Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC C 23 CC | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹4.9 L+₹6,843.57 (1.42%)Rejected-Finance 20 C RAGHUVANSH ENCLAVE KALIDAS ROAD DEHRADUN | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹5.4 L+₹59,802.62 (12.4%)Rejected-Finance DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹5.8 L+₹93,654.32 (19.4%)Rejected-Finance 3491 14 HARIPURA DHAPAI ROAD AMRITSAR | AMRITSAR | PUNJAB | 143001 | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹6.3 L+₹1.5 L (30.9%)Rejected-Finance DEHRADUN | L5 | Rejected-Finance 5TH LOWEST |
| Sl No | Description | Qty | Unit | TARUN ENGINEERING WORKS L3 | shreyansh construction L2 | RAMAN CONSTRUCTION CO. L1 | AMARJEET SINGH AND CO. L4 | S.P CONSTRUCTION CO. L6 | Malik Associates L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material and removing unserviceable material outside of A1 defence land complete all as specified and directed.
Note :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . (b) The rates quoted shall deemed to be included for these items | 65 | sqm | 50 ₹3,250 | 10 ₹650 Lowest | 88 ₹5,720 | 25 ₹1,625 | 300 ₹19,500 | 95 ₹6,175 |
| 2.00 | M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface.
Note :- (i)The work is required to be carried out at non-accessible roof for double storey . (ii)The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these items. | 65 | Sqm | 40 ₹2,600 | 150 ₹9,750 | 31 ₹2,015 Lowest | 65 ₹4,225 | 65 ₹4,225 | 50 ₹3,250 |
| 3.00 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (mixed as per manufacturer direction ) and finishing the surface even and smooth without using extra cement as in roof padding over a one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be applied for bonding of new concrete/ mortar to old surface. of complete as per direction of Engr-in-Charge..
Note :-
1. Liquid water proofing compound will be measured and paid separately.
2. The work is required to be carried out at non-accessible roof for double storey The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items. | 2.6 | cum | 5,000 ₹13,000 | 5,000 ₹13,000 | 5,200 ₹13,520 | 3,500 ₹9,100 Lowest | 7,500 ₹19,500 | 6,000 ₹15,600 |
| 4.00 | M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-
(a) Applying evenly a tack coat @ 1.2 kg/Sqm using 85/25 grade of industrial hot blown bitumen on primed surface of roof by applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.
(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.5 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer
(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
Note :
1. The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only
2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.) | 65 | Sqm | 440 ₹28,600 | 400 ₹26,000 | 351 ₹22,815 Lowest | 495 ₹32,175 | 600 ₹39,000 | 450 ₹29,250 |
| 5.00 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for. | 3.83 | Cum | 300 ₹1,149 | 100 ₹383 Lowest | 299 ₹1,145.17 | 410 ₹1,570.3 | 500 ₹1,915 | 100 ₹383 Lowest |
| 6.00 | M&L for 75 mm 1:3:6 type C2 ( using 40 mm graded stone aggregate) as plinth protection/paving finish even and smooth without using extra cement. | 21 | Sqm | 300 ₹6,300 | 280 ₹5,880 | 307 ₹6,447 | 250 ₹5,250 Lowest | 350 ₹7,350 | 350 ₹7,350 |
| 7.00 | M & L for Plain Cement Concrete Type D2 1:4:8 (using 20 mm graded stone aggregate) in sub base of flooring/ hard standing /footpath | 2.25 | cum | 3,500 ₹7,875 | 4,500 ₹10,125 | 3,250 ₹7,312.5 | 120 ₹270 Lowest | 6,500 ₹14,625 | 3,600 ₹8,100 |
| 8.00 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) | 0.32 | Cum | 300 ₹96 | 100 ₹32 | 319 ₹102.08 | 410 ₹131.2 | 600 ₹192 | 60 ₹19.2 Lowest |
| 9.00 | M&L providing precast cement concrete for manhole cover slabs and similar work type B-1 (1:2:4) using 20mm graded aggregate set in cement mortar (1:4) all as specified and directed | 0.32 | Cum | 6,000 ₹1,920 | 5,000 ₹1,600 | 6,250 ₹2,000 | 8,450 ₹2,704 | 7,000 ₹2,240 | 4,500 ₹1,440 Lowest |
| 10.00 | M&L for mild steel bars deformed or twisted 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips | 64.8 | Kg | 75 ₹4,860 | 90 ₹5,832 | 85 ₹5,508 | 65 ₹4,212 Lowest | 140 ₹9,072 | 68 ₹4,406.4 |
Tender Value
₹9.0 L
EMD Value
₹17,400
Closing Date
24 Apr 2025, 6:00 pmClosed
AGE (I) RAIWALA
AGE (I) RAIWALA
SPL REPAIR TO BLDG NO P-233 (UPPER PUMP HOUSE) AT RAIWALA MIL STN UNDER AGE (I) RAIWALA
2025_MES_703025_1
8962/E8
Open Tender
Civil Works
Works
150 days
AGE (I) Raiwala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) RAIWALA
₹17,400
Yes
30 Oct 2025
29 Mar 2025
26 Apr 2025
29 Mar 2025
24 Apr 2025
11 Apr 2025
29 Mar 2025 - 10 Apr 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .