Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹18.9 L
EMD Value
₹37,700
Closing Date
26 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
eo
nagar palika mandhan
Supply of octangle pole with led lights and hismast laight work at mandhan
2026_DLB_604333_1
NPM/2026-27/1173
Open Tender
Miscellaneous Services
Percentage
180 days
mandhan
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
as per nit
₹37,700
Yes
17 Oct 2026
17 Oct 2026
27 Oct 2026
17 Oct 2026
26 Oct 2026
17 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Laying and Jointing PVC Pipe. Heading | |||||
| 1.01 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | 300 | mtr | 238 | ₹71,400 |
| 1.02 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | 400 | mtr | 357 | ₹1,42,800 |
| 1.03 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR | 8 | nos | 15,523 | ₹1,24,184 |
| 1.04 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure | 120 | mtr | 238 | ₹28,560 |
| 1.05 | Supply installation testing & Commissioning of high mast lighting
system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK
/IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally
hot dip galvanised by piecewise single dipped method high mast,
lantern carriage suitable for up to 12 nos luminaries with welded arm
(excluding luminares), mast head frame assembly with full cover,
including 1 No. LED 15 Watts aviation obstruction lights, double
drum type self sustaining winch, integral power tool accesible from
door with padlocking arrangement (winch motor with control circuit)
hot dipped galvanised heavy duty pipe lightening finial, Stainless
steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope
for lantern carrage & 2 no. rope for winch assembly ) foundation bolt,
torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm
trailing cable, including outdoor type control panel for auto on / off,
reverse / forward motor operation. The mast is constructed from mild
steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a
polygonal section, telescopic jointed and welding as per BS
5135.etc. as required on Existing Foundation. ( See table P - 03 for
specs.) OEM Must have Type test certificate for wind tunnel test .
All as per pre approved by Engineer in-charge. All as per pre
approved by Engineer in-charge. For additional technical
parameters of products/ work , refer Annexure "A" attached with
this BSR . | 2 | each | 2,94,474 | ₹5,88,948 |
| 2 | Supply and erection of Galvanized Iron pole with galvanizing done
in single dipping (Average coating thickness Minimum 65 Microns)
continuously tapered poles having Octagonal / Circular cross
sections designed to withstand the maximum wind speed as per IS
875, The pole shaft shall be made from sheet steel (HT Steel
Conforming to grade S355JO) and confirming to BSEN 10025 and
shall be continuously tapered with single longitudinal welding. There
shall not be any circumferential welding. The welding of pole shaft
shall be done by Submerged Arc Welding (SAW) process. pole
shafts shall be provided with the rigid flange plate of suitable
thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for
fixing 4 no. foundation bolts, This base plate shall be fillet welded to
the pole shaft at two locations i.e. from inside and outside.The
octagonal Poles shall have lockable door of approximate 500 mm
length at the elevation of 500 mm from the Base plate with bakelite
sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos)
inside the pole at door opening for cable connection of following
length and dimension as per table P-01 with base plate and
foundation bolt on the Existing | 1 | each | 19,456 | ₹19,456 |
| 3 | Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
A) Excavation of Pit for Foundation Size upto required depth from Ground level
B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.
C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness
D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.
E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal
F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.
G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.
H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face | 33.45 | each | 21,993 | ₹7,35,665.85 |
| 4 | Providing & Fixing of IK08 IP-66 protected high power LED flood
light system with single piece Pressure diecast aluminium housing,
toughened glass diffuser with suitable lenses on LED to achieve
various beam angles, of high power LED of 3 to 5 watt each .
Integrated potted driver as a unique BIS R number having efficiency
more than 85 % and in compliance to BIS certified and Trade mark
certificate. The System level Luminaire efficacy >=125 lm/ wt. LED
driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff
@>=300 V AC and Auto resetting Safety .Power Factor >0.95 ,
THD(I) <10% , driver current <=750mA. driver should be Phase to
phase protection of 440 V for 4 Hrs. Electrical Connector , Surge
Protection Min >=4KV internal and 10KV external but inside driver
compartment, System life of 50000 Burning hours with 70% of Initial
Lumens maintained, CRI>70 and CCT 5700K ±355K.
Manufactures Word Mark/Name Engraved/Embossing/Screen
printing on die cast housing to allow traceability/authenticity. Fixture
shall be IS 10322 Complianced.OEM Must have its own in house
NABL lab setup for all testing facilities for LED fixtures.
(LM79/LM80) Certificate/ report with liable warranty of
product/accessories from OEM shall be submitted. | 70 | mtr | 428 | ₹29,960 |
| 5 | SITC of Cutting back up surface up to 2 Mtr. Depth by digging by Bogie including all layers of crust for laying pipe line etc. and making good to original condition (excluding cost bitumen) | 50 | mtr | 1,184 | ₹59,200 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
BOQ_1071919.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .