Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.4 LAccepted-AOC VILLAGE P O GAHLIAN TEHSIL DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC Award | |
| 2 | L2₹58.7 L+₹1.3 L (2.32%)Rejected-Finance NO 1 HPPWD DIVISION DHARAMSHALA HIMACHAL PRADESH | KANGRA | HIMACHAL PRADESH | 176001 | L2 | Rejected-Finance Lowest 3 | |
| 3 | L3₹60.7 L+₹3.3 L (5.75%)Rejected-Finance | L3 | Rejected-Finance Lowest 2 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Fulfill Criteria | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Fulfill Criteria |
Tender Value
₹44.2 L
EMD Value
₹73,800
Closing Date
13 May 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
HP PWD Division Tanda at Nagrota Bagwan
Construction of Govt. Senior Secondary School at Hatwas in District Kangra (Himachal Pradesh). (SH-Construction of 4 Nos. class room including stair case and Verandah).
2022_PWD_59975_2
PWD- Civil-1107-37-Tanda
Open Tender
Civil Works - Buildings
Item Rate
180 days
Nagrota Bagwan
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,000
₹73,800
30 Aug 2022
28 Apr 2022
13 May 2022
28 Apr 2022
13 May 2022
28 Apr 2022
120 days
Amount
Excavation in foundation, trenches etc. in earth work in all classification of soil such as pick work, jumper work, pick jumper work, blasting work, jumper blasting work, soft and hard blasting and saturated soil, de-watering, including wedging out rocks where blasting work is prohibited, chiseling or any other mixed variety of soil, de-watering and/or removal of slush and incidentals, lift upto any heights, stacking the excavated soil not more than 3 mtrs (Three meters) clear from the edge of excavation and then retuning the stacked soil in15cm (Fifteen centimeter)layers, when required into plinths, sides of foundation etc; consolidating each deposited layer by ramming, watering and then disposing of all excavated earth as directed by the Engineer-in-Charge, within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Excavation in earth work and filling in 15cm (Fifteen centimetres) layers in foundation and plinth including ramming, watering and consolidation complete as per drawing includiing carriage of material as directed by the Engineer-in-Charge, within all leads, lifts of materials and other incidentals.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing form work with steel plates of 3.15mm (Three decimal one five millimeters) thick, welded with angle iron in frames of 30x30x5mm (Thirty into Thirty into Five millimeters), so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights/depths of propping and centring below supporting floor to ceiling and removal of the same for in-situ reinforced concrete and plain concrete work in Foundation footings, bases of columns and mass concrete within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing form work with steel plates of 3.15mm (Three decimal one five millimeters) thick, welded with angle iron in frames of 30x30x5mm (Thirty into Thirty into Five millimeters), so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights/depths of propping and centring below supporting floor to ceiling and removal of the same for in-situ reinforced concrete and plain concrete work in Flat surfaces such as soffits of suspended floors roofs, landings windows sills, cornices, arches, moulding, corbelling including curved surfaces where ever required as per Architectural drawing and the like floor etc. within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing form work with steel plates of 3.15mm (Three decimal one five millimeters) thick, welded with angle iron in frames of 30x30x5mm (Thirty into Thirty into Five millimeters), so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights/depths of propping and centring below supporting floor to ceiling and removal of the same for in-situ reinforced concrete and plain concrete work in beams cantilevers girders lintels window sills, cornices, arches corbelling including curved surfaces where ever required sides and soffits of beams haunchings cantilevers bressumers and lintels upto all depths within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing form work with steel plates of 3.15mm (Three decimal one five millimeters) thick, welded with angle iron in frames of 30x30x5mm (Thirty into Thirty into Five millimeters), so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights/depths of propping and centring below supporting floor to ceiling and removal of the same for in-situ reinforced concrete and plain concrete work in columns pillar posts and struts square rectangular polygonal in plan including mouldings, cornices etc; within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing form work with steel plates of 3.15mm (Three decimal fifteen millimeters) thick, welded with angle iron in frames of 30x30x5mm(Thirty into Thirty into Five millimeters),so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights and removal of the same for in-situ reinforced plain concrete work in stairs cases with slopping or stepped soffits, excluding, landing, within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing form work with steel plates of 3.15mm (Three decimal fifteen millimeters) thick, welded with angle iron in frames of 30x30x5mm(Thirty into Thirty into Five millimeters), so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights and removal of the same for in-situ reinforced plain concrete work in work in edge of slab and breaks in floors and walls under any thickness within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and laying cement concrete1:5:10 (One cement; Five sand; Ten graded broken/crushed stone aggregate 40mm (Forty milimetres) nominal size) and curing complete excluding cost of forms work in foundation and plinth within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and laying cement concrete1:6:12 (One cement; Six sand; Twelve graded broken/crushed stone aggregate 40mm (Forty milimetres) nominal size) mechanically mixed and curing complete excluding cost of forms work in foundation and plinth within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and laying cement concrete work of grade M-20 (M- twenty) mix design to obtain the minimum crushing strength of 20N/mm square with minimum cement contents of 330 kg (Three hundred thirty kilogram) per cubic meter to give an smooth surfaces mechanically mixed and vibrated including curing complete, excluding cost of form work and reinforcement for reinforced concrete work in foundation, footings, bases of columns and the like mass concrete within all leads, lifts of materials and other. Incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and laying cement concrete work of grade M-20 (M- twenty) mix design to obtain the minimum crushing strength of 20N/mm square with minimum cement contents of 310 kg (Three hundred ten kilogram) per cubic meter, mechanically mixed and vibrated including curing complete, excluding cost of form work and reinforcement for reinforced concrete work in Suspended floors, roofs, landings, shelves their supports balconies, beams, girder, bressumers and cantilevers including mouldings, cornices etc; within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and laying cement concrete work of grade M-20 (M- twenty) mix design to obtain the minimum crushing strength of 20N/mm square with minimum cement contents of 310 kg (Three hundred ten kilogram) per cubic meter, mechanically mixed and vibrated including curing complete, excluding cost of form work and reinforcement for reinforced concrete work in Columns, pillars posts and struts for all floors heights within all leads, lifts of materials and other. Incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and laying cement concrete work of grade M-20 (M- twenty) mix design to obtain the minimum crushing strength of 20N/mm square with minimum cement contents of 310 kg (Three hundred ten kilogram) per cubic meter, mechanically mixed and vibrated including curing complete, excluding cost of form work and reinforcement for reinforced concrete work in Stair cases (except spiral stair cases excluding landings, but including preparing of top surfaces and finishing of nosing upto all floor level within all leads, lifts of materials and other Incidentals
Providing and laying upto floor level reinforcement concrete work M-20 (M- twenty) mix design to obtain the minimum crushing strength of 20N/mm square with minimum cement contents of 310 kg (Three hundred ten kilogram) michanically mixed and virated to give smooth and even surfaces including centring and shuttering etc. but excluding the cost of reinforcement as in mouldings as in cornices, window sills etc not exceeding 15cm (Fifteen centimetres) in girth as per drawing and design complete upto floor all level within all leads, lifts of materials and other incidentals and as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing Tor steel reinforcement for reinforced cement concrete work including bending, binding and placing in position complete including cost of binding wires complete and other incidentals due for its completion for all floors within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge. .
Second class brick work using common burnt clay building bricks in super structure upto any floor level in cement mortar 1:6(One cement: Six sand) within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and laying Autoclayed cellular Aerated concrete blocks 200mm (Two hundred milimetre) thick confirming to IS:2185 (iii) 1984 bonded together with ploymer based mortar and finished with 12mm (Twelve milimetre) thick cement plaster 1:6 on both side complete as per HPPWD specifications or as directed by the Engineer-in-Charge, including carriage of material within all leads, lifts and other incidental.
Squared rubble masonry coursed with hard stone of approved quality in foundation and plinth including racking out joints in cement mortar 1:6(One cement: Six sand) within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing 35 mm (Thirty five milimetres) thick flush door shutters interior grade, commercial type, core of black-board construction with frame of first class hard wood and well matched commercial ply veneering with vertical grains of cross bands and face veneers on both faces of shutters. including black enamelled M.S. butt hinges within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing 19mm (Ninteen milimetres) thick water proof commercial board termite resistant of Uniply/Green ply or its equivalent ISI marked No. 1659 and all cut portions of the shutter have 6mm (Six milimetres) thick hard wood edging and the out side shutter of cup-board shall be finished with 1mm (One milimertre) thick lamination ISI marked No. 12823 and approved shade and sample of Kitvista of Kit Ply or its equivalent within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing 19mm (Ninteen milimetres) thick water proof commercial board in shelves/box for cup-board with butt joints and fixing with nails and screws etcetra complete and all the cut portion of the board shall have 6mm (Six milimetres) thick hard wood edging within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing 6mm (Six milimetres) thick ply wood lining with butt jointing and nails (frame work and cover fillets to be measured and paid for separately) within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing 19mm (Ninteen milimetres) thick commercial board water proof shutter for cup-board and P.G.I. lining of the of shutter inner side including fixing with nickel plated piano hinges with screws etc cojmplete all cut portion of the shutter finished with 6mm (Six milimetres) hard wood edging within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing preliminated phenol bounded black board with shade finish complete within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing cup-board shutter magnic catcher with necessary screws etcetra; within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing 65x35mm (Sixty five into Thirty five milimetres) special quality bright finished brass cup-board locks or ward robe locks with six levers including necessary screws etcetra complete (Indian make of approved quality) within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing M.S. Plain Grills of required pattern in frames of windows and ventilators etc with M.S. flats, square or round bars with round headed bolts and nuts etc or by screws within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge
Providing and fixing 300x16mm (Three hundred into Sixteen milimetres) size M.S. sliding door bolts bright finished or and black enamelled with nut and screws etcetra within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing M.S. tower bolts (barrel type) with necessary screws etcetra complete within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
200x10mm (Two hundred into Ten milimetres) size
150x10mm (One hundred fifty into Ten milimetres) size
Providing and fixing M.S. handles with necessary screws etcetra complete within all leads, lifts of materials and other incidentals, as per approved drawing, design and as directed by the Engineer-in-Charge.
125mm (One hundred twenty five milimetres) size
100mm (One hundred milimetres) size
75mm (Seventy five milimetres) size
Providing and fixing oxidized 250mm (Two hundred fifty milimetres) size M.S. hooks and eyes complete within all leads, lifts of materials and other. Incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing automatic vitro hydraulically compressed and polished pre-cast terrazzo tiles 30x30cm(Thirty into Thirty centimeters) ISI marked 1237 25mm(Twenty five milimetres) thick with marble chips of specified size laid in floors, treads of steps and landings on a bed of 25mm(Twenty five milimetres) average thickness of cement mortar 1:6 (One cement: Six approved sand) jointed with cement slurry mixed with pigment to match the shade of tiles (Wherever required) including rubbing and polishing complete as per direction of Engineer-in-charge within all leads and lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge..
Providing 20mm to 25mm (Twenty milliemetres to Twenty five milimetres) thick Kota Stone flooring Mirror polished with 7.5 cm (Seven decimal Five centimetres) wide uniform colour marble band with black mandana /Jaislmer yellow in base of 25mm (Twenty five millimetre) thick cement mortar 1:4 (One cement: Four sand) laid over and jointed with Grey cement slurry mixed with pigment to match the shade of the slab including hosing, rubbing and polishing complete including carriage of material within all leads, lifts and other incidentals as per approved specifications, drawing, design and as directed by the Engineer-in-charge.
Providing and fixing heavy duty double charged vetrified tiles Nitco/Kazaria/Asia/Rak 600x600mm (Six hundred into Six hundred millimetres) manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm (Twelve millimetres) thick cement mortar 1:3 (One cement : Three sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete, as directed by the Engineer-Incharge, including entire carriage of materials within all leads, lifts and other incidentals.
Providing and fixing 0.60mm (Zero decimal Six Zero milimetres) thick prepainted steel sheet TATA / Shakti or equinalant in roofing with hot dipped metalic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 (Twenty) microns over 5 (Five) microns primer coating to back coat of polyster of 10 (Ten) microns over 5 (Five) microns primer coating including fixing with prepainted iron J or L hooks,bolts and nuts 6mm (Six milimetres) diametres with prepainted limpet and rubber washers complete with all accessories as required complete including carriage of materials within all leads, lifts and other incidentals and as directed by the Engineer-in-Charge.
Providing and fixing ridges or hips 60cm (Sixty centimeters) over all with 0.60mm (Zero point Sixty millimeters) thick prepainted sheet roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 (Tweny) microns over 5 (Five) microns primer coating to back coat of polyster of 5 (Five) microns over 5 (Five) microns primer coating including fixing with prepainted iron J or L hooks, bolts and nuts 6mm (Six millimeters) diametres with prepainted G.I. limpet and bitumen washers complete with all accesoriees as required complete including carriage of materials within all leads, lifts and other incidentals and as directed by the Engineer-in-Charge.
Providing and fixing valley 90cm (Ninety centimeters) over all with 0.60mm (Zero point Sixty millimeters) thick prepainted sheet roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RMP) organic coating of 5 (Five) microns over 5 (Five) microns primer coating to back coat of polyster of 5 (Five) microns over 5 (Five) microns primer coating including fixing with prepainted iron J or L hooks, bolts and nuts 6mm (Six millimeters) diametres with prepainted G.I. limpet and bitumen washers complete with all accesoriees as required including carriage of materials within all leads, lifts and other incidentals as per specification approved drawing, design and as directed by the Engineer-Incharge.
Providing and fixing flushing 38cm (Thirty eight centimetres) overall with 0.60mm (Zero point six zero millimetres) thick prepainted sheet in roofing with hot dipped metalic zinc coated sheet with top coat of regular modified polyster organic coating of 20 (Twenty) microns over 5 (Five) microns primer coating + back coat of polyster of 5 microns over 5 (Five) microns primer coating including including fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia meter & prepainted G.I. limpet & bitumen washers complete with all accessories as required as per the direction of Engineer-in-Charge within all leads, lifts of materials and other incidentals as per approved architectural drawing, design and specification.
Providing and fixing plain M.S. B.P. sheet 1.66mm to 2mm (One decimal sixty six millimeter to Two milimetres) thick 16 gauge eaves board/facia/soffits/ceiling including cutting, fixing in position complete (frame work is to be measured and paid for separately within all leads, lifts of materials and other. incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge
Providing and fixing 100mm (One hundred milimetres) dia pipe on wall face PVC (D-Plast) rain water pipes of working pressure not less than 4.5 kg/sqm including filling the joints with approved adhesive complete as per direction of Engineer-In-Charge, including carriage of material within all leads, lifts and other incidentals.
Providing and fixing on wall faces P.V.C. (D-Plast) accessories for rain water pipes of Supreme/Sant including filling the joints with approved adhesive complete as directed by the Engineer-Incharge as per specifications, including entire carriage of materials within all leads, lifts and other incidentals.
C.I. Plain bend 100mm (One hundred milimetres) dia
C.I. Plain Shoes 100mm dia (One hundred milimetres)
Providing and fixing PVC holder bat clamps of approved design to PVC rain water pipe embedded in and including cement concrete blocks 10x10x20cm (Ten into Ten into Twenty centimetres) of 1:2:4(One cement: Two sand: Four graded crushed stone aggregate 20mm (Twenty milimetres) nominal size and cost of cutting holes and making good the walls within all leads and lifts and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge
Steel work welded in built up sections joints in tubler section/angles/channels composed of beams, joists channels, angles, tees flat with connecting plates or angles, cleat etc. as in trusses, trussed purlins main and cross beams, hips jack rafters, purlins connected to common rafters and the like in building including cutting, fixing, lifting, hoisting and; placing in position complete and applying a coat of red lead paint or equivalent complete within all leads, lifts of materials and other. Incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge
Providing and fixing colour coated/anodised aluminium work for door frame, window, ventilators and glazed partitions frame with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etcetera. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically where ever required including cleast angle, aluminium, snap beading for glazinge/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and as per the directions of Engineer-In-Charge including carriage of materials within all leads and lifts and other incidentals.
Providing and fixing colour coated/anodised aluminium work for door, window, ventilators and glazed partitions shutter with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etcetera. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically where ever required including cleast angle, aluminium, snap beading for glazinge/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and as per the directions of Engineer-In-Charge including carriage of materials within all leads and lifts and other incidentals. including carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing angle iron cupboard frames manufactured from M.S.angle iron section 25X25X5mm (Twenty five into Twenty five into Five milimetres) thickness including hinges jamb,lock jamb,beed and if required angle thrashold of mild steel angle 25X25mm (Twenty five into Twenty five milimetres) welded or rigidly fixed by mechanical means,lugs with split end tails to each jamb including steel butt hinges 2.5mm (Two decimal Five milimetres) thick with provision for locking arrangement and shock absorber as specified and applying a coat of approved steel primer after preteatment of the surface as directed by Engineer-in-Charge within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and fixing M.S. rectangular pipe stair railing over M.S. flat having baluster 20x20mm (Twenty into Twenty milimetres) and 12x12mm (Twelve into Twelve milimetres) M.S. solid square bars in combination with M.S. flat 40x6mm (Forty into Six milimetres) with a clear height of 85cm (Eighty five centimetres) at the rate of 6 (Six) centre to centre jointing in cement concrete steps and jointing with electic gas welding at top along with hand rail of hollow M.S. rectangular pipe of 75x25mm (Seventy five into Twenty five milimetres) (SWG-16) vertical M.S. solid square bars baluster welded/jointed with each with 2(Two) numbers M.S. flat of 40x6mm (Forty into Six milimetres) complete with a priming coat of red paint as per specifications and direction of the Engineer-Incharge within all leads, lifts of materials and other Incidentals as per approved drawing, design and as directed by the Engineer-in-Charge
Providing and fixing of hollow pipe of 50mm diametre hand rail slip resistant with round ended joint at two level at 75cm and 90cm (Seventy five and nonety centimetres) height welded with 25mm diametre baluster embedded in cement concrete 60cm centre to centre and jointing with electrical gas welding at top alongwith hand rail of hollow M.S. pipe of 50mm diametre SWG-16. The baluster welded/jointed with each with 2 Nos M.S. flat of 50x5mm complete with applying pr9ming coat of red lead p[aint as per specification and as per direction of Engineer-Incharge within all leads, lifts of materials and other Incidentals as per approved drawing, design and as directed by the Engineer-in-Charge
Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint brushing to give an even shade including cleaning the surfaces of all dirt, dust andother foreign matter enamel paint other than white within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Applying priming coat over new wood and wood based surfaces after and including prepering the surface by thoroughly cleaning oil,grease,dirt and other foreign matter) sand papering and knotting with ready mixed paint brushing wood primer pink within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Painting two coats(excluding coat) on new wood and wood based surface with enamel paint other than white to give an even shade including cleaning the surface of dirt,dust and other foreign matter,sand papering and stoping within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
6mm (Six milimetres) thick cement plasters in ceiling with cement mortar 1:3 (One cement: Three sand) for all heights within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
15mm (Fifteen milimetres) thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto all floor levels including arises internal rounded angles, chamfers and or rounded angles not exceeding 80mm (Eighty milimetres) in girth and finished even and smooth with cement mortar 1:6 (One cement: six sand) within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
15mm (Fifteen milimetres) thick cement plaster in single coat on fair side of brick/concrete/stone walls for interior plastering upto all floor levels including arises internal rounded angles, chamfers and or rounded angles not exceeding 80mm (Eighty milimetres) in girth and finished even and smooth with cement mortar 1:6 (One cement: six sand) within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
15mm (Fifteen milimetres) thick cement plaster in single coat on fair side of brick/concrete/stone walls for interior plastering upto all floor levels including arises internal rounded angles, chamfers and or rounded angles not exceeding 80mm (Eighty milimetres) in girth and finished even and smooth with cement mortar 1:5 (One cement: Five sand) within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Applying Birla J.K. white wall care putty over plastered surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters and sand papered smooth to give final matter finish to the surface complete including entire carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
White washing with lime on un-decorated ceiling/slopping roofs (two or more coats) to give an even shade including thoroughly brooming the surfaces to remove all dirt, dust, mortar, dirt and other foreign matter, within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Distempering (two or more coats) with acrylic oil bound washable distemper of Nerolac/ Asian or its equivalent of approved brand and manufacture and of required shade on undecorated wall surfaces to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and sand papered smooth.priming coat with distemper primer including entire carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on un-decorated walls surfaces (Two or more coats) to give an even shade after thoroughly brushing the surfaces to remove all dirt, dust and remains of lose powdered materials, within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Applying priming coat on new concrete/masonry/asbestos cement/plastered surfaces after and including preparing the surface by thoroughly cleaning oil,grease,dirt and other foreign matter and sand papering as required withwithin all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surfaces to give an even shade including thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth including applying of putty as required for making the surface within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing under layer for plinth protection of 75mm (Seventy five milimetres) thick(un-consolidated)bed of dry brick/stone aggregate 40mm (Forty milimetres) nominal sizes well rammed and consolidated and grouted with fine sand including preparation of ground within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing plinth protection 50mm (Fifty milimetres) thick cement concrete 1:3:6 (One cement: Three sand: Six graded crushed stone aggregate 20mm (Twenty milimetres) nominal size) including finishing the top surfaces of concrete smooth within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Construction of cement concrete covered drain in cement concrete 1:3:6 (One cement : Three sand : Six graded crushed stone aggregate 20mm (Twenty milimetres) nominal size) including earth work, shuttering and cast in-situ reinforced cement concrete slab over drain and cement concrete flooring 1:2:4 (One cement : Two sand : Four graded crushed stone aggregate 20mm (Twenty milimetres) nominal size) and finished with floating coat of enat cement completre as per standard drawing within all leads, lifts of materials and other incidentals. as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing and Laying 60mm (Sixty milimetres) Interlocking Concrete Block Pavements having thickness as per drawings and Technical Specification Clause 1504 make of NTC/ GDC/Atlantica make including 4mm thick (Four millimetres) thick levelling course of sand and locking with cement concrete M-30 (M-Thirty) complete and as per IRC SP-63-2004 & IS 15658 including carriage of material within all leads, lifts and other incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-charge.
Neeraj
Shadil Thakur
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .