Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.0 LAccepted-AOC | 1 | Accepted-AOC Lowest and eligible bidder | |
| 2 | 2₹31.7 L+₹4.7 L (17.5%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹31.9 L+₹4.9 L (18.1%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹32.1 L+₹5.1 L (18.8%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹33.9 L+₹6.9 L (25.4%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
28 Oct 2021, 6:00 pmClosed
Garrison Engineer Kota
Dadwara Complex, Military Station, Kota - 324002
CERTAIN REPAIRS TO ROOF TREATMENT, SUNKEN PORTION AND CONNECTED ITEMS IN SOUTHERN SECTOR AND REPAIR/ MAINTENANCE OF INTERNAL WIRING AND CONNECTED WORKS AT MIL STN KOTA
2021_MES_480852_1
8574/E8
Open Tender
Civil Works
Item Rate
183 days
Kota
Class D category a(i)
9 documents required · 9 mandatory
₹500
GE Kota
₹60,000
Yes
3 Dec 2021
9 Oct 2021
5 Nov 2021
9 Oct 2021
28 Oct 2021
23 Oct 2021
11 Oct 2021 - 16 Oct 2021
Amount
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Demolition/Dismantling of existing normal roof treatment, any type from RCC roof slab including lime concrete/PCC padding over roof, removing layer of bitumen under lime concrete/PCC padding, cement mortar, felt etc and cleaning the surface by hacking to receive plaster and removing demolished materials outside MD land, complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles, complete all as specified and directed.
M&L for PCC 1:2:4 mix type B-0 (Using 12.5 mm graded crushed stone agg) for roof padding, leveling course to receive floor finishes etc, complete all as specified and directed.
M&L brushing neat cement slurry with 3.00 kg cement per Sqm, complete all as specified and directed.
M&L for applying 15 mm thick screed in CM 1:4 on roof slabs with using liquid water proofing compound as per manufacturer's instructions, complete all as specified and directed. (Liquid WPC shall be measured and paid separately).
Supply only approved liquid water proofing compound, complete all as specified and directed.
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm.
Item 8.00 Contd........ (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates.
M&L for cleaning of walls and floor of sunken portions including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS: 3384 @ 0.40 Kg/Sqm, torching overlaps with a propane or a butane gas torch with an overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold applied bituminous primer all as per manufacturer’s instructions, complete all as directed. Note: (i) The waterproofing treatment shall be got carried out through the manufacturer or their authorized applicators only.
M&L cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M & L for plain cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate) as in filling under floors & like etc complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles, throating and including neccesary formwork complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L brick work with old size pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparing new previously untreated plastered surfaces of walls and applying two coats of cement based paint over and including a coat of suitable primer, complete all as specified and directed.
S & F of unions brass to connect iron to polyethylene and fixed for 20 mm bore complete all as specified and directed.
S & F in renewal of 20mm bore dia of pipe nipple suitable for HDPE water tank (Minimum weight 20mm- 45gms) complete all as specified and directed.
S & F in renewal of 25mm bore dia of pipe nipple suitable for HDPE water tank (Minimum weight 25mm- 65gms) complete all as specified and directed.
S&F in renewal of 20 mm dia ball brass valve, high pressure with polythene float and fly nut, screwed down for iron pipe or for brass ferrule & fixed, complete all as specified and directed.
S&F of 20 mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms), complete all as specified and directed.
S&F in renewal of 20 mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms), complete all as specified and directed.
S&F in renewal of gun metal globe or gate valve of size 20 mm dia with iron wheel head screwed both ends and for iron pipe & fixed, complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 15 mm bore pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 20 mm bore pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 25 mm bore pipes complete all as specified and directed.
Supply, fixing, laying & testing 15 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Supply, fixing, laying & testing 20 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Supply, fixing, laying & testing 25 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Disconnecting existing tanks capacity exc. 250 Ltr but not exc. 500 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately) complete all as specified and directed.
Disconnecting existing tanks capacity exc. 500 Ltr but not exc. 1000 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately) complete all as specified and directed.
Dismantling existing water storage tank of any description of capacity exc. 250 Ltr but n.exc. 500 Ltr, complete all as specified and directed.
S&F in position rotational moulded polyethylene water storage tanks 500 Ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position, complete all as specified in SSR Part I and as directed. Note :- PVC tanks shall be ISI marked and having three layers.
S&F in renewal of vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest & including one 'P' of 'S' trap & incl providing lime concrete bedding and connecting to flusing cistern, complete all as specified and directed.
S&F in renewal of 10 Ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle & including brackets and superior quality PVC 32 mm bore flush pipe, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring cable of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface including providing wooden rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces, complete all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps.
Ditto all as per item No 39.00 (here-in-above) but one 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
Ditto all as per item No 39.00 (here-in-above) but one 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
Ditto all as per item No 39.00 (here-in-above) but one light point controlled by two, two way switch of 5/6 Amps.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including providing wooden rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surface, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC concealed conduit not less than 20 mm dia including with all accessories and fittings, fixed in concealed & including providing MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces, complete all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate.
Ditto all as per item No 44.00 (here-in-above) but one 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
Ditto all as per item No 44.00 (here-in-above) but one 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
Ditto all as per item No 44.00 (here-in-above) but one light point controlled by two, two way switch of 5/6 Amps.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC concealed conduit not less than 20 mm dia including with all accessories and fittings, fixed in concealed for one socket outlet 15 amp on independent board & including providing MS sheet metal sunken switch /Terminal box 1.2mm thick and fittings for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surface, complete all as specified and directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, Two way, ISI marked, complete all as specified & directed.
Supply and fixing switch socket combination, 5/6 and 15/16 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing socket outlet, 5/6 Amps, 230 volt, five pin, flush type universal, complete all as specified and directed.
S&F in renewal of stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 50mm, 3 terminals, complete all as specified & directed.
S&F PVC/polycarbonate lamp holder, angular/batten type with back plate, ISI marked complete all as specified & directed.
S&F bell push AC, SP, 240 volts, flush type, 5 Amp/ 6 Amp, complete all as specified and directed.
S&F in renewal of call bell, AC, 230 volts, single pole, ISI marked complete all as specified & directed.
Fixing only in renewal of LED light fittings, batten type of 10/ 11/18/20/22 Watts complete all as specified and directed. Note for Srl item Nos 58 to 60 :- (i) LED light fittings as stipulated in the items shall be issued under on Schedule 'B' for fixing only at store yard of AGE E/M Kota. (ii) Cost of Necessary tools and plants such as ladders, hydra for renewal of LED light fittings etc and wiring from ceiling rose to light point should be deemed to be included in the unit rate quoted.
Fixing only in renewal of recess LED panel (2'x2') light fittings of 36 watt with and including all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to light fitting connection etc complete all as specified and directed.
Fixing only in renewal of recess LED flat panel light fittings, with high britness LED for glare-free homogenous illumination & including LED lamp 10 to 20 Watts complete all as specified and directed.
Fixing only in renewal of LED building security light fitting, 25 watt & including 0.55 m long street light bracket made of 32 mm bore GI light grade tubing including necessary clamps, nuts, bolts, washers etc, complete all as specified and directed. Note :- (i) LED building security light fitting of 25 Watts shall be issued under Schedule 'B' for fixing only at store yard of AGE E/M Kota. (ii) Cost of supply of GI bracket as described under the item should be deemed to be included in the unit rate quoted. (iii) Cost of Necessary tools and plants necessary for repair works shall be arranged by Contractor and wiring from ceiling rose to light fitting should be deemed to be included in the unit rate quoted.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed.
S&F MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed.
S & F, MCB TPN 63 Amps, 415 volts, four pole, B-curve, rupturing capacity 16KA conforming to IS-8828-1996, IEC-60898, complete, all as specified & directed by Engineer-in- charge.
S & F, MCB TPN 40 Amps, 415 volts, four pole, B-curve, rupturing capacity 16KA conforming to IS-8828-1996, IEC-60898, complete, all as specified & directed by Engineer-in- charge.
S & F factory made MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 8 ways, Double door, complete all as specified and directed. Note for items of MCB DB - (1) The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S & F factory made MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, IP-43-IK09 protection grade, earth bar and Din rail, 415 Volts TPN with 4 ways, Double door, complete all as specified and directed.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 4 Sqmm LT, 1100 volts grade, drawn through and including PVC casing capping not less than 20 mm width with accessories such as socket, elbow, junction box, bell mouth, reducer, bend etc. and fittings and one run of 4 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor, on surface of wall/roof/floors for SPN DB's to switch boards complete all as specified & as directed. Note :- Two runs of cable one run of earth wire and one run of PVC casing capping not less than 20 mm width shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC casing capping.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 6 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor, complete all as specified & as directed. Note :- Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 10 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 10 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor, complete all as specified & as directed.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth wire of 4 dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 5 and including dismantling of old u/s earthing complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 5 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5 m. Any variation below or above shall be measured and paid for separately under relevant item of this Sch ‘A’.
S&F in renewal of earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.
M/S MOHINI ENTERPRISES
L P Singh and Co.
SK Guha and co
Ganesh Contruction
S AND A ENGINEERS CONSTRUCTION CO
SHREEKRISHNA INFRASTRUCTURE
TARKESHWAR DASS CONSTRUCTION COMPANY
M/s Prem Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .