and fixing / laying galvanised pipe 50mm bore medium grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed.
S&F in replacement of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN DB 08 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
S&F for MCB, B Curve type, 10 kA, 40 to 63 Amp, SPN with over load and short circuit protection complete all as specified and directed.
S&F for MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection complete all as specified and directed.
Supply, install, commissioning and testing for hi wall split units indoor / outdoor complete with cordless remote control unit and with in built Heating and cooling arrangement and Digital Inverter twin rotary of capacity 2 TR, single phase 5 star rated with all fiiting, connections and required accessories complete all as directed. Make : Daikin / Hitachi / Carrier
All as per item No 156 but capacity of 1.5 TR
Supply, install, commissioning and testing for voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type, dsigned for input variation between having input voltage 130 V to 280 V, with output voltage stablized at 230 V with accuracy of (+/-) 25% with time delay and digital display with auth scroll input and output voltage complete and of capacity 5 KVA complete all as specified and directed.
All as per item No 158 but capacity of 4 KVA
M&L for sub main wiring using two single core 4 Sqmm FRLS PVC insulated with unsheathed cable with copper conductor 1100 volts grade ISI marked drawing with casing capping and including accessorie like bends, tee etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed.
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Supply, installation, testing and commissioning, in replacement, Junction box, cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and directed.
Bhagwati Construction Company
Diva Infra
M/S MAJISA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .