| 1.00Electrical | ||||||||
| 1.00 | 90.15.2.3:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters | 1 | each | 1,63,000 ₹1,63,000 | 1,84,648.2 ₹1,84,648.2 | 1,48,917.6 ₹1,48,917.6 Lowest | 1,78,658.82 ₹1,78,658.82 | 1,79,587.38 ₹1,79,587.38 |
| 1.00 | 90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 4 | each | 14,100 ₹56,400 Lowest | 22,415.1 ₹89,660.4 | 22,895.6 ₹91,582.4 | 21,684.5 ₹86,738 | 21,797.2 ₹87,188.8 |
| 1.00 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 2.66 | cum | 400 ₹1,065.6 | 368.6 ₹981.95 | 2,816.67 ₹7,503.61 | 356.63 ₹950.06 Lowest | 358.48 ₹954.99 |
| 1.00 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). | 2.66 | cum | 8,980 ₹23,922.72 | 8,978.94 ₹23,919.9 | 8,233.33 ₹21,933.59 Lowest | 8,686.23 ₹23,140.12 | 8,731.37 ₹23,260.37 |
| 1.00 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels | 1.44 | sqm | 380 ₹547.2 | 341.81 ₹492.21 | 3,206.66 ₹4,617.59 | 327.76 ₹471.97 Lowest | 329.47 ₹474.44 |
| 1.01 | OD394212/2023-2024:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete. | 25 | kg | 118 ₹2,950 | 92.47 ₹2,311.75 | 121.21 ₹3,030.25 | 69.69 ₹1,742.25 Lowest | 70.05 ₹1,751.25 |
| 1.01 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm | 30 | metre | 130 ₹3,900 | 102.72 ₹3,081.6 | 474.58 ₹14,237.4 | 98.94 ₹2,968.2 Lowest | 99.45 ₹2,983.5 |
| 1.01 | OD394213/2023-2024:Supply and installation of dust and vermin proof Three-phase Sintex Meterboard (GS MB?6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required | 1 | each | 6,510 ₹6,510 | 384.17 ₹384.17 Lowest | 4,040.4 ₹4,040.4 | 3,993.6 ₹3,993.6 | 4,014.35 ₹4,014.35 |
| 1.01 | OD394214/2023-2024:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board | 1 | each | 362 ₹362 | 1,362.13 ₹1,362.13 | 404.04 ₹404.04 | 351.58 ₹351.58 Lowest | 353.41 ₹353.41 |
Tender Value
₹3.6 L
EMD Value
₹9,059
Closing Date
29 Jul 2024, 6:00 pmClosed
JAYARAJAN V
BLOCK DEVELOPMENT OFFICER, AREEKODE
AREEKODE BLOCK -MPLADS 2023-24- INSTALLATION OF HIGH MAST LIGHT - MUNDAPARAMBU ANAKKALINGAL TOWN, KUZHIMANNA GP- Proposed byADV. JEBI MATHER MP(RS) .- GENERAL ELECTRICAL WORK.
2024_CRD_681743_1
B/1476/2022/22.07.2024
Open Tender
Electrical Works
Item Rate
150 days
KUZHIMANNA, AREEKODE BLOCK PANCHAYATH
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
Yes
₹9,059
Yes
16 Sept 2025
22 Jul 2024
31 Jul 2024
22 Jul 2024
29 Jul 2024
22 Jul 2024
22 Jul 2024 - 29 Jul 2024
Amount
Electrical
90.15.2.3:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters
90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD394212/2023-2024:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete.
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD394213/2023-2024:Supply and installation of dust and vermin proof Three-phase Sintex Meterboard (GS MB?6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required
OD394214/2023-2024:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
OD394215/2023-2024:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD394216/2023-2024:Supply,installation,testing and commissioning of 40A, 2pole , AC1 rated power contactor with 1NO+1NC auxiliary contacts with AC coil and 24Hours timer for operating automatic ON-OFF function suitable for single phase supply
OD394217/2023-2024:Supply and Fixing of 1P+N,40KA,1 module surge protector on existing MCB DB/enclosure/Meter Board etc and giving connection as required. (Schneider A9L40500 or equivalent).
OD394218/2023-2024:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
OD394219/2023-2024:Providing and fixing Granite Board of 500 mm X 400 mm, with inscription on front side as required as per the instruction
Century Electronics and Electricals
HASHID C.K.
SHAHUL HAMEED V
KELTRON LIGHTING DIVISION
Bidder Name
Century Electronics and Electricals
S.K.LIGHTS
KELTRON LIGHTING DIVISION
SHAHUL HAMEED V
HASHID C.K.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1060521.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .