Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | NTR | ANDHRA PRADESH | 520001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.1 L+₹2.7 L (9.13%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹33.1 L+₹3.6 L (12.3%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹33.5 L+₹4.1 L (13.9%)Rejected-Finance NEAR KONAM GUEST HOUSE CO OPERATIVE COLONY CHODAVARAM VISAKHAPATNAM 531036 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 531036 | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹37.0 L+₹7.6 L (25.7%)Rejected-Finance | L5 | Rejected-Finance Being Not L1 |
Tender Value
₹39.8 L
EMD Value
₹79,600
Closing Date
3 Jul 2023, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
PROVISION OF POL STORE, SPARE GEAR STORE AND ADJOINING PARKING SHED (JETTY SIDE OF BLDG NO.17, C.NO.97) AT NAVAL DOCKYARD VISAKHAPATNAM UDER GE (I) DM VISAKHAPATNAM
2023_MES_597469_1
8862/E8
Open Tender
Civil Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) DM Visakhapatnam
₹79,600
Yes
29 Jul 2023
22 May 2023
10 Jul 2023
22 May 2023
3 Jul 2023
19 Jun 2023
Amount
[SCHEDULE 'A' PART-I [B/R WORKS]
Excavating in post holes (or similar holes) each n. exc. 0.5 cum, getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm watering and removing surplus soil to distance n. exc 50 m and making good surface complete all as specified and directed in hard /dense soil .
Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil all as specified and directed.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
M&L for sand filling under floor including watering and consolidation complete all as specified and directed.
M&L hard core of broken stone of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L for Moorum filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering and consolidation complete all as specified and directed.
M&L PCC 1:4:8 type D2 type (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L 100 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) in sub base of floors finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L 100 mm thick cement concrete 1:2:4 type B2 using 40 mm graded stone aggregate) as in floor and finishing the surfaces even and smooth with using extra cement complete all as specified and directed.
M&L 75 mm thick cement concrete 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) in floors (plinth protection) finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Material & Labour for coloured glazed ceramic tiles (300 x 450) x 7-8 mm thick in dado set and jointed in neat cement slurry and pointed in coloured cement to match fixed over & including rendering in CM 1:3, 10 mm thick complete all as specified and as directed.
M&L chequered cement concrete tiles with grey cement and any pigments of size30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments over 15 mm thick 1:6 cement morter screed bed as in floor complete all as specified and directed.
M&L RCC (design mix) M-30 (using 20 mm graded crushed stone aggregate) as in foundation, plinth beams, base of column, footing and mass concrete etc. complete all as specified and directed.
M&L RCC (design mix) M-30 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers posts and struts etc. complete all as specified and directed.
M&L RCC (design mix) M–30 (using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.5 m span complete all as specified and directed.
M&L RCC (design mix) M-25 (using 20 mm graded crushed stone aggregate) as in slab, supported on walls, beams, columns in floors, roofs, landing, shelves etc. complete all as specified and directed.
Use and waste form work to side of concrete foundation, footings, bases of columns, raft and beams and similar work, vertical or to batter as in rough finished surfaces of concrete all as specified and directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns etc. square, rectangular or polygonal section as in fair finished surfaces complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing or similar work not. exc. 200 mm thick horizontal or sloping complete all as specified and directed as in fair finished surfaces.
Use and waste of form work to sides and soffits of floor or roof beams, lintels, over 1.5 m span, cantilevers, shelves including supports, overhangs etc. complete all as specified and directed as in flat and fair finished surfaces complete all as specified and directed.
M&L MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed.
M&L M.S. TMT bars 5 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as in stirrups spaces, binders and nibs etc. complete all as specified and directed.
M&L for Pre cast cement concrete type 1:3:6 type C-2 (20mm graded stone aggregate) block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and as directed.
M&L rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement.
M&L rendering 10 mm thick in CM 1:6 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement.
M & L preparation of newly plastered surfaces of walls and applying two coats of exterior emulsion paint (weather coat) over a coat of alkali resistance primer complete all as specified and directed.
M&L preparing new surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer over a coat of wall putty minimun thickness 1.5mm and cutting to smooth surfaces by sand paper complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying two coats of white washing complete all as specified and directed.
M&L water proofing treatment on cleaned RCC roof comprises with the following operation as specified here-in-below :- (a) 20 mm thick (av. mimimum thickness) plastering in cement mortar 1:3 mixed with liquid water proofing compound @ 3% by weight of cement & finishing the plastered surfaces even and smooth over cleaned RCC roof. The plastered surface shall be cured properly for ten days by ponding of water over roof. (b) After drying the surface, apply bitumen primer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps over the plastered surface @ 0.40 Ltr / Sqm. The manufacturer of primer shall be the same membrane manufacturer (c) Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt make as approved over the primer coat. Membrane shall be laid using butane torch and sealing all joints etc all as per Para 11.44.5 of SSR Part I. (d) Applying one coat of Aluminium paint @ 0.1 ltr per Sqm over APP based polymetric membrane complete all as per manufacturer's instruction.
S&F aluminium door shutter with chowkats made out of hollow aluminium sections as mentioned below, each shutter having 2 Nos ‘D’ type aluminium handles of 200mm long 2 Nos aluminium tower bolts of 150 mm long and 1 No brass mortice lock of 6 lever with key in duplicate. Shutter shall be partly glazed with 5 mm thick sheet glass ordianry quality and partly panelled with 12mm thick particle board, pre-laminated interior grade, prelaminated one side with decorative choice lamination, on other side balancing light grey lamination fixed with glazing clips, rubber beadings and aluminium beadings complete all as specified and directed. Chowkat size : 101.60 x 44.45 x 2.40 mm (1.608 Kg/RM appx) Shutter Top rail : 114.30 x 2.15 mm thick (1.836 Kg/RM appx) Bottom rail: 150.00 x 2.20mm thick (2.376 Kg/RM appx) Middle rail : 83.50 x 1.70 mm thick (1.243 Kg/RM appx) Vertical rail : 85.00 x 1.80 mm thick (1.302 Kg/RM appx)
M&L for Pre-painted Galvalume aluminium zink coating GI based corrugated / semi corrugated or trapizoidal section steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof coverings/clading to wall, fixed with self taping screws complete all as specified and directed.
M&L for Pre-painted Galvalume aluminium zink coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof coverings/clading to wall, fixed with self taping screws complete all as specified and directed.
M&L MS in tubular trusses (framed), trussed, purlins including special shaped washer etc. complete using ERW or induction butt welded tube conforming to IS 1161 -1979 grade St -240 complete all as specified and directed.
M&L MS in tubular section as in pole including special shaped washer etc. complete using ERW or induction butt welded tube conforming to IS 1161 -1979 grade St -240 complete all as specified and directed.
M&L mild steel plates plain channels, square cut or notched forming holes , bolted or welded attachement, confirming to Fe- 290 Gde E-165 complete all as specified and directed.
M&L Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 15cm but not. Exc.30 cm long long complete all as specified and directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
S&F for 1.25mm thick steel rolling shutters, with out ball baring, as specified including top cover, anchoring rod, hasp and staple, shaft, pipe, brackets, gear operated type with bevel gear box and crank handle and one shop coat of primer, erected in position as indicated complete with bevel gear box and crank handle as specifiedd and and directed.
S&F safety lever locks mild steel with 4 levers for rolling shutter, complete all as specified and directed.
S&F ball bearing for rolling shutter, complete all as specified and directed.
[SCHEDULE 'A' PART-II [E/M WORKS]
M&L surface type point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including MS stove enamelled conduit medium grade with all fittings and accessories of steel conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 1.5 Sqmm (nominal area) PVC insulated, FRLS unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point supply & fixing of 1.6 mm thick galvanised pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for one light / Fan /bazzer point controlled by one one way switches complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed..
M&L surface type point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including MS stove enamelled conduit medium grade with all fittings and accessories of steel conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 1.5 Sqmm (nominal area) PVC insulated, FRLS unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick galvanised pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for one 3 pin 5/6 Amp socket outlet on independent board complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed..
M&L surface type point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including MS stove enamelled conduit medium grade with all fittings and accessories of steel conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 1.5 Sqmm (nominal area) PVC insulated, FRLS unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick galvanised pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for one light / Fan /bazzer point controlled by one one way switches complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed..
M&L wiring concealed type with two runs of 2.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through MS stove enamelled conduit medium grade with all fittings and accessories of steel conduit (like Tee, bend etc.)complete fixed to wall / ceiling etc incl one run of 2.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. . (Note :-(i) MS stove enamelled conduit with all fittings/accessories shall be measured and paid separately. (ii) Two runs of 2.5 sqmm single core cable, one run of 2.5 sqmm earth continuity wire to be measured as one length
M&L wiring concealed type with two runs of 4.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through MS stove enamelled conduit medium grade with all fittings and accessories of steel conduit (like Tee, bend etc.)complete fixed to wall / ceiling etc incl one run of 4.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. . (Note :-(i) MS stove enamelled conduit with all fittings/accessories shall be measured and paid separately. (ii) Two runs of 4.0sqmm single core cable, one run of 4.0 sqmm earth continuity wire to be measured as one length
Supply & fixing 20 mm dia MS stove enamelled medium grade PVC rigid conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) including complete all as specified and directed.
S&F LED flame proof fitting for twin a T8 tube of 16W each with retro LED tube including connection with suitable 3 core wire from ceiling rose to fitting terminal with necessary fixing arrangement complete all as specified and directed.
S&F MCB SP 6 to 32 Amps C Curve complete all as specified and directed.
S&F MCB SPN 6 to 32 Amps C Curve complete all as specified and directed.
S&F concealled TPN DB 4 way, double door, with 200 amp rated bus bar complete all as specified and as directed Note:Cutting chases for DB &making good is be included in the quoted rate
S&F flame proof exhaust fan of size 457 mm AC single phase 230/240V sweep with louver complete including connection with suitable 3 core wire from ceiling rose to fitting terminal with necessary fixing arrangement complete all as specified and directed, Note: Cutting hole and making good the disturbed surface is e included in the quoted rateall as specified and directed.
S&F Flame Proof weather proof rotary switch 16A,2pole with separate cable termination box complete all specified and directed. Make :- Cat PartNo.SSPL/RI/1010 Shyaam or equivalent in Sudheer
M & L earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected with 4mm dia GI wire by means of bolts washers and protected by 15mm bore, medium grade GI pipe, funnel with 20mm bore GI medium grade watering pipe, wire mesh, copper lugs including concrete pit in PCC 1:3:6 type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350X350X50 mm, reinforced with 8mm dia deformed bars @15 cm C/C both direction and 10mm MS handle of suitable size, charcoal or coke and salt in alternate layers, necessary earth work in soft/loose soil, all as shown in Electrical Plate No 3 of MES Schedule Part-I and testing, complete all as specified and as directed.
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed.
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed.
S & F socket outlet 5 Pin, 5/6 Amps, flush type, multipurpose, conforming to IS all as specified and as directed.
Supply & fix LED batten with CRCA body,pre coated with white and prewired suitable for LED tube1x18/20 watt 4'long alongwith 1 number of tube including connection with suitable 3 core wire from ceiling rose to fitting terminal with necessary fixing arrangemen Make :-Cat Part No BCLSB 18 NW LED of Bajaj or equivalent in CG/Philips/wipro.
M&L for energy efficient 90 W LED street / bldg. security light luminaire for road lighting with pressure die-cast aluminium IP66 protection and high power LED as light source with acrylic cover including supply & fixing with 40 mm dia medium grade GI pipe bracket 1.5 mtr long bent to shape, mounted on wall / pole with suitable clamps, bolts, nuts and all accessories complete including connection with 3 core PVC insulated sheathed flexible cable with muyltistranded copper conductor from celing rose to fitting terminal all as specified and as directed
SATYAMEGHA ENGINEERS
SREE HANUMAN ENTERPRISES
SINGH BUILDERS
CIVILEC ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .