Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
3 Jun 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT POW.
13 conditions · 2 needing a document upload
As per Rly Board's L. No. 2022ICE-I/CT/GCC-2022/Policy, Dated: 14.07.2022, the tenderer must have minimum average annual contractual turnover of V/N or V whichever is less,where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB annexed as annexure-J in chapter 4 of tender document, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (c )Definition of similar nature of work: Any electrical work related to HT/LT installation.
34 conditions · 16 needing a document upload
Tenderers have to submit the valid Electrical contractor license with supervisor competency certificate. Non submission of this document, offer of bidder shall be summarily rejected.
Document verification certificate as per annexure-V of GCC- 2022 , annexed as annexure-A of Chapter-4 of tender document. Non submission of This certificate(s) by the bidder shall result in summarily rejection of his/their bid. ( Click here to download Format)
Submission of Annexure-B of Chapter-4 of tender document, Annexure-V(A) of ACS No2 dated:13.12.2022) shall also be submitted by the each member of a Partnership Firm/ Join) Venture_(J / Hindu Undivided_Fami1y_(HUFF / L mited Liability Partnership fLLP) etc. as the case may be. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. ( Click here to download Format)
An under taking regarding blacklisted or debarred of firm as per annexure-C of Chapter-4 of tender document. ( Click here to download Format)
Declaration regarding association of Rly Officer(S) or retired Rly. Officers with bidder/tenderer as per annexure-D of chapter-4 of tender document. ( Click here to download Format)
Declaration of no relative being an employee of railway as per annexure -E of Chapter-4 of tender document. ( Click here to download Format)
Bank mandate form as per Annexure -F of Chapter-4 of tender document. ( Click here to download Format)
Contractual payment receipt format (Annexure-VIB of GCC-2022) as per annexure J of Tender Document for average annual contractual turnover ( Click here to download Format)
Relevant Work completion Certificate of similar nature work issued by client indicating received amount, Contract period, Agreement detail, details of scope of work etc. Similar nature of work is defined as:- "Any electrical work related to HT/LT installation."
Tenderer should submit dully filled Annexure-K. ( Click here to download Format)
Submission of Bid Security as per Annexure-G of Chapter-4, if Applicable
Power of attorney ( notarized affidavit on Stamp Paper) to authorize a person to submit the offer if Firm is a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF etc. For proprietorship firm, it is not required, if offer is submitted by proprietor himself.
Active mobile contact No. & E-Mail ID for future communication.
Any other document as per requirement of tender clause.
Submission of GSTN & PAN card.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Submission of option for "Implementation of payment through letter of credit(LC) As option in Domestic supply/works( including all services and maintenance contract), having estimated value of Rs. 10 Lakhs and above".
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
Right of Railway to Deal with Tenders: The Railway reserves the right of not to invite tenders for any of Railway work or works or to invite open or limited tenders and when tenders are called to accept a tender in whole or in part or reject any tender or all tenders without assigning reasons for any such action. In case if tender is accepted in part by Railway administration, Letter of Acceptance shall be issued as counter offer to the Tenderer, which shall be subject to acceptance by the Tenderer.
Certificates from private individuals for whom such works are executed being executed is not acceptable.
Any Conditional offer will be summarily rejected.
2 % IT shall be deducted from bill.
As per section 51(1) Railway shall be required to deduct Tax at source (TDS) @ 2% On the Payment made to supplier where the total value of supply under contract exceeds Rupees 2,50,000/- Excluding GST.
Rates are inclusive of all taxes/octroi, license fee, royalty charges etc. legally leviable by State, Central Govt. and/or any other local authority.
Earnest Money: -All the tenderers / Contractors have to deposit full earnest money as stipulated in the tender document through online modes as permitted in IREPS application.
During the currency of the contract, no partner of the firm shall be permitted to withdraw from partnership business and in such and event it shall be treated as breach of trust and abandonment of the contract.
JOINT VENTURE will not be permitted for the tenders
Any Conditional offer will be summarily rejected.
For Standard Financial criteria and Standard Technical criteria - Tenderers are required to submitted authenticated certificate along with the tenders from officers of government or semi- government/public sector undertakings under whom the work has been executed indicating there in the name of work executed, value of works/payment details and period during which completed. Such certificates should have signature and seal of the concerned officer. In the absence of such certificate the tender may not be considered.
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
In case of any wrong information submitted by tenderer, the contract shall be terminate, Earnest Money Deposit (EMD), Performance Guarantee (PG) and Security Deposit *(SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 5 (five) years.
Improvement in Lighting through Energy efficient lighting fixtures at various locations in RWP, Bela.
EL-Lighting-OT-2025-2026
EL-Lighting-OT-2025-2026
Open
Works - General
6 Months
Saran, Bihar
₹0
₹2.7 L
3 Jun 2026
12 May 2026
20 May 2026
81 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,36,84,782 | ||
| — | 5.00 | — | — | ||
| Supply, fabrication, installation, testing and commissioning of electrical outdoor panel (LVDB) with 4 legs ,canopy type made of 1.6 mm thick IP 42 sheet steel enclosure duly painted with powder coating, 4 Nos. aluminums bus bars having current carrying capacity as required, suitable for 415 V, 3 phase, 4 wire, 50Hz, A.C. supply with fixing of MCB TPN 63A, Breaking capacity 10 kA -1 No. & MCB TPN 32 A,Breaking capacity 10 kA -06 Nos., . contactor 4P 63A - 02 Nos., timer 01 No, Phase indicator including all connection as required. All the above material shall be provided by contactor. MCCB/MCB, Make: Lauritz knudsen, ABB, Schneider, Siemens C&S, Legrand. | — | — | — | 1,75,000 | |
| — | 3.00 | — | — | ||
| Supply, fabrication, installation , testing and commissioning of electrical outdoor electrical panel (LVDB Pannel) canopy type with 4 legs made of 1.6 mm thick IP 42 sheet steel enclosure duly painted with powder coating, 4 Nos. aluminums bus bars having current carrying capacity as required, suitable for 415 V, 3 phase, 4 wire, 50Hz, A.C. supply with fixing of MCCB TPN 100A,Breaking capacity 25 kA -1 No. and MCCB TPN 63 amp,Breaking capacity 25 kA- 01No. with Ampere meter 0-100A, Volt Meter-500 volt with rotary switch, Phase indicator including all connection as required. All the above material shall be provided by contactor.MCCB/MCB make:Lauritz knudsen, ABB, Schneider, Siemens ,C&S, Legrand. | — | — | — | 2,25,000 | |
| — | 1.00 | — | — | ||
| Supply, fabrication, installation , testing and commissioning of electrical indoor panel (LVDB) with 4 legs , made of 1.6 mm thick IP 42 sheet steel enclosure duly painted with powder coating, 4 Nos. aluminums bus bars having current carrying capacity as required, suitable for 415 V, 3 phase, 4 wire, 50Hz, A.C. supply with fixing of MCCB TPN 4 pole 100A,Breaking capacity 25 kA -1 No.& MCB TPN 4 pole 63 A, Breaking capacity 10 KA-04 Nos. , Ampere meter 0-100A, Volt Meter-500 volt , Contactor 63A ,4Pole-01 no. , Timer-01 No. Phase indicator including all connection as required.. All the above material shall be provided by contractor.MCCB/MCB make:Lauritz knudsen,ABB, Schneider, Seimens ,C&S, Legrand. | — | — | — | 45,500 | |
| — | 2.00 | — | — | ||
| Supply, fabrication, installation , testing and commissioning of electrical outdoor panel (LVDB) with 4 legs , made of 1.6 mm thick IP 42 sheet steel enclosure duly painted with powder coating, 4 Nos. aluminums bus bars having current carrying capacity as required, suitable for 415 V, 3 phase, 4 wire, 50Hz, A.C. supply with fixing of MCB TPN 63A, Breaking capacity 10 kA -1 No. & MCB SP 32 A-06 Nos., Ampere meter 0-100A, Volt Meter-500 volt , Contactor 63A ,4Pole-01 no. , Timer-01 no. Phase indicator including all connection as required.. All the above material shall be provided by contactor.MCB Make:Lauritz knudsen,ABB, Schneider, Seimens ,C&S, Legrand. | — | — | — | 51,000 | |
| — | 400.00 | — | — | ||
| Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Wire Make: Polycab,Havells, KEI,Universal, Finolex, Anchor, PVC pipe Make: Ashirwad, Prakash ,Malhotra, Suprem, Astral pipes, AKG.(i) 2x1.5 Sq.mm +1x1.5 sq.mm earth wire. | — | — | — | 93,200 | |
| — | 900.00 | — | — | ||
| (ii)2X 2.5sq. mm +1 X 2.5 sq. mm earth wire , | — | — | — | 2,47,500 | |
| — | 10255.00 | — | — | ||
| Supply of 4C X 10 mm2 PVC insulated and PVC sheathed XLPE Armored Aluminum power cable of 1.1 KV.Make: Polycab, Havells, KEI, and Universal. | — | — | — | 10,97,285 | |
| — | 2149.00 | — | — | ||
| Supply of 4C X 25 mm2 PVC insulated and PVC sheathed XLPE Armored Aluminum power cable of 1.1 KV.Make: Polycab, Havells, KEI, and Universal. | — | — | — | 3,95,416 | |
| — | 600.00 | — | — | ||
| Supply of 4C X 35 mm2 PVC insulated and PVC sheathed XLPE Armored Aluminum power cable of 1.1 KV. Make: Polycab, Havells, KEI, and Universal. | — | — | — | 1,39,200 | |
| — | 350.00 | — | — | ||
| Supply of 4C X 50 mm2 PVC insulated and PVC sheathed XLPE Armored Aluminum power cable of 1.1 KV.Make: Polycab, Havells, KEI, and Universal. | — | — | — | 1,05,350 | |
| — | 112.00 | — | — | ||
| Supply of 4C X 70 mm2 PVC insulated and PVC sheathed XLPE Armored Aluminum power cable of 1.1 KV.Make: Polycab, Havells, KEI, and Universal. | — | — | — | 54,880 | |
| — | 638.00 | — | — | ||
| Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.Make:Havells, JBL, Reychem, 3M. (i)4X 10 sq. mm | — | — | — | 1,65,880 | |
| — | 41.00 | — | — | ||
| (ii)4Cx25 Sq.mm | — | — | — | 10,619 | |
| — | 14.00 | — | — | ||
| (iii)4Cx35 Sq.mm | — | — | — | 4,256 | |
| — | 8.00 | — | — | ||
| (iv) 4Cx50 Sq.mm | — | — | — | 3,240 | |
| — | 2.00 | — | — | ||
| (v)4Cx70 Sq.mm | — | — | — | 796 | |
| — | 7706.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground upto depth of 750mm including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS:1255-1983 or latest. (i) Upto 35 sq.mm | — | — | — | 24,58,214 | |
| — | 183.00 | — | — | ||
| (ii)Above 35 Sq.mm and upto95 Sqmm | — | — | — | 60,939 | |
| — | 2030.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS:1255-1983 or latest.(i) Upto 35sqmm. | — | — | — | 4,64,870 | |
| — | 900.00 | — | — | ||
| Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on wall surface as required.(Clamp with1mm Thick saddle)Upto 35 Sq.mm size (clamped with 1mm thick saddle)(i)Upto 35 sq. mm (clamped with 1mm thick saddle) | — | — | — | 40,500 | |
| — | 100.00 | — | — | ||
| (ii)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS Metre 130 flat clamp) | — | — | — | 13,000 | |
| — | 100.00 | — | — | ||
| Supply and laying of 32 mm dia GI pipe , medium gauge "B' Class under the road for XLPE / LT cables for protections . Road cutting for laying of GI Pipe and road repairing charge shall be paid by Railway. Pipe Make-Tata/Jindal/Bansal. | — | — | — | 33,500 | |
| — | 407.00 | — | — | ||
| Supply and laying of 80 mm dia GI pipe, medium gauge "B' Class under the road for XLPE /LT cables for protections. Road cutting for laying of GI Pipe and road repairing charge shall be paid by Railway. Pipe Make-Tata/Jindal/Bansal. | — | — | — | 3,43,101 | |
| — | 507.00 | — | — | ||
| Road Cutting for laying of LT/HT cable: Demolishing cement concrete manually/ by mechanical means including disposal of material as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix for laying of LT/HT Cables as per standard Depth as per IS:1255-1983. | — | — | — | 61,854 | |
| — | 507.00 | — | — | ||
| Road Repairing after laying of LT/HT Cable upto standard Depth (IS:12551983) - Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level: 1:1.5:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources:3 graded stone aggregate 20 mm nominal size derived from natural sources). | — | — | — | 2,49,444 | |
| — | 80.00 | — | — | ||
| Supply and erection of 8 meter long Octagonal GI pole, single Arm including digging of pit, making RCC foundation size 18" x 18"x 60" with cement , sand and concrete in ratio 1:1.5:3 with MS rod dia not less than 20mm, muffing accommodation GI pipes in foundation for cable loop in- Loop out (Loop Box including 6A MCB) of suitable size as required in all the respect as required. Pole Make: Bajaj, Shreeram, Utkarsh, | — | — | — | 9,83,040 | |
| — | 5.00 | — | — | ||
| Supply and laying of 300 mm dia RCC Pipe NP2 Class | — | — | — | 2,250 | |
| — | 5.00 | — | — | ||
| Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (For Rail Crossing) | — | — | — | 1,940 | |
| — | 80.00 | — | — | ||
| Supply, installation testing and commissioning of 90 Watt LED luminare for road and street light including wiring & complete in all the respect. Spec.:- (i) Luminaire system efficacy greater than/100 Im/watt, (ii) Ingress protection-IP66, (iii) Adjustable mounting bracket, (iv) Automatic higher voltage cut-off-Yes, (v) Input operating Voltage-90 to 300 V, AC(vi) Polycarbonate Lens (vii) Heat Sink should be Die-Cast Aluminum, (viii) Short Circuit, Over Load, Over Voltage Protection-Yes (ix) Luminaire body should be corrosion resistant Epoxy Powder Coated-Yes (x) All fastener must be stainless steel. (xi) Warranty 5 Year. Make:Surya, Crompton, Bajaj, Philips, C&S, Orient Electric, Havells, Panasonic, Halonix,Leksa | — | — | — | 2,88,000 | |
| — | 10.00 | — | — | ||
| LED post top made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative PMMA opal and Clear di user and IP65 protection., Watt-45 watt , CCT- 5700K, As per model No.. BGCTN 45W LED WH (max. outer dia. 60 mm for fitting in lighting pole ) of Bajaj or approved. Make:Surya, Crompton, Philips, C&S, Orient Electric, Havells, Panasonic, Halonix,Leksa | — | — | — | 90,000 | |
| — | 10.00 | — | — | ||
| Supply & erection of 4 mtr.hot dipped GI pole (Lighting pole), top dia. 60 mm, making foundation with cement , sand and concrete in ratio 1:1.5:3,depth of foundation should not be less than 1 mtr. Make: Halonix, shriram, Luminica, AVG, Bajaj. | — | — | — | 13,610 | |
| — | 175.00 | — | — | ||
| Supply Installation, Testing and Commissioning of LED High Bay Lighting for ceiling suspension type, Round shape, metallic adjustable brackets with eye bolt, Pressure die cast Aluminum alloy, epoxy powder coated, heat resistant toughened glass, Polycarbonate-UV stabilized ,SMD LED Chip,wattage-150 Watt, colour temp.(k)-5700/6000, 240 Volt, 50 Hz as per model no. OPTIBAY 150W WH NB PC SD 150 watt of Bajaj or similar Make of Make:Surya, Crompton, Philips, C&S, Orient Electric, Havells, Panasonic, Halonix,Leksa. | — | — | — | 39,37,500 | |
| — | 6.00 | — | — | ||
| Earthing with G.I. Earth pipe 4.5 mts long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt) as required. | — | — | — | 33,846 | |
| — | 10.00 | — | — | ||
| Supply and Fixing of 25x5 mm size GI strips on surface or in recess for connection etc. as required. | — | — | — | 1,640 | |
| — | 120.00 | — | — | ||
| Supply and laying of cable route marker with 10cm X 10cm X5mm with thick GI plate with inscription there on bolted/welded to 35mm X 35mm X 6mm/ 10cm dia round angle iron 60cm long and fixing the same in ground as required | — | — | — | 50,160 | |
| — | 3.00 | — | — | ||
| Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) (i) 6 way (4 + 18), Double door. Make: Havells, Anchor, Bajaj, Philips. | — | — | — | 14,922 | |
| — | 165.00 | — | — | ||
| Supply & fixing Stainless Steel water proof looping cable box of size 250x200x105 mm having 4 mm thick with sloping canopy, hinged top Cover with rubber gasket lining, mechanical locking arrangement, earthing terminal with lug &gland etc.as required of the following sizes as indicated above, Comprising of one no. suitable size of SP MCB (5/6 Amp), one NL on porcelain insulator etc. and housing the same on steel tubular pole/ wall by necessary nut-bolts, washers, screws, MS clamp etc. as required. MCB Make:L&T, ABB, Schneider, Seimens ,C&S, Legrand | — | — | — | 2,01,630 | |
| — | 100.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC/HUME/METAL pipe as required(i)Upto 35 sq. mm | — | — | — | 3,100 | |
| — | 62.00 | — | — | ||
| LED post top made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative PMMA opal and Clear di user and IP65 protection as per model no. BGCTN 25W LED WH 25 watt, CCT 5700 Kelvin of Bajaj or similar Make of Surya, Crompton, Philips, C&S, Orient Electric, Havells, Panasonic, Halonix, Leksa. | — | — | — | 4,34,000 | |
| — | 100.00 | — | — | ||
| Supply , installation testing and commissioning of 80 Watt LED High Bay Lighting for ceiling suspension type including connection and completed in all the rsepect. Tech. Specification:(i) Rated voltage (in Volts): 240 V, AC, (ii) Frequency:-50+/-2Hz. (iii)Operating input voltage range (in Volts):100 to 280 , (iv) LED chip Efficacy (Lumen/watt): 130 (v)Color Temperature (CCT) +/- 500 K (in Kelvin):5500 K , (vi) Colour Rendering Index (CRI) (in % age): 70 (vii) Power Factor (PF): 0.95 at full load , (viii)Total Harmonics Distortion (in %age): 10 (ix) Beam angle of light source (in degree): 120, (x) Ingress protection-IP66, (xi)Short Circuit, Over Load, Over Voltage Protection-Yes (xii)Luminaire body should be corrosion resistant Epoxy Powder Coated-Yes (xiii) Shape of Luminaire: Round , (xiv)Installation height range from floor level (in m):5 to 7 Mtr., (xv)Heat sink along with sufficient heat sink fins to dissipate heateffectively:Yes (xvi)Manufactures Name and brand on the Luminaire body Engraved/ Embossed: Yes, (xvi)Optic Lens,Yes: Polycarbonate-UV stabilised (xvii) Material of Lamp (Luminaire) cover Heat Resistant Toughened Glass, (xviii) Metallic adjustable Brackets (Stainless steel),SS Eye Bolts (as perIS:4190:1984 latest),Set of Bolt, Nut, Washers (SS),Die cast aluminium brackets, Metallic Adjustable Brackets (Stainless Steel)provided along with the fixtures for ceiling mounted high bay light fixtures. Warranty-5 Years.Make: Surya, Crompton, Bajaj, Philips, C&S, Orient Electric, Havells, Panasonic, Halonix,Leksa. | — | — | — | 10,89,600 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Implementationofpayment.pdf Impementation of payment through LC as option
ATTACHMENT
FinalcolouredGCC-2020.pdf
ATTACHMENT
GCC-Apr2022.pdf
ATTACHMENT
TDLight.pdf
ATTACHMENT
Implementationofpayment.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .