Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹16.1 L+₹25,529 (1.62%)Rejected-AOC BESIDE RANCHI NURSING HOME BOOTY MORE RANCHI 835217 JHARKHAND | RANCHI | JHARKHAND | 835217 | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹16.7 L+₹87,734 (5.55%)Rejected-AOC | L3 | Rejected-AOC Bid is not lowest and reasonable | |
| 4 | L4₹19.1 L+₹3.3 L (21.0%)Rejected-AOC | L4 | Rejected-AOC Bid is not lowest and reasonable | |
| 5 | L5₹19.2 L+₹3.4 L (21.4%)Rejected-AOC VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L5 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Jul 2023, 6:00 pmClosed
GE RAMGARH
GE RAMGARH CANTT
Repair Replacement of Internal Electrification along with all connected items fittings at PRC MD and OTM Accn at Ramgarh Cantt
2023_MES_600818_1
8300/3172/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH
₹40,000
Yes
22 Aug 2023
3 Jun 2023
12 Jul 2023
3 Jun 2023
10 Jul 2023
21 Jun 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches(modular/non modular), ceiling roses, pendants, regulators, sockets,lamp holder , light fitting etc. and removing materials to store for keeping in safe custody or for taking as credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed by Engineer-in-Charge.
M & L for surface point wiring for one light / fan /exhaust fan points controlled by one way 5 Amp switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable, drawn in & including PVC casing & caping non metallic medium grade with fittings (ISI marked) not less than 20 mm size & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet fixed with brass screw for housing/fixing switches etc complete all as specified and directed. Note : Proper coding to be adopted.
All as per item No. 02 mentioned here in before but one 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
All as per item No. 02 mentioned here in before but one 3 pin 5 Amp switch socket outlet on same board with accessories complete all as specified and directed
All as per item No. 02 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed
M & L for surface point wiring for one light/ fan point/exhaust fan point controlled by one 5 Amp switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded FRLSH copper conductor cable PVC insulated-unsheathed, drawn in & including non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia including clamps, screws gutties/plug etc & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches etc fixed with brass screw complete all as specified and directed. Note : Proper coding to be adopted.
All as per item No. 06 mentioned here in before but one 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
All as per item No. 06 mentioned here in before but one 3 pin 5 Amp switch socket outlet on same board with accessories complete all as specified and directed
All as per item No. 06 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 Sqmm wires complete all as specified and directed
M & L for surface point wiring for AC point controlled by one 15 Amps switch one way/metal clad industrial socket with 1100 volt grade PVC insulated-unsheathed 4.0 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of 4.0 Sq mm multi stranded FRLSH copper conductor cable PVC insulated-unsheathed, drawn in & including non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia including clamps, screws gutties/plug etc & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover complete all as specified and directed. Note : Proper coding to be adopted.
M & L for point wiring for one light/fan/bell point controlled by one 5 Amps single pole one way switch. with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded FRLSH copper conductor cable PVC insulated-unsheathed, drawn in existing conduit & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 3.0 mm thick hylum sheet cover ISI marked fixed with brass screw complete all as specified and directed. Note : Proper coding to be adopted.
All as per item No. 11 mentioned here in before but one 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch. with accessories complete all as specified and directed
All as per item No. 11 mentioned here-in-before but one outlet 5/3 pin 5 Amps socket outlet on independent board controlled by one, one way 5 Amps piano switch with accessories complete all as specified and directed
All as per item No. 11 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 Sqmm wires complete all as specified and directed
Supply and fixing building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65/66 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type security lights fitting 35 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nuts, bolts & washers as required at site for fixing of security lights on LT pole/ wall complete including taking old security lights fitting any type and description complete all as specified and directed.
S&F in repair of bracket made of GI pipe light grade 1.2 Mtr long of size 40 mm bore, bend to shape as per site requirement fixed to pole/wall with flat iron clamp size 40 x 5 mm -02Nos with suitable bolts, Nuts, washers etc including two coats of synthetic enamel aluminium paint over a coat of red oxide primer on exposed surface of mild steel surface complete all as specified and directed.
S&F in repair decorative gate light LED 15 watt globe (conical shape) made up of high grade unbreakable polycarbon material specified and directed.
S & F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp breaking capacity 10 KA ,"B" series complete all as specified and as directed.
S&F in repair of old unserviceable twin core of flexible wire of size 23/0.0076 with PVC medium grade pipe 20mm dia for connection of post top lantern fitting from one junction box to other junction box complete all as specified and directed at site.
S&F PVC insulated Aluminium conductor wire 2 core 4 Sqmm for making connection from storage geyser to industrial / power socket complete including removal of existing old damaged wire complete all as specified and directed at site.
M & L for point wiring for one light/ fan point/call bell /exhaust fan point controlled by one way switch with 1100 volt grade PVC insulated FRLSH 1.5 Sq mm multi stranded copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed FRLSH, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia including clamps, screws gutties/plug etc & sunken anodized pressed sunken boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches fixed with brass screw complete all as specified and directed.
All as per item No. 21 mentioned here-in-before but 1.5 Sq mm for 5 Amp socket outlet on same board with 1.5 Sq mm earth wire complete all as specified and directed.
All as per item No 21 mentioned here-in-before but 1.5 Sq mm for 5 Amp switch socket on independent board with 1.5 Sq mm earth wire complete all as specified and directed.
All as per item No. 21 mentioned here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed.
M & L for surface point wiring for AC point controlled by one 15 Amps switch one way/metal clad industrial socket with 1100 volt grade PVC insulated-unsheathed 4.0 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of 4.0 Sq mm multi stranded FRLSH copper conductor cable PVC insulated-unsheathed, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia including clamps, screws gutties/plug etc with fittings (ISI marked) & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover complete all as specified and directed. Note : Proper coding to be adopted.
S&F switch piano Flush type, single pole, one way ,5/6 amp 240 volts, complete all as specified and as directed.
S&F switch piano Flush type, single pole,15/ 16 amp 240 volts, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 15/16 Amps, flush type complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 3 pin, 5 Amps flush type,universsal complete all as specified and as directed.
S&F Switch socket combination 2 in1, 3 pin,15/16 Amp flush type,universal complete all as specified and as directed.
S&F switch modular single pole one way 6 amp 240 volts,one Module complete all as specified and as directed.
S&F switch modular single pole one way 16 amp 240 volts, one Module complete all as specified and as directed.
S&F Modular socket 6A - 2/3 pin combined two module complete all as specified and as directed.
S&F Modular socket 16A- 2/3 pin combined two module complete all as specified and as directed.
S&F Modular Bell Push 6 Amp , One module complete all as specified and as directed.
S&F bell push flush type 5 amp AC, 230 volts, single pole complete all as specified complete all as specified and as directed. .
S&F in repair electric Bell, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S&F steped type modular fan regulator ,120 W, 1/2 module complete all as specified and as directed. .
S&F Stepped type electronic fan regulator on the existing phenolic laminated sheet complete all as specified and as directed.
S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body complete all as specified and as directed. .
S&F in repair Plug top 15A 240V complete all as specified and directed.
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 4 way complete all as specified and directed by Engr-in-charge.
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 8 way complete all as specified and directed by Engr-in-charge.
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 12 way with complete all as specified and directed by Engr-in-charge.
S&F in repair 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and neutral (SPN) and current carrying capacity 32 Ampwith breaking capacity 10 kA, in the MCB DB with connection testing and commissioning complete all as specified and as directed.
S&F in repair 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles (SP) and current carrying capacity 6 to 32 Amp with breaking capacity 10 kA,in the MCB DB with connection testing and commissioning complete all as specified and as directed.
S&F in repair 415V, 10KA 'B' curve miniature circuit breaker (MCB) of triple poles and neutral (TPN) and current carrying capacity 40 to 100 Amp with breaking capacity 10 kA,in the DB with connection testing and commissioning complete all as specified and as directed.
S & F in repair MCCB, 4 pole, 415 V, thermal magnetic release setting with 100% ICU, 63 Amps with breaking capacity 25 kA, duly ISI marked, complete all as specified and as directed.
S&F in repair MCB DB TPN 4 way with 200 amps 415 V rated copper busbar in sheet steel enclosure, double door type, complete all as specified and as directed.
S & F in repair sheet metal enclosures for DBs when MCBs to be used in vertical tipple pole and neutral (VTPN) double door 415 volts, 4 way, with IP-43 IK-09 protection including 200 Amp rated bus bar and neutral link (ISI marked) and provn of MCCBs, complete all as specified and as directed.
S&F in repair LED bulb of capacity 10 watts lumen out put (950 lm) length 102 mm, dia 56 mm, base cap B22, (ISI marked) complete with all accessories (ISI marked) all as specified & directed by Engr-in-Charge. .
S&F Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as specified and directed.
S&F in repair LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr in Charge.
S&F in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr in Charge.
S&F in repair round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete
M & L for sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm size PVC casing & caping, medium grade ISI marked with all accessories , as required, fixed on surface of wall along with one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing & capping shall be measured as one RM.
M & L for Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia, complete and and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of conduit shall be measured as one RM.
M & L for Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in existing surface/recessed PVC conduit complete and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable shall be measured as one RM.
M & L for Sub main wiring four single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and two run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including existing surface/recessed PVC conduit PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia, complete and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Four runs of 6 sqmm and two run of 6 sqmm cable shall be measured as one RM.
S&F in repair 1100 V grade heavy duty service cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire one twin core cable flat or circular of size 6 sqmm complete all as specified and directed
S&F in repair 1100 V grade heavy duty service cable withPVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 10 sqmm complete all as specified and directed
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as specified and shown in electrical plate No.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate )chamber with RCC 1:2:4 ,type B-1(using 20 mm graded crushed stone aggregate) , 40 mm thick pre cast RCC cover with TMT 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, returning, filling in and removal etc
S&F in repair LED luminaries 600 mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repair Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and such as couplers, lock nuts, saddles, pipe hooks etc.
S&F in repair of 3mm thick phenolic laminated hylam sheet of size 9" X 11" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed. Note: Supply only switches & sockets shall be measured and paid separately.
S&F in repair of 3mm thick phenolic laminated hylam sheet of size 8" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed. Note: Supply only switches & sockets shall be measured and paid separately.
S&F in repair of 3mm thick phenolic laminated hylam sheet of size 5" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed Note: Supply only switches & sockets shall be measured and paid separately.
Supply only switch piano flush type polycarbonate single pole one way 6 Amps complete all as specified and directed .
Supply only switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed
Supply only socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed
Supply only socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified and directed.
M/S GYANITECH ENTERPRISES
Nand Lal and Sons
om suppler
M/S ROHIT CONSTUCTION
ranjit singh
M/S Bhushan Kumar Jain
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .