Tender Value
Refer Docs
EMD Value
₹20,213
Closing Date
28 Jan 2026, 6:00 pmClosed
Area Manager(EnM)
EJ Area Office
Testing of 11 kv, 3.3 kv CTs by Primary injection set for relays effectiveness testing and also issuing test certificate for record at 37/38 Substation and C-2 Patch substation under ABNS Colliery
2026_BCCL_351513_1
BCCL/EJA/EnM/2025-26/159
Open Tender
Electrical and Maintenance Works
Percentage
10 days
EJ Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,213
29 Jan 2026
20 Jan 2026
29 Jan 2026
20 Jan 2026
28 Jan 2026
20 Jan 2026
20 Jan 2026 - 28 Jan 2026
Relay effectiveness testing by Secondey injection set of Earth Lekage with test Certificate of 11 kV, 3.3 kv Indoor Panels
Relay effectiveness testing by primary injection set of CTs/Over current with test Certificate of 11 kV, 3.3 kv Indoor Panels
Relay effectiveness testing by Secondey injection set of Earth Fault with test Certificate of 11 kV, 3.3 kv Indoor Panels
Testing of Earth pit with test certificate
Testing of Insulason test with test certificate of 11 kV, 3.3 kv Indoor Panels
High Prasor(HV) set Braker with test Certificate of 11 kV, 3.3 kv Indoor Panels
Testing of Dielectric Strength Test of Insulating Oil ,Acidity Test of Insulating oil and Flash point of Insulating oil with test Certificate of 11 kV, 3.3 kv Indoor Panels
Testing of Dielectric Strength Test of Insulating Oil ,Acidity Test of Insulating oil and Flash point of Insulating oil with test Certificate of 2.5 MVA, 500 KVA,300 KVA & 250 KVA, 40 KVA Transformer
High Prasor(HV) set Braker and Alarm & Trip device test with test Certificate of 2.5 MVA, 500 KVA,300 KVA & 250 KVA, 40 KVA Transformer
Testing of Insulation Resistance Test and High Prasor(HV) set with test certificate of 90 sq mm PVC Double Armoured Aluminium cable.
Testing of Overhead line Insulason test with test certificate 11 KV 3 PHASE OVERHEAD LINE FROM 33 kv sub station Amlabad to ABNS C-2 Patch sub station aprox 6 Km
Testing of Overhead line High Prasor(HV) set with test certificate11 KV 3 PHASE OVERHEAD LINE FROM 33 kv sub station Amlabad to ABNS C-2 Patch sub station aprox 6 Km
Testing of Overhead line Insulason test with test certificate 3.3 KV 3 PHASE OVERHEAD LINE FROM C-2 Patch sub station to pump-1 & pump-2 aprox 3.5 Km
Testing of Overhead line High Prasor(HV) set with test certificate 3.3 KV 3 PHASE OVERHEAD LINE FROM C-2 Patch sub station to pump-1 & pump-2 aprox 3.5 Km
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.38 MB
BOQ_364270.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .