| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹42.8 L+₹15.6 L (57.6%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹52.5 L+₹25.4 L (93.5%)Rejected-Finance 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
3 Oct 2023, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N Area Pin-160003
REPAIR AND MAINT OF CI/DI/GI AND REPLACEMENT OF OLD CORRODED WATER SUPPLY PIPE LINES, SUPPLY MAIN ETC. AT N AREA AND HALLOMAJRA INCLUDING REPAIR AND MAINT OF EXTERNAL WATER SUPPLY, AT DAD COLONY SECTOR 35B AND PCDA COMPLEX SECTOR 09 UNDER GE CHD
2023_MES_616986_1
GE/CHD-50/2023-24
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
Class D category a(ii) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹93,000
Yes
1 Dec 2023
2 Sept 2023
5 Oct 2023
2 Sept 2023
3 Oct 2023
21 Sept 2023
2 Sept 2023 - 10 Sept 2023
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 25 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 40 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 50 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 90 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 110 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
M&L DI pipe 200 mm (certifugally cast) class 'K-7' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint) as per IS- 1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified .
M&L DI pipe 150 mm (certifugally cast) class 'K-7' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint) as per I.S- 1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified .
M&L DI pipe 100 mm (certifugally cast) class 'K-7' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint)as per IS- 1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified .
M&L DI pipe 80 mm (certifugally cast) class 'K-7' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint)as per IS-1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified .
Supply and fixing of CI/DI fittings of size up 150 mm bends ( any radius and angle ) Tapers any type,( straight, bend , increasing,decreasing or double socket etc)Tee pieces single branch. `Y` junction , double branch cross ( all socket or socket and spigot/ flanged as required at site) collars, caps and plugs etc.,complete all as specified.
Rubber gasket joint for 100 mm dia CI flanged pipe complete all as specified
Rubber gasket joint for 150 mm dia CI flanged pipe complete all as specified
Rubber gasket joint for 200 mm dia CI flanged pipe complete all as specified
Supply and fix Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & rubber insertion packing etc for 200 mm bore pipe and fixed, in repairs, complete all as specified.
Supply and fix Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & rubber insertion packing etc for 150 mm bore pipe and fixed, IN REPAIRS, complete all as specified.
Supply and fix Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packing etc for 100 mm bore pipeand fixed, IN REPAIRS, complete all as specified.
Supply and fix Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packing etc for 80 mm bore pipe and fixed, IN REPAIRS, complete all as specified.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm dia, in repairs , complete all as specified.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 40mm dia, in repairs , complete all as specified.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm dia, in repairs , complete all as specified.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm dia, in repairs , complete all as specified.
S&F Cast iron Non return valve of 150 mm dia with provn of two end spoigot and socket suitable for rubber tyton joint and one end flanged fixed with removable MS plate incl ,rubber gas kit,nut,bolt ,washers,and making suitable fixing arrangement to DI 150 MM dia pipe etc complete all as specified . Note : Fitting will be measured and paid separetly, if any, required
S&F Cast iron Non return valve of 100 mm dia with provn of two end spoigot and socket suitable for rubber tyton joint and one end flanged fixed with removable MS plate incl ,rubber gas kit,nut,bolt ,washers,and making suitable fixing arrangement to DI 100 MM dia pipe etc complete all as specified . Note : Fitting will be measured and paid separetly, if any, required.
S&F 100 mm bore cast iron Air release valve with two air outlets complete with fixing arrangement, as in repair complete all as specified and as directed by Engineer-in-Charge.
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 150 mm to 300 bore ,including excavation through Men/Mechanical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) , DI / CI fitting and pipe length) will be measured and paid saperately under appropriate item of sch 'A' herein. (iii) Cost of new pig lead/lead wool required for repair of leakages is deemed to be included in the quoted rates.
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 80 mm to 100mm bore ,including excavation through Men/Mechnical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) , DI / CI fitting and pipe length) will be measured and paid saperately under appropriate item of sch 'A' herein. (iii) Cost of new pig lead/lead wool required for repair of leakages is deemed to be included in the quoted rates.
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 200mm to 300 bore ,including excavation through Men/Mechnical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) Jointing material and pipe length will be measured and paid saperately under approriate item of sch 'A' herein.
Arresting of water leakage from existing pipe line in position from GI pipe of size 40mm to 50mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Arresting of water leakage from existing pipe line in position from GI pipe of size 15mm to 25mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified. Note:- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Locating blockage in existing distribution pipeline 80mm dia any type in position by excavation work manualy in any type of soil upto 750x500mm upto max 2Mtr length at various location ( Maximum up to 3 location ) incuding necessary cutting/threading/welding work & provision of required size of fittings such as union/socket 1no ,replacement of damaged pipeline,returning filling and removal of surplus soil complete all as specified . Note :- (i) Pipe length will be measured and paid saperately under approriate item of sch 'A' (ii) Contractor shall restore supply system within in 8Hrs.
Locating blockage in existing distribution pipeline 40/50mm dia any type in position by excavation work manualy in any type of soil upto 750x500mm upto max 2Mtr length at various location ( Maximum up to 3 location )incuding necessary cutting/threading/welding work & provision of required size of fittings such as union/socket 1no ,replacement of damaged pipeline,returning filling and removal of surplus soil complete all as specified . Note :- (i) Pipe length will be measured and paid saperately under approriate item of sch 'A' (ii)Contractor shall restore supply system within in 8Hrs.
S&F Run lead joint for 150 mm pipe complete all as specified .
S&F Run lead joint for 200 mm pipe complete all as specified .
S&F Run lead joint for 100 mm pipe complete all as specified .
S&F Run lead joint for 80 mm pipe complete all as specified .
Construction of valve pit chamber of size 120 x120 x120 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified
Construction of valve pit chamber of size 90 x90 x90 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified
S&F Rotational moulded polye- thylene water storage tanks of capacity 2000 Ltrs (cylindrical vertical with closed top) 3 layered, hoisted and fixed in position complete including 25mm float valve specified in SSR Part I
S&F Ball brass valves 25 mm dia , high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed →
Cutting of existing cast iron pipe of 150 mm bore for insertion of new tees & branch line of any bore in position including welding complete and all as specified
Cutting of existing cast iron pipe of 100 mm bore for insertion of new tees & branch line of any bore in position including welding complete and all as specified
S&F Tubes 20 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
S&F Tubes 25 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
S&F Tubes 40 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
S&F Tubes 50 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
Cutting and threading existing 15 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) .complete all as directed by the Engineer- in-Charge.
Cutting and threading existing 20 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured)complete all as directed by the Engineer- in-Charge.
Cutting existing 25 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured).complete all as directed by the Engineer- in-Charge.
Cutting existing 40mm to 50 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) complete all as directed by the Engineer- in-Charge.
M&L for sand filling using approved clean dry sand for cushioning of under ground cables incl spreading levelling and well ramming in layers not exc 25cm
Supply and laying of class B brick for under ground cable protection as directed by Engineer - in - Charge.
S&F Tubes 15 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 25 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 40 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 50 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Re-fixing old steel tubes and connections of size 15 mm bore in new or old position (walls, ceilings, floors/trenches etc.) complete all as specified. NOTE: GI tube taken down under serial item No 56 shall be fixed under this item.
Re-fixing old steel tubes and connections of size 20 mm bore in new or old position (walls, ceilings, floors/trenches etc.) complete all as specified. NOTE: GI tube taken down under serial item No 57 shall be fixed under this item.
Re-fixing old steel tubes and connections of size 25 mm bore in new or old position (walls, ceilings, floors/trenches etc.) complete all as specified. NOTE: GI tube taken down under serial item No 58 shall be fixed under this item.
DI pipe 150 mm (certifugally cast) class 'K-9' (ISI Mark) in any length with spigot and socket ends as per is 1536-2001 jointed ie rubber tyton joint and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified
DI pipe 100 mm (certifugally cast) class 'K-9' (ISI Mark) in any length with spigot and socket ends as per is 1536-2001 jointed ie rubber tyton joint and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified
Run lead joint including replacement of bolts, nuts & washers for 100mm bore CI pipe /joints, fixing and testing after completion complete all as specified .
Construction of valve pit chamber of size 1000X1000X100MM with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified
Locating blockage in existing distribution pipe line 25/40mm dia any type in position by excavation work manualy in any type of soil upto 750x500mm upto max 2Mtr length at various location. ( Maximum up to 3 location) incuding necessary cutting/threading/welding work & provision of required size of fittings such as union/socket 1no ,replacement of damaged pipeline,returning filling and removal of surplus soil complete all as specified . Note :- (i) Pipe length will be measured and paid saperately under approriate item of sch 'A' (ii) Contractor shall restore supply system within 8Hrs.
Dismantling to existing unserviceable submersible pump motor of 15HP, 3Phase, 440Volt, 50HZ and Rewinding to stator with PVC insulated copper winding wire including sleeves, thimble & minor spare parts like as bronze bushes, gland packing etc and Re-assembling to the same after motor after repair work . Complate all as specified and as directed by Engineer -in - Charge.
All as per above No 69 here in before but for Submersible motor of 12.5 HP
Supply/repair and fix for motor bearing bush (Set of five) for Submersible pump 15HP complete all as specified and as directed .
All as per above No 71 here in before but for Submersible motor of 12.5 HP
Supply/repair and fix for stainless steel shaft suitable for submersible pump 15HP complete all as specified and as directed
All as per above No 73 here in before but for Submersible motor of 12.5 HP
Supply/repairb and fix for Impeller suitable for submersible pump 15 HP complate all as specified and as directed by engineer in charge.
All as per above No 75 here in before but for Submersible motor of 12.5 HP
Supply/repair and fix for bearing bush suitable for submersible pump 15 HP complate all as specified and as directed by engineer in charge.
All as per above No 77 here in before but for Submersible motor of 12.5 HP
Dismantling to defective induction motor with centrifugal pump set of 50HP, strip opening, taking out old burnt winding wire from stator carefully, cleaning the stator slots carefully, Re-winding to stator with copper winding wire as per exiting size of wire including providing mica paper in stator slots thimbles, vanishing to winding wire and assembling to motor after repair work including testing to motor at work shop complete all as specified and as directed by Engineer - in - charge. NOTE :- Defective spare parts, bronze bushes etc shall be measured & paid separately but fixing charges shall be deemed to be included in the unit rate of this item. nothing extra shall be entertained on this account.
Supply/repair and fix ball bearing as per existing size for motor complete all as specified and as directed by Engineer - in - charge.
Supply/repair and fix ball bearing as per existing size for centrifugal pump set complete all as specified and as directed by Engineer - in - charge.
S&F in repair PVC insulated, unsheathed copper conductor cable 10Sqmm, 3Core, Suitable for submersible pump motor complete all as specified and as directed.
Disconnection and removing the unserviceable spare kit of Power contactor 3 pole, 440 volts and supply and fix new spare kit unit suitable for MNX-32 Power contactor complete all as specified and as directed by Engineer - in - charge.
All as per item No 83 here-in-above but of capacity MNX-A2 Power contactor
Supply and Fixing relay capacity of 28 to 32Amp complete all as specified and as directed by Engineer - in - charge.
Supply and Fixing single phase preventer complete all as specified and as directed
Supply and fix ON Load change over switch 415 volts in sheet metal enclousers 3 pole of capacity 125 Amps complete all as specified and directed.
Supply and Fixing 10KVAR, 3Phase, 440Volt complete all as specified and as directed
Disconnection and removing the U/S Automatic star/delta starter and S & F Automatic star/delta starter in SS enclosure with relay max range 30-40 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
Disconnection and removing the U/S Automatic star/delta starter and S & F Automatic star/delta starter in SS enclosure with relay max range 18 to 25 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
Disconnection and removing the U/S Automatic star/delta starter and S & F Automatic star/delta starter in SS enclosure with relay max range 9 to 14 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
Disconnection and removing the U/S Automatic star/delta starter and S & F Automatic star/delta starter in SS enclosure with relay max range 7 to 10 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
HRC fuse for 415 volt, 63 Amp rating HF type complete all as specified and as directed
Indication Lamp set of 3 for RYB & N complete all as specified and as directed
M & L for Outdoor type Straight through ,jointing kit,cold shrinakable for 11KV grade UG cable 120 Sqmm 3 core Aliminium conductor complete along with jointing material all as specified and as directed by Engr in Charge
M & L for Indoor type jointing kit cold shrinakable for 240 Sqmm 3.5 Core 1100 Volts grade LT UG cable end termination with 3.5 /4 Core Aluminium conductor complete along with jointing material all as specified and as directed
Taking down of LT XLPE/ PVC UG cable 1100 V grade, 240 Sqmm 3.5 core from the trenches along with cable protection covers/bricks , sand care fully for finding out the fault and relaying the same in the trenches after Repairs in the same trenches along with the existing sand , PCC covers/Bricks complete all as directed by Engineer - in charge. Note : - Excavation, RFR & removing of excavation spoil will be measured and paid seperately under the respective items Note 2:- Unserviceable LT Cable replaced with new cables will be measured and paid seperately Note3:- PCC Cover/bricks and sand protection required for addtional loops of LT cable straight through joints will be measured and paid seperately under the respective items. Note4 : - Excavation,RFR,Sand cushioning, cable protection covers and joints required for additional loops and re-routing of cables will be measured and paid seperately.
All as per Item No 97 here in above but of 120 sq.mm 3.5 core
All as per Item No 97 here in above but of 95 Sqmm 3.5 Core
All as per Item No 97 here in above but of 50/35/25 Sqmm 3.5 Core
Supply, laying in trenches or fixed to poles or passing through pipes and testing cable XLPE Insualted screened PVC bedded, galvanised steel strip or wire armored, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core complete all as specified and directed. Note:- 1. Excavation, earth work, sand cushioning, and brick protection shall be measured and paid for separately. 2. Rate of necessary lugs, thimbles and jointing material shall be included in unit rate.
All as per Item No 101 here in above but of 120 sq.mm 3.5 core
All as per Item No 101 here in above but of 95 Sqmm 3.5 Core
All as per Item No 101 here in above but of 50 Sq.mm 3.5 core
All as per Item No 101 here in above but of 35 Sqmm 3.5/ 4 Core
All as per Item No 101 here in above but of 25 Sqmm 3.5/ 4 Core
Disconnecting and removing u/s ACB and S&F ACB 4 Pole 800 Amp,415V, microprocess release with breaking capacity 50KA, 50 to 60 HZ complete all as specified and as directed.
Supply and fix in repair CT/PT 800/05 400Amp Complate all as Specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mmX600mmX6mm thick buried drectly in ground Verticaly to a depath not less than 2.25mtr deep below normal ground level with top edge of earth plate at a depth of not less than 1.5mtr below normal ground level connected to galvanized iron strip 32mmX6mm by means of bolts, nuts, check nuts and washers made out of galvanized iron and GI earth strip protected by 40MM bore light grede GI Pipe as well as 20mm dia medium grade pipe 1.5mtr fixed with funnel and wire mesh as Specified and connected allas shown in electrical plate No 03 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B-1 in chamber and 40mm thick 1:2:4 type B-1 cover slab with 6mm dia mield steel bars at 100mm center to center both way with 6mm dia MS hoks Complate all as Specified and as directed.
Supply & fix Indoor Type LT panel board outdoor type double door wall mounted made out of 3mm thick CRCA sheet Steel for load bearing and 2 mm thick for non load bearing and portions mounted on frame angle iron fo suitable size weather proof/veermin proof shutter type with locking arrangment of cubical type prewired with aluminium extendable busbar 125 Amps for 03 phases and aluminium busbar 125 Amps for neutral including suitable CTs etc and powder coated paited, agle iron frame base (90CMX75CMX30CM) with provision for fixing of MCCB's mounting arrangement shall be adjustabile type,Comprising of following complete all as specified. Make of the Panel board confirming to CPRI specifications only. (i) MCCB 125 Amps, Breaking capacity 35 KA, 4 pole -1 No (In coming) Make: legrand(ii) 4Nos Aluminium Bus bar of Capacity 125 Amps for Phase & Neutral (iii) MCB SP 6-32 Amp - 40 N0s (out going) Make - legrandiv) LED/Neon indicator bulb in RYB Colour - 1 Set.
M&L for cleaning of underground sump water storage tank of approx 12mtr dia and depth 3.3mtr by dewatring the tank by providing suction pump, scraping internal surface of tank with wire brushes and removing all scale/dirt/deposited silt, washing internal surface of tank with solution of bleaching powder and one coat of white wash to internal surface of walls complate all as specified and as directed. NOTE:- (i) Removing of honey bee hives shall be the responsibility of the contractor. no additional charges shall be admissible on this account. (ii) Contractor shall be responsible for making all safety arrangement, dewatering pump, T&P etc Complate all as Specified and as directed.
Supply & fix Solar water tank made out of stainless steel alongwith PUF insulation of capacity 100 ltrs with electrical heating backup of 2 KW including taking down old U/S solar water tank Complate all as Specified and as directed.
M/s Friends Engineering Works
Alpha Engineers and Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .