Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC DOOR NO 7 2 30 3 OPP APSEB SUB STATION OLD GAJUWAKA MARRIPALEM VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | ₹27.5 L Quoted ₹28.3 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹29.5 LRejected-AOC 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹29.5 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹37.7 LRejected-AOC | ₹37.7 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹46.0 LRejected-AOC | ₹46.0 L | L4 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | newton electro technics L1 | SHIKHARA PROJECTS L4 | MVV Prasad L2 | M/s SURYA INFRA L3 |
|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: E/M WORKS | |||||||
| 1.00 | Periodical checking including comprehensive and breakdown maintenance of electrically operated fire alarm panel including all detectors, MCP, Sounder/Siren, repeater panels and other devices and accessories connected with the panel including wiring/cable connecting all the devices associated with the fire alarm panel including battery/battery charger etc. located at different locations (NAD,INS Eksila,INS DEGA,NCB,9 IRSD Area,NSV,Nirman Park,SVN Colony,MOV(Old and New),INS Visawkarma,BVY, DSRV, CE(N) Complex etc) and other areas under the maintenance area of GE (ND) (V) for maintaining existing fire alarm System by carrying out periodic checks, cleaning and dusting of all system components as recommended by manufacturer / as directed by Engineer-in-charge to ensure smooth / safe and efficient operation including repair/ replacement of all spare parts/accessories etc of compatible make as specified by the OEM/ as directed by Engr-in-Charge required to keep the fire alarm systems in good and safe working condition. The fire alarm system/Detection system consists of the following :- | 296 | Each panel Each month | 1,130 ₹3.3 L | 1,600 ₹4.7 L | 1,032 ₹3.1 L | 1,500 ₹4.4 L |
| 1.10(a) Microprocessor based addressable networking type Fire alarm control panel and repeater panel of Apollo/Honeywell /Siemens/Ravel/Agni/Godrej/Airlight/Morley/Notifier/Safeway etc make, with supply unit heavy duty Battery charger and allied components. | |||||||
| 2.00 | All as per item No.1 but the Microprocessor based addressable networking type GSM enabled Fire alarm control panel and repeater panel of Apollo/Honeywell /Siemens/Ravel/Agni/Godrej/Airlight/Morley/Notifier/Safeway etc make, with supply unit heavy duty Battery charger, updating of software including recharging of sim card and allied components. | 80 | Each panel Each month | 1,190 ₹95,200 | 1,400 ₹1.1 L | 1,400 ₹1.1 L | 1,850 ₹1.5 L |
| 3.00 | (b) All as per item No.1 but the Microprocessor based conventional type Fire alarm control panel of and repeater panel Apollo/Honeywell /Siemens/Ravel/Agni/Godrej /Airlight / Morley/Notifier/Safeway etc make, with supply unit heavy duty Battery charger, and allied components without GSM. | 224 | Each panel Each month | 1,130 ₹2.5 L | 990 ₹2.2 L | 1,300 ₹2.9 L | 1,250 ₹2.8 L |
| 4.00 | All as per item No.1 but the Microprocessor based conventional type GSM enabled Fire alarm control panel of and repeater panel Apollo/Honeywell /Siemens/Ravel/Agni/Godrej /Airlight / Morley/Notifier/Safeway etc make, with supply unit heavy duty Battery charger, updating of software including recharging of sim card and allied components. | 24 | Each panel Each month | 1,190 ₹28,560 | 3,500 ₹84,000 | 1,400 ₹33,600 | 1,600 ₹38,400 |
| 4.10Note:- For item No. 1 to 4 here in before:- (i) In the event of any fire alarm panel remains non functional for a period of more than 7 days a penalty of Rs. 500 per day will be deducted over and above the penalty imposed as per IAFW 2249 and other condition of CA. Decision of GE will be final and binding in this regard and the time period will be from the time of complaint received by SMS/Emails. | |||||||
| 4.20(ii) Major spares for repair will be measured and paid seperately as "Supply Only" under relevant items of this CA. Any other spares which is not included in CA but required to make the FADS functional deemed to be included in the quoted rate and the tenderer must visit site before quoting the tender to see present condition of the fire alarm Panels and connected devices & accessories. Nothing will be paid etc other than the materials specified in the supply only schedule for keeping the fire alarm/detection system in working condition. | |||||||
| 4.30(iii) Each complaint to be supported with job card and the rates quoted are deemed to be incl of necessary stationary charges. | |||||||
| 4.40(iv) The quoted rate is deemed to be inclusive of suitable technician / manpower, conveyance and communication to labour in complete GE(ND) area, tools and plants required for the maintenance etc. | |||||||
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Dec 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
COMPREHENSIVE MAINTENANCE OF FIRE ALARM AND DETECTION SYSTEM UNDER AGE EM AT GE ND VISAKHAPATNAM
2025_MES_741065_1
8543/GEND/E8
Open Tender
Electrical and Maintenance Works
240 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹90,000
Yes
19 Feb 2026
21 Nov 2025
22 Dec 2025
21 Nov 2025
20 Dec 2025
6 Dec 2025
Amount
SCHEDULE 'A' PART-I: E/M WORKS
Periodical checking including comprehensive and breakdown maintenance of electrically operated fire alarm panel including all detectors, MCP, Sounder/Siren, repeater panels and other devices and accessories connected with the panel including wiring/cable connecting all the devices associated with the fire alarm panel including battery/battery charger etc. located at different locations (NAD,INS Eksila,INS DEGA,NCB,9 IRSD Area,NSV,Nirman Park,SVN Colony,MOV(Old and New),INS Visawkarma,BVY, DSRV, CE(N) Complex etc) and other areas under the maintenance area of GE (ND) (V) for maintaining existing fire alarm System by carrying out periodic checks, cleaning and dusting of all system components as recommended by manufacturer / as directed by Engineer-in-charge to ensure smooth / safe and efficient operation including repair/ replacement of all spare parts/accessories etc of compatible make as specified by the OEM/ as directed by Engr-in-Charge required to keep the fire alarm systems in good and safe working condition. The fire alarm system/Detection system consists of the following :-
(a) Microprocessor based addressable networking type Fire alarm control panel and repeater panel of Apollo/Honeywell /Siemens/Ravel/Agni/Godrej/Airlight/Morley/Notifier/Safeway etc make, with supply unit heavy duty Battery charger and allied components.
All as per item No.1 but the Microprocessor based addressable networking type GSM enabled Fire alarm control panel and repeater panel of Apollo/Honeywell /Siemens/Ravel/Agni/Godrej/Airlight/Morley/Notifier/Safeway etc make, with supply unit heavy duty Battery charger, updating of software including recharging of sim card and allied components.
(b) All as per item No.1 but the Microprocessor based conventional type Fire alarm control panel of and repeater panel Apollo/Honeywell /Siemens/Ravel/Agni/Godrej /Airlight / Morley/Notifier/Safeway etc make, with supply unit heavy duty Battery charger, and allied components without GSM.
All as per item No.1 but the Microprocessor based conventional type GSM enabled Fire alarm control panel of and repeater panel Apollo/Honeywell /Siemens/Ravel/Agni/Godrej /Airlight / Morley/Notifier/Safeway etc make, with supply unit heavy duty Battery charger, updating of software including recharging of sim card and allied components.
Note:- For item No. 1 to 4 here in before:- (i) In the event of any fire alarm panel remains non functional for a period of more than 7 days a penalty of Rs. 500 per day will be deducted over and above the penalty imposed as per IAFW 2249 and other condition of CA. Decision of GE will be final and binding in this regard and the time period will be from the time of complaint received by SMS/Emails.
(iii) Each complaint to be supported with job card and the rates quoted are deemed to be incl of necessary stationary charges.
(vi) The contractor has to inspect the functionality and keep in working conditions of each system components like Fire alarm panel, smoke detector/Multi sensor, Manual call point, Beam detector, Sounder/hooter cum strobe, Isolator module, Response indicator, Battery, Battery Charger, flame detector and other components of internal fire alarm system complete.
(vii) The functionality of all the fire alarm systems shall be the responsibility of the contractor during the entire contract period .
(viii) The accounting unit of each panel will be considered as Panel including all connected devices and accessories including repeater panel fixed against the main panel.
Supply only Manual call point addressable resettable type, as in repairs, complete all as specified and as directed by Engineer-in-Charge. Make : Agni/Vertex/Ravel
Supply only Manual call point conventional resettable type, as in repairs, complete all as specified and as directed by Engineer-in-Charge. Make : Ravel/Vertex/Leo
Supply installation & testing and commissioning of addresseble loop card/power supply module/ mother module/ system software suitable for installed addresseble fire alarm panel complete all as specified and directed.
Supply installation & testing and commissioning of GSM communicator which converts the Contact ID codes of the fire alarm panel’s PSTN communicator. For central alarm monitoring: GSM Communicator is special for converting the PSTN Adecco Contact ID codes to readable SMS notifications and SIA-09 IP over GPRS network to central monitoring station (CMS). Available in 2G/3G/4G/LTE mobile network versions. Fire detection and alarm system are to be connected with GSM Module with 2/4G GSM version of. 2G QUAD BAND (850/900/1800/1900 MHz). Direct mount Antenna with SMA Male L-Type Connector – CDMA and WCDMA, 2.5 dBi Gain and 850-2100/2400 MHz. IP communicator for fire alarm control panels, Supports full transmission Contact ID over IP SIA-DC09 event information to security monitoring station. 4/8 general alarm inputs including power supply voltage monitoring via SMS messages,800 remote control users via free short call,800 users control by GSM call or using maxim- Dallas I Button keys, Configuration using standard mini-USB cable
Remote configuration and firmware upgrade, Easy installation. Testing and diagnostic of the module via USB by using program SOFTWARE. Very useful features are troubleshooting and testing of the module via USB PC; this saves time for installer and allows real-time monitoring of module parameters, input/output and GSM modem status (IMEI, SIM, registration) etc. Supports up to 32 temperature sensors or 1 humidity/temperature sensor for automation purposes such as HVAC temperature control, alarm, and control – Optional with extra senser.Free configuration and diagnostic software, Free android APP and WEB Cloud service with Software for Mobile / Tab’s / PC’s. -1Set with each panel (Mobile / Tab’s / PC’s at extra cost). To be connected with existing fire alarm system at various units. Central alarm monitoring at security through cloud-based software (With out ant receiver) with PC/TAB (PC / TAB at extra cost). Make: compatible with Existing Apollo/ Cooper/ Notifier/ Honeywell protocol Fire alarm panel as per international communication protocol standards.
Supply, installation and commissioning of Conventional Auto-Aligning Beam Detector With Laser Alignment .Auto-Aligning Beam Detector 8-50m Supply Voltage 14-36 V DC Operating Current (1 Detector) 6mA (2 Detectors) 8.5mA Operating Current (Alignment mode with 1 37mA or 2 Detectors) Response Threshold (Default 35%) 10-60% Delays (User settable, default 35%) Alarm 2-30 Seconds Fault 2-30 Seconds Operating Distance 8-100 m Operating Temperature Minus 10 to 55 Deg C Storage Temperature Minus 40 to 85 Deg C Humidity (non condensing) 0-93% RH IP Rating 54 Contact Rating 100mA @ 36V DC Cable Length (System controller to detector) 100m (2 Core) Optical Wave Length 850nm Make: Apollo/Honeywell/TNA
Supply only Microprocessor based conventional type Fire alarm control panel with supply unit heavy duty Battery charger and also with complete set up of LCD display, cables, battery , charger, all the spares etc Tested and proved functionally, complete all as specified and as directed by Engineer-in-Charge. Make : Ravel/Vertex/Leo
Supply only batteries (12V 07/12AH) check the termination and connections, as required on site complete all as directed by Engineer-in-Charge.
Supply only Microprocessor based addressable networking type Fire alarm control panel 01 loop of Siemens make, with supply unit heavy duty Battery charger and also with complete set up of LCD display, mother board, cables, battery , charger, all the spares etc Tested and proved functionally, complete including testing all as specified and as directed by Engineer-in-Charge. Make : (Supply only Siemens/Honeywell/Apollo/Ravel or as per sample)
Supply only Detectors complying with and type certified to EN - 45 analog convetional type multi-sensor detector with heat and smoke combination installation, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge. Make : APOLLO /RAVEL/ SYSTEM SENSOR
Supply only UL Listed Analogue addressable smoke detector with 8 digit dip switches for ( 1 to 126/254) address settings,Dual LED indication for 360 degree visibility ,milky white in color,shall be polarity insensitive, Insect filter chamber, easy to install, advanced detection and communication protocol including.all accessries , all as specified and directed by Engr-in-Charge.Make : APOLLO /RAVEL/ SYSTEM SENSOR
Supply only addressable Electronic hooters sounder cum strob including protective box (Buzzers /Alarm sounders) Ravel/Spencer/Vertex makes, complete all as directed.
Supply only Microprocessor based addressable networking type Fire alarm control panel 04 loop of Honeywell make, with supply unit heavy duty Battery charger and also with complete set up of LCD display, mother board, cables, battery , charger, all the spares etc Tested and proved functionally, complete including testing all as specified and as directed by Engineer-in-Charge. Make : (Supply only Siemens/Honeywell/Apollo/Ravel or as per sample)
Supply only conventional Electronic hooters sounder cum strob including protective box (Buzzers /Alarm sounders) Ravel/Spencer/Vertex makes, complete all as directed.
Supply in replacement of 2 core 1.5 sqmm copper cable through rigid PVC conduit, high conductivity anealed bare electrolytic copper conductor 650/1100V grade, PVC insulated pair twisted & screened flexible, both inner and outer FR/FRLSH PVC sheathed with proper pair identification as per IS 1554, part-1 & IS 5831 latest and any other relevant standard complete all as specified and directed.
Supply in replacement of stranded copper conductor, XLPE insulated, cores laid up, PVC Inner sheathed, GI wire armoured & FRLS PVC outer sheath,Insulated with XLPE type GP8 as per BS 7655-1.3, 2x 1.5 sqmm cable with clamps to fit on cable tray or on ground with all associated accessories, complete all as specified and as directed by Engineer-in-Charge. Make : POLYCAB/ PLAZA/ HAVELLS.
Supply only Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2KVA suitable for Fire alarm panel
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in soft soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Supply and laying of HDPE pipe of pressure rating 6 kgf/cm2 laid in trences/surface of 40mm dia complete all as specified & directed
Material and labour for 25 mm dia steel conduit 'light grade' galvanised for cable protection including sealing both ends complete all as specified and as directed by Engineer in charge
Supply only Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB for upto 3500mtr range
Material and labour for point wiring with 4.0 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 20mm PVC conduit totally concealed in walls/ceiling with tee, bend, elbows,junction box etc. with provision of PVC insulated 4.0 sqmm copper conductor cable as earth continuity including 2.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for 15Amp power point controlled by one switch complete all as specified and as directed.
Supply, installation and commissioning of Addressable Auto-Aligning Beam Detector With Laser Alignment .Auto-Aligning Beam Detector 8-50m Supply Voltage 14-36 V DC Operating Current (1 Detector) 6mA (2 Detectors) 8.5mA Operating Current (Alignment mode with 1 37mA or 2 Detectors) Response Threshold (Default 35%) 10-60% Delays (User settable, default 35%) Alarm 2-30 Seconds Fault 2-30 Seconds Operating Distance 8-100 m Operating Temperature Minus 10 to 55 Deg C Storage Temperature Minus 40 to 85 Deg C Humidity (non condensing) 0-93% RH IP Rating 54 Contact Rating 100mA @ 36V DC Cable Length (System controller to detector) 100m (2 Core) Optical Wave Length 850nm Make: Apollo/Honeywell/Ravel
Supply and fixing Modular switch and socket 1 way 16A, Box type 3 module single pole complete all as specified and directed by Engr-in-charge.
M & L for outdoor cabinet type sheet metal enclosure of size 900mmx600mmx450mm with front glass cover latch on type door lock with IP 55 rating including all fitting arrangements for fixing on wall complete all as specified and directed by Engr-in-Charge.
MVV Prasad (BID ID -3497241)
M/s SURYA INFRA (BID ID -3496959)
SHIKHARA PROJECTS (BID ID -3496158)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
tender8543.pdf
Tender Documents • 1.00 MB
BOQ_829811.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid