| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | ₹12.9 L | L1 | Accepted-AOC first lowest bidder below ER |
| 2 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance EMD exemption certificate not valid |
| Sl No | Description | Qty | Unit | ATLAS ELEVATOR INDIA PVT LTD L1 |
|---|---|---|---|---|
| 1.00Electrification. | ||||
| 1.00 | OD344150/2025-2026: Supply, Installation,Testing and Commmissioning of Bed Cum 12 passenger bed Lift 1.0 m/sec ,3floors and 3stops without machine Room. Following specification including all required standard features are 1 .Type of Lift: Bed cum 12 Passenger capacity Gearless with Machine room type 2. Load / Persons :884 Kg. / 12 persons 3 .Rated speed :1M/Sec. 4. Travel :10 Mtr ( Approx) 5. No. of floor and entrance served: 3 stops and 3openings 6. No. of floor served :Three floors 7. Method of control : Micro processor based Simplex selective collective system (Monarch), AC VVVFDrive (Monarch) 8. Location of machine room: above lift well 7.5 HP,254 RPM,PMS motor(MONODrive/Montanary) 9. Size of lift well :1750mm (width ) X 2300 mm (depth ) 10. Car size: 1050 mm (width) x 1900mm (Depth ) 11. .Leveling accuracy : As per IS 12. Cardoor opening : As per IS 13. Drive : Variable voltage variable frequency(V3F) 14 .Operation : Simplex full selective collective control with ON/OFF switch 15. Construction of design and furnishing of car body work: Stainless steelHairline Finish. 16.Pit Depth Required : 1500mm 17. Electric supply : 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 19. 7- Segment Display Car indicator & landing indicator: To be provide for entire length of the door 20. Automatic Rescue Device :Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four rescue operation . The rescue operation should act within 10 seconds of power failure 21. Regulation :350V-450V (SMPS based) 22. Indication in the car : a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Non stop button g) Battery operaemergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Fireman's switch at main lobby i) Auto attendant control (inside the car) 23. Winding handle Manual winding handle for use in emergency. 24. Safeties a) Over speed governor, operated safety gear b) Buffers c) Motor over load protection d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventer g) Final limit switch 25. Leveling Automatic leveling at all landing as per IS 26. Guarantee: Company shall carry out free maintenance during warranty period which also includes a) Cleaning lift equipment b) Replacing /rewinding of all defective parts of the lift including motors and V3F unit. 27. Control panel :Control panel will be dust and vermin proof of sheet metal enclosure 28. Announcement System: To provide lift announcement system 29. Tests :At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 30. Scope of work:- a) Supply of lift materials
b) Intercom facilities with one master and two slaves c) Battery operated alarm d) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. Necessary fee shall remitted to the Inspectorate by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. e) Supply of book let with complete details of maintenance schedule and control diagram. f) Giving training to department staff for attending trouble shooting | 1 | set | 12,73,000 ₹12.7 L |
| 1.00 | 90.2.2.1:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | 3 | point | 718 ₹2,154 |
| 1.00 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | 3 | each | 375 ₹1,125 |
| 1.00 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | 3 | each | 175 ₹525 |
| 1.00 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | 3 | each | 226 ₹678 |
| 1.01 | 1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm | 16 | metre | 200 ₹3,200 |
| 1.01 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door | 1 | each | 2,600 ₹2,600 |
| 1.01 | OD344147/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x3mm brass nut and bolt . | 6 | no | 15 ₹90 |
| 1.01 | OD344148/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x6mm brass nut and bolt . | 8 | no | 19 ₹152 |
Tender Value
₹13.3 L
EMD Value
₹33,173
Closing Date
31 Oct 2025, 4:00 pmClosed
ASSISTANT ENGINEER
O/o THE ASSISTANT EXECUTIVE ENGINEER, LID AND EW SUBDIVISION CHALAKUDY BLOCK PANCHAYATH P. O. CHALAKUDY -680 307
Electrification
2025_LSGD_813505_1
13/AE/LID EW/CKDY/2025
Open Tender
Electrical Works
150 days
KODASSERY GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹33,173
Yes
24 Feb 2026
23 Oct 2025
3 Nov 2025
23 Oct 2025
31 Oct 2025
23 Oct 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1360249.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
PA.pdf
Tender Documents • 0.16 MB
FOT.pdf
Tender Documents • 0.15 MB
AFFIDAVIT.pdf
Tender Documents • 0.14 MB
IP.pdf
Tender Documents • 0.14 MB
BOQ_1360249.xls
BOQ • 0.31 MB
viewsbd.pdf
Tender Documents • 0.59 MB
EPAY.pdf
Additional Documents • 0.14 MB
Download all tender documents and submit your bid