Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹4 L
EMD Value
₹8,000
Closing Date
2 Jun 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Mech. irrig. Div. Baramulla
Mech. irrig. Div. Baramulla
Design, supply, installation and commissioning of 200 KVA Voltage Stabilizer and allied works at Vighbal-I LIS of MISD Sopore.
2020_IFC_97273_1
eNIT 13 of 2020-21
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
10 days
Vighbal-1 Sopore
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
Executive Engineer Mech. irrig. Div. Baramulla
₹8,000
Yes
Mech. irrig. Div. Baramulla
4 Jun 2020
27 May 2020
3 Jun 2020
27 May 2020
2 Jun 2020
27 May 2020
30 May 2020
60 days
Amount
Design, Supply, installation, testing and commissioning of 200 KVA manually operated 8/6 steps voltage Stabilizer for Vighbal-I LIS with following broad band specifications: Type of voltage controller: Manually operated copper strip wound, 3 phase & neutral power supply. Type of Regulator: plate type with electrolytic copper contacts. Input Voltage: 150-330V. Output Voltage: 400V. Frequency: 50±3% c/s. Phase imbalance: Imbalanced voltage & frequency characteristics. Winding: Electrolytic grade copper strips of adequate section, vacuum impregnated and oven dried. Insulation: Fiber glass insulation to tested parameter. Efficiency: 98%. Cooling: Natural with convection fins, oil cooled. Mounting: Mounting on uni-directional wheels at four corner. Duty cycle: 100% continuous. Enclosure: M.S sheet 4mm thick in pressed CGR sheet, powder coated duly strengthened with stiffeners of M.S flat/angle. It shall also be provided with a filling nozzle at the top & a drain at the bottom dully plugged. Core laminates: High grade low eddy current loss grain oriented silicon steel laminations. Load: Three phase induction motor load with full load amperage(Max 200& Normal 190Ampere). Load Ampere continuous: 200Ampere (to be read on starter Ampere meter during operation). Display panel: The container shall be provided with a display on the top housing 2 no voltmeter (0-500V) digital type for incoming & outgoing feeder & 3 no phase indication lamps (RYB) of neon type. Cooling medium: The container shall be filled with relevant grade T-oil up to the required level. Connection Box: The stabilizer shall be provided with complete input/output connection box to ensure proper input/output power supply of voltage stabilizer. The equipment has to be provided/ installed at site and successfully tested commissioned on full load.
Supply, installation, testing and commissioning of 3 phase, 300 Ampere, 4 pole, 415V Bus bar. Make: Havells/Asco/standard reputed make
P/F, installation & testing of flood light luminaries with cast Al. housing and toughened glass cover (metal halide lamp/filament of 400 watt). The lighting should comprise of all accessories such as lamps chokes, condensers and other fittings with its inner wiring in FRLS copper wire. Every flood light Shall be mounted outside the pump house wall & wiring in 4mm2 FRLS PVC INSULATED copper conductor in exposed flexible conduit including p/f of 16 amp D.P switch of Anchor/ssk make. The fittings shall be of doller/havels make.
SITC of 3 phase, 200 Ampere LT Switch Disconnector fuse, 4 pole, 415V . Make: Havells/Asco/standard reputed make
a. P/F/I/T and commissioning of lighting points in the pump house/panel room. the job includes p/f of wall mounted angled holder of ssk/anchor make wiring in 1.5 mm2 FRL PVC copper conductor in exposed pvc conduit includes p/f of 6amp switch of ssk/anchor with suitable box .the job includes/f of 50 watt energy saver of havells/Anchor make. (4 No.) b. P/F installation & testing of 3 pin socket of ssk/Anchor make fitted in the suitable box wiring in 1.5 mm2 FRLS Pvc copper conductor in exposed pvc conduit in the panel room as mobile charger etc (4 No.) c. P/F installation & testing of 16 Amp ss combine of ssk/Anchor make in suitable box wiring in 4 mm2 copper conductor /7/18 pvc copper conductor in exposed pvc conduit for heating point. (2 No.)
M/S NEW BUHROO ELECTRICAL AND MECH ENGG WORKS
M/s INFO ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .