Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹70.1 L
EMD Value
₹70,120
Closing Date
29 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
executive Engineer,GSPHCL,Ahmedabad
Supplying, Installing, Testing & Commissioning of 20mtr High Mast & LED Flood Light Fitting at Pared Ground-1 & Pared Ground-2 GIPCA campus, RTO circle, Ahmedabad (First attempt)
354422
09(2026-2027)
Open
Electrical Works
Works
Ahmedabad
10 documents required · 9 mandatory · 1 optional
₹2,400
GUJARAT STATE POLICE HOU.CORPORATION LTD.Ahmedabad
₹70,120
12 Oct 2026
12 Oct 2026
12 Oct 2026
29 Oct 2026
12 Oct 2026
Name of Work: Supplying, Installing, Testing & Commissioning of 20mtr High Mast & LED Flood Light Fitting at Pared Ground-1 & Pared Ground-2 GIPCA
campus, RTO circle, Ahmedabad
Schedule of rate for R & B / 2026-27 (Without GST)
No. Description of Item QTY UNIT Rate in Figure Rate in words
1 Providing and supplying 500W High Performance LED Flood Light – Tango XL type, comprising high-
efficiency LED light source with luminous efficacy up to 145 lumens per watt, with approximate system
lumen output up to 71,000 lumens, complete with integral high-efficiency electronic LED driver. The
luminaire shall be housed in robust pressure die-cast aluminium body ensuring excellent thermal
conductivity and provided with suitable corrosion-resistant outdoor finish for reliable operation in harsh
environmental conditions. The fixture shall be provided with high-performance optical system suitable
for uniform and efficient illumination of large outdoor areas and sports/recreational applications, with
suitable optical distribution/beam angle as required for the application. The driver shall be of high-
efficiency type, suitable for outdoor operation and complete with necessary inbuilt electrical and
thermal protections. The flood light shall operate on 230 V AC, 50 Hz supply, with CCT 5700 K, CRI
≥70, and shall be suitable for continuous outdoor operation. The complete luminaire shall have IP66 RS: Thirty One
ingress protection and IK10 mechanical impact resistance, with suitable heavy-duty cradle-type 96.00 Each 31448.00 Thousand Four Hundred
mounting arrangement for installation on high mast/pole/structure and provision for adjustment of Forty Eight only
aiming angle. The luminaire shall be suitable for outdoor applications such as yard lighting,
recreational/sports lighting, city squares, apron lighting, toll plazas, high mast lighting, industrial areas
and other large-area illumination applications, as directed by the Engineer-in-Charge. The complete
fixture shall be suitable for operation under harsh outdoor environmental conditions and shall be
complete in all respects with LED module, optical system, driver, housing, mounting bracket, internal
wiring, connectors and all necessary accessories. The manufacturer/authorised Channel partner of
the manufacturer has to submit 05 year free replcement Guarantee for complete Fixture)
2 SITC of Outdoor aesthetically designed LED Street Light Luminaire with total consumption of max.
Watts with single piece heavy duty & sufficient size of die cast aluminium housing to accommodate
driver, both SPD and necessary wiring and terminal easily inside the housing. High power LEDs
wattage of 5 Watt (Driving current of LED should be max. 80% of Rated current) shall be mounted on
high quality metal core PCB with extremely precison designed heat sink complete with IP66
protection. LED lense are covered with thoughened glass / premium cluster Lens for better light
distribution. The fixture should be suitable for pole/bracket mounting. The fixture should be complied
with both LM79 and LM 80 certified. LED module should be tested L70 at 50,000 hrs ( All Test
Certificate must be submitted with RA bill). LED fitting provided with high quality potted driver with
Metal housing and protection against high and low Voltage cut Off, Protection against 440V. Driver RS: Four Thousand
should have protection like over current, over voltage, short circuit and operational in the temperature Four Hundred Six only
range of 0 deg to 50 deg and humidity range of 10% to 90% RH. THD of driver should be less than
10% and P.F > 0.95. The Fixture should meet the technical criterias like Operating Voltage range
to 270 V, total lumens of fitting not less than 7500, CCT> 4K/6K as per site requirement & decided by
EIC, CRI > 65, beam angle 120 deg, surge immunity level at least 4 KV integral and 10 KV non
integral. (Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit
yrs free replacement Guarantee for complete Fixture)
3 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption of Max.75
watts with single piece heavy duty & sufficient size of die cast aluminium housing to accommodate
driver, both SPD and necessary wiring and terminal easily inside the housing. High power LEDs of
Watt (Driving current of LED should be max. 80% of Rated current ) shall be mounted on high quality
metal core based PCB with extremely precised designed heat sink, complete with IP66 protection.
LED lense are covered with toughened glass / premium cluster Lens for better light distribution. The
fixture should be suitable for pole/bracket mounting. The fixture should be complied both LM79 and
LM 80 certified. LED module should be tested L70 at 50,000 hrs ( All Test Certificate must be
submitted with RA bill). LED fitting provided with high quality potted driver with Metal housing and RS: Five Thousand
protection against high and low Voltage cut Off, Protection against 440V. Driver should have 3.00 Each 5324.00 Three Hundred Twenty
protection like over current, over voltage, short circuit and operational in the temperature range of 0 Four only
deg to 50 deg and humidity range of 10% to 90% RH. THD of driver should be less than 10% and P.F
> 0.95. The Fixture should meet the technical criterias like Operating Voltage range 180 to 270 V,
total lumens of fitting not less then 11250, CCT > 4K/6K as per site requirement & decided by EIC,
CRI > 65, beam angle 120 deg, surge immunity level at least 4 KV integral and 10 KV non integral.
(Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit 5 yrs free
replacement Guarantee for complete Fixture)
4 Supplying, erecting, testing, commissioning approved make M.S. Polygonal High Mast Pole having
following general Specification.
(a) Polygonal Section fabricated from M.S. Plate confirms BSEN 10025 & Hot deep galvanized
minimum 80/86 micron (as per IS 2629 /1985) Lantern carriage with ring and rubber lines for erection
of luminaries of suitable site.
(b) Maximum telescopic section not more than four
(c) Double drum gear pipe motorized winch with 6mm dia S.S. Rod (For 16 mtr and above size)
(d) Approved make L.E.D. aviation light = 1 No. Lightening arrestor = 1 No. with necessary wiring of
as per load 4 core ISI copper cable Unarmoured.
(e) Bottom most section suitable for mounting reversible motor and switchgears having door not more
than 1400mm x 300mm with waterproof gasket & hinges & locking arrangement. RS: Two lac Thirty Eight
(f) Pole structure comprises suitable size of reversible motor, cable and necessary switchgears with 6.00 Each 238052.00 Thousand Fifty Two
control panel. (g) bottom section only
shall have suitable size of thickness supports ribs foundation bolts nuts etc.
(h) Item not comprises the cost of lanterns.
(i) Cost of foundtion includes necessary Cement Concrete/ RCC foundation as per IS and as per OEM
design. Cost also includes testing & commissioning of the entire structure for following size of High
Mast poles, Proof checking & approval (Proof checking of foundation must have to be obtain by
agency from local govt. Eng. collage). It is mandatory before execution. Agency have to start
foundation work after drawing approval from GSPHCL. (Make: Bajaj, RR Ispat, Valmont, Transrail or
approved by EIC)
For High Mast 20 Mtr. TOP A/F 150 Mm, BOTTOM A/F min. 450 Mm, No. of Sec. No. - 2, Bottom
Thickness - 4 mm, Wind speed 40km/hr, Top Sec. - 3 mm, Size Base Plate - dia.580 mm x 20 mm
thick, Foundation Bolt Size M13 x 1000mm. (Specificaion is subject to IS code and according to OEM
design).Refrence drawing attached in specification. GSPHCL will be final authority for approval of
drawing. Suitable for mounting fitting of light 16 Nos. (Note: The agency shall design the cradle in Ring
type design such a manner that, out of the total 360° circumference, lighting fittings are installed in an -
up-and-down arrangement over 180°. The remaining 180° portion shall be utilized as a counterweight
for proper balance and stability. The agency must obtain approval for the fitting mounting cradle
design prior to commencing the manufacturing work.)
5 Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked copper
wires of following size to be erected as directed. 3 core 1.5 sq.mm. PVC insulated round copper wire
ISI mark. RS: Fifty Eight
6a Providing & laying HDPE Double walled corrugated pipes (DWC) (conforming to IS: 16205 (part 24)
2018)) with minimum load required of 450N capacity with anti rodent and ultra violet material
properties with necessary connecting accessories of same material at required depth to be laid 90 RS: One Hundred
cms. under ground for laying of cable below ground / road surface for enclosing cable and back filling 1350.00 Mtr 117.00
the same to make ground as per original. For Outer dia. 50 mm and Inner dia. 38 mm. ) (Test
Certificate to be Submitted)
6b For Outer dia. 90 mm and Inner dia. 75 mm. ) (Test Certificate to be Submitted)
RS: One Hundred
6c For Outer dia. 120 mm and Inner dia. 100 mm. ) (Test Certificate to be Submitted)
RS: One Hundred
7 Providing & erecting Miniature circuit breaker single pole 6 Amp. to 25 Amp. suitable to operate on
240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS RS: One Hundred
8828/1996 with ISI Mark. 36.00 Each 122.00
Twenty Two only
8 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in existing box having following capacity for 63Amp FP RS: Eight Hundred
9 Providing and erecting 415 Volt MCB four pole motor & inductive load(c Curve) having 10 KA
Breaking capacity and confirms to IS : 8828 in existing metal box having following capacity. For 6 to RS: Six Hundred Forty
32 Amp FP. 2.00 Each 649.00
10 Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having
KA breaking capacity & confirms to IS : 8828 in existing metal box having following capacity for RS: Three Hundred
40Amp DP. 3.00 Each 360.00
11 Supplying & erecting approved make Four Pole 415 V change over switch interior for panel mounting
with operating mechanism A.C.23 duty confirming to IS For 250 TO 320Amp FP. Cat III RS: Thirteen Thousand
1.00 Each 13221.00 Two Hundred Twenty One
12 Providing and Erecting approved make Four pole moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having normal current rating 200A. with variable or Fixed thermal &
magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections,spreader tinned RS: Seventeen
copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICu only. 2.00 Each 17667.00 Thousand Six Hundred
Sixty Seven only
13 Supplying and Erecting Approved make Four pole moulded case circuit breaker having breaking
capacity ICU of 35 K.A. at 415 V. having normal current rating 250 A. with Variable or fixed thermal &
magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections spreader tinned RS: Twenty Two
copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only 2.00 Each 22813.00 Thousand Eight Hundred
14 Providing and Erecting approved make Four pole moulded case circuit breaker having breaking
capacity ICU of 25 KA. at 415 V. having normal current rating 25 A to 100A. with variable or Fixed
thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal RS: Six Thousand
connections,spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of 2.00 Each 6723.00 Seven Hundred Twenty
ICu only. Three only
15 Providing and erecting FRLS XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary clamps 1.00 mm thick to be laid 90 cms underground
with 1.00 mm thick G.I heavy duty grade or in existing trench / pipe at road crossing or floor of RS: Four Hundred
following size of cables. for 4 core 4 Sq. mm Fifty One only
16 Providing & erecting FRLS XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable
for 1100 volt to be laid 90 cms. Under ground or to be laid on wall with suitable G.I. heavy guage
1.0mm thick cable clamp or in existing DWC pipe underground or road crossing or floor. For 4 core RS: One Hundred
16 Sq. mm Eighty Two only
17a Providing & erecting approved make FRLS XLPE [IS : 7098 (1)-88] ISI make armoured cable
Aluminium conductor for 1100 V. to be laid 90 cms. Under ground or to be laid on wall with 1.0mm
thick G.I. heavy gauge cable clamp or in existing DWC pipe underground or road crossing or floor.
And making the ground as per the original of following size of cable (Tagging to be provided with RS: Three Hundred
aluminium strips on both the ends & every 10.00 Mtr as approved) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 60.00 Mtr 338.00
Thirty Eight only
17b For 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) (main panel to Parade Ground MSP) (Double run)
RS: Four Hundred
17c For 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core) (SS to Main Panel) (Double run)
RS: One Thousand
Seventy Five only
17d For 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core) (main panel to STP panel) (Double run)
RS: Two Hundred
18a Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P
V C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size RS: Forty Three
cables. For 2 to 4 core x 4.0 Sq. mm (Sigma, MCI, Comet, HMI Make Only) 12.00 Each 43.00
18b For 2 to 4 core 16 Sq. mm (Sigma, MCI, Comet, HMI Make Only) RS: Fifty Seven
19a Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P
V C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size 4.00 Each 66.00 RS: Sixty Six only
cables.(Sigma, MCI, Comet, HMI Make Only) For 3 & 1/2 / 4 core 25 Sq. mm
19b For 3 & 1/2 / 4 core 35/50 Sq. mm
RS: Seventy Five
19c For 3 & 1/2 core 70 Sq. mm
RS: One Hundred
19d For 3 & 1/2 core 185 Sq. mm
RS: Two Hundred
Thirty Six only
20 Providing & fixing PVC cable gland with rubber ring for P V C insulated unarmoured cable complete
with outgoing tails, insulating tape etc. For following size cables. For 2 to 4 core x 6.0 to 10Sq. mm RS: Twenty Five
21 Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut
50.00 Each 8.00 RS: Eight only
bolts in an approved manner. For 1.5/2.5 to 6 Sq.mm Cable
22a Providing & fixing Solderless crimping type Aluminium lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. For 16/25 Sq.mm. Aluminium Cable 70.00 Each 15.00 RS: Fifteen only
22b For 35/50 Sq.mm.
16.00 Each 20.00 RS: Twenty only
22c For 70 Sq.mm.
RS: Twenty Five
22d For 95 Sq.mm.
4.00 Each 40.00 RS: Forty only
22e For 185 Sq.mm.
12.00 Each 80.00 RS: Eighty only
23 Providing, erecting, testing and commissioning insu intelligent Highmast light controller specially
designed for energy saving in conventional street light system (Cat. No. SLC 03 3 ph 15KW HMO)
having technical specification, 3 phase 4 wire, 230 V AC/ph, +/ 25percent R Y B N 4 wire supply
system, 50 Hz (+/ 10percent) 3 W (Stand BY) to 5 W (on full Load) consumption, Advance 8 bit
micro controller, switching on longitude and latitude base, accuracy of +/ 1 minute per month, with
inbuilt battery, with battery life of more than 8 years, with special device which hold the parameter for
more than 10 year without any power and password protected. 16 characters and two line LCD display
with backlight, 4 keys user friendly keyboard system, 25000 VA feeder pillar capacity, 63/100 Amps
isolator, 3 output MCB each of 40/63 Amp., input isolator ELCB 63 Amp. 100 mA., 4 Pole with FR
cable.Provision to by pass by way of relay operation through auto/manual switch, 2 to 55 centigrade RS: Thirty Nine
and humidity 90 percent non condensing, Out door type installation on pole with clamps (Provided with 6.00 Each 39070.00 Thousand Seventy
clamps and nut bolt) or wall or floor, Three locking system flush type internal panel lock, external pad only
lock and internal U clamp locking systems for against theft of Panel, having 30 Kg weight, 16/18
Gauge MS weather proof box with industrial exterior powder coated with 7 tank process RAL
Electrical wiring and control panel for high mast systems motor with up and down facility with upper
and lower limit input. (High and low limit switch and motorized systems is to be provided with high
mast and cable terminated to terminal strip.)
24 Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx.
2mm thick box complete with Bakelite connector strip 5way(3P+N+E), DIN rail for mounting mob &
hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts &
RS: Eight Hundred
washers suitable for erection on pole with cable clamps& earth bolt of following size of box. For 5.00 Each 890.00
25 Providing & erecting bracket consisting of ISI mark "B" class G.I. Pipe 4.2 cm outside diameter
complete with suitable G.I. Sleeve tubing of 2 mm. thick and required size and length suitable for
/ 80 mm. required size of pole top or pipe in pipe surface for terrace as per instruction of EIC or wall
bracket as per instruction of EIC having nuts and bolts for fixing the brackets and having spread of
Upto 0.50 mtr. length with suitable rise as per site condition and suitable welded stiffner reducer and
RS: Four Hundred
nipple with check nut complete painted with one coat of yellow zinc and two coats of alluminium paint 5.00 Each 487.00
Eighty Seven only
for Single arm bracket suitable for pole or terrace as per design given by EIC. For single arm bracket.
(Jindal / Asian / Tata / Surya Prakash make Only) (Fabricators:- Bajaj, Valmont, Transrail, Ambica, RR
Ispat Only) (Test certificate to be submitted)
26 Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx.
2mm thick box complete with bakelite connector strip 4way & hinged doors having locking
arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable RS: Eight Hundred
clamps& earth bolt of following size of box.(a) 300mm x 200mm x 100mm [deep] Ninty only
27 Designing (as per IEC 61439) , Providing & erecting weather proof, dust & vermin proof, floor / wall
mounted front operated indoor type cubical panel board approved panel manufacturer by GSPHC
having necessary IP-54 protection ,made from 14 SWG thick CRCA sheet for outer body & doors &
16 SWG thick CRCA sheet for internal partitions with necessary supporting angles, flats including
skirting, bending, drilling, welding, riveting with internal partitions & cable alley as per site
requirements & instruction of engineer-In-Charge with erection of supplied materials like switchgears,
metering , busbars with suitable size of interconnecting PVC copper wire / Copper-Aluminium strips
(Seperate payment shall be done only for supplied material and erection and testing charges included
in panel item). Panel manufacturer shall supply and erect Rubber gromets, rib, control wires, backelite RS: Twenty One
control fuses/MCB for measuring instruments, Aluminium earth busbar & GI earth bolts, foundation 3.00 sq.Mtr 21500.00 Thousand Five Hundred
flange-bolts-base plates, as per details technical specification nos. of hinged doors, handle with only
locking arrangement, rubber gasket,heavy duty end terminal connection with Cadmium plated nut and
bolt for Anti rusting, necessary ventilation. The panel shall be supplied with Seven Tank chemical
process which shall be carried out before applying painting, painted with epoxy powder coating. ( The
dimension shall be measured excluding base beams) switchgear must be as per GSPHCL approved
brand and model and also panel manufacturers approved by GSPHCL and Busbar cumpartment must
be separate for easy termination of tails/cables and to avoid least distance of punching holes in
busbar. With 350 mm depth
Panel manufacturer have to give 5 years maintenance and service support if in case of breakdown or
fault. Panel manufacturer have to submit electrical meter calibration report. Agency should design the
panel in such a way that there should not be any excess in panel area (sq.mtr) & length of bus-bar
(mtr), if any excess occurs draw attention to GSPHCL at the time of approval of G.A. drawing.
Loading and unloading of above item shall be done by hydra and skill work force under supervision of
electrical engineer and guidelines given by manufacturer to avoid damage to the item. Picture of it to
be submitted in running bill / final bill. Electrical agency must have to check the Size of elect. room /
pump room door and space available in Ele. room / Pump room and if it found not sufficient for easy
installation of Pump, Panel , Stabilizer and other elect. equipments , agency has to coordinate with
DEE (Ele.) for revising size of elect. room/ Pump room. GA drawing shall be approved by GSPHCL
before giving order. [Including Necessary numbering / marking on PANEL with red colour radium
sticker as per site requirement and instructions given by EIC on site. Font / number size given by EIC
on site as per requirement] [Panel Manufacturer factory must be in Gujarat state so three stage
inspection can be done]
28 Providing and erecting following additional parts for panel mounting MCCBs for Extended operating
rotary handle with pad lock with three position trip,off,on suitable for 25A to 250 A panel mounting. RS: Nine Hundred
Company must be same as Switchgear company. 5.00 Each 952.00
29 Providing and erecting multifunctional meter suitable for application of Power monitoring and showing
measurement of following Voltage, Frequency, Apparent energy, Apparent power, Active and reactive
energy, Active and reactive power, Average voltage Vavg, Peak demand power PM, QM, SM,
Demand power P, Q, S, Apparent power S, S1, S2, S3, Unbalance current, Power factor and
displacement PF (signed, four quadrant), Calculated neutral current, Active, reactive, apparent energy
RS: Thirteen Thousand
(signed, four quadrant), Active power P, P1, P2, P3, Voltage U21, U32, U13, V1, V2, V3, Phase
1.00 Each 13984.00 Nine Hundred Eighty Four
currents, Average current Iag, Peak demand currents, Reactive power Q, Q1, Q2, Q3, Demand
current I1, I2, I3, [Us] rated supply voltage 40...300 V AC 45...65 Hz, 40...300 V DC, Network
frequency 50 Hz, Type of network 3P, Display type 7 segments LED, Display colour Red, Messages
display capacity 3 fields of 4 characters, Display digits 12 digit(s) - 14.2 mm in height
30 Providing, erecting, testing and commissioning of L.T. Current Transformer with bus bar primary 50/5
to 1000/5 ratio 15 VA burden having 0.5 Class Accuracy Duly secured with insulating materials RS: Two Hundred
connected to the meter. 4.00 Each 272.00
Seventy Two only
31 Approved make Earth fault Relay suitable to mount with inter connection to moulded case circuit
breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal RS: Five Thousand
connections & complete erected in existing M.S.housing. For 250A- 400A, CT Ration 1/400 2.00 Each 5898.00 Eight Hundred Ninty Eight
32 Supplying and erecting approved make set of indicator lamps LED lamp, lense cover, bakelite holder
RS: Forty Three
complete erected with necessary connections. 3.00 Each 43.00
33a Supplying and erecting tripple pole & neutral 440V / 500 V Panel mounting Copper Busbars with four
equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current /
cross section area) duly wraped with colour insulating tape for phase sequence of following current
carrying capacity, erected with necessary bus bar supports / insulators, main cable socket to each bar, RS: Three Thousand
erected in existing cubical panel with necessary connections.For electrolyte copper busbars Suitable 1.50 Rmt 3171.00 One Hundred Seventy One
for 200 Amp. capacity. only
33b Suitable for 400 Amp. capacity. RS: Seven Thousand
1.50 Rmt 7247.00 Two Hundred Forty Seven
34a Providing & Erecting 2.0 mtr long Earthing system by making minimum bore of 225 mm dia in soft
soil. Suitable for doing pipe-in-pipe technology earthing.Earthing electric rod must be made from
Corrosion free Hot dip galvanizing pipes having following specification.
(A) Earthing Electrode: outerpipe:- 88 mm minimum O.D., ISI 'B ' Class ISI mark of Reputed Brand,
Inner pipe:- 42 mm minimum O.D., Pipe B Class ISI mark reputed Brand Terminal Size: 70mm X
100mm length, Terminal Should be made from inner pipe for that pipe must be pressed and gave
rectangular shape so its work as a terminal.The hot deep galvanising must be done after above
process.Galvanised thickness must be minimum 75 micron any where. SS Nut bolt:- 2 no.with washer
suitable for 14mm dia. hole must be provided at terminal. total minimum Weight(approx.) of earth
electrodewith inside conductive material minimum should be 26 kg. (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm/meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2% (C) Back fill Compound:- Earthing compound should be
RS: Six Thousand
capable to retain moisture for long time Back Filling Compound weight is 25 Kg. 8.00 Each 6000.00
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item specification only] [OEM has to submit all
detail & sample for approved before supplying]
[Water must be poured in bore before starting earthing. Earthing value must be measured with earth
tester. Agency has to bring the earth resistance to at least 02 ohms & voltage between neutral &
Earthing upto 02 volt. Agency has to maintain earthing & its value for one year. Earthing must be done
in the presence of A.E. (GSPHCL)]
34b Providing & Erecting Earthing Chamber and cover:- Earthing chamber should be size of 400 mm X
400 mm X 400 mm depth and Cover should be heavy duty cast iron with required size of 300 mm X
RS: One Thousand
300 mm X 4 mm thick. Necessary test report must be submitted. 8.00 Each 1025.00
Twenty Five only
34c For above earthing additional charges for boring in hard rock soil (by breaker) & filling soft soil in
earth pit (certificate for soil have to given by DEE / AE along with photographs) RS: Three Hundred
Twenty Five only
35a Providing & Erecting Mains with ISI marked, 1.1 KV grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms to IS:694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) RS: Seventy
with required size of copper lugs, nuts and bolts if required. For One wire 6.00 sq. mm only
35b For One wire 10.00 sq.mm
RS: One Hundred
35c For One wire 16.00 sq.mm
RS: One Hundred
Seventy Six only
35d For One wire 25.00 sq.mm
RS: Two Hundred
Ninty Three only
35e For One wire 70.00 sq.mm
RS: Eight Hundred
Twenty Nine only
36 Providing, erecting, fabricating the M.S. structure as per requirement of site as per structure design
Including proper size approved by EIC of M.S. angles, flats, bars, square pipe, channels, sections
(Tata,Zindal,Asian,Jsi Make) complete with cutting, welding, grinding and finishing duly painted with
Asian/Nerolac make premium quality oil paint and true care red oxide metal primer,asian paint make
with erection on site as per direction of engineer in charge with necessary grouting cementing, RS: Seventy Seven
plastering and finishing complete. All hole opening of square pipe end must be closed with M.S plate only
welding. Payment will be done on KG as per Actual weight.
37 Fabracating the perforated G.I. Angle type items made from G.I. Sheet with necessary G.I. Clamp with
anchor fastner, handles other hardware materials as per requirement design with finishing by three
tank powder coating processed inside & outside and painted, erected as directed including minor civil RS: One Hundred
work as per site requirement for installation of energymeter as per Electricity company. Seventy Nine only
38 SITC of Galvanized Steel Flat 25x6 mm thickness from earth electrode with sleeve directly in ground
as required. Zinc coating: 500 g/m square (Approx:70 micron coating) tested and used exclusively for
lightning protection earthing system and ring equipotential bonding. [make and model approved by RS: One Hundred
EIC strictly as per tender specification] Fifty Three only
39 Providing and fixing pre-cast Rubber Dye/ steel Dye inter locking concrete block 60 mm thick with
grade of concrete M300 pnumatic compressed/ vibrated mechanically and as per approved design RS: Six Hundred
confirming IS 15658 : 2006 including 35 mm Sand layer for levelling and filling the joint with sand in 100.00 sq.mtr 680.10 Eighty and Paise Ten
proper line and level as per guidlines of IRC : SP 63-2018 etc. complete only
40 Provinding and fixing WELD MESH JALLI of 0.25mm and 0.25mm wide with necessary screws and
nail at joints cracks of brick work R.C.C work as per drawing and specification and direction of RS: Two Hundred
Engineer incharge. 132.00 Sq.mtr 212.75 Twelve and Paise Seventy
41 Supplying & erecting IP 55 grade following size section pillar fabricated from joint less M.S. Sheet with
angle iron legs made from jointless M.S. Angle with cable clamps to be buried in ground to have
appropriate erection to work uniform until erected with cement concrete foundation and 45 cm high
bricks work finishing with plaster etc. hinged double door internally supported on both side, with
internal and outside looking arrangement with lock and keys in duplicate 35 x 35 x 5 mm M.S. Angle of
RS: One Thousand
Two Nos. one is welded and other with nut and bolt for erecting Bakelite sheet. Painting the Section
2.00 Each 1866.00 Eight Hundred Sixty Six
Pillar inside and out side with three tank powder coated paint. section pillar roof should be without
joint with water leakage proof & tested as per IP 55 test & followed by IS 2147 of 1962 For 60 X 30 X
45 cm section pillar fabricated from 16 Gauge MS Sheet with angle iron legs 45 cm long made from
35 X 35 X 5 mm thick MS angle.
42 Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding power
supply by making up to following size of holes at both ends complete. Up to 150 mm bore dia RS: Six Hundred Ten
43a Providing and erecting Medium Class FIA approved and ISI mark white colour (embossed) RIGID
PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with
adhesive solution & clamps on / in wall / ceiling along with continuous fish wire to draw mains with RS: Twenty Four
necessary fittings and junction boxes for following dia. for 20 mm. dia. only
43b for 25mm dia. RS: Thirty Three
44 Providing & fixing 20 mm. dia Pvc insulated G.I corrugated flexible pipe with necessary socket, PVC
bushes Saddle. RS: Thirty One
Total Amount Rs.
Total Amount Rs.
Assistant Engineer (Ele.) Dy. Ex. Engineer (Ele.) Executive Engineer (Ele.)
Ahmedabad Vadodara Gandhinagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Pared Ground-1 and 2 VOLUME 1.pdf
2. DMO_2941_01-Apr-2026_744.pdf
3. Common Conditions.pdf
4. THIRD PARTY QUALITY CONTROL.pdf
5. Make of Material.pdf
6. Pared Ground-1 and 2 VOLUME 2.pdf
7. Pared Ground-1 and 2 VOLUME 3.pdf
8. ELE SCH-B.pdf
9. Pared Ground-1 and 2 VOLUME 4.pdf
10. ELE01 Tender Document.pdf
11. ELE03 specifications Booklet.pdf
12. Reference Drawing for Pole.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .