Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC First Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
4 Dec 2019, 6:00 pmClosed
Superintending Engineer Project Circle Kannur 2
Office of the Superintending Engineer Project Circle Irrigation Kannur 670002
DRIP_KyIP_Construction of Inspection Bunglow Annex and control room building at Peruvannamuzhi dam site
2019_Irrig_302687_2
KL/WRD/DRIP/KyIP/SE/IPC/KNR /6 /NS
Open Tender
Civil Works - Buildings
Item Rate
270 days
Peruvannamuzhi
Please refer Tender documents.
17 documents required · 17 mandatory
₹6,550
Yes
online
₹1.1 L
Yes
Office of the Superintending Engineer Project Ci
3 Jul 2020
4 Nov 2019
7 Dec 2019
4 Nov 2019
4 Dec 2019
4 Nov 2019
19 Nov 2019
Amount
Insepction Bungalow (Annex)
2.32 Clearing grass and removal of the rubbish up to a distance of 50m outside the periphery of the area cleared.
2.8.1. Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan), including dresing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil
2.26.1 Extra for every additional lift 1.5m or part there of in excavation/banking excavated or stacked materials. All kinds of soil.
2.25. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundation etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m.
50.2.25.1. Fillling with contractor's own earth(excluding rock)in trenches, plinth, sides of foundations etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5 m as per direction of site Engineer-in charge.
4.1.8. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level 1:4:8( 1 cement :4 coarse sand: 8 graded stone agggregate 40 mm nominal size)
4.1.3. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level 1:2:4( 1 cement :2 coarse sand: 4 graded stone agggregate 20 mm nominal size)
7.1.1. Random rubble masonry with hard stone in foundation and plinth including levelling up with cment concrete 1:6:12(1 cement: 6 Coarse sand: 12 graded stone aggregate 20mm nominal size) up to plinth level with cement mortar 1:6(1 cement: 6 coarse sand)
60.7.1. DRY RUBBLE MASONRY -Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compectness to lines and levels cost and conveyance of all materials labour charges etc., complete as per direction of departmental officers at site.
5.9.1. Centering and shuttering including strutting, etc, and removal of form for foundations, footings, bases of columns, etc.for mass concrete.
5.9.6. Centering and shuttering including strutting, etc., and removal of form for columns, Pillars, piers, Abutments, posts and struts.
5.9.5. Centering and shuttering including strutting etc., and removal of form for Lintels, beams, plinth beams ,girders bressurmers and cantilevers.
5.9.3. Centering and shuttering including strutting, etc., and removal of form for suspended floors, roofs, landings, balconies and access platform.
5.9.7. Centering and shuttering including strutting, etc., and removal of form for stairs,(excluding landings)except spiral-staircases).
5.9.16.1. Centering and shuttering including strutting, etc., and removal of form for Edges of slabs and breaks in floors and walls under 20 cm wide.
5.9.15. Centering and shuttering including strutting, etc., and removal of form for smalll lintels not exceeding 1.5m clear span,moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
5.1.2. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering,shuttering, finishing and reinforcement-All work up to plinth level 1:1:5:3 ( 1 cement 1.5 coarse sand : 3 granded stone aggregate 20mm nominal size.
5.2.2. Reinforced cement concrete work in walls ( any thickness), including attached pilasters, buttresses,plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc., up to floor five level excluding cost of centering, shuttering, finishing and reinforcement (1:1.5:3( 1cement: 1.5 coarse sand: 3 graded stone aggregare 20mm nominal size).
5.3. Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15 º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:5:3(1 cement:1.5 coarse sand (Zone III):3 graded stone aggregate 20mm nomnal size)
50.5.33.2. Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinfroced cement concrete work, using cement content as per approve design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing andreinforcment, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per directon of Engineer-in-charge . Note: Cement content considered in this item is @330kg/cum. Excess or less cement used as per desing mix is payable or recoverable separately. All work above plinth level upto floor five level.
5.22.6. Steel reinforcement for R.C.C work including straightering, cutting, bending, placing in positoin and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500 D or more.
5.22A.6. Steel reinforcmeent for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level -Thermo-Mechanically-Treated bars of grade Fe-500D or more.
50.6.7.1. Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
50.6.7.2. Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for superstructure above plinth level upto floor two level including all cost of materials, labour charges etc.
6.4.1. Brick work with common burnt clay F.P.S(non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor five level in all shapes and sizes in Cement Mortar 1:4(1 cement : 4 Coarse sand).
9.48.1. Providing and fixing M.S Grills of required pattern in frames of windows etc., with M.S flats, square or round bars etc, including priming coat with approved steel primer all complete fixed to steel windows by welding.
13.1.1. 12 mm cement plaster of mix 1:4( 1cement 4 fine sand)
50.13.1. 9mm cement plastering of mix 1:3( 1cement: 3fine sand) including all cost of materials, labour charges etc.,complete.
13.7.2. 12mm cement plaster finished with a floating coat of neat cement of mix 1:4( 1 cement:4 fine sand)
11.41.2. Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS 15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4(1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete size of Tile 600x600mm.
11.46.2. Providing and laying vitrified tiles in different sizes(thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS 15622 of approved make, in all colours and shades,in skirting, riser of steps over 12mm thick bed of cement mortar 1:3(1 cement:3 Coarse sand), including grouting the joint with white cement and matching pigments etc.,complete size of Tile 600x600mm.
11.40. Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of lst quality conforming to IS. 15622 of approved make in all colours, shades, except white, ivory, grey fume Red Brown, laid on 20mm thick cement mortor 1:4(1cement 4 coarse sand) including pointing the joints with white cement and matching pigments etc.,complete.
11.36. Providing and fixing 1 st quality ceramic glazed wall tiles conforming to IS 15622(thickness to be specified by the manufacturer) of approved make, in all colours, shades except burgundy , bottle green, black of any size as apporved by Engineer-in-charge, in skirting,risers of steps and dados, over 12mm thick bed of cement mortar 1:3(1 cement : 3coarse sand) and joining with grey cement slurry @ 3.3kg per sqm, includng pointing in while cement mixed with pigment of matching shade complete.
8.12. Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm(average) thick base of cement mortar 1:4(1cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc., all complete as specified and as directed by the Engineer-in-charge -A . Flamed finish granite stone slab, Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
50.9.1.1. Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs of dash fastener shall be paid for separately), using good quality Anjili wood /jack wood.
50.9.3.1. Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30mm thick shutters including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction of Engineer-in-charge. Using Anjili/Jack wood.
9.123. Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogeneous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge.
9.124.1. Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mm x 1 mm, painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (Push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5 mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rails of sixe 100mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100 mm x 8 mm complete as per manufacturer's specifications and direction of Engineer -in-charge. Non decorative finish
21.1.1.2. Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.1. Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
9.53. Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6mix(1cement:3 Coarse sand: 6 graded stone aggregate 20mm nominal size)
50.9.15.1. Supplying and fixing 200mm Aluminium aldrop
9.70.2.Providng and fixing IS: 12817 marked stainless steel butt hinges with stainless steel screws etc.,complete 100x58x1.90mm.
9.74.3. Providing and fixing bright finished brass tower bolts(barrel type)with necessary screws etc.,complete 150x10mm.
9.100. 1. Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc., complete 125mm.
10.28. Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
19.7.1.1. Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg): With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
13.37.1. White washing with lime to give an even shade New work (Three or more coats)
13.50.1. Applying priming coat with ready mixed pink of Grey primer of approved and manufacture on wood work(hard and soft wood)
13.61.1. Painting with synthetic enamel paint approved brand and maufacture to give an even shade Two or more coats on new work.
13.60.1. Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
13.46.1. Finishing walls with Acrylic smooth exterior paint of required shade. New work(Two or more coat appolied @1.67 ltr./10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm).
14.41. Providing and fixing 85x42mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts bolts and washers etc.,complete.
16.91.2 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
25.3. Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement
15.2.1. Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge-Nominal concrete 1:3:6 or richer mix (i/c equlvalent design mix).
15.3. Demolishing R.C.C.work manually /by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50metres lead as per direction of Engineer-in-charge.
15.12.1. Dismantling doors, windows and clerestory windows ( steel or wood) shutter including chowkhats, architrave, holdfasts etc., complete and stacking within 50 metres lead of area 3 sq.metres and below.
15.13.2. Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50meters lead of area beyond 3 sq.metres.
15.14.1. Dismaniling wood work in frames, trusses, purlins and raftersupto 10meteres span and 5 meteres height including stacking the material within 50meters lead of sectonal area 40 square centimetres and above .
15.7.4. Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50metres lead as per directiom of Engineer-in-charge. In cement mortar.
Plumbing and sanitary works
17.1.1. Providing and fixing water closet squatting pan(indian type W.C pan) with 100mm sand cast Iron P or S trap, 10 litter low level white P.V.C flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS 7231 with all fittings and fiixtures complete, inlcuing cutting and making good the walls and floors wherever required. White Vireous China Orissa pattern W.C pan of size 580x440 mm with integral type foot rests.
17.2.1. Providing and fixing white vitreous china pedestal type water closet(European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern,including flush pipe, with manually controlled device (handle lever), conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C.pan with ISI marked white solid plastic seat and lid.
17.7.2. Providing and fixing wash basin with C.I brackets, 15mm c.P brass pillar taps,32 mm c.P.brass waste of standard pattern, including painting of fittings and brackets cutting and making good the walls wherever require white Vitreous china wash basin size 630x450mm with a single 15mm C.P brass pillar tap.
50.18.8.9.2. Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
50.18.9.9.2. Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
50.18.9.19.2. Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
50.18.9.17.2. Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall
50.18.8.7.2. Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2
50.18.7.6.1. Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kgf/cm - Internal work- Exposed on wall
50.18.7.5.2. Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6Kgf/cm2 - Internal work - Exposed on wall
50.18.7.4.2. Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall
50.18.8.3.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
50.18.9.20.4. Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
50.18.9.20.6. Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee
50.18.9.20.7. Providing and fixing PVC moulded fittings/accessories for rigid PVC pipes, includng jointing with PVC solvent cement -63mm dia vent cowl.
50.18.9.22.2. Providing and fixing PVC moulded fittings/accessories for rigid PVC pipes, includng jointing with PVC solvent cement 110mm dia 45 degree Elbow.
50.18.9.22.3. Providing and fixing PVC moulded fittings/accessories for rigid PVC pipes, includng jointing with PVC solvent cement 110mm dia Door Elbow.
50.18.9.22.4. Providing and fixing PVC moulded fittings/accessories for rigid PVC pipes, includng jointing with PVC solvent cement 110mm dia bend.
50.18.9.22.5. Providing and fixing PVC moulded fittings/accessories for rigid PVC pipes, includng jointing with PVC solvent cement 110x110x110mm dia Tee.
50.18.9.22.6. Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110x110x110 mm dia Door tee.
50.18.9.22.9. Providing and fixing PVC moulded fittings/accessories for rigid PVC pipes, includng jointing with PVC solvent cement -110mm dia offset.
50.18.9.22.11. Providing and fixing PVC moulded fittings/accessories for rigid PVC pipes, includng jointing with PVC solvent cement -110mm dia socket /coupling.
50.18.9.22.8. Providing and fixing PVC moulded fittings/accessories for rigid PVC pipes, includng jointing with PVC solvent cement -110mm dia vent cowl..
50.17.1.1. Supplying and fixing stainless steel scap dish including cost of materials and labour charges etc.,complete as per the direction of site Engineer-in -charge.
50.17.1.3. Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc, complete as per the direction of site Engineer-in-charge.
50.17.1.4. Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc., complete as per the direction of the Engineer-in -charge.
17.31. Providing and fixing 600x450 mm beveled edge mirror of superior glass ( of approved quality) complete with 6mm thick hadrd board ground fixed to wooden cleats with C.P brass screws and washers complete.
18.16.1. Providing and fixing brass stop cock of approved quality 15mm nominal bore.
18.22.2. Providng and fixing C.P brass shower rose with 15 or 20mm inlet 150mm diameter.
18.51.1. Providing and fixing C.P brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690gms 15mm nominal bore.
18.17.2. Providing and fixing gun metal gate valve with C.I wheel of approved quality (screwed end) 32 mm nominal bore.
18.17.3. Providing and fixing gun metal gate valve with C.I wheel of approved quality (screwed end)40mm nominal bore.
18.17.4.Providing and fixing gun metal gate valve with C.I wheel of approved quality (screwed end) 50mm nominal bore.
CONTROL ROOM
2.31. Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
2.6.1. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas(exceeding 30cm in depth, 1.5m inwidth as well as 10 sqm on plan) includng disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed . All kinds of soil.
2.8.1. Earth work in excavation by mechancial means(Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m including getting out the excavated soil and disposal of surplus excavted soil as directed, within a lead of 50m. All kinds of soil.
4.1.8. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level 1:4:8(1cement:4 Coarse sand : 8 graded stone aggregate 40 mm nominal size).
7.1.1. Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12( 1 cement: 6 coarse sand: 12 graded stone aggregate 20mm nominal size) up to plinth level with cement mortar 1:6 (1 cement : 6 coarse sand)
4.3.1. Centering and shuttering including strutting propping etc., and removal of form work for foundations, footings, bases for columns.
5.9.6.Centering and shuttering including strutting etc., and removal of form for Columns, Pillars, Piers Abutments, posts and struts.
5.9.3. Centering and shuttering including strutting, etc., and removal of form for suspended floors, roofts, landings, balconies and access platform.
5.9.16.1.Centering and shuttering including strutting, etc., and removal of form for Edges of slabs and breaks in floors and walls under 20cm wide.
5.9.5. Centering and shuttering including strutting, etc., and removal of form for Lintels, beams, plinth beams,girders bressumers and contilevers.
5.9.7. Centering and shuttering including strutting, etc., and removal of form for stairs, (excluding landings) except spiral-staircases).
5.1.2. Providng and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level 1:1:5:3( 1cement 1.5 coarse ssand 3 graded stone aggregate 20mm nominal size.
2.25. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundation etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m.
5.2.2. Reinforced cement concrete work in walls(any thickness),including attached pilasters, bultresses, plinth and string courses, filllets, columns, pillars, piers, abutments, posts and struts etc, up to floor five level excluding cost of centering, shuttering, finishing and reinformcenet 1:1.5:3( 1 cement, 1.5 coarse sand, 3graded stone aggregate 20mm nominal size).
5.3. Reinforced cement concrete work in beams, suspended floors, roofs, having stope up to 15 º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttreing,finishing and reinforcement with 1:1.5:3(1 cement, 1.5 coarse sand(Zone III) 3 graded stone aggregate 20mm nominal size)
5.5. Reinforced cement concrte work in arches, archribs, doms, vaults, shells,folded plate and roofs having slope morethan 15 up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3( 1cement ,1.5 coarse sand(Zone III) 3 garded stone aggregate 20mm nominal size).
5.22.6. Steel reinformcent for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of garde Fe-500D or more.
12.20.Providing and laying pressed clay tiles ( as per approved pattern 20mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4( 1cement, 4 coarse sand mixed with 2% integral water proofing compound, laid over a bed of 20mm thick cement mortar 1:4 ( 1cement: 4 coarse sand) and finished neat complete.
50.6.7.2. Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials,labour charges etc.
6.3.1. Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS.2222 in superstructure above plinth level up to floor five level in cement mortar 1.6(1 cement: 6coarse sand) with F.P.S(non modular) bricks.
13.1.1. 12mm cement plaster of mix 1:4(1cement 4 fine sand)
13.16.1. 6mm cement plaster of mix 1:3( 1cement 3 fine sand).
13.46.1. Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.83.2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour. Two coats
13.37.1. White washing with lime to give an even shade: New work (three or more coats)
11.41.1. Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm.
11.46.1. Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 500x500 mm
11.36. Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.40. Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
10.28. Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
10.3. Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
9.48.1. Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
21.1.1.1. Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
10.5.1. Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
13.84.2Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats.
11.20.1. Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement
Rain Water Harvesting Tank
2.31. Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1. Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil
2.26.1. Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soils
2.25. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8(1 cement:4 coarse sand:8graded stone aggregate :40 mm nominal size
5.1.2. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1.5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.2. Centering and shuttering including strutting, etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
5.22.6. Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
13.9.1Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
50.18.9.19.2Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in -charge 110m dia 4 kgf/cm2-External work-Exposed on wall.
85.106. Supply of MS flats including cost of conveyance charges.
ELECTRIFICATION OF TWO BUILDINGS
90.2.1.1 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.2 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Twin Control light point with 6A, plate ceiling rose - Short point
90.2.1.3 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials nforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.4 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
90.2.1.5 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Call bell pointwith 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point
90.2.1.13 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main a d continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories)Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
90.2.2.7 Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Independent plug - Short point
90.3.20.3 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.21.3 Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
od12020/2019_2020 Supply, conveyance, installation , testing and commissioning of Wall dena Fancy wall bracket in working on 230V single phaseA/C. fixing on wall with suitable bolt & nut as required including giving connections with required quantity of flex wire
od12022/2019_2020 Supply, Conveyance, installation and testing of Mirror light Fixture with anti glare diffuser and decorative end caps suitable for 5 W LED (Havells make Viva or equalent) directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
od11855/2019_2020 Supply,Conveyance, installation, testing and commissioning of 20 W, 2000 lumen LED, IP 65 street light fitting with aluminium housing, duly wired up for use on 230 V AC supply in the existing GI pipe and giving connections as required.
90.3.18.1 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
od11856/2019_2020 Supply and Fixing the 200 plastic shade in the existing front fitting and giving necessary connections as required <br>
od11857/2019_2020 Supply and fixing Backelite batten straight/ angle holder including connection etc. as required
od11902/2019_2020 Supply, conveyance, installation, testing and commissioning of cast aluminium stove enameled elliptical shaped bulk head fittings directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required.
od11858/2019_2020 Supply and providing the 9W LED lamp in the existing fiting as required.
90.4.5.2 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.2 Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
od11859/2019_2020 Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. - 300/ 305 mm, single phase light duty exhaust fan in metal frame.
90.5.1.11 Bell indicator without box and cover
1.22.2 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.100 mm X 100 mm X 60 mm deep
90.5.1.3 Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
90.5.1.4 Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required. Musical bell with bird sound
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
od11860/2019_2020 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.<br>32A DP switch with indicator modular
90.11.1.10 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP42/43)
90.11.1.19 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.14.10.4 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.11.1.18 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
od11862/2019_2020. Supplying and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.<br>20 mm
od11863/2019_2020 Supplying and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.<br>25 mm
1.17.4 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
1.17.2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.13 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.17.20 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.22 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
90.12.7.42 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.7.41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.40 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.5.41 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
90.12.5.32 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 120 sq mm
90.12.10.5 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation90/75 mm or nearest size
90.12.10.3 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
od11864/2019_2020 Supply and drawing 2.00mm dia bare copper conductor through existing conduit / along with wiring as required<br>
od11865/2019_2020 Supply, providing and fixing 2.65 mm (12SWG) dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
od11866/2019_2020 Supply and drawing 3.15mm dia bare copper conductor through existing conduit / along with wiring as required
od11867/2019_2020 Supply of superior quality 2.00mm (14SWG) copper earth socket and including crimping etc. as required.
od11868/2019_2020 Supply of superior quality 2.65mm copper earth socket and including crimping etc. as required
od11869/2019_2020 Supply of superior quality 3.15mm copper earth socket and including crimping etc. as required
od11870/2019_2020 Supply and providing 12x3mm brass nut and bolt etc. as required.
od11871/2019_2020 Supply and providing 25x6mm brass nut and bolt etc. as required
od11872/2019_2020 Earthing as per IS 3043 with G.I./C.I. earth plate 600 mm X 600 mm X 6 mm with 20 mm GI watering pipe of 2 metre long fixed to the earth plate with 20 x 3 mm GI clamps, including all accessories, andproviding masonry enclosure with cover plate having locking arrangement etc. with charcoal/ coke and salt but excluding test joint, earth continuity conductor to the plate, and covering at the top as required (in ordinary soil).
od11873/2019_2020 Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
od11874/2019_2020 Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
od11875/2019_2020 supply and Providing and fixing following capacity TP&N disconnector fuse switch unit in sheet enclosure with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.<br>63 Amp TP & N (Front Handle)
od11876/2019_2020 Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6535) and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required.
od11877/2019_2020 Supplying and fixing 63 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
od11878/2019_2020 Supplying and fixing 63, HRC Fuse with HRC Fuse link with connections, in existing meter board
14.6 Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
14.7 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required
od12513/2019_2020 Charges for shifting the existing panel board to newly constructed control room
od12511/2019_2020 Charges for shifting the 62.5KVA DG set to newly constructed control room
od11883/2019_2020 Supply and providing the following size of B class MS pipe conforming to relevant IS specifications complete with heavy guage specials such as bends, flanges etc welded and fixed at appropriate locations, providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flange etc with 2 coats of heat resistant paint suitable for outdoor applications, fixing the pipe firmly with fabricated structure/wall/any other mechanical support etc as required.- 50 mm dia B class MS pipe as extended exhaust pipe.
od12515/2019_2020 LS - fee to be paid to electrical inspectorate (Actual amount incurred for the above items will be reimbursed on production of original documents)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_437330.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .