SITC of AC machines at Dooars Kanya Building Room no. 601 and 605 in the District of Alipurduar.
2026_NBDD_1038300_7
NBDD/BS/EE /NIQ-15- (EL) of 2026-2027 (SL No. 13 to 20)
Open Tender
Electrical Work/ Equipment
Item Rate
Alipurduar
Please refer Tender documents.
6 documents required · 6 mandatory
₹7,500
Yes
14 Aug 2026
14 Aug 2026
3 Sept 2026
14 Aug 2026
31 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year OriginalEquipment Manufacturer (OEM) warranty both compressor
and Printed Circuit Board (PCB). Must comply : Electrical
cable IS 694 or IS 9968 temperature sensing control IS
/International Electrotechnical Commission (IEC) 60730,
hermetic compressor IS 10617, heat exchanger IS 11329,
capacitor IS 2993 and motor IS 12615. Complete as per
CPWD specification and IS : 1391 Part II 2023. The system
shall be able to operate up to 50 0C (out door ambient
temperature). 2.0 TR with 5 Star BEE Rating | - | Nos | - | - |
| 2 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required. 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2
mm | - | Mtr | - | - |
| 3 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | - | Mtr | - | - |
| 4 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | - | Mtr | - | - |
| 5 | Supplying and delivery of following size Un-Armoured cables XLPE insulated are designed for 1.1 kV Stranded copper conductor and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) 3 core 2.5 sqmm (Make-Polycab/Finolex/RR Kable) | - | Mtr | - | - |
| 6 | 4 core 1.5 sqmm (Make-Polycab/Finolex/RR Kable) | - | Mtr | - | - |
| 7 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required | - | point | - | - |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm | - | Mtrs | - | - |
| 9 | LED Batten light (System lumen efficacy ≥120 85%, perating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 urning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .
LM79 & LM80 Test report and all testing required
for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 18-22 Wat | - | Set | - | - |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | - | mtr | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2550656.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].