Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC 1853 2ND FLOOR SURYA BAZAAR BHAGIRATH PLACE DELHI 06 | NORTH | DELHI | 110006 | L1 | Accepted-AOC Selected | |
| 2 | L2₹9.8 L+₹91,415 (10.3%)Rejected-AOC 2628 KUCHA CHALAN DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | L2 | Rejected-AOC Selected | |
| 3 | L3₹10.2 L+₹1.3 L (14.3%)Rejected-AOC | L3 | Rejected-AOC Selected | |
| 4 | L4₹10.6 L+₹1.7 L (19.2%)Rejected-AOC | L4 | Rejected-AOC Selected | |
| 5 | L5₹10.6 L+₹1.7 L (19.3%)Rejected-AOC GROUND FLOOR G 1154 A MANSAROVAR PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | L5 | Rejected-AOC Selected |
Tender Value
₹12.0 L
EMD Value
₹23,918
Closing Date
5 Dec 2018, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Providing Electrical Installation at DC-I , DC-II office and Branches at 5 Sham Nath Marg, Delhi.
2018_PWD_162429_1
177 /EE (E)/PWD DHC and ND/Central /2018-19
Open Tender
Electrical Works
Works
60 days
Delhi
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹23,918
29 Sept 2020
24 Nov 2018
5 Dec 2018
24 Nov 2018
5 Dec 2018
24 Nov 2018
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. ( a ) Group C
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 25mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class steel conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
c) 2 X4 sq. mm + 1 X 4 sq. mm earth wire
d) 4 X4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 6 pin 5/6 & 15/16 ampers modular socket outlet and 15/16 ampers modular switch, connection etc. as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 25 ampers modular socket outlet and 25 ampers modular MCB, connection etc. as required.
Supplying & fixing of call bell / buzzer suitable for D.C. / A.C. single phase, 230 volts complete etc as required.
Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a) 1 or 2 Module
b) 12 Module
Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 15/16 ampers switch.
b) 6 pin 15/16 ampers socket outlet
c) Stepped type electronic fan regulator (2 module)
d) Telephone socket outlet
e) Input/output RJ-45
Supplying and fixing of following way, horizontal type TPN / SPN, sheet steel, MCB distribution board, 415 / 230 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way (4 + 24), Double door
b) 12 way, Double door, SPN
c) 8 way, Double door, SPN
Supplying & fixing of following accessories in the existing TPDB / M.S. box including connections testing, commissioning etc. as required. a ) 5 to 32 ampers SP MCB
b ) 63 ampers SPN MCB
c ) 63 ampers TPN MCB
Supplying and fixing of Cable End Box (Loose Wire Box) suitable for following TPN/SPN, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. a) For 8 way, Double door SPN MCBDB
b) For 14 way, Double door SPN MCBDB
c) For 8 way, Double door TPN MCBDB
Supplying, laying & fixing of following size XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade on surface etc. complete as required. a) 4 x 25 sq. mm.
b) 3 x 10 sq. mm.
Providing and fixing of 6 SWG diameter G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 4 x 25 sq. mm.
b)3 x 10 sq. mm
Supplying, installation, testing & commissioning of energy efficient 1400 mm sweep size ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing of phenolic laminated sheet cover on fan box etc as required.
Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Supplying & fixing of energy efficient 15 watts LED down lighter luminaries in the surface including connection, testing etc. as required The Total minimum system efficacy of luminaries should be minimum 80 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Supplying & Fixing of energy efficient 15 liters Capacity storage type water gysers/heater alongwith water connections etc. including dismantling & credit for worn out geyser under buy back arrangement etc. as required.
Supplying & replacement of 380/400 mm sweep size 230 Volts, single phase, 50 Hz wall fan with suitable mounting arrangement including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying, installation, testing & commissioning of 20W to 22W, 6000K (1200 mm) energy efficient LED wall mounted light luminaries, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work on 230 volts, AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required at site including dismantling & credit for old luminaries under buy back arrangement. The luminaries shall be submitted with LM-80 report with a life of 50000 hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram
Supplying, Installation, testing and commissioning of 250 mm sweep size Fresh air fan with louver shutter 230 Volts, single phase, 50 Hz including making the suitable hole and repairing the damages and making good the same including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and drawing of 4 pairs 0.5 mm diameter FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit etc as required.
Supplying and drawing of UTP 4 pairs CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit etc as required. a) 1 run of cable
Supplying, installation, testing & commissioning of energy efficient following capacity Split type Air Conditioner unit suitable for operation on 230 Volts, 50Hz, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection with upto 4 meters length refrigerant copper pipe heavy gauge 2"/8" / 3"/8" & 5/8" covered with minimum 10mm thickness insulation including 3 x 2.5 sq.mm flexible copper conductor wire wrapped in flexible pipe and also providing 25mm diameter PVC drain connection including accessories, fixing on surface with clamp to the nearest drain connection pipe complete with repairing of wall with minor civil work at site etc as required. a) 1.5 TR Capacity
b) 2.0 TR Capacity
Providing & Laying of refrigerant copper piping of size 5/8” & 1/4” diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of cotton thread ribbed PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc as required. (Measurement to be done for quantity after 4 meters, which is included in item no -24a & b)
M/S COOL RAYS
M/s JAI SHREE BALAJI ELECTRICAL
Rishika Associates
Krishna Electreical Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .