| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.8 LAccepted-AOC | L-1 | Accepted-AOC lowest | |
| 2 | L-2₹21.4 L+₹22,982.65 (1.09%)Rejected-Finance | L-2 | Rejected-Finance other than lowest | |
| 3 | L-3₹22.2 L+₹1.1 L (5.28%)Rejected-Finance | L-3 | Rejected-Finance other than lowest | |
| 4 | L-4₹23.1 L+₹1.9 L (9.15%)Rejected-Finance ALSAFA COLONY SOPORE SOPORE ALSAFA COLONY 193201 SOPORE BARAMULLA JAMMU KASHMIR 193201 | BARAMULLA | JAMMU AND KASHMIR | 193201 | L-4 | Rejected-Finance other than lowest | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
30 Aug 2021, 6:00 pmClosed
GE 969 EWS
GE 969 EWS
SPECIAL REPAIR TO BUILDING NO. T-29,T-92,T-93 AT PATTAN UNDER GE 969 EWS.
2021_MES_465015_1
CANO 969/WS- /2021-22
Open Tender
Civil Works
Item Rate
180 days
Pattan
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 969 EWS
₹40,000
Yes
17 Jan 2022
4 Aug 2021
31 Aug 2021
4 Aug 2021
30 Aug 2021
16 Aug 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed by engineer-in-charge.
M&L for Glazed ceramic tile 600 x 300 x 10mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified and directed by engineer-in-charge.
M&L for vitrified ceramic tiles light shade 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 SQM, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6) complete all as specified and directed by engineer-in-charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and directed by engineer-in-charge.
M&L for 75mm thick PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified and directed by engineer-in-charge.
Demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by engineer-in-charge.
M&L for Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and directed by engineer-in-charge.
Dismantling of wall and ceiling board (fibre ,pulp ,insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by engineer-in-charge.
S&F 6mm thick veneered decorative plywood , grade 1(with BWR resign) with decorative face veneers on one side faces, , fixed with nails to timber frame work in ceiling incl french polish complete all as specified and directed by engineer-in-charge.
S&F 6mm thick veneered decorative plywood , grade 1(with BWR resign) with decorative face veneers on one side faces, , fixed with nails to frame work on walls. french polish complete all as specified and directed by engineer-in-charge.
M & L for 6 mm thick ply wood, grade, BWR type BB, fixed with nails to timber frame work as in ceiling etc, complete all as specified and directed by engineer-in-charge.
M&L for 2nd class soft wood, plain fillets, square, rectangular or triangular in section, clean sawn, secured in nails or brads cross sectional exceeding 6 sqcm & n. exc. 13 sq. cm complete all as specified and directed by engineer-in-charge.
Dismantling timber scantling 40 sq cm and over in section in any position as in unframed work comp- lete all as specified and directed by engineer-in-charge.
M&L for IInd class soft(wood) as in scantling clean sawn, fixed to timber frame work complete all as specified and directed by engineer-in-charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by engineer-in-charge.
M & L for 0.63mm thick Class VIII galvanised corrugated or semi-corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc in roofing complete all as specified and directed by engineer-in-charge.
All as per item No. 16 above but except sheets complete all as specified and directed by engineer-in-charge.
M & L for 0.80mm thick plain Galvanised mild steel sheeting, in ridges, hips, facia boarding, valley gutters, drip and straight flashings (length and girth as fixed with grade of zinc coating fixed with new J-hooks/L-hooks/cranked hook bolts etc complete all as specified and directed by engineer-in-charge.
Preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint on Steel sheeting as in roofing complete all as specified and directed by engineer-in-charge.
Taking down chowkat or frames not exc 1.5 Sqm with shutters of any description (without taking off shutters from the frame) complete all as specified and directed by engineer-in-charge.
Taking down chowkat or frames exc 1.5 Sqm but not exe 4 sqm with shutters of any description (without taking off shutters from the frame) complete all as specified and directed by engineer-in-charge.
S&F for 2nd Class softwood in Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints complete all as specified and directed by engineer-in-charge.
M&L for 35mm thick, 2nd class soft wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fit complete all as specified and directed by engineer-in-charge.
M&L for 35 mm thick, 2nd class softwood , glazed & skeleton shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc. for door complete all as specified and directed by engineer-in-charge.
S & F of Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and directed by engineer-in-charge.
All as per item No.25 but 75 mm mm long complete all as specified and directed by engineer-in-charge.
S&F Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and directed by engineer-in-charge.
S&F Aluminium handles cast type anodised of size 100mm long ISI marked complete all as specified.
S&F of 150 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed by engineer-in-charge.
S&F 100 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed by engineer-in-charge.
S &F CP centre Hole Mixer for hot & cold water complete all as specified and directed by engineer-in-charge.
S&F of 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by engineer-in-charge.
S & F in repairs tabletop Vitreous China wash hand basin oval (countertop) white of size 560x410mm complete all as specified and directed by engineer-in-charge.
S&F 15mm Bib tap brass, chromium plated,fancy with capstan handle screwed down screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by engineer-in-charge.
Taking down GI tubing 15mm and connection including cleaning for refixing or removal to store complete all as specified and directed by engineer-in-charge.
S &F 15 mm 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed by engineer-in-charge.
Dismantling boarding, any description, fixed any position with nails, complete all as specified and directed by engineer-in-charge.
M&L for 2nd class soft wood weather boarding, clean sawn, plain, 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and directed by engineer-in-charge.
M&L for 20 mm granite (of any type) work (table rubbed and polished) cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by engineer-in-charge.
Painting to old wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by engineer-in-charge.
M&L Plain Cement concrete Type D-2, 1:4:8 (40mm graded aggregate), in foundation, filling and masss concrete complete all as specified and directed by engineer-in-charge.
M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed by engineer-in-charge.
M & L Cement concrete 25 MM Thick type B-0, 1:2:4 ( 12.5 mm graded aggregate finished the surface even and fair complete all as specified and directed by engineer-in-charge.
S & F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed by engineer-in-charge.
S&F CP Tubular towel rail 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and directed by engineer-in-charge.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed by engineer-in-charge.
M&L for Machine cut kota stone flooring 18-20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 20 mm thick screed bed in cement and sand mortar 1:3 including 75 mm wide white marble border lining complete all as specified and directed by engineer-in-charge.
M&L for 2nd class soft wood facia boarding planed one side with butt joints 20mm thick complete all as specified and directed by engineer-in-charge.
All as per item 49 above but except weather boards complete all as specified and directed by engineer-in-charge.
Material and labour 2nd class hardwood, plain fillets, square, rectangular or triangular in section, clean sawn, secured in nails or brads cross sectional exceeding 13 sqcm & n. exc. 25 sq. cm specified and directed by Engineer in Charge
Taking down shutter of any description exc 1 sqm and n.exc 2sqm complete and removing from site complete all as specified and directed by engineer-in-charge.
Refixing shutters of any description in same opening exc 1 Sqm and n.exc 2 sqm complete all as complete all as specified and directed by engineer-in-charge.
S&F of Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by engineer-in-charge.
M&L of 2nd class soft wood sectional area Not exc 3 Sqm Plain fillets. square, rectangular or triangular in section, clean sawn, se-cured with nails or brads complete all as specified and directed by engineer-in-charge.
S&F 18mm thick prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by engineer-in-charge.
S&F CP Brass cromium plated peg set of 04 complete all as specified and directed by engineer-in-charge.
M&L for applying two coats of synthetic enamel paint, over a coat of pink primer of new surface of wood of any description not otherwise description over 10cm width or girthcomplete all as specified and directed by engineer-in-charge.
Taking down cement plaster or screed bedding layer of any description from concrete slab/terrace surfaces etc including racking out joints hacking for key, scrubbing down with water etc.complete all as specified and directed by engineer-in-charge.
M&L Rendering 15 mm thick on brick work or concrete surface in CM (1:6) and rendering is to be finished even and smooth w/o using extra cement complete all as specified and directed by engineer-in-charge.
All as item 60 above but in cm 1:4 complete all as specified and directed by engineer-in-charge.
S&F 2nd class soft wood for boarding 25mm thick clean sawn with butt joint fixed with nails in any position complete all as specified and directed by engineer-in-charge.
Preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint on Steel sheeting as in roofing complete all as specified and directed.
Preparing on plastered surfaces and applying distem pering walls with distemper dry, white or tinted complete all as specified and directed by engineer-in-charge.
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed by engineer-in-charge.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqmm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point/fan point/ex fan point controlled by one 5 Amps switch one way
(b) One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed by engineer-in-charge.
(c)One 3 pin 5 Amp switch socket outlet on same board with accessories complete all as specified and directed by engineer-in-charge.
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor complete all as specified and directed by engineer-in-charge.
S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and directed by engineer-in-charge.. Note : Taking down of swithches included in taking down point wiring
S&F switch piano Flush type, single pole 16 amp 240 volts, complete all as specified and directed by engineer-in-charge.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed by engineer-in-charge.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and directed by engineer-in-charge.
S&F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed by engineer-in-charge.
S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body complete all as specified and directed by Engr-in-Charge
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed by engineer-in-charge.
Taking carefully ceiling fans by disconnectig electric connections, fan blades, etc put in safe custody for repair under relvant items of schedule Note:- The cost of required T & P, flat form lader shall be included in the quoted rates complete all as specified and directed by Engr-in-Charge
Repair and re-fixing, re-assembling the existing cealing fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, painting fan blades, changing fan bearning, rewinding of fan, write MES no on fan blades including nut, bolts and washers complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Distribution Board, SPN 12 Way, Single door 240 volts, , flush/surface mounting with 200 Amp rated bus bar and neutral link, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Distribution Board, SPN 08 Way, Single door 240 volts, , flush/surface mounting with 200 Amp rated bus bar and neutral link, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Distribution Board, SPN 04 Way, Single door 240 volts, , flush/surface mounting with 200 Amp rated bus bar and neutral link, complete all as specified and as directed by Engr-in-Charge.
S & F MCB SP 6 to 32 Amps, 240 Volts, Gold plus MCB B Curve complete all as specified and as directed by Engr-in-Charge
S & F MCB, DP 40 Amps 415 Volts Gold plus MCB C Curve complete all as specified and as directed by Engr-in-Charge
S&F LED Lamp 15 Wcomplete all as specified and as directed by Engr-in-Charge
S & F Bulkhead luminaire comprising of high brightness LEDs 10W LED, IP-65 with lamp holders, etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz complete all as specified and as directed by Engr-in-Charge
S&F New E-Lite Decorative ultra slim round profile LED lighting 20W fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack complete with 20W LED tube complete all as specified and as directed by Engr-in-Charge
M&L for Sub main wiring with 2 runs of 10 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC casing capping of required size with accessories along with 1 run of 10 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed by Engr-in-Charge. Note :- Two runs of 10 sqmm and one runs of 10 sqmm cable as earth along with PVC conduit will be measured as one length.
M&L for XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade of cross sectional area 16 sq. mm 2 core complete all as specified and as directed by Engr-in-Charge
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 mtr deep in depth for laying of cable and foundation of poles, stays and getting out in any type of soil complete all as specified and directed by engr in charge.
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in-Charge
Returning, filling in, excavated soil including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and as directed by Engr-in-Charge
Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed. (Note: The punned down thickness shall only be measured)
Supply and laying sub class 'B' bricks laid across the cable for cable protection complete all as specified and as directed by Engr-in-Charge
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc all as specified and directed by Engr-in-Charge
NAJAR ENTERPRISES
M/S MUKHTAR CONSTRUCTION CO
M/S GHULAM NABI KHUROO AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .