Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Lowest reasonable tender | |
| 2 | L2₹10.2 L+₹9,200 (0.91%)Rejected-Finance 1597 1ST FLOOR SECTOR 45 BURAIL CHANDIGARH CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | 160047 | L2 | Rejected-Finance Not Lowest Tenderer | |
| 3 | L3₹10.4 L+₹28,320 (2.81%)Rejected-Finance 22 1755A KANNANKATTU TEMPLE ROAD EDAKOCHI KOCHI 682010 ERNAKULAM KERALA 682010 | ERNAKULAM | KERALA | 682010 | L3 | Rejected-Finance Not Lowest Tenderer | |
| 4 | L4₹11.5 L+₹1.4 L (13.6%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Tenderer | |
| 5 | L5₹12.9 L+₹2.8 L (27.6%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Tenderer |
Tender Value
Refer Docs
EMD Value
₹29,060
Closing Date
5 Apr 2021, 6:00 pmClosed
GE Ranikhet
GE Ranikhet
PROVN OF OXYGEN GAS PIPE LINE FOR ICU AT MH RANIKHET UNDER GE RANIKHET
2021_MES_426093_1
GE/RKT/66 OF 2020-2021
Open Tender
Industrial/Medical GAS
Item Rate
180 days
GE Ranikhet
Class E cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Ranikhet
₹29,060
Yes
22 Apr 2021
26 Feb 2021
7 Apr 2021
26 Feb 2021
5 Apr 2021
15 Mar 2021
Amount
BOQ ( Sch A ) Oxygen Gas pipeline works Supply and fixing of point wiring for one 6 pin socket outlet, 16 Amp (independent point), controlled by one, one way switch with 2.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) drawn into and including medium grade PVC casing caping /PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 2.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly complete all as specified and directed. (Note:- wiring shall be in done in colour coding as directed by Engineer in charge )
Supply and fixing of switch piano flush type single pole one-way 15 Amp complete all as specified and directed.
Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amp flush type, complete all as specified and directed.
Supply,fixing,testing and commissioning the outlets shall be surface mounted, non interchangeable and self sealing type. The outlets shall consist of a roughing in assembly and a finishing assembly. A non removable positive pin keying arrangement for each specific gas service. Design of outlet shall be such as the feature to accept only one type of probe and push button mechanism for quick release of adaptor and a plastic cap inserted at the end of the inlet tube. Rotation of the inlettube should allow gas connection from the top or bottom. The finishing assembly should consist of a plastic cover plate , a machined brass/ SS housing for the primary check valve, and a positive pin keying device to prevent accidental installation into a roughing in assembly of a dismal gas.The outlet shall have control mechanism so that absolutely no gas flow takes place until the keying devices are engaged. Adapter for Oxygen and with all applicable HTM2022 standards. Each adapter shall have suitable barb or threads so that it should be connected to tube or flow meter /suction regulator complete all as specified. Make:-Oasis Medical Systems or Amico or Cagdas,Medical Gases System, Krishna Surgical, MN life care, MR Engineeering / JK Enginerring
Supply,fixing,testing and commissioning the pipes shall be of copper Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased conforming to BS-6017/ 1981, Table 2 (Cu-DHP) and manufactured as per EN-13348. Fittings shall be made of copper conforming to BS 864 and suitable for a steam of working pressure of 35 bar and especially made for brazed socket type connections. Installation of pipes shall be carried out as per international standards with utmost cleanliness. Only pipes, fittings and valves which have been degreased as per International standards shall be used. Pipe fixing clamps for upto 28mm diameter should be non ferrous suitable for the diameter of the pipe. For the pipes of the size above 28mm rigid metallic hanging or cemented supports shall be used. All pipe joints shall be made using inert gas flux less brazing method. All joints should be of copper to copper and will be brazed by silver brazing filler material without flux. While being brazed joints will be continuously purged with oil free dry nitrogen to prevent the formation of copper oxide on the inside surface of the joint. All pipes shall be installed without springing or forcing. All pipes shall be protected against mechanical injury.The pipes shall be painted with two coats of Synthetic enamel paint and color codification as per international standards. All concealed pipes shall have gas identification bands/labels at appropriate distance. Similarly all pipes which need embedding in the wall should be tested/painted/labeled and properly insulated. complete all as specified and directed. The rate quoted for pipes shall be inclusive of painting as specified. The color coding shall be as given below:White = Oxygen Make Metal Alloys , Max Flow
Supply,fixing,testing and commissioning Isolation Valve 15mm Isolation valves of reputed makes, non lubricated, 90 degree turn lever, stainless steel half valves with PTEF seat ,suitable for the size of copper pipe dia with screw threaded ends and brass. The valve shall be pneumatically tested for twice the working pressure and degreased for medical gas service before supply. Valves should be equipped with components for shutting off and pervising individual /parts of central systems in hospital, laboratories and the like. They shall facilitate the ward staff to allow isolating of the areas for maintenance and repair work complete all as specified and directed. Make:- Oasis Medical Systems or Amico or Cagdas, ZOLOTO, RN , JSI
Supply,fixing,testing and commissioning Isolation Valve upto 22mm Isolation valves of reputed makes, non lubricated, 90 degree turn lever, stainless steel half valves with PTEF seat ,suitable for the size of copper pipe dia with screw threaded ends and brass. The valve shall be pneumatically tested for twice the working pressure and degreased for medical gas service before supply. Valves should be equipped with components for shutting off and pervising individual /parts of central systems in hospital, laboratories and the like. They shall facilitate the ward staff to allow isolating of the areas for maintenance and repair work complete all as specified and directed. Make: ZOLOTO, RN , JSI
Supply,fixing,testing and commissioning the Oxygen Manual Manifold 4x4 Complete with Fitting without Cylinders; The oxygen manifold of size 4+4 bulk cylinders shall be provided . Manifold should be suitable to withstand a pressure of 140 Kg/Sqcm, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. The top frame shall comprise of high pressure copper pipes of size ½ inches inner dia and pipe wall sheet thickness of 15 swg with high pressure brass fittings made of high tensile brass and connections through non-return valves, high pressure copper tail pipes, made of high pressure copper pipes of size ¼ inches inner dia and pipe wall sheet thickness of 15 swg . The middle and bottom frame shall be provided to fit both round and flat bottom cylinders safely. The manifold shall be tested hydraulically at 3500 PSI complete all as specified and directed. Make:Oasis Medical Systems or Amico or Cagdas, Merdical Gases System, Air case Engineering/ MR Engineering
Supply,fixing,testing and commissioning the Oxygen Manual Manifold 1x1 Complete with Fitting without Cylinders; The oxygen manifold of size 1+1 bulk cylinders shall be provided . Manifold should be suitable to withstand a pressure of 140 Kg/Sqcm, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. The top frame shall comprise of high pressure copper pipes of size ½ inches inner dia and pipe wall sheet thickness of 15 swg with high pressure brass fittings made of high tensile brass and connections through non-return valves, high pressure copper tail pipes, made of high pressure copper pipes of size ¼ inches inner dia and pipe wall sheet thickness of 15 swg . The middle and bottom frame shall be provided to fit both round and flat bottom cylinders safely. The manifold shall be tested hydraulically at 3500 PSI complete all as specified and directed. Make:Oasis Medical Systems or Amico or Cagdas, Merdical Gases System
Supply and installation testing commissioning of fully automatic control panel with cover made of M.S duty powder coated, compact fully automatic manifold cylinder pressure control system for oxygen service. Easy to maintain and use designed with both safety and continuity of flow supply at a constant pressure via two bank of bottled gas cylinder with following status monitoring A – Bank in use (green indication) B – Bank ruddy to use (yellow indication ) C- Empty bank (Red indication ). Control panel has built in LED display to indicate. Normal high & low line pressure it has facility to test all above indicators working perfectly. The control panel include pressure gauge to indicate the gas pressure of each header and pipe line distribution pressure. Capable to proved a distribution flow in excess of 1500 lmp complete all as specified and directed. MAKE:- Oasis Medical Systems or Amico or Cagdas, Medical Gases System, Krishna Surgical, MN life care
Supply,fixing,testing and commissioning area Alarms shall be designed to include all necessary digital displays, factory wiring and transformers etc. The circuitry requiring shall only be 115 volt or 230 V AC primary powers. Internal voltage should be stepped down to 5 V DC and 15 V DC for control circuit Power. Voltage to external pressure or vacuum transducers will be 15 V DC. Each gas monitored shall have a light Emitting Diode (LED) display to continuously indicate actual line pressure. A vertical series of LED’s should further indicate relative line pressure. The control module shall be inclusive of a mute button and a Test button. These buttons should be used to silence the audible alarm, set up the alarm panel and to test the alarm panel. The test button should be tested for all modules one at a time. An LED on the control module should be illuminated green to indicate Power on. The LED shall be shown Normal pressure at 50 PSI. Apart from Normal it shall also show low risk of 40 PSI as low pressure and 60 PSI as high. High risk of 30 PSI as low pressure and 70 PSI as High pressure. The power supply shall be installed in the back box. Power supply shall include an on / off rocker switch and a fuse holder.The audible signal shall be cancelled only by the alarm silence button or fault correction. The display should remain illuminated to indicate the presence of the alarm condition. The alarm shall be automatically reset with the correction of the fault condition. In case a new alarm occurs while the panel is silenced, the audible alarm will reactivate. The area alarm shall store the last four alarm conditions in memory at the alarm panel. These conditions shall be accessible by using the buttons on the alarm panel control module complete all as specified and directed. Make:Oasis Medical Systems or Amico or Cagdas, Medical Gases System, Krishna Surgical
Supply and installation testing commissioning of back pressure compensated ( BPC ) oxygen flow meter body should be made brass material dully chrome plated and graduated from 0-15 lmp on an expended lower scale for precision setting at low flow and 5- 15 lmp for general use. The humidifier bottle should be made to un breakable polycarbonate/polysulphone material and autoclavable at 1.2.1 degree centigrade temperature. it should be CE and ISO certificated complete all as specified and directed. MAKE - MN LIFE CARE PRODUCT KOLKATA
Supply and installation of Rubastrank bed head panel size 1600 x 300 mm the bed head panel made by 2 mm aluminum peer casting suction with powder coated the powder coated color as per customer choice The panel as provision 2 nos medical gas outlet point and electrical system complete all as specified and directed. MAKE .MR ENGINEERING / JK ENGINEERING, Oasis Medical Systems, Medical geses system and balaji
ADP Engineering
Sanjay Traders
Medical Gases System
singh traders
KPELECTRICAL AND AUTOMATION
M/S NAYAL ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .