LAC-ADS-LAC-ADS-2022-23 - THalassery LAC-Electrification of New Mahe PHC Sub Centre - Mangad Health and amp Wellness centre-General Electrical Work (Re-Tender)
2026_LSGD_855211_4
DB/TN/1(2-B)/26-27
Open Tender
Electrical Works
90 days
Kannur
Please refer tender documents.
7 documents required · 7 mandatory
₹1,015
Yes
₹11,489
Yes
10 Jun 2026
10 Jun 2026
20 Jun 2026
10 Jun 2026
19 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1ELETRIFICATION | ||||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | - | each | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | OD33888/2025-2026:Supply ,Conveyance, installation, testing and commissioning of 12 W LED Bulkhead Light fittings Lumen output - 600, Housing - High pressure die cast aluminum directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.(LUKER STYX ECO BULKHEAD LIGHT 12W LBKOVSL12/equivalent) | - | each | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | OD56914/2025-2026:Supply Conveyance, installation, testing and commissioning of 4800 lumen LED Flood light output greater than 120 lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/ Lumilled/ Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | - | each | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | - | each | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | OD33887/2025-2026:Supply and providing the following types and power rated lamps in the existing fittings as required. B22 LED bulb 9W | - | each | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | - | each | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) | - | each | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | - | each | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_1445403.xls
BOQ • 0.34 MB
SBDnewmahe.pdf
Tender Documents • 2.51 MB
NITnewmahe.pdf
Other Document • 1.30 MB
Download all tender documents and submit your bid