Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.9 LAccepted-AOC | ₹16.9 L | 1 | Accepted-AOC Awarded |
| 2 | 2₹17.2 LRejected-AOC | ₹17.2 L | 2 | Rejected-AOC Not Awarded |
| 3 | 3₹17.9 LRejected-AOC | ₹17.9 L | 3 | Rejected-AOC Not Awarded |
| 4 | 4₹18.8 LRejected-AOC | ₹18.8 L | 4 | Rejected-AOC Not Awarded |
Tender Value
₹16.9 L
EMD Value
₹17,000
Closing Date
27 Jan 2020, 5:00 pmClosed
S.E., E.T.C., Bareilly
Superintending Engineer Hydel Campus, Near L.I.C. Office Rampur Garden, Bareilly
Replacement of 33KV Main Bus Bar Conductors of Single AAC Tarantula Conductors/ACSR Moose/Zebra Conductors by Twin ACSR Moose Conductors alongwith other associated Works at 132KV Sub Station Dohna under E.T.D.-II, Bareilly
2020_UPTCL_421492_1
E-Tender No. 78 / W / ETC(B) / 2019 - 20
Open Tender
Electrical Works
150 days
Bareilly
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
A/c No 10897666087 IFSC SBIN0000615 S.B.I. Bly
₹17,000
18 Sept 2020
8 Jan 2020
28 Jan 2020
8 Jan 2020
27 Jan 2020
8 Jan 2020
8 Jan 2020 - 27 Jan 2020
Amount
Replacement of 33KV Main Bus Bar Conductors of Single AAC Tarantula Conductors / ACSR Moose / Zebra Conductors by Twin ACSR Moose Conductors alongwith other associated Works at 132KV Sub Station Dohna, with all Cost of Men, Materials (as per Technical Specifications & Sample), Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer, as per Details below : Supply of Bolted type Single Suspension Fitting Assembly, suitable for Twin ACSR Moose Conductors and 33KV Suspension Disc Insulator String, comprising of 3 No. 70 KN Disc Insulators, complete with Hardware Fittings, Socket Eye, Ball Hook, Yoke Plate, J-Hook etc., as per Technical Specifications & Sample.
Supply of Bolted type Single Tension Fitting Assembly with Turn Buckle, suitable for Twin ACSR Moose Conductors and 33KV Bus Bar Disc Insulator String, comprising of 4 No. 70 KN Disc Insulators, complete with Hardware Fittings, D-Shackle, Socket Eye, Ball Hook, Yoke Plate, D-Clip, Tension Clamp etc., as per Technical Specifications & Sample.
Supply of Bolted type Single Tension Fitting Assembly without Turn Buckle, suitable for Twin ACSR Moose Conductors and 33KV Bus Bar Disc Insulator String, comprising of 4 No. 70 KN Disc Insulators, complete with Hardware Fittings, D-Shackle, Socket Eye, Ball Hook, Yoke Plate, D-Clip, Tension Clamp etc., as per Technical Specifications & Sample.
Supply of Spacer, suitable for 33KV Bus Bar of Twin ACSR Moose Conductors with 250 mm Spacing and duly made of LM-6 Aluminium Alloy, complete with 12 mm dia. HDG Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of PG Clamp duly made of LM-6 Aluminium Alloy, suitable for ACSR Moose to ACSR Moose Conductors, complete with 4 No. 16 × 90 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of PG Clamp duly made of LM-6 Aluminium Alloy, suitable for ACSR Moose to ACSR Panther Conductors, complete with 4 No. 16 × 90 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of PG Clamp duly made of LM-6 Aluminium Alloy, suitable for ACSR Panther to ACSR Panther Conductors, complete with 3 No. 16 × 75 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of 33KV C.T. Bi-Metallic Terminal Connector duly made of LM-6 Aluminium Alloy alongwith Bi-Metallic Sleeve / Plate, suitable for Twin ACSR Moose Conductors complete with 4 No. 12 mm size G.I. Bolts, Nuts & Spring / Plain Washers, as per Technical Specifications & Sample.
Supply of 33KV C.B. Terminal Connector duly made of LM-6 Aluminium Alloy, suitable for Twin ACSR Moose Conductors complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of 33KV Isolator Bi-Metallic Terminal Connector duly made of LM-6 Aluminium Alloy, suitable for Twin ACSR Moose Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of 33KV Post Insulator Clamp duly made of LM-6 Aluminium Alloy, suitable for Twin ACSR Moose Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Opening of Jumpers of ACSR Moose / Zebra / Panther Conductors between Existing 33KV Main Bus Bar Conductors to Main Bus Isolator, 33KV Main Bus Bar Conductors to Bus Section Isolator and 33KV Main Bus Bar Conductors to Bus PTs & LAs; 33KV Main Bus Isolator to C.B., C.B. to CTs, CTs to LAs, LAs to L.V. Bushings of in 33KV side of 63MVA T/F and 40MVA T/F - I & II and 33KV Main Bus Isolators to C.B., C.B. to C.T., C.T. to L.I., L.I. to Transfer B.I. in various 33KV Feeders / Transfer Bus Coupler Bays alongwith Shifting of the Dismantled Conductors, Clamps, Connectors etc. from Switchyard to Stores at the Sub Station. (1 Job for each Jumper)
De-Stringing & Dismantling of Existing 33KV Main Bus Bar Conductors of Single AAC Tarantula Conductors / ACSR Moose / Zebra Conductors including De-hoisting of Disc Insulator Tension String with associated Tension Fitting and Disc Insulator Suspension String with associated Suspension Fitting from Gantry alongwith Shifting of the Dismantled Conductors, Tension Fittings, Suspension Fittings etc. from Switchyard to Stores at the Sub Station. (1 Job for each Phase of each Section of the Main Bus Bar)
Laying & Re-Stringing of 33KV Main Bus Bar Conductors by Twin ACSR Moose Conductors including Hoisting of Disc Insulator Tension String with associated Tension Fitting and Disc Insulator Suspension String with associated Suspension Fitting alongwith Shifting of the new Conductors, Tension Fittings, Suspension Fittings, Spacers etc. from Stores at the Sub Station to the Switchyard. (1 Job for each Phase of each Section of the Main Bus Bar)
Fixing of 250 mm size Spacers between above Laid 33KV Main Bus Bar Conductors of Twin ACSR Moose Conductors. (1 Job for each Spacer)
Jumpering with Twin ACSR Moose / Panther Conductors between newly Laid 33KV Main Bus Bar Conductors of Twin ACSR Moose Conductors to Main Bus Isolator, 33KV Main Bus Bar Conductors to Bus Section Isolator and 33KV Main Bus Bar Conductors to Bus PTs & LAs; 33KV Main Bus Isolator to C.B., C.B. to CTs, CTs to LAs, LAs to L.V. Bushings of in 33KV side of 63MVA T/F and 40MVA T/F - I & II and 33KV Main Bus Isolators to C.B., C.B. to C.T., C.T. to L.I., L.I. to Transfer B.I. in various 33KV Feeders / Transfer Bus Coupler Bays by due Cutting & Bending of Conductors and Tightening of the Jumpers with P.G. Clamps / Equipments Terminal Connectors etc. alongwith Shifting of the Conductors, P.G. Clamps, Equipments Connectors etc. from Stores at the Sub Station to the Switchyard. (1 Job for each Jumper)
M/S JAI SHREE ENTERPRISES
LASHANI ENTERPRISES
NIRMAL ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid