Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
10 Sept 2026, 6:00 pm
Executive Engineer, Panchayat Road and Building Division, Morbi
Annual Rate 2026-27 Repairs to Various Nand Ghar Building in Morbi and Halvad SubDivision in Morbi District Under Juridician of Panchayat R&B Division-Morbi(2nd Attempt)
340172
80 /2026
Open
Civil - All
Works
Morbi
10 documents required · 10 mandatory
₹1,500
Executive Engineer, Panchayat Road and Building Division, MORBI
₹50,000
29 Aug 2026
29 Aug 2026
29 Aug 2026
10 Sept 2026
29 Aug 2026
BILL OF QUANTITY
Memorandum showing items of works to be carried out
Item No. Discription of Item (With Brief Specification and reference to Quantity Unit Rate In Amount
book of Specification) Figures
In Figure Rs. Ps
1 Excavation for foundation upto 1.5 m depth including sorting out and 1.000 Cum 254.37
stacking of useful materials and disposing off the excavated stuff
upto All Lead & Lift.(C) Hard Murrum.
2 Excavation for foundation upto 1.5 m depth including sorting out and 1.000 Cum 264.82
stacking of useful materials and disposing off the excavated stuff
upto 50 Meter lead.(D) Soft rock not requiring Blasting
3 Providing and laying cement concrete 1:4:8 (1 cement, 4sand,8 1.000 Cum 2830.46
machine crushed stone aggregates 40 mm.Nominal size)and curing
complete, excluding cost of formwork in(a) Foundation and Plinth
4 Providing and laying ordinary cement concrete1:1:2 (1cement,1sand, 1.000 Cum 5810.34
2 gradedstone aggregates 20 mm.Nominal size) and finishing
smooth with curing etc. complete excluding cost of form work and
reinforcement for reinforced cement concrete work in in A)
Foundations, footings, base of columns and mass concrete
5 Providing and laying ordinary cement concrete1:1.5:3 1.000 Cum 10253.78
(1cement,1.5sand, 3 gradedstone aggregates 20 mm.Nominal size)
and finishing smooth with curing etc. complete including the cost of
formwork but excluding the cost of reinforcement of R.C.C. work in
Column (iii) Having cross-sectional area more than 0.085 Sq.M. and
6 Brickwork using common burnt clay building brick shaving crushing 1.000 Cum 4021.02
strength not less than 35 Kg/Sqcm. in foundation and plinth in
cement mortar 1:6(1 Cement ; 6 Fine sand) Conventional bricks
7 Filling in foundation and plinth with murrum or selected soil in layers 1.000 Cum 289.06
of 20cm. thickness including watering, ramming and consolidating
8 Brickwork using common burnt clay building brick shaving crushing 1.000 Cum 4289.33
strength not less than 35 Kg/Sqcm. in super structure Upto floor two
level in cement mortar 1:6(1 Cement ; 6 Fine sand)
9 Half Brickmasonary in commonburnt clay building bricks having C.S. 1.000 Sqm 703.64
not less than 35 Kg/Sqcm.in Foundation and Plinth in cement mortar
1:3 (1cement: 3 coarse sand) with 2 Nos.of 6mm.dia. Mild steel
round bars after every Three course embedded in cement mortar.
Modular upto Floor Two Level
10 Providing and laying cement concrete1:1.5:3 (1cement,1.5sand, 3 1.000 Cum 6772.95
gradedstone aggregates20 mm.Nominal size) and curing complete,
including cost of formwork in sill and sides (R.C.C. band) but
excluding the cost of reinforcement upto floor two level
11 Providing & laying ordinary C.C. 1:1 1/2:3 ( 1 cement ,1 1/2 course 1.000 Cum 9943.81
sand, 3 graded stone agg. of 20 mm nominal size )and for R.C.C.
LINTELS incl. Finishing smooth with curring of formwork but excl.
the cost of reinforcement.for above floor upto Floor two level.
12 Providing & laying cement concrete 1:11/2:3 (1 cement ,11/2 course 1.000 Cum 6743.82
sand,3graded stone agg.of 20 mm nominal size) for rein-forcement
concrete CHHAJJAS not exceeding 10cm. thickness upto floor two
level incl. finishing the exposed surface with C.M. 1:3 (1 cement
fine sand) to give a smooth and ever surface, centering, formwork
and curring comp.Excl. the cost of reinforcement.above plinth Upto
floor two level.
13 Providing & laying C.C. 1:11/2:3 (1 cement ,11/2 course sand,3 1.000 Cum 7877.05
graded stone agg.of 20 mm nominal size) and finishing smooth with
curring etc. comp. incl. the cost of formwork but excl. the cost of
reinforcement for R.C.C. work in. (A) Beam :- Having cross
sectional Area 0.085 to 0.12 Sqm.upto floor two level
14 Providing & laying ordinary cement concrete1:11/2:3 (1 cement 1.000 Cum 7099.60
,11/2 course sand,3 graded stone agg.of 20 mm nominal size)
exposed work with curring etc.comp. incl. the cost of formwork but
excluding the cost of reinforce ment for R.C.C. work in. SLAB :-
having more then 10cm. and end upto 13cm. thickness.upto All floor
15 Providing TMT Bar FE 500/500D reinforcement for R.C.C. work 1.000 Kg 76.21
including bending, binding and placing in position complete upto
floor two level
16 Providing fixing of Polished Marble Colour or Black frame for Doors 1.000 Sqm 3181.89
& Windows, Platform including necessary holdfasts, holes for fixtures
and fastenings incl. all labour & materials etc. comp
17 Providing and fixing 35mm. Thick Panelled,glazed orPanelled and 1.000 Sqm 3755.92
glazed shutters for doors,windows andclearstory windows including
anodised alluminiumbutt hinges with necessary screws and Indian
TeakWood shutters with-(B) Partical board panells.12mm. thick
including applying primer and two coats of oil painting etc. complete
18 20mm thick sand faced cement plaster on walls upto height 10 1.000 Sqm 300.66
metres above ground level consisting of 12mm thick backing coat of
C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M.
1:1 (1-cement : 1-sand) etc. complete.
19 Providing 10 mmthick cement plaster in single coat on fair side of 1.000 Sqm 129.02
Brick/concrete walls for interior plastering upto floor two level and
finished even and smooth in (I)cement mortar 1:3 (1 cement:3 sand)
20 Providing and laying 24" x 24" vitrified 8MM thick tile flooring over 1.000 Sqm 1406.22
20MM (average) base of cement mortar 1:6 (1- Cement : 6-Coarse
Sand) on new surface or fixing on existing flooring by adhe-sive
material including dismentalling of existing flooring and jointed with
colour cement slurry including finished with flush pointing and
cleaning the surface etc. complete. For Light shade
21 Providing and laying Ceramic tiles 6mm thick in flooring treads of 1.000 Sqm 970.07
steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-
cement : 3-coarse sand ) finishing with flush pointing in white cement
22 Providing and laying Ceramic tiles 6mm thick in skrting risers of 1.000 Sqm 1038.39
steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-
coarse sand) and jointed with white cement slurry
23 Applying two coats of Birla or Asian acrylic lapy ( putty) & two coats 1.000 Sqm 40.59
of primer of approved brand and manufacture on new wall surface
to give an even shade including thoroughly brushing the surface free
from mortar dropping and other foreign matter and sand papered
24 Finishing wall with weather proof exterior emulsion paint on wall 1.000 Sqm 114.53
surface(two coats) to give an required shape even shade after
thoroughly brushing the surface to rempve all dirt, and remains of
loose powdered materials etc complete.
25 Distempering (Two coats) with oil bound distemper of approved 1.000 Sqm 73.02
brand and manufacture and of required shade on wall surface to give
an even shade over and including a priming coat with distemper
primer of approved brand and manufacture after thoroughly brushing
the surface free from mortar dropping and other foreign matter and
also including preparing the surface even and papered smooth.
26 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having 1.000 No 958.17
weight not less than 35Kg.
27 Proving and fixing water closet squatting pan (Indian type W.C.Pan) 1.000 No 1371.38
size 580 mm. incl. 100mm. Size P trap & Foot rest(Earthwork, bed
concrete,foot rests and trap to be measured and paid for separately)
(A) Vitreous china (I) Long pattern white colour.
28 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 1.000 No 558.36
mm diameter with jali of the following nominal diameter of self
cleansing design with C.I scread down or hinged grating including
the cost of cutting and making good the walls.
29 Proving and fixing cast iron spigot and socket soil, waste and 1.000 Rm 890.46
ventilating pipes of the following nominal size.(C) 100 mm. Dia.
30 Proving and fixing in position cowl vent to pipes(C) 100 mm. Dia. 1.000 No 501.87
31 Providing and fixing S.W. gully trap with C.I. grating brick masonry 1.000 No 1292.19
chamber and water tight C.I. cover with frame of 300mm x 300mm
size (inside) with standard weight.(i) Square mouth traps. (A)
100mm x 100mm size P type.
32 Constructing brick masonry road gully chamber 450mm x 450mm x 1.000 No 3504.02
775mm with vertical grating complete With C.I. Manhole Cover
450x600 mm size
33 Providing and fixing washbasin with single hole for pillar tap with C.I. 1.000 No 2305.23
or M.S. brackets painted white including sutting holes and making
good (A) Vitreous China:(ii) Flat Back washbasin 550 mm x 400mm
size. (i) In white colour. with CP brass couplin, padastal matching
the shade, waste pipe,rubber pipe etc complete.
34 Providing, laying and jointing in true line and level 110 diametre 1.000 Rm 835.15
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system pipe line, pipe
shall be jointed with each other with rubber lubricant, pipe shall be
fixed on wall using of PVC clamp of the size 110 mm diametre x
mm length x 145 mm heigh at every 2000 mm center to center or
shall be concealed in walls as directed including necessary fittings
such as bends, shoes etc. including testing of pipes and joints and
jointed with adhesive solvent cement including cost of all materials.
35 Providing and fixing concealed center point to wall ceiling & floor 1.000 Rm 333.66
CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube
fittings and clamps including making good the wall, ceiling and floor
etc. complete. [D] 32mm.
36 Providing and fixing concealed center point to wall ceiling & floor 1.000 Rm 205.00
CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube
fittings and clamps including making good the wall, ceiling and floor
etc. complete. [B] 20mm.
37 Providing and fixing screw down bib taps of following size.(B) Brass 1.000 No 189.86
chromium plated screws down Bib Tap. (i) 15mm dia.
38 Proving sock pit of 5.0 Cumt. Volume including excavating and filling 1.000 No 3126.07
brick bats with dry masonary work at top for 45 cm. Height including
covering the top with stone including providing vatas in c.m. 1;3 with
finishing,curing etc. complete as directed.
39 Proving and Fixing double coated Syntex or Equivalent PVC ( ISI) 1.000 Ltr 3.95
mark water tank of required capacity each with all necessary fittings
and connection etc. comp on terrace or as directed by Engineer - in-
40 Providing and laying broken china mosaic flooring for terrace 1.000 Sqm 747.29
using 12 mm to 20 mm broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be tempered to bring
mortar creme out upto surface using white cement including
rounding off junctions and extending them upto 15 cm along the
wall,clearing with water and oxalic acid etc. as directed.
41 Providing and fixing extruded aluminum window having extruded 1.000 Sqm 2140.33
aluminum Colour Powder Coated section frame main outer size
127mm x 38.10mm x 1.35mm ,@ Wt.1.384 Kg/mt,horizontal Four
track member size 122.20mm x 31.75mm x 1.10mm @ Wt.
Kg/mt,vertical member of size 122.20mm x 31.75mm x 1.50mm ,@
Wt. 1.398 Kg/mt with sliding shutters of horizontal member size
40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,vertical member of
size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,@ with 5 mm
thick transparent bronze colour tinted float glass with powder coated
aluminum fittings and fixtures and transparent silicon sealant glass
fixing to frame as per details etc complete for window.
42 Providing and fixing M.S. Grills of required pattern to frames of Pipe / 1.000 Kg 166.45
Angles etc.including Priming coat of approved primer and Two coats
of Oil painting etc. complete ORNAMENTAL grill
43 Providing and fixing 30mm thick FACTORY MADE SOLID BOTH 1.000 Sqm 2236.14
SIDE PRELAM PANEL PVC DOOR SHUTTER consisting of frame
made out of M.S. tubes of 19 gauge thickness and size of 19mm x
19mm for stiles, top and bottom rails. M.S. frame shall have a coat of
steel primer of approved makde and manufactures. M.S frame
covered with 5mm thick heat moulded prelim PVC ‘C’ channel of siz
30mm thickness, 70 mm width of which 50mm shall be flat and
20mm shall be tapered in 45 degree Angle on either side forming
stiles, and 5mm thick, 95mm wide pream PVC sheet out of which
75mm shall be flat and 20mm shall be tapered in 45 degree on the
inner side ot form top and bottom rail and 115mm wide prelim PVc
sheet out of which 75nmm shall be flat and 20mm shall be tapered
on both side to form lock rail, Top, bottom and lock rails shall be
provided either side of the panel. 10mm (5mm x 2) thick 20mm wide
cross PVC sheet shall be provided as gap insert for top rail and
bottom rails. Panelling of 5mm thck both side prelim PVC sheet to be
fitted in the M.S. frame welded,sealed to the stiles and rails with
7mm (5mm + 2 mm) thick x 15mm wide PVC sheet beading on inner
side, and joined togeth with solvent cement adhesive. An additional
5mm thick PVC strip of 20mm width is to be stuck on the interior side
of the ‘C” chanel using PVC solvent adhesive etc. complete as per
direction of Engineering in charge, manufacture’s specification and
44 Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 1.000 Point 419.15
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires, in following type of pipe to be
erected concealed in/ on surface on wall/ceiling complete with 6A
Modular type switch / bell push & accessories and earth continuity
of following type, erected on PVC / Metallic box, single mounting
base frame covered with textured/metallic front plate modules
erected on / in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories Cat- III
45 Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm 1.000 Point 598.93
(Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated
multistrand copper wires, in following type of pipe to be erected
concealed in / flushed on wall/ceiling complete with 6A Modular type
switch and hum free EME four or more step type electronic fan
regulator with separately mounted and accessories with earth
continuity of following type erected on PVC / Metallic box, single
mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessoriesCat- III
46 Point wiring for Looped Plug with 6A Modular type switch & 5 pin 1.000 Point 241.39
socket erected on PVC / Metallic box, single mounting base frame
covered with textured / metallic front plate modules erected on / in
wall / ceiling with following type accessories Cat- III
47 Point wiring for individual Plug with & Earth wire of FRLS PVC 1.000 Point 445.41
insulated multistrand copper wires, in following type of pipe to be
erected concealed in / surface of wall/ceiling complete with Modular
type switch and 5 Pin plug erected on PVC/ Metallic box covered
with appropriate front plate modules erected on / in wall/ ceiling as
per pipe erected with following type of
(I) For 6A Plug with 2-1.5 Sq.mm Cu. wire
(a) With medium class rigid PVC Pipe and accessories - Cat_III
48 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 1.000 No 295.93
Watt to 0.5 Watt assembled on single MCPCB, with housing used
as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name 160V to
270V, Power Factor more than 0.95, THD < 15%, CCT 3000 K to
6500K, Luminaire efficacy> 85 lumens/watt ,LED LED driver
efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates) (A)
Tube Light with integral driver (iii) 18-20 Watts, Surge - 2KV,IP-20,
conventional 4 feet
49 Providing and erecting Miniature circuit breaker single pole 6A to 1.000 No 112.11
25A suitable to operate on 240 V A.C. system and having breaking
capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark. Cat-lll
50 Providing & erecting 240 V MCB double pole switch for lighting load 1.000 No 295.93
(B Curve) having 10 KA breaking capacity & Confirming to IS :8828
in Existing box , having capacity
(B) 40 Amp.- Cat-III
51 Providing and erecting Sheet Steel powder coated MCB distribution 1.000 No 1492.78
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without
MCB to house appropriate nos. of MCBs.(The DBs should be used
of same company of MCB to be used) (H) Single phase 12 way SS
52 Providing & erecting Approved make Ceiling Fan with double ball 1.000 No 1596.81
bearing ISI mark with Condenser 230 volt A.C. 50 c/s, 1200 mm
sweep complete having 3blades with aluminium blades with
canopy & 30 cms. down rod erected on existing hook or Clamp with
24/ 0.2, 3 core flexible wire with earthing.
53 Providing and Erecting following Shock Proof Tissino Type 1.000 No 209.07
accessories erected on 3 mm thick PC (Polycarbonate) Sheet in
PVC / Metal Box erected on Wall / Ceiling. (14) Electronic Hum Free
EME Socket Type Step Fan Regulator.
54 Supplying Erecting Aproved make Bracket Fan of ISI Mark with 230 1.000 No 2105.85
Volt A.C., 50 Cy/S 400/450 mm Sweep complete on Wall or With
lead cores and connections complete.Category II
55 Pipe type earthing having 150 cms.long and 2.5 cms. dia. galvanised 1.000 No 540.35
iron pipe with coupling and buch buried in specially prepared earth
pit complete with necessary 8 SWG earth wire. For using salt and
charcoal / coke as required for pipe type earthing.
56 Mains with 1.1 KV FRLS PVC insulated ISI Marked Standard Copper 1.000 Rm 59.59
Conductor wire in following Type of Pipe to be erected Concealed in
/ Flushed on Wall / Ceiling with 1.5 Sq.mm Copper Conductor FRLS
PVC Insulated Standered wire of Green Colour for Earth continuity of
following size. (A) With Medium Class Rigid PVC Pipe and
Accessories. (a) 2 wire 1.5 Sq.mm.
57 Supplying & erecting approved make self-priming domestic 1.000 No 6575.10
monoblock water pump with 0.5 H.P. motor, suitable for operation on
230 volts 50 c/s. AC supply with metallic flange, delivery and
discharge of 32 LPM at 10 mtrs.head. Cat.III
58 Providing and fixing 600mm x 450mm bevelled edge mirrror of 1.000 No 833.73
superior glass mounted on 6mm thick A.C. sheet or plywood sheet
and fixing to wooden pluge with C.P. brass screws and washers.
59 Providing and fixing pre-cast Rubber Dye / steel Dye inter locking 1.000 Sqm 686.90
concrete block 60mm thick with grade of concrete M300 pnumatic
compressed / vibrated mechanically and as per approved design
Confirming to IS 15658 : 2006 including 35 mm Sand layer for
levelling and filling the joint with sand in proper line and level as per
guidlines of IRC : SP 63-2018 etc. Complete.
60 Providing & Fixing Enhancement of indoor : Soft-boards, 1.000 No 20200.00
blackboards, Storage areas & wall paintings etc. complete as per
instruction of enginer-in-charge.
61 Providing & Fixing miscellaneous Play / Activities and indoor 1.000 No 10100.00
installations & Notice Board as per instruction of enginer-in-charge.
62 Providing & Fixing Nand Ghar Logo as per instruction of enginer-in- 1.000 No 2020.00
63 Dismentaling tiled of stone floors laid in mortar including stacking of 1.000 Sqm 48.63
serviceable materilas and disposal of unserviceable materials with
all lead and lift.
64 Dismentling doors, windows, ventilators etc. (wood or steel) shutters 1.000 No 190.19
including chowkhats architraves, holdfasts and other attachment etc.
complete and stacking them within all lead and lift.(i) Not exceeding
3 Sq.M. in area.
65 Dismentling doors, windows, ventilators etc. (wood or steel) shutters 1.000 No 254.68
including chowkhats architraves, holdfasts and other attachment etc.
complete and stacking them within all lead and lift.(ii) Exceeding
66 Dismentling C.I. pipes G.S.W.pipes abd A.C. rain water pipes with 1.000 Rm 75.92
fittings and clamps including stacking the materials with all lead and
lift ( for any dia, of pipe)
67 Dismantling santtary fittings like wash basin . W.C. pan Indian and 1.000 No 410.13
European type, flushing tank etc. including stacking the materials
with all lead and lift
68 Demolition of Brick work and stone masonry including stacking of 1.000 Cum 557.32
serviceable materilas and disposal of unserviceable materials with
all lead and lift.(ii) In Cement Mortar.
69 Demolition including stacking of serviceable materilas and disposal 1.000 Cum 1071.63
of unserviceable materials with all lead and lift. (i) R.C.C. work
Dismentled Material Credit Rs. 0 will be deducted from 1 St R.A.
Rupees One Lakh Forty Eight Thousand Four Hundred Thirty Five and Paise Eighteen only
I \ We am \ are willing to carry out the work at ……………………… % above\bellow percent ( Should
be written in figures and words ) of the estimated rate mentioned above. Amount of My \ Our tender works
* Estimated Amount * Estimated Amount
Put to tender Rs…………………… Put to tender Rs……………………
Deduct……..……..% Add……..……..%
In words………………….……………… In words………………….………………
1.The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge
for which no extra payment shall be made.
2.The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3.GST and Income tax TDS will be deducted at a source while making payments of bills
4.In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017
Cement Consumption/16/C Date:11/05/2017 as stated in
S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost
of difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned in
all the tender.
Signature of Contractor
Deputy Executive Engineer Executive Engineer
Panchayat R.& B. Sub Division Panchayat R.& B. Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1 SBD Nandghar Building Repairs 2026-27.pdf
2 Sarato Nandghar Building Repairs 2026-27.pdf
3 Spe.Index Nandghar Building Repairs 2026-27.pdf
4 Specification Nandghar Building Repairs 2026-27.pdf
5 Sch -B.pdf
6 Building Circular.pdf
7 Test Shedual Nandghar Building Repairs 2026-27.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].