Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.6 LAccepted-Finance G 4 106 107 1ST FLOOR SECTOR 11 ROHINI NEW DELHI 110085 | NORTH WEST | DELHI | 110085 | ₹73.6 L | L1 | Accepted-Finance L1 Bidder |
| 2 | L2₹76.0 L+₹2.4 L (3.26%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | ₹76.0 L+₹2.4 L (3.26%) | L2 | Rejected-Finance L2 Bidder |
| Sl No | Description | Qty | Unit | VOLKS ENERGIE PVT LTD L2 | AQUATICS ENIGINEERS L1 |
|---|---|---|---|---|---|
| 1.00 | SITC of 1.5 TR split type 5 star AC (inverter type-minimum ISEER 5.0) consisting of single room evaporator unit comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit copper coil with sealed suitable type compressor and suitable for operation on 230V, 50Hz AC supply, non CFC refrigerant like R32 or equivalent capable of performing (a) cooling (b) Air-Circulating (c) filtering including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre.
b) Suitable insulated copper pipe for suction line of dia as per OEM specification for length upto 3 Metre.
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply and Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC, of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc. complete as required. | 12 | Job | 49,283 ₹5,91,396 | 40,000 ₹4,80,000 Lowest |
| 2.00 | Supply of 1.5 TR split type 5 star AC (inverter type-minimum ISEER 5.0) consisting of single room evaporator unit comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit copper coil with sealed suitable type compressor and suitable for operation on 230V, 50Hz AC supply, non CFC refrigerant like R32 or equivalent capable of performing (a) cooling (b) Air-Circulating (c) filtering , supply of inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Supply of suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre.
b) Supply of suitable insulated copper pipe for suction line of dia as per OEM specification for length upto 3 Metre.
c) Supply of suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC, of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc. complete as required. | 4 | Job | 47,283 ₹1,89,132 | 36,000 ₹1,44,000 Lowest |
| 3.00 | Installation testing and commissioning of 1.5 TR split AC units including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit in suitable stand/ mounting structure including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) L:aying of insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre.
b) Laying of insulated copper pipe for suction line of dia as per OEM specification for length upto 3 Metre.
c) Laying of FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc. complete as required. | 6 | Job | 3,500 ₹21,000 | 3,000 ₹18,000 Lowest |
| 4.00 | SITC of 1.5 TR split type 3 star AC (non-inverter type-minimum ISEER 3.5) consisting of single room evaporator unit of copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit with copper coil with sealed suitable type compressor and suitable for operation on 230V, 50Hz AC supply, non CFC refrigerant like R32 or equivalent capable of performing (a) cooling (b) Air-Circulating (c) filtering including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr. comprising of the following including first charge of refrigerant, complete as required.
a) Suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre
b) Suitable copper pipe for suction line of dia as per OEM specification for length upto 3 Metre
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable or as per OEM specification for length upto 3 Metre
d) Supply and Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC, of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc., complete as required. | 10 | Job | 44,198 ₹4,41,980 | 38,000 ₹3,80,000 Lowest |
| 5.00 | Supply of 1.5 TR split type 3 star AC (non-inverter type-minimum ISEER 3.5) consisting of single room evaporator unit of copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit with copper coil with sealed suitable type compressor and suitable for operation on 230V, 50Hz AC supply, non CFC refrigerant like R32 or equivalent capable of performing (a) cooling (b) Air-Circulating (c) filtering ,supply of inter connections between evaporator unit and condensing unit up to a length of 3 mtr. comprising of the following including first charge of refrigerant, complete as required.
a)Supply of Suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre
b) Supply of Suitable copper pipe for suction line of dia as per OEM specification for length upto 3 Metre
c) Supply of Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable or as per OEM specification for length upto 3 Metre
d) Supply of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC, of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc., complete as required. | 2 | Job | 42,198 ₹84,396 | 35,000 ₹70,000 Lowest |
| 6.00 | Supply and fixing of following for interconnections between evaporator unit and condensing unit mentioned in item No 1 and 2 (for additional length) including all accessories etc. complete as required
a) Suitable insulated copper pipe for liquid line of dia as per OEM specification for the item No 1&2 with minimum insulation thickness of 1/2 inch.
b) Suitable insulated copper pipe for suction line of dia as per OEM specification for the item No 1&2 with minimum insulation thickness of 1/2 inch
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for the item No 1&2
d) Supply and Fixing of Heavy duty Rigid type PVC Pipe/Plastic Trunking which shall be decided by EIC as per site conditions, and of suitable size for covering in the refrigerant drain line, liquid line, suction line and multi strand copper cable, drain line as required as per site conditions as required for the item No 1&2, complete as required. | 50 | Mtr | 1,171 ₹58,550 | 1,100 ₹55,000 Lowest |
| 7.00 | SITC of 2 TR split type 5 star AC (inverter type-minimum ISEER 5.0) consisting of single room unit (evaporator unit) comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit (copper coil) with sealed suitable type compressor and suitable for operation on 230 V, 1 phase 50Hz. AC supply , non CFC refrigerant like R32 capable of performing (a) cooling (b) Air-Circulating (c) filtering including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Suitable insulated copper pipe for liquid line or as per OEM specification for length upto 3 Metre.
b) Suitable copper pipe for suction or as per OEM specification for length upto 3 Metre .
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply and Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC of suitable size for covering in the liquid line, suction line and multi strand copper cable, drain line as required as per site conditions etc., complete as required. | 6 | Job | 59,283 ₹3,55,698 | 50,000 ₹3,00,000 Lowest |
| 8.00 | Supply of 2 TR split type 5 star AC (inverter type-minimum ISEER 5.0) consisting of single room unit (evaporator unit) comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit (copper coil) with sealed suitable type compressor and suitable for operation on 230 V, 1 phase 50Hz. AC supply , non CFC refrigerant like R32 capable of performing (a) cooling (b) Air-Circulating (c) filtering , supply of inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Supply Suitable insulated copper pipe for liquid line or as per OEM specification for length upto 3 Metre.
b) SupplySuitable copper pipe for suction or as per OEM specification for length upto 3 Metre .
c)Supply Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC of suitable size for covering in the liquid line, suction line and multi strand copper cable, drain line as required as per site conditions etc., complete as required. | 2 | Job | 56,953 ₹1,13,906 | 46,000 ₹92,000 Lowest |
| 9.00 | Installation testing and commissioning of 2 TR split type 5 star AC units including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Laying of insulated copper pipe for liquid line or as per OEM specification for length upto 3 Metre.
b) Laying of copper pipe for suction or as per OEM specification for length upto 3 Metre .
c) Laying of FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking of suitable size for covering in the liquid line, suction line and multi strand copper cable, drain line as required at site ., complete as required. | 2 | Job | 3,500 ₹7,000 | 3,000 ₹6,000 Lowest |
| 10.00 | SITC of 2 TR split type 3 star AC (non-inverter type-minimum EER 3.5) consisting of single room evaporator unit comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit copper coil with sealed suitable type compressor and suitable for operation on 230 V, 1 phase 50Hz. AC supply, non CFC refrigerant like R32 capable of performing (a) cooling (b) Air-Circulating (c) filtering including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre
b) Suitable insulated copper pipe for suction line of dia as per OEM specification for length upto 3 Metre.
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply and Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC of suitable size for covering in the liquid line, suction line, multi strand copper cable, drain line as required at site etc. complete as required. | 16 | Job | 53,351 ₹8,53,616 | 47,500 ₹7,60,000 Lowest |
Tender Value
₹78.3 L
EMD Value
₹2.3 L
Closing Date
26 Mar 2026, 11:00 amClosed
DGMEE
Calicut International Airport Karippur Malappuram 673647
Replacement of Outlived Air conditioners and Water Coolers installed at Calicut International Airport Phase II
2026_AAI_269495_1
AAI/CL/ENGG-E/301/NIT-12/25-26
Open Tender
Electrical Works
Works
270 days
AAI calicut International Airport
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,180
₹2.3 L
19 Aug 2026
4 Mar 2026
27 Mar 2026
5 Mar 2026
26 Mar 2026
5 Mar 2026
5 Mar 2026 - 12 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of 1.5 TR split type 5 star AC (inverter type-minimum ISEER 5.0) consisting of single room evaporator unit comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit copper coil with sealed suitable type compressor and suitable for operation on 230V, 50Hz AC supply, non CFC refrigerant like R32 or equivalent capable of performing (a) cooling (b) Air-Circulating (c) filtering including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre.
b) Suitable insulated copper pipe for suction line of dia as per OEM specification for length upto 3 Metre.
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply and Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC, of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc. complete as required. | 12 | Job | 1,336 | ₹16,032 |
| 2 | Supply of 1.5 TR split type 5 star AC (inverter type-minimum ISEER 5.0) consisting of single room evaporator unit comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit copper coil with sealed suitable type compressor and suitable for operation on 230V, 50Hz AC supply, non CFC refrigerant like R32 or equivalent capable of performing (a) cooling (b) Air-Circulating (c) filtering , supply of inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Supply of suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre.
b) Supply of suitable insulated copper pipe for suction line of dia as per OEM specification for length upto 3 Metre.
c) Supply of suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC, of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc. complete as required. | 4 | Job | 2,149 | ₹8,596 |
| 3 | Installation testing and commissioning of 1.5 TR split AC units including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit in suitable stand/ mounting structure including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) L:aying of insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre.
b) Laying of insulated copper pipe for suction line of dia as per OEM specification for length upto 3 Metre.
c) Laying of FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc. complete as required. | 6 | Job | 4,878 | ₹29,268 |
| 4 | SITC of 1.5 TR split type 3 star AC (non-inverter type-minimum ISEER 3.5) consisting of single room evaporator unit of copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit with copper coil with sealed suitable type compressor and suitable for operation on 230V, 50Hz AC supply, non CFC refrigerant like R32 or equivalent capable of performing (a) cooling (b) Air-Circulating (c) filtering including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr. comprising of the following including first charge of refrigerant, complete as required.
a) Suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre
b) Suitable copper pipe for suction line of dia as per OEM specification for length upto 3 Metre
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable or as per OEM specification for length upto 3 Metre
d) Supply and Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC, of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc., complete as required. | - | Job | 8,595 | - |
| 5 | Supply of 1.5 TR split type 3 star AC (non-inverter type-minimum ISEER 3.5) consisting of single room evaporator unit of copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit with copper coil with sealed suitable type compressor and suitable for operation on 230V, 50Hz AC supply, non CFC refrigerant like R32 or equivalent capable of performing (a) cooling (b) Air-Circulating (c) filtering ,supply of inter connections between evaporator unit and condensing unit up to a length of 3 mtr. comprising of the following including first charge of refrigerant, complete as required.
a)Supply of Suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre
b) Supply of Suitable copper pipe for suction line of dia as per OEM specification for length upto 3 Metre
c) Supply of Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable or as per OEM specification for length upto 3 Metre
d) Supply of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC, of suitable size for covering in the liquid line, suction line, multi strand copper cable, and drain line as required at site etc., complete as required. | 2 | Job | 16,609 | ₹33,218 |
| 6 | Supply and fixing of following for interconnections between evaporator unit and condensing unit mentioned in item No 1 and 2 (for additional length) including all accessories etc. complete as required
a) Suitable insulated copper pipe for liquid line of dia as per OEM specification for the item No 1&2 with minimum insulation thickness of 1/2 inch.
b) Suitable insulated copper pipe for suction line of dia as per OEM specification for the item No 1&2 with minimum insulation thickness of 1/2 inch
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for the item No 1&2
d) Supply and Fixing of Heavy duty Rigid type PVC Pipe/Plastic Trunking which shall be decided by EIC as per site conditions, and of suitable size for covering in the refrigerant drain line, liquid line, suction line and multi strand copper cable, drain line as required as per site conditions as required for the item No 1&2, complete as required. | 50 | Mtr | 542 | ₹27,100 |
| 7 | SITC of 2 TR split type 5 star AC (inverter type-minimum ISEER 5.0) consisting of single room unit (evaporator unit) comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit (copper coil) with sealed suitable type compressor and suitable for operation on 230 V, 1 phase 50Hz. AC supply , non CFC refrigerant like R32 capable of performing (a) cooling (b) Air-Circulating (c) filtering including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Suitable insulated copper pipe for liquid line or as per OEM specification for length upto 3 Metre.
b) Suitable copper pipe for suction or as per OEM specification for length upto 3 Metre .
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply and Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC of suitable size for covering in the liquid line, suction line and multi strand copper cable, drain line as required as per site conditions etc., complete as required. | 6 | Job | 514 | ₹3,084 |
| 8 | Supply of 2 TR split type 5 star AC (inverter type-minimum ISEER 5.0) consisting of single room unit (evaporator unit) comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit (copper coil) with sealed suitable type compressor and suitable for operation on 230 V, 1 phase 50Hz. AC supply , non CFC refrigerant like R32 capable of performing (a) cooling (b) Air-Circulating (c) filtering , supply of inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Supply Suitable insulated copper pipe for liquid line or as per OEM specification for length upto 3 Metre.
b) SupplySuitable copper pipe for suction or as per OEM specification for length upto 3 Metre .
c)Supply Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC of suitable size for covering in the liquid line, suction line and multi strand copper cable, drain line as required as per site conditions etc., complete as required. | 2 | Job | 58,328 | ₹1,16,656 |
| 9 | Installation testing and commissioning of 2 TR split type 5 star AC units including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Laying of insulated copper pipe for liquid line or as per OEM specification for length upto 3 Metre.
b) Laying of copper pipe for suction or as per OEM specification for length upto 3 Metre .
c) Laying of FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking of suitable size for covering in the liquid line, suction line and multi strand copper cable, drain line as required at site ., complete as required. | 2 | Job | 323 | ₹646 |
| 10 | SITC of 2 TR split type 3 star AC (non-inverter type-minimum EER 3.5) consisting of single room evaporator unit comprising copper coil with cordless remote control, suitable external voltage stabilizer unit and one number outdoor condensing unit copper coil with sealed suitable type compressor and suitable for operation on 230 V, 1 phase 50Hz. AC supply, non CFC refrigerant like R32 capable of performing (a) cooling (b) Air-Circulating (c) filtering including fixing the outdoor condenser unit on a raised suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand included in the scope) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 3 mtr, connection of drain pipe comprising of the following including first charge of refrigerant, complete as required.
a) Suitable insulated copper pipe for liquid line of dia as per OEM specification for length upto 3 Metre
b) Suitable insulated copper pipe for suction line of dia as per OEM specification for length upto 3 Metre.
c) Suitable FR insulated, PVC sheathed unarmoured multi strand copper cable as per OEM specification for length upto 3 Metre
d) Supply and Fixing of Heavy duty Rigid type PVC pipe / PVC Trunking as decided by EIC of suitable size for covering in the liquid line, suction line, multi strand copper cable, drain line as required at site etc. complete as required. | 16 | Job | 256 | ₹4,096 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
tenderdocument.pdf
Tender Documents • 10.18 MB
BOQ_314018.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .