Chief Engineer, Gujarat Pavitra yatradham vikas Board, Dr.Jivaraj Mehta bhavan, Block- 2,1st floor, Old Sachivalay, Gandhinagar
Providing & Fixing Fire Fighting System and Other Miscellaneous Work at Exhibition and Museum Building at Kanthalpur, Ta. Dahegam, Dist. Gandhinagar
280030
36/2025-26
Open
Civil - All
Works
Gandhinagar
3 documents required · 2 mandatory · 1 optional
₹3,600
Secretary, Gujarat Pavitra Yatradham Vikas Board
₹1.2 L
24 Feb 2026
24 Feb 2026
24 Feb 2026
12 Mar 2026
24 Feb 2026
Name of Work: Providing & Fixing Fire Fighting System and Other Miscellaneous Work at Exhibition and Museum Building at Kanthalpur, Ta. Dahegam,
Dist. Gandhinagar
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Dismentaling of sheet roofing including ridges, Hips,
Valleys, Gutters etc. stacking of serviceable materilas and Rupees Fifty And Paise
disposal of unserviceable materials with all lead and lift. Eleven Only
(i) G.I.sheet/Gypsum board roofing.
Clearing and grubbing road land including uprooting rank
vegetation grass bushes, shrubs, sapling and trees girth
Rupees Two And Paise
2 200.00 up to 300 mm removal of stumps of trees cut earlier and Smt 2.84
Eighty Four Only
disposal of unserviceable materials (C) By mechanical
means in area of light jungle
Excavation for foundation upto 1.5 m depth including
Rupees Two Hundred
sorting out and stacking of useful materials and
3 71.22 Cumt. 212.52 Twelve And Paise Fifty Two
disposing off the excavated stuff upto 50 Meter lead. (B)
Dense or Hard soil
Excavation for foundation for depth from 1.5 m to
Rupees Two Hundred
m including sorting out and stacking of useful materials
4 52.00 Cumt. 295.10 Ninety Five And Paise Ten
and disposing off the excavated stuff upto
Meter lead. (B) Dense or Hard soil
Excavation for foundation for depth from 3.0 m to
Rupees Three Hundred
m including sorting out and stacking of useful materials
5 21.00 Cumt. 317.62 Seventeen And Paise Sixty
and disposing off the excavated stuff upto
Meter lead.(B) Dense and Hard soil
Filling available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not Rupees One Hundred Thirty
6 132.22 exceeding 20 cm. in depth consolidating each deposited Cumt. 136.92 Six And Paise Ninety Two
layer by ramming and watering upto optimum moisture Only
Filling in plinth with murrum or selected soil in layers of Rupees Two Hundred
7 24.00 20 cm. thickness including watering, ramming and Cumt. 277.14 Seventy Seven And Paise
consolidating etc. Complete. Fourteen Only
Providing and laying cement concrete work 1:2:4 (1-
Rupees Three Thousand
Cement : 2- Coarse sand : 4- graded stone aggregates
8 14.57 Cumt. 3,758.19 Seven Hundred Fifty Eight
mm nominal size) and curing complete including cost of
And Paise Nineteen Only
formwork in (A) Foundations and plinth
Providing, laying controlled cement concrete M 250 and
curing complete including the cost of form work (rates Rupees Four Thousand
9 17.32 for centering, shuttering, formwork staging scaffolding for Cumt. 4,752.05 Seven Hundred Fifty Two
considering up to 4.50 m height) but excluding And Paise Five Only
reinforcement for reinforced concrete work in (A) Footing
Providing, laying controlled cement concrete M 250 and
Rupees Seven Thousand
curing complete including the cost of form work (rates
Eight Hundred Ninety
10 3.56 for centering, shuttering, formwork staging scaffolding for Cumt. 7,893.15
Three And Paise Fifteen
considering up to 4.50 m height) but excluding
reinforcement for reinforced concrete work in (A) Column
Providing, laying controlled cement concrete M 250 and
curing complete including the cost of form work (rates
Rupees Seven Thousand
for centering, shuttering, formwork staging scaffolding for
11 13.00 Cumt. 7,909.31 Nine Hundred Nine And
considering up to 4.50 m height) but excluding
Paise Thirty One Only
reinforcement for reinforced concrete work in (C) RCC
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Providing, laying controlled cement concrete M 250 and
curing complete including the cost of form work (rates
Rupees Six Thousand Four
for centering, shuttering, formwork staging scaffolding for
12 5.89 Cumt. 6,416.53 Hundred Sixteen And Paise
considering up to 4.50 m height) but excluding
Fifty Three Only
reinforcement for reinforced concrete work in (C) RCC
floor beam i) Ground Floor slab level
Providing, laying controlled cement concrete M 250 and
curing complete including the cost of form work (rates
Rupees Six Thousand Six
for centering, shuttering, formwork staging scaffolding for
13 11.09 Cumt. 6,679.13 Hundred Seventy Nine And
considering up to 4.50 m height) but excluding
Paise Thirteen Only
reinforcement for reinforced concrete work in (C) RCC
Slab i) Ground Floor slab level
Providing TMT Bar FE 500D reinforcement for R.C.C. work
Rupees Seventy Seven And
14 7,237.00 including bending, binding and placing in position KG 77.29
Paise Twenty Nine Only
complete upto floor two level
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg/Sq. Cm. in Rupees Four Thousand Two
15 16.38 foundation and plinth in cement mortar 1:6 (1 cement : 6 Cumt. 4,214.09 Hundred Fourteen And
fine sand) Up to Plinth level. (B) Conventional (more than Paise Nine Only
10 ton) up to plinth
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg/Sq. Cm. in Rupees Four Thousand Two
16 20.35 foundation and plinth in cement mortar 1:6 (1 cement : 6 Cumt. 4,214.09 Hundred Fourteen And
fine sand) (B) Conventional (more than 10 ton) (A) Paise Nine Only
Providing & fixing 15 mm cement plaster in single coat on
brick/concrete wall for interior plastering finished even Rupees One Hundred
17 88.48 and smooth in cement mortor 1:4 (1 cement : 4 coarse Smt 185.41 Eighty Five And Paise Forty
sand) including floating coat of neat cement including One Only
finishing etc complete. (a) Ground Floor
10mm th cement plaster in single coat on fair Side of
brick/ concrete wall for interior plastering upto floor two Rupees Two Hundred Nine
18 89.88 level finished even and smooth in C M 1:4 (1 cement 4 Smt 209.97 And Paise Ninety Seven
coarse sand) including floating coat of neat cement Only
including finishing etc complete. (a) Ground Floor
Providing 20 mm thick double coat mala cement plaster
on interior brick/ concrete work for plastering comprising
of base coat of 12 mm thick cement plaster in cement Rupees Two Hundred
19 237.22 mortar (1 Cement : 4 coarse sand) in rough finishing and 8 Smt 286.10 Eighty Six And Paise Ten
mm thick top coat of cement mortar 1:2 (1 Cement : 2 Only
Coarse sand) finished with trovel including scaffolding
curing etc. complete.
Providing 20 mm thick water proof cement plaster using
water proofing powder 1Kg/1bag of cement for all floors
on brick/ concrete wall work using water proofing
materials in C M 1: 4 (1 cement 4 coasrse sand) including Rupees Two Hundred
20 106.00 finishing with a flooting coat of neat cement slurry etc Smt 222.20 Twenty Two And Paise
complete for all floor. and shall be guaranteed for Twenty Only
minimum period of 10 years after handing over the
completed building by the main contractor to be finished
Providing and applying two coats of Birla or Asian acrylic
lapy (putty) & two coats of primer of approved brand and
manufacture on new wall surface to give an even shade Rupees Forty And Paise
including thoroughly brushing the surface free from Fifty Nine Only
mortar dropping and other foreign matter and sand
papered smooth.
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Providing and applying Wall painting (three coats) with
plastic emulsion paint of approved brand and
manufacture on under coated wall surface to give and Rupees One Hundred
22 2,236.00 even shade including throughly brushing the surface free Sqmt. 118.59 Eighteen And Paise Fifty
from mortor droppings and other foreign matter and Nine Only
sand paperd smooth on new work to give an even shade
Finishing wall with weather proof low velocity ultima
exterior emulsion paint on wall surface (two coats) to give Rupees One Hundred
23 237.22 an required shape even shade after thoroughly brushing Sqmt. 120.26 Twenty And Paise Twenty
the surface to remove all dirt, and remains of loose Six Only
powdered materials. etc complete for all height
Providing and laying coloured glazed tiles of the size
Rupees One Thousand Five
mm x 450 mm x 8 mm in skirting, risers of steps and dedo
24 84.00 Sqmt. 1,513.28 Hundred Thirteen And
on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse
Paise Twenty Eight Only
sand) & jointed with white cement slurry.
Providing and laying cement concrete flooring 1:2:4 (1-
Rupees Three Hundred
cement : 2-coarse sand : 4-graded stone aggregate 20mm
25 23.00 Sqmt. 369.13 Sixty Nine And Paise
nominal size) laid in one layer and finished with a floating
coat of neat cement. (B) 50mm thick.
Providing cement vata (10 cm x 10 cm size) quartar round
Rupees Twenty Four And
26 20.00 in cement mortar 1:1 including neat cement finishing Rmt. 24.28
Paise Twenty Eight Only
watering etc. complete. For all floor
Rupees Nine Hundred Fifty
Providing and fixing C.I Manhole cover 0.60 mt x
27 1.00 Each 958.17 Eight And Paise Seventeen
mt size having weight not less than 35 Kg
Providing & Fixing iron steps of size 500mm x 150mm x Rupees One Hundred
28 5.00 22.5 mm and painting with two coats of anticorrosive Nos. 172.04 Seventy Two And Paise
paint etc. complete. Four Only
Providing erecting and fixing double coated (3 layer) ISI
Rupees Thirteen And Paise
29 10,000.00 water tankof required capacity each with all necessary LTR 13.13
fittings and connection etc. complete on terrace
Providing and fixing single layer waterproof gypusm
board 12.5 mm thick of the make Newgood Group Co.
Ltd. or equivalent & Newgood Group Co. Ltd. company
sections using waterproof board of size 1220 mm x
mm x 8.0 mm suspended by G.I suapender of size 25 mm
x 3 mm with intermediate channel of size 18 mm x 40 mm
x 0.80 mm at 1220 mm center to center ceiling section of
Rupees Six Hundred Six And
30 2,058.00 size 40 mm x 35 mm x 0.55 mm at 457 mm center to Sqm 606.95
Paise Ninety Five Only
center and perimetre chanel A of size 20 mm x 27 mm x
30 mm x 0.50 mm at edges & drops including paper tap
sand sofit cleat, anchor fastener, scoch bolt connecting
cleat joining compound top coat on ceiling including
making necessary opening for light fitting, diffuser etc.
complete as per detail drawing as directed. The
decorative design will be as per drawing as directed.
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Providing and fixing flush door both sides laminated and
35 mm thick solid core malemine faced three layered pre
laminated flat pressed wood based exterior grade bonded
BWP/BWR synthetic resin having stamped IS 12823 grade
Rupees Three Thousand
I type II including three coats of lacquer polishing to
31 3.00 Smt 3,428.95 Four Hundred Twenty Eight
exposed wooden surfaces and Stainless steel decorative
And Paise Ninety Five Only
type designs fixtures/ fastening etc. including I.T.W.
triangular batten patti of size 30m.m.x30m.m.etc. as per
architectural detailed drawing and as directed by
engineer in charge.
Providing and fixing window having extruded aluminum
Colour anodized section frame main outer size 95mm x
24mm x 1.17mm @ wt.of 0.738 Kg/mt , horizontal Three
track member size 92mm x 31.75mm x 1.30mm,@
Wt.1.07 Kg/mt , vertical member of size 92mm x
31.75mm x 1.50mm @ Wt. 1.06 Kg/mt with sliding Rupees One Thousand Five
32 6.00 shutters of horizontal member size 40 mmx18mm Smt 1,583.95 Hundred Eighty Three And
x1.29mm @ wt.of 0.456 Kg/mt, vertical member of size Paise Ninety Five Only
40mm x 18mm x 1.29 mm @ wt.of 0.456Kg/mt/ with
mm thick transparent bronze colour tinted float glass
with powder coated aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per
Providing and laying 16-18 mm thick polished granite
stone machine cut in single piece (Max. available) in sill
and jambs of door, window, ventilation & lift wall
cladding, staircase flooring landing, risers & treads,
Rupees Three Thousand
skirting laid over 10 mm thick cement mortar 1:3 (1
Three Hundred Twenty
33 7.00 cement : 3 coarse sand) and jointed with grey cement Smt 3,324.92
Four And Paise Ninety Two
slurry with matching pigment incl. rubbing and
polishing,half rounding edge and incl. fixing of hilty
fastener at every 1/3 span of sill as required size etc.
complete colour and shed as approved by architect
engineer in charge.
Provding and fixing M.S. plain grills of required pattern
with M.S. flats at required spacings & frame around, Rupees One Hundred
34 108.00 sequare or round bars with round headed bolts and nuts Kg. 113.12 Thirteen And Paise Twelve
or by screws including applying a priming coat of red lead Only
paint two coat of Oil paint.
Providing laying and jointing in true line and level 40 mm
dia. U.P.V.C. Pipe (SCH -40) line including fittings of
standard make as apprroved by Engineer In charge. Pipe
Rupees One Hundred Forty
shall be fixed on the wall with the help of clamp at every
35 125.00 Rmt. 148.12 Eight And Paise Twelve
two meter C/C or shall be concealed as directed including
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
Providing laying and jointing in true line and level 50 mm
dia. U.P.V.C. Pipe (SCH -40) line including fittings of
standard make as apprroved by Engineer In charge. Pipe
Rupees One Hundred
shall be fixed on the wall with the help of clamp at every
36 100.00 Rmt. 195.67 Ninety Five And Paise Sixty
two meter C/C or shall be concealed as directed including
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Providing and laying 3 to 5 mm thick (250 GSM)
polypropylene tile protection bubble sheet to protect the
floor against services, painting, false ceiling work, piping
work. Sheet should be laid property and; Bok) with
abrotap. After finishing all the work, sheet should be
Rupees One Hundred
removed and clean the surface etc. complete as directed
37 1,994.00 smt 112.11 Twelve And Paise Eleven
by engineer incharge in case bubble sheet will be remove
working time at that time protection bubble sheet change
until the work not complete . Till the false ceiling work is
completed, if the floor sheet gets torn during the work, it
has to be changed immediately. payment has to be
claimed only one time.
Making holes upto 200mm dia. in any RCC members by
diamond Core Cutting machine including disposing the
debries. Upto 750. Depthand Including EPOXY based Rupees One Thousand One
38 20.00 water proofing compound for sealing the joints around nos 1,119.08 Hundred Nineteen And
the pipes, nominal reinforcement wherever required, Paise Eight Only
scaffolding and labour charges for working at all
levels,leads and heights
Making holes upto 152 mm dia. in any RCC members by
diamond Core Cutting machine including disposing the
debries. Upto 750. Depthand Including EPOXY based Rupees Seven Hundred
39 20.00 water proofing compound for sealing the joints around nos 747.40 Forty Seven And Paise Forty
the pipes, nominal reinforcement wherever required, Only
scaffolding and labour charges for working at all levels,
leads and heights
Making holes upto 102 mm dia. in any RCC members by
diamond Core Cutting machine including disposing the
debries. Upto 750. Depthand Including EPOXY based
Rupees Five Hundred Sixty
40 20.00 water proofing compound for sealing the joints around nos 560.55
And Paise Fifty Five Only
the pipes, nominal reinforcement wherever required,
scaffolding and labour charges for working at all levels,
leads and heights
Making holes upto 80 mm dia. in any RCC members by
diamond Core Cutting machine including disposing the
debries. Upto 750. Depthand Including EPOXY based Rupees Four Hundred Sixty
41 10.00 water proofing compound for sealing the joints around nos 469.65 Nine And Paise Sixty Five
the pipes, nominal reinforcement wherever required, Only
scaffolding and labour charges for working at all levels,
leads and heights
Making holes upto 65 mm dia. in any RCC members by
diamond Core Cutting machine including disposing the
debries. Upto 750. Depthand Including EPOXY based
Rupees Four Hundred Fifty
42 10.00 water proofing compound for sealing the joints around nos 454.50
Four And Paise Fifty Only
the pipes, nominal reinforcement wherever required,
scaffolding and labour charges for working at all levels,
leads and heights
Making holes upto 50 mm dia. in any RCC members by
diamond Core Cutting machine including disposing the
debries. Upto 750. Depthand Including EPOXY based Rupees Four Hundred
43 10.00 water proofing compound for sealing the joints around nos 419.15 Nineteen And Paise Fifteen
the pipes, nominal reinforcement wherever required, Only
scaffolding and labour charges for working at all levels,
leads and heights
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Structural steel work (Confirming to IS 4923-1997)
riveted, bolted or welded in builtup for all type sections,
Rupees One Hundred Thirty
in framed work, including cutting, hoisting, fixing in
44 329.88 kg 131.83 One And Paise Eighty Three
position and applying a priming coat of approved steel
primer all complete as per the structural designs and
directions of Engineer in charge
Supplying, Installation, Testing of Electric driven Main Fire
Hydrant pump suitable for automatic operation and
consisting of following: Horizontal type, centrifugal End
Rupees Three Lakh(s)
Suction pump of cast iron body & bronze impeller,
Twelve Thousand Two
45 1.00 mechanical seal to ensure a minimum pressure of 3.5 kg / Nos. 3,12,269.28
Hundred Sixty Nine And
sq.cm. at highest and farthest outlet at specified flow of
Paise Twenty Eight Only
1620 LPM @ 70 MTR. head with M.S. fabricated common
base plate, coupling, coupling guard, foundation bolts etc.
Supplying, Installation, Testing of Jockey Pump 260 LPM Rupees One Lakh(s)
@ 70 M Head. Horizontal Centrifugal End Suction. with Thirteen Thousand Two
M.S. fabricated common base plate, coupling, coupling Hundred Ninety And Paise
guard, foundation bolts etc. as required Thirty Nine Only
Supplying, Installation, Testing Diesel Engine driven
Standby Pumping System complete with, diesel engine, Rupees Six Lakh(s) One
Back Pull-out Type Single Stage, Self Priming, Centrifugal Thousand Four Hundred
Pump, Flow Capacity: 1620 LMP @ 70 mtr. Eighty Two And Paise
Diesel Engine includes 100 ltr diesel tank, battery, battery Seventy Eight Only
charger, engine oil and coolant.
Supplying, Installation, Testing and commissioning of
Rupees One Lakh(s) Forty
cubical type floor mounted power cum Fire Pump control
Five Thousand Two
48 1.00 panel complete with relays, contractors, indicating lamps, Nos. 1,45,245.58
Hundred Forty Five And
fuses, instruments manual isolator & auxillary switch
Paise Fifty Eight Only
including connections complete as required.
Supplying, installation, testing and commissioning of
Rupees Nine Thousand Six
C.I.Butter fly valve conforming to I.S:13095 class PN
49 12.00 Nos. 9,652.07 Hundred Fifty Two And
Supplying, installation, testing and commissioning of
Rupees Six Thousand Three
C.I.Butter fly valve conforming to I.S:13095 class PN
50 4.00 Nos. 6,341.79 Hundred Forty One And
Paise Seventy Nine Only
Supplying, installation, testing and commissioning of
Rupees Five Thousand
C.I.Butter fly valve conforming to I.S:13095 class PN
51 2.00 Nos. 5,098.99 Ninety Eight And Paise
Ninety Eight Only
Supplying, installation, testing and commissioning of
Rupees Three Thousand
C.I.Butter fly valve conforming to I.S:13095 class PN
52 6.00 Nos. 3,856.18 Eight Hundred Fifty Six And
Paise Eighteen Only
Supplying, installation, testing and commissioning of C.I.
Rupees Twelve Thousand
Dual plate type Non-Return Valve class PN 10 rating with
53 3.00 Nos. 12,387.40 Three Hundred Eighty
fittings, flanges, nutbolts, washers, gaskets etc.
Seven And Paise Forty Only
Supplying, installation, testing and commissioning of C.I.
Rupees Eight Thousand
Dual plate type Non-Return Valve class PN 10 rating with
54 1.00 Nos. 8,147.92 One Hundred Forty Seven
fittings, flanges, nutbolts, washers, gaskets etc.
And Paise Ninety Two Only
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Rupees Three Thousand Six
Providing and fixing, testing of Pressure Gauge with
55 4.00 Nos. 3,600.65 Hundred And Paise Sixty
Rupees Two Thousand
56 3.00 Providing and fixing, testing of Pressure Switch Nos. 2,381.08 Three Hundred Eighty One
And Paise Seven Only
Supply, Installation, testing and commissioning of Forged Rupees One Thousand One
57 6.00 Brass Ball Valve with PN16 rating with SS ball inside. Size:- Nos. 1,196.35 Hundred Ninety Six And
25mm Paise Thirty Four Only
Rupees Thirty Three
Supply, Installation, testing and commissioning of PVC
Thousand Four Hundred
58 1.00 priming tank with capacity of 500 Liter. The rates are Job 33,439.59
Thirty Nine And Paise Fifty
included with tank connection.Including Pipe 25 MM.
Rupees Nineteen Thousand
Supply, Installation, testing and commissioning of CI Foot
Seven Hundred Seventy
Four And Paise Fifty Four
Supply, Installation, testing and commissioning of CI Foot Rupees Nine Thousand Five
60 1.00 Valve Nos. 9,582.38 Hundred Eighty Two And
100 mm dia Paise Thirty Eight Only
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe line for hydrant & sprinkler
system suspended ceiling or wall with necessary fittings
like elbow tee, long radius bend, flanges, supports,
Rupees Four Thousand
hangers. incl. jointing the pipes & fittings with standard
61 12.00 Mtr. 4,704.08 Seven Hundred Four And
procedure of welding. excl painting the pipe line with
Paise Eight Only
three coat of synthetic enamel over base coat of redoxide
paint, incl. testing the whole piping net work at rate of
kg/cm2 etc.comp. as directed by the engg. Incharge.
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe line for hydrant & sprinkler
system suspended ceiling or wall with necessary fittings
like elbow tee, long radius bend, flanges, supports, Rupees Three Thousand
hangers.incl.jointing the pipes & fittings with standard Two Hundred Eighty Four
procedure of welding. excl painting the pipe line with And Paise Seventy Two
three coat of synthetic enamel over base coat of redoxide Only
paint, incl. testing the whole piping net work at rate of
kg / cm2 etc.comp. as directed by the engg. Incharge.
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe line for hydrant & sprinkler
system suspended ceiling or wall with necessary fittings
like elbow tee, long radius bend, flanges, supports,
Rupees Two Thousand Two
hangers.incl.jointing the pipes & fittings with standard
63 120.00 Mtr. 2,224.27 Hundred Twenty Four And
procedure of welding. excl painting the pipe line with
Paise Twenty Seven Only
three coat of synthetic enamel over base coat of redoxide
paint, incl. testing the whole piping net work at rate of
kg / cm2 etc.comp. as directed by the engg. Incharge.
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe line for hydrant & sprinkler
system suspended ceiling or wall with necessary fittings
like elbow tee, long radius bend, flanges, supports,
Rupees One Thousand Five
hangers.incl.jointing the pipes & fittings with standard
64 60.00 Mtr. 1,581.96 Hundred Eighty One And
procedure of welding. excl painting the pipe line with
Paise Ninety Six Only
three coat of synthetic enamel over base coat of redoxide
paint, incl. testing the whole piping net work at rate of
kg / cm2 etc.comp. as directed by the engg. Incharge.
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe line for hydrant & sprinkler
system suspended ceiling or wall with necessary fittings
like elbow tee, long radius bend, flanges, supports,
Rupees Nine Hundred
hangers.incl.jointing the pipes & fittings with standard
65 132.00 Mtr. 993.08 Ninety Three And Paise
procedure of welding. excl painting the pipe line with
three coat of synthetic enamel over base coat of redoxide
paint, incl. testing the whole piping net work at rate of
kg / cm2 etc.comp. as directed by the engg. Incharge.
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe line for hydrant & sprinkler
system suspended ceiling or wall with necessary fittings
like elbow tee, long radius bend, flanges, supports,
Rupees Seven Hundred
hangers.incl.jointing the pipes & fittings with standard
66 144.00 Mtr. 720.13 Twenty And Paise Thirteen
procedure of welding. excl painting the pipe line with
three coat of synthetic enamel over base coat of redoxide
paint, incl. testing the whole piping net work at rate of
kg / cm2 etc.comp. as directed by the engg. Incharge.
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe line for hydrant & sprinkler
system suspended ceiling or wall with necessary fittings
like elbow tee, long radius bend, flanges, supports,
hangers.incl.jointing the pipes & fittings with standard Rupees Six Hundred Fifteen
procedure of welding. excl painting the pipe line with And Paise Sixty Only
three coat of synthetic enamel over base coat of redoxide
paint, incl. testing the whole piping net work at rate of
kg / cm2 etc.comp. as directed by the engg. Incharge.
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe line for hydrant & sprinkler
system suspended ceiling or wall with necessary fittings
like elbow tee, long radius bend, flanges, supports,
Rupees Four Hundred
hangers.incl.jointing the pipes & fittings with standard
68 168.00 Mtr. 483.18 Eighty Three And Paise
procedure of welding. excl painting the pipe line with
three coat of synthetic enamel over base coat of redoxide
paint, incl. testing the whole piping net work at rate of
kg / cm2 etc.comp. as directed by the engg. Incharge.
Supply, Installation, testing and commissioning of MS
HEAVY " C class" ERW pipe. For Hydrant system Under
Rupees Four Thousand
ground line with necessary fitting like elbow, tee, long
69 30.00 Mtr. 4,076.87 Seventy Six And Paise
radius bend, The pipe must be jointed with welded
Eighty Six Only
operation and 2layer coating
Supplying, Installation, Testing Of SPRINKLER 68 Deg Rupees Three Hundred
(Pendet) Sixty And Paise Six Only
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Supplying, Installation, Testing Of SPRINKLER 68 Deg (side Rupees Three Hundred
wall) Sixty And Paise Six Only
Rupees One Thousand Five
Supply, Installation, testing and commissioning of Flexible
72 174.00 Nos. 1,568.03 Hundred Sixty Eight And
Dop Inculding Rosset Plate
FIRE HYDRANT VALVE, SINGLE OBLIQUE
OUTLET, Body / female inst. Oblique outlet (63mm size)
with Pull out type Lug made of Stainless Steel, IS: 3444 Gr- Rupees Six Thousand Seven
73 16.00 1, 75mm N.B. Flanged inlet, Spindle made of S.S. 304 (IS: Nos. 6,783.16 Hundred Eighty Three And
6603) and Hand wheel made of Cast Iron, Complete with Paise Sixteen Only
PVC blank cap & chain, BEARING IS: 5290 MARK, Flange
Dimension: O.D. 200mm, PCD 160mm
HOSE BOX -Made of 16 gauge Mild with lock, keys and a Rupees Five Thousand Fifty
74 14.00 break glass recess for keys Painted Fire Red outside Nos. 5,052.53 Two And Paise Fifty Two
"SINGLE Door Fire HOSE Box" Only
Rupees Four Thousand
RRL TYPE A FLEXIBLE FIRE FIGHTING DELIVERY HOSE, Dia. Four Hundred Seventy One
63mm X 15mtr. Length. And Paise Seventy Seven
Rupees One Thousand
Eight Hundred Ninety
76 14.00 "BRANCH PIPE'' - SHORT"Made of SS. Nos. 1,893.25
Three And Paise Twenty
"HOSE REEL", WALL MOUNTING TYPE Drum complete
with wall mounting bracket, Complete with 20 mm bore X Rupees Seven Thousand Six
77 14.00 30mtr long, High Pressure Braided Rubber Hose as per Nos. 7,689.13 Hundred Eighty Nine And
IS:444 Type II, Fitted with 6mm bore PVC shut-off nozzle Paise Thirteen Only
Without Inlet Valve GENERALLY CONFORMING TO IS:
Rupees One Thousand Nine
Supplying, installing, testing and commissioning of AIR
78 6.00 Nos. 1,939.71 Hundred Thirty Nine And
Paise Seventy Only
Rupees Two Thousand Four
79 20.00 Supply, Installation of ABC type fire Extinguisher 6 KG Nos. 2,474.00
Hundred Seventy Four Only
Rupees Five Thousand Five
80 20.00 Supply, Installation of CO2 type fire Extinguisher 4.5 KG Nos. 5,517.13 Hundred Seventeen And
Paise Twelve Only
Rupees Nine Thousand
Supply, Installation and Testing of FIRE bridge 4 way inlet Seven Hundred Thirty
with inbilt NRV with rubber cap Three And Paise Thirty
Rupees Six Hundred Thirty
Providing and fixing of alarm and trigger switch system
82 12.00 Nos. 638.83 Eight And Paise Eighty
Rupees Six Hundred Thirty
Providing and fixing of alarm and trigger switch system
83 12.00 Nos. 638.83 Eight And Paise Eighty
Rupees Four Hundred
Providing and fixing of alarm and trigger switch system
84 12.00 Nos. 499.45 Ninety Nine And Paise
PUMP ON/OFF SWITCH
Forty Four Only
Rupees Six Thousand Five
Providing and fixing of alarm and trigger switch system
85 1.00 Nos. 6,504.40 Hundred Four And Paise
Rupees One Hundred
Providing and fixing of alarm and trigger switch system
86 500.00 Mtr. 185.84 Eighty Five And Paise Eighty
Supply, Installation of 1.5 sq.mm 3 core Armoured Cable
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Rupees One Hundred Forty
Providing and fixing of alarm and trigger switch system
87 500.00 Mtr. 145.19 Five And Paise Nineteen
Supply, Installation of 1.5 sq.mm 2 core Armoured Cable
Supply, Installation, Testing and Commissioning of
Rupees Two Hundred
photolumicent foam sheet based fire signages. LIKE (CO2,
88 64.00 Nos. 290.38 Ninety And Paise Thirty
ABC, FIRE EXIT)
Fire Alarm Rupees Four Lakh(s) Fifty
89 1.00 Supply, Installation and Testing of ADDRESSABLE 2 LOOP Nos. 4,57,631.00 Seven Thousand Six
ALARM PANEL Hundred Thirty One Only
Rupees Four Thousand
90 10.00 Supply, Installation and Testing of ADDRESSABLE MCP Nos. 4,959.61 Nine Hundred Fifty Nine
And Paise Sixty Only
Rupees Four Thousand One
91 10.00 Supply, Installation and Testing of ADDRESSABLE HOOTER Nos. 4,123.33 Hundred Twenty Three And
Paise Thirty Two Only
Rupees Three Thousand
Supply, Installation and Testing of ADDRESSABLE SMOKE
92 320.00 Nos. 3,821.34 Eight Hundred Twenty One
And Paise Thirty Four Only
Rupees Five Thousand
Three Hundred Seventy
93 10.00 Supply, Installation and Testing of CONTROL MODULE Nos. 5,377.75
Seven And Paise Seventy
Rupees One Hundred Forty
94 2,000.00 Supply, Installation of 1.5 sq.mm 2 core Armoured Cable Mtr. 145.19 Five And Paise Nineteen
Charges for Liasoning with CFO and getting all approvals
and permissions. Fire opinion & NOC 's required for fire Rupees Two Lakh(s) Eighty
fighting at various stages & after completion of the Four Thousand Five
project. (All official and receipted payments would be Hundred Sixty Seven And
submitted and Re-imbursed) Taking approval /NOC form Paise Fifty Only
Design and drawing work of fire fighting and fire alarm
Rupees One Lakh(s) Sixteen
work, elctrcial work, and ceiling work, pump room and
96 1.00 Job 1,16,150.00 Thousand One Hundred
Pre NOC work and NOC Cerficarte from Chief Officer
collection and submited to department.
Point wiring for Light/ Bell with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires up to
10 mtr length, in below type of pipe erected with 6A
Modular type switch/ bell push & accessories and earth
Rupees Four Hundred
continuity of following type, erected on PVC/ Metallic/
97 130.00 Pt. 485.81 Eighty Five And Paise Eighty
Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on/
in wall/ ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose/ H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete Cat. III
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Point wiring for Individual Plug with & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC/
Metallic/ Wooden box covered with appropriate front Rupees Five Hundred Ten
plate modules erected on/ in wall/ ceiling as per pipe And Paise Five Only
erected with following type of accessories.[I] For 6A Plug
and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board.(f) with medium class Rigid
PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. III
Point wiring for Individual Plug with & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC/
Rupees Seven Hundred
Metallic/ Wooden box covered with appropriate front
99 30.00 Pt. 745.38 Forty Five And Paise Thirty
plate modules erected on/ in wall/ ceiling as per pipe
erected with following type of accessories. [II] For 16A
Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from
mcb db board.(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete
Providing following type of Modular Type Accessories
mounted with PVC/ Metallic/ Wooden box, single
mounting base frame covered with textured/ Rupees Twenty Five And
metallic/white front plate, modules erected with Paise Twenty Five Only
necessary connections as per site situation directed by
Engineer In charge. (7) Blank Plate Single Cat.III
Point wiring for on board Looped Plug with 6A Modular
type switch & 5 pin socket erected on PVC/ Metallic/ Rupees Two Hundred Fifty
101 25.00 Wooden box, single mounting base frame covered with Pt. 257.55 Seven And Paise Fifty Five
textured/ metallic/ white front plate modules erected on/ Only
in wall/ ceiling with following type accessories Cat. III
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction Rupees Twenty Four And
boxes fixed with adhesive solution & Clamps with Paise Twenty Four Only
following dia of pipes, in approved manner as directed.
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction Rupees Thirty Three And
boxes fixed with adhesive solution & Clamps with Paise Thirty Three Only
following dia of pipes, in approved manner as directed.(b)
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction Rupees Fifty Four And Paise
boxes fixed with adhesive solution & Clamps with Fifty Four Only
following dia of pipes, in approved manner as directed.(c)
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made
of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more than 0.95,
THD < 15%, Rupees Two Hundred
105 30.00 CCT 3000 K to 6500K, Ea. 295.93 Ninety Five And Paise
Luminaire efficacy> 85 lumens/watt,LED Ninety Three Only
LED driver efficiency > 85 %
(fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Tube
Light with integral driver (iii) 18-20 Watts, Surge - 2KV,IP-
20, conventional 4 feet Cat-lll
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made
of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated
and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company
Rupees Seven Hundred
160V to 270V,Power Factor more than 0.9, THD < 15 %,
106 15.00 Ea. 758.51 Fifty Eight And Paise Fifty
CCT 3000 K to 6500K, Luminaire efficacy>
lumens/watt, LED driver efficiency > 85 % (fitting required
LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) (A) Square/ Circular
shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV Cat-III
Supplying & erecting approved make low noise
Rupees One Thousand
decorative exhaust fan having square frame ABS body
107 4.00 Ea. 1,366.53 Three Hundred Sixty Six
with inbuilt lowers & square frame. 250mm with
And Paise Fifty Three Only
Providing and erecting Miniature circuit breaker single
pole 6A to 25A suitable to operate on 240 V A.C. system Rupees One Hundred
108 30.00 and having breaking capacity 10 KA to be erected in Ea. 112.11 Twelve And Paise Eleven
existing box. confirming to IS 8828/1996 with ISI Mark Only
Providing & erecting 415 V MCB Four Pole for Motor &
Rupees Seven Hundred
Inductive Load (C Curve) having 10KA breaking capacity &
109 2.00 Ea. 737.30 Thirty Seven And Paise
confirms to IS :8828 in existing box having following
capacity (c)63 Amp Cat.III
Providing & erecting 415 V MCB Four Pole for Motor &
Rupees Six Hundred Sixty
Inductive Load (C Curve) having 10KA breaking capacity &
110 4.00 Ea. 668.62 Eight And Paise Sixty Two
confirms to IS :8828 in existing box having following
capacity (b)40 Amp. Cat.III
providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
Rupees Two Thousand Two
operation on single phase 240 V,50Hz. having
111 5.00 Ea. 2,235.13 Hundred Thirty Five And
characteristic of quick action & tripping with all advance
Paise Thirteen Only
feature & do not incorporate any electronic component.
for following Max. rating erected as directed (ii) 40Amps.
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
Rupees Two Thousand Six
operation on single phase 240 V,50Hz. having
112 2.00 Ea. 2,654.28 Hundred Fifty Four And
characteristic of quick action & tripping with all advance
Paise Twenty Eight Only
feature & do not incorporate any electronic component.
for following Max. rating erected as directed (iii)
Amps. DP Cat. III
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush/ surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
Rupees Seven Hundred
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
113 2.00 Ea. 702.96 Two And Paise Ninety Six
appropriate nos. of MCBs. (The DBs should be used of
same company of MCB to be used) suitable for (A) single
phase incoming and horizontal single phase outgoing (b)
sheet steel double door (iii)8 way
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush/ surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house Rupees Three Thousand
114 1.00 appropriate nos. of MCBs. (The DBs should be used of Ea 3,412.79 Four Hundred Twelve And
same company of MCB to be used) suitable for (B) three Paise Seventy Nine Only
phase incoming and single phase horizontal type outgoing
Per phase isolation type (PPI) (b) sheet steel double door
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking capacity
ICU of 25 KA. at 415 V,having normal current rating up to Rupees Six Thousand One
115 6.00 25 A to 100A. with Fixed thermal & magnetic release Ea. 6,173.12 Hundred Seventy Three
suitable to work on A.C. supply 50 c/s. with all internal And Paise Twelve Only
connections, spreader tinned copper & complete erected
in existing 16 G.M.S. housing. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking capacity
ICU of 35 KA. and above at 415 V . having normal current Rupees Twenty Thousand
116 1.00 rating 250A. with variable thermal & magnetic release Ea. 20,946.39 Nine Hundred Forty Six And
suitable to work on A.C.supply 50 c/s. with all internal Paise Thirty Nine Only
connections, spreader tinned copper & complete erected
in existing 16 G.M.S. housing. ICS=100% of ICU only Cat III
Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected concealed in/flushed
Rupees Sixty Two And Paise
117 1,900.00 on wall/ceiling, with 1.5 sq. mm copper conductor FRLS Mtr 62.62
PVC insulated stranded wire of green colour for earth
continuity of following size.(A) with medium class Rigid
PVC pipe and accessories.(a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected concealed in/flushed
Rupees Eighty Two And
118 1,800.00 on wall/ceiling, with 1.5 sq. mm copper conductor FRLS Mtr 82.82
Paise Eighty Two Only
PVC insulated stranded wire of green colour for earth
continuity of following size.(A) with medium class Rigid
PVC pipe and accessories.(b) 2 wire 2.5 sq. mm)
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in/ on wall/ ceiling Rupees One Hundred
119 960.00 with 2.5 sq. mm copper conductor FRLS PVC insulated Mtr 112.11 Twelve And Paise Eleven
stranded wire of green colour for earth continuity of Only
following size(A) with medium class Rigid PVC pipe and
accessories.(a) 2 wire 4 sq. mm
Supplying & erecting Flexible PVC insulated multistrand
multicore 1.1 KV grade ISI marked Copper Wires of Rupees Seventy Seven And
following Size to be erected as directed. (h) 2.50 Sq.mm 3 Paise Seventy Seven Only
core round PVC sheathed
Providing & erecting open well horizontal mono block
pump set with cast iron body, complete for three phase
Rupees Eighteen Thousand
submersible motor having [D] For 5 HP 3 phase open well
121 1.00 Ea. 18,746.61 Seven Hundred Forty Six
horizontal mono block pump set suitable for 1350 LPM to
And Paise Sixty One Only
310 LPM @ 10 to 42 Mtr head suitable for 50/65 mm dia
delivery pipe Cat.II
Supplying & erecting approved make motor control
cubical panel [Star delta] made from 16G CRCA sheet duly
epoxy powder painted inside and outside with hinged
doors and locking with suitable size of ON - OFF isolator
(AC 3/ 23 duty) main fuses. Digital volt and current meter
(in a single unit) with micro controller based control unit
and current sensing single phasing preventer electronic
overload protection, over voltage (Programmable)
Rupees Seven Thousand
protection and under voltage (Programmable) protection,
122 1.00 Ea. 7,250.79 Two Hundred Fifty And
prod less dry run protection programming facility for
Paise Seventy Nine Only
setting of all parameter like overload current, high
voltage limit, low voltage limit, dry run limit with digital
indication on seven segment LED display for any fault like
over load, high voltage, low voltage, dry running single
crimped, electronic star delta timer, feather touch start/
stop push buttons to be erected on angle iron frame.
Grouted on wall the contactors will be of L& T, Siemens,
BCH make only) (A) DOL up to 5.0 H.P.
Supplying & erecting approved make Automatic liquid
level controller 6A.as per instruction of Engineer in charge
Rupees Two Thousand
on site complete with wiring connection with existing
123 1.00 Ea 2,355.32 Three Hundred Fifty Five
wires, with copper conductor from pump to upper and
And Paise Thirty Two Only
lower tank.(Size Not less than 1.5 Sq MM) from pump to
upper and lower tank with ISI marked Rigid PVC Pipe.
Providing and erecting ISI marked PVC insulated PVC Rupees One Hundred Forty
124 250.00 Sheathed Flat flexible Submersible copper cable Mtr 146.45 Six And Paise Forty Five
approved make of following Size. (C) 3 Core x 4 Sq. mm Only
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be Rupees One Thousand One
125 185.00 laid on wall with necessary clamps or in existing trench / Mtr 1,161.50 Hundred Sixty One And
pipe of following size of cables (I) 3 1/2 core 240 Sq. mm Paise Fifty Only
(120 Sq. mm 1/2 core) for fire pump main incoming
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be Rupees Five Hundred Thirty
126 38.00 laid on wall with necessary clamps or in existing trench / Mtr 534.29 Four And Paise Twenty
pipe of following size of cables (F) 3 1/2 core 120 Sq. mm Nine Only
(70 Sq. mm 1/2 core)
Quantity Description of item Unit Total Amount
Quantity Description of item Unit Total Amount
No. Rate in Figures Rate in Words
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be Rupees Four Hundred
127 33.00 laid on wall with necessary clamps or in existing trench / Mtr 484.80 Eighty Four And Paise
pipe of following size of cables (E) 3 1/2 core 95 Sq. mm Eighty Only
(50 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be Rupees Two Hundred
128 35.00 laid on wall with necessary clamps or in existing trench / Mtr 217.15 Seventeen And Paise
pipe of following size of cables (B) 3 1/2 core 35 Sq. mm Fifteen Only
(16 Sq. mm 1/2 core)
Removing & Refixing pre-cast Rubber Dye / steel Dye Rupees Three Hundred
129 600.00 inter locking concrete block 60mm thick as per Approved smt 326.01 Twenty Six And Paise One
By Engineer in charge. Only
Providing & Fixing Rebaring -12 mm 150 mm depth with Rupees One Hundred Fifty
Hilti Chemical usingas per apprved by Engineer in charge . Six And Paise Eighty Only
Providing & Fixing Rebqring -16 mm 150 mm depth with Rupees Two Hundred
131 40.00 Hilti Chemical using as per apprved by Engineer in charge No 278.76 Seventy Eight And Paise
. Seventy Six Only
Amount in Words Rupees One Crore Nineteen Lakh(s) Ninety Nine Thousand Seven Hundred Ninety And Paise Eighty Nine Only
(A) Total tender amount Rs.
(B) Rebate on above tender amount (if any) (% in figure)________ (% in Rs.
(C) Net tendered amount (A-B) Rs.
(D) Net Tendered amount (In words): Rupees
1 All works shall be carried out as per Public Work Department and other specification of division or as directed.
2 All the columns in the contractor be filled in ink and the total of the entries in the last column should be struck by the contractor under his signature.
Rates quoted include clearance of site (prior commncement of work and its close). In all respect and held good for work under all condition, site,
moisture, weather etc.
Testing of materials shall be as per statement attached with the specifications. The material shall be tested in GERI testing charges @ 1% of the
4 amount as per the schedule -B shall be recovered from the contractor from the running bill as per G.R. (E&R) deptt. No. TKC/1085/4-S dt. 20-12-91.
Test results other than GERI will not be accepted.
1% of the construction cost of shall be deducted from bill amount of contract, as per hthe building and other construction worker's welfare cess act.
5 1996. (Labour & Employment department letter No. C.W.A. - 2004 - 1831- M(3), Dt. 09/12/2005, Notification of labour & Employment Department.
Dt. 03-01-05- and Labour & Employment Department. letter No.C.W.A. - 2004 - 1831- M(3), Dt.14/12/2005)
Quantity, rates & working of items are as per estimates and calculation in the schedule "B" are arithmetically checked and found correct.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 NIT Kantharpur.pdf
02.sbd.pdf
03.schedule b.pdf
04.index specification.pdf
05.civil specification.pdf
06.electrical specification.pdf
07. BUILDING SPECIFICATION PART-I.pdf
07. BUILDING SPECIFICATION PART-II.pdf
07. BUILDING SPECIFICATION PART-III.pdf
07. BUILDING SPECIFICATION PART-IV.pdf
08.fire fighting specification.pdf
09. DEFECT LIABILITY PERIOD GR.pdf
10.site visit affidavit.pdf
11. GRs SBD with Index.pdf
12.GROUND FLOOR _FA_21DEC25 (1).pdf
13.UPPER LEVEL _FA_21DEC25 (1).pdf
14..LOWER LEVEL _FA_21DEC25 (1).pdf
15.-Tender Validity Dt.10-5-2013.pdf
16-Lap Length GR Dt.15-2-2017.pdf
17.-Single Tender GR Dt.18-2-2017.pdf
18-Standards for Cement Consumption Dt.11-5-2017.pdf
19.-Testing Schedule.pdf
20. MAKE LIST.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .