Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹3.4 L
Closing Date
4 Apr 2026, 2:00 pmClosed
State Project Director
ARIAS Society, Agriculture Complex, Khanapara, G.S. Road, Guwahati - 781022 (Assam, India)
Conservation, Restoration and Rejuvenation works of the Halowadal Beel of Kokrajhar District under Assam SWIFT Project
2026_FEAP_51912_1
ARIAS /ADB-SWIFT/CW10-70
Open Tender
Civil Works
365 days
Kokrajhar
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,410
₹3.4 L
Yes
ARIAS Society, Agriculture Complex, Khanapara
14 May 2026
13 Mar 2026
4 Apr 2026
13 Mar 2026
4 Apr 2026
30 Mar 2026
13 Mar 2026 - 22 Mar 2026
20 Mar 2026
Weeds clearance : Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/Tanks/Ponds/swampy and marshy areas dragging manually/ mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/sickles/sews as necessary and depositing and stocking in the marginal areas of the beels/tanks/ponds/swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). i) Thin and floating water hyacinths and other aquatic weeds etc.
Weeds clearance : Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/Tanks/Ponds/swampy and marshy areas dragging manually/ mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/sickles/sews as necessary and depositing and stocking in the marginal areas of the beels/tanks/ponds/swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). iv) Medium and floating Taranies,Dalanies, Pitanies and other marginal aquatic weeds etc. upto a depth of 50 cm to 80 cm
Weeds clearance : Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/Tanks/Ponds/swampy and marshy areas dragging manually/ mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/sickles/sews as necessary and depositing and stocking in the marginal areas of the beels/tanks/ponds/swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). v) Heavy and floating Taranies,Dalanies, Pitanies and other marginal aquatic weeds etc. upto a depth of 80 cm to 120 cm
DE-SILTING & EXCAVATION: Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead from the beds of Beels/Tanks/ Ponds/ Swampy lands to the proper grade and slopes as required and utilizing the soil in construction of embankment or repairing of existing embankment on all sides, lifting in uniform layers not exceeding 20 cm thick (excluding compaction), clearing light jungles and trees up to 50 cm girth from the site of work, dug belling, profiling, ploughing or roughening or benching the seat, breaking clods up to 25 mm cube ramming, removing roots and vegetation, dressing to the designed section complete as directed. All kind of soil. The de-silted soil is utilised for construction peripheral bund, rearing tank bund and Approach Road
TURFING: Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shownon the drawingor as directed by the Engineer including preparation of ground, fetching of sods and watering as per Technical Specification Clause 309.
Hume pipe laying at Bund : Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..........NP3 HP...1000 mm dia
EARTHWORK IN EXCAVATION: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material... (I) Ordinary soil.Upto 15.0m Depth For HP Culvert
PLAIN/ REINFORCEMENT CONCRETE: Plain Cement Concrete M15 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
BEDDING FOR PIPE: Bedding for Pipe : Type B (First Class) Bedding..Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii)Granular material For HP Culvert
BRICK MASONRY WORK: Head Wall: Foundation :-Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600,1202&1203 i. Brick masonry in 1:3 cement mortar For HP Culvert
BRICK MASONRY WORK: Head Wall: Substructure :-Brick masonry work in cement mortar in Substructure complete excluding pointing and plastering as per drawing and technical specifications Clauses 600,1202&1203 i. Brick masonry in 1:3 cement mortar For HP Culvert
PLASTERING WORK: Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification For HP Culvert
EARTH CAUSHIONING WORK: Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land (for Earth Work in cushioning) For HP Culvert
PROTECTION WORK: Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 For HP Culvert
PROTECTION WORK: Providing and laying filter material underneath pitching in slopes For HP Culvert
HP CULVERT: Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 1 x 1000 mm dia
HP CULVERT: Providing and Laying Reinforced Cement Concrete Pipe NP3 as per Design in Double Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106.. 2 x 1000 mm dia
SITE CLEARANCE IN APPROACH ROAD : Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By Manual Means-, In area of non thorny jungle
CONSTRUCTION OF EMBANKMENT WITH MATERIAL OBTAINED FROM BORROW PITS: Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (ii)Govt. Land FOR APPROACH ROAD
CONSTRUCTION OF SUBGRADE AND EARTHEN SHOULDERS: Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (ii)Govt. Land FOR APPROACH ROAD
GSB WORK: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.By Mix in Place Method (ii)For Grading II Material FOR APPROACH ROAD
WBM WORK: Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means.. Using stone screening Type-B 11.2 mm for Gr.III FOR APPROACH ROAD
INTER LOCKING CONCRETE BLOCK PAVEMENT: Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. Including Edge block/ Edge restraints FOR APPROACH ROAD
SITE DEVELOPMENT FOR PARKING AREA: Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. For Community Hall & Fish Landing
SITE DEVELOPMENT FOR PARKING AREA (GSB): Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 For Community Hall & Fish Landing
SITE DEVELOPMENT FOR PARKING AREA (WBM: GR - III): Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . For Community Hall & Fish Landing
SITE DEVELOPMENT FOR PARKING AREA (ICBP): Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. For Community Hall & Fish Landing
EARTHWORK IN EXCAVATION: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. For Community Hall, Fish Landing, Water Tank & Fencing Gate
EARTHWORK IN EXCAVATION: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil. Stagging Post in Community Hall
ANTI-TERMITE TREATMENT :- Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration For Community Hall
ANTI-TERMITE TREATMENT :- Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration, For Fish Landing
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% litre. For Community Hall, Fish Landing,
EARTHWORK IN PLINTH FILLING : Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. For Community Hall, Fish Landing,
Brick Soling Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.. Stagging Footing. For Community Hall
PLAIN CEMENT CONCRETE (CAST -IN- SITU): Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) For Community Hall
PLAIN CEMENT CONCRETE (CAST -IN- SITU): Plain cement concrete Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) For Fish Landing & Gate
PLAIN CEMENT CONCRETE (CAST -IN- SITU): Plain cement concrete Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) For septic Tank
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. For Community Hall, Fish Landing,
SHUTTERING: Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns...Footing. For Community Hall, Fish Landing, Water Tank & Fencing Gate
SHUTTERING: Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers . For Community Hall, Fish Landing, Water Tank & Fencing Gate
SHUTTERING: Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, piers, abutments, pillars, posts and struts. For Community Hall, Fish Landing, Water Tank & Fencing Gate
STEEL REINFORCEMENT: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.. For Community Hall, Fish Landing, Water Tank & Fencing Gate
STEEL REINFORCEMENT: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level.. Mild steel and Medium Tensile steel bars . For Septic Tank
REINFORCED CEMENT CONCRETE (CAST -IN- SITU): Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources). For Community Hall, Fish Landing, Water Tank & Fencing Gate
䕒义但䍒䑅䌠䵅久⁔佃䍎䕒䕔⠠䅃呓ⴠ义䥓啔㨩††††††††††††††††††††††††††††††††敒湩潦捲摥挠浥湥⁴潣据敲整眠牯湩眠污獬⠠湡⁹桴捩湫獥⥳湩汣摵湩瑡慴档摥瀠汩獡整獲畢瑴敲獳獥汰湩桴愠摮猠牴湩潣牵敳ⱳ映汩敬獴潣畬湭ⱳ瀠汩慬獲楰牥ⱳ愠畢浴湥獴潰瑳湡瑳畲獴攠捴扡癯汰湩桴氠癥汥甠⁰潴映潬牯映癩敬敶ⱬ攠捸畬楤杮挠獯⁴景挠湥整楲杮桳瑵整楲杮楦楮桳湩湡敲湩潦捲浥湥⁴›ㄠㄺ㔮㌺⠠‱散敭瑮㨠ㄠ㔮挠慯獲慳摮稨湯ⵥ䥉⥉搠牥癩摥映潲慮畴慲潳牵散›″牧摡摥猠潴敮愠杧敲慧整㈠‰浭渠浯湩污猠穩敤楲敶牦浯渠瑡牵污猠畯捲獥⸩†潆楆桳䰠湡楤杮慗整慔歮☠䘠湥楣杮䜠瑡eᴀ⸀ᰀ㤀ᴂ挀ࠂ䕒义但䍒䑅䌠䵅久⁔佃䍎䕒䕔⠠䅃呓ⴠ义䥓啔㨩†††††††††††††††††††††††††††††††删楥普牯散散敭瑮挠湯牣瑥潷歲椠敢浡ⱳ猠獵数摮摥映潬牯ⱳ爠潯獦栠癡湩汳灯灵琠㔱₰慬摮湩獧慢捬湯敩ⱳ猠敨癬獥档橡慪ⱳ氠湩整獬戬湡獤汰楡楷摮睯猠汩獬瑳楡捲獡獥愠摮
aid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) For Community Hall,ô³DOOR : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Main Door & Back Door For Community Hall, UPVC Window :- Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). For Fish Landing,ú PVC DOOR FRAME: Providing and fixing factory-made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless-steel screws, joints mitered and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer s specification and direction of Engineer in- charge Extruded section profile size 42x50 mm . For Fish Landing oUBARGE BOARD: Providing and fixing Ridge accessories (500-600mm) total coated thickness, Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete.. Barge board (300 mm) . For Community Hall CURIDGE SHEET : Providing and fixing Ridge accessories (500-600mm) total coated thickness, Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete. Ridges plain(500mm). . For Community HallCúRIDGE SHEET : Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : Precoated/mill finish aluminium Ridges plain (500- 600mm) . For Fish Landing èù&RAILING Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Side Rail (MS Rectangular Steel Hollow Section Size-40mmX20mmX2mm) . For Community Hall îTRUSS Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.. For Community HallÜc Providing and fixing bolts including nuts and washers complete.. For Fish Landing & Water TankDÛDrain Cover Slab :-Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. For Fish Landing ÊìSupplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10cm length and drilling holes upto 10 mm dia. etc. complete. For Fencing.àgSTONE TILE WORK : Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade...8mm thick (mirror polished and machine cut edge)..Granite stone of any colour and shade. For Entrance GateV´WATER SUPPLY FITTINGS :- Providing and fixing PTMT pillar cock of approved quality and colour..15 mm nominal bore, 107 mm long, weighing not less than 110 gms. For Fish Landing £WATER SUPPLY FITTINGS :- Reducer for 22 mm X 15 mm outer Dia SS pipe of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard. For Fish Landing WATER SUPPLY FITTINGS :- Equal Tee for 15 mm outer dia SS pipe of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard. For Fish Landing SANITARY FITTINGS : TRAPS ; Bottle trap 31mm single piece moulded with height of270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms For Community Hall & Fish Landingó©SANITARY FITTINGS : Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe.. 32 mm dia. For Fish Landing ¡ SANITARY FITTINGS : Providing and fixing soil, waste and vent pipes :100 mm dia& Sand cas
iron S&S pipe as per IS: 1729. For Community Hall & Fish Landing ĉ̈䴀剉佒⁒倠潲楶楤杮愠摮映硩湩業牲牯漠畳数楲牯朠慬獳
癯摥焠慵楬祴 湡景爠煥極敲桳灡湡楳敺眠瑩汰獡楴潭汵敤牦浡景愠灰潲敶慭敫愠摮猠慨敤眠瑩‶浭琠楨正栠牡潢牡慢正湩敒瑣湡畧慬桳灡㔱〰㑸〵洠†䘊牯䌠浯畭楮祴䠠污…楆桳䰠湡楤杮 ᴀ܀ᰀᴀ글ࠀ䅓䥎䅔奒䘠呉䥔䝎⁓›†牐癯摩湩湡楦楸杮戠污慶癬戨慲獳 景愠灰潲敶畱污瑩ⱹ䠠杩牯氠睯瀠敲獳牵ⱥ眠瑩汰獡楴汦慯獴挠浯汰瑥ㄺ‵浭渠浯湩污戠牯ਠ潆潃浭湵瑩⁹慈汬îȈ匀乁呉剁⁙䥆呔义升㨠†倠潲楶楤杮愠摮映硩湩潤扵敬攠畱污樠湵瑣潩景爠煥極敲敤牧敥眠瑩捡散獳搠潯Ⱳ椠獮牥楴湯爠扵敢慷桳牥㌠洠桴捩Ⱬ戠汯獴愠摮渠瑵潣灭敬整㨠ਠ㜱㐮⸱ⴱㄠ〰ㅸ〰ㅸ〰ㅸ〰洠੭㜱㐮⸱⸱‱慓摮挠獡⁴物湯匠匦愠数卉ⴠㄠ㈷9ᴀᔀᰀ氀ࠀ䅓䥎䅔奒䘠呉䥔䝎⁓›†潍畤慬敓瑰捩吠湡景㔠〵‰瑌獲䌠灡捡瑩ⱹ猠極慴汢潦〱ㄭ′䅐⁘ਮ潆潃浭湵瑩⁹慈汬Yī̈圀呁剅吠乁㩋倊潲楶楤杮愠摮瀠慬楣杮漠整牲捡愨⁴污汦潯敬敶獬 潰祬瑥票敬敮眠瑡牥猠潴慲敧琠湡Ⱬ䤠⁓›㈱〷‱慭歲摥楷桴挠癯牥愠摮猠極慴汢潬正湩牡慲杮浥湥⁴湡慭楫杮渠捥獥慳祲栠汯獥映牯椠汮瑥畯汴瑥愠摮漠敶晲潬⁷楰数畢⁴楷桴畯⁴楦瑴湩獧愠摮琠敨戠獡畳灰牯⁴潦慴歮ਠ潆潃浭湵瑩⁹慈汬 ęƛЈ䔀䕌呃䥒䅃⁌䅐呒楗楲杮映牯氠杩瑨瀠楯瑮 慦潰湩⽴攠桸畡瑳映湡瀠楯瑮 慣汬戠汥潰湩⁴楷桴ㄠ㔮猠浭䘠䱒⁓噐⁃湩畳慬整潣灰牥挠湯畤瑣牯猠湩汧潣敲挠扡敬椠畳晲捡 敲散獳摥洠摥畩汣獡噐⁃潣摮極ⱴ眠瑩潭畤慬睳瑩档潭畤慬汰瑡ⱥ猠極慴汢䥇戠硯愠摮攠牡桴湩桴潰湩⁴楷桴ㄠ㔮猠浭䘠䱒⁓噐⁃湩畳慬整潣灰牥挠湯畤瑣牯猠湩汧潣敲挠扡敬攠捴獡爠煥極敲䜠潲灵䌠†潆潃浭湵瑩⁹慈汬☠䘠獩慌摮湩ŹƚĒĈ圀物湩潦楬桧⽴瀠睯牥瀠畬楷桴㈠㑘猠洠剆卌倠䍖椠獮汵瑡摥挠灯数潣摮捵潴楳杮敬挠牯慣汢湩猠牵慦散 敲散獳摥洠摥畩汣獡噐⁃潣摮極⁴污湯睧瑩‱潎㐠猠洠剆卌倠䍖椠獮汵瑡摥挠灯数潣摮捵潴楳杮敬挠牯慣汢潦潬灯†慥瑲楨杮愠敲畱物摥⸮䘠牯䌠浯畭楮祴䠠污ャᴀࠁ楗楲杮映牯挠物畣瑩 畳浢楡楷楲杮愠潬杮楷桴攠牡桴眠物楷桴琠敨映汯潬楷杮猠穩獥漠剆卌倠䍖椠獮汵瑡摥挠灯数潣摮捵潴Ⱳ猠湩汧潣敲挠扡敬椠畳晲捡⽥爠捥獥敳敭楤浵挠慬獳倠䍖挠湯畤瑩愠敲畱物摥′⁘‴煳浭⬠ㄠ堠㐠猠洠慥瑲楷敲潆潃浭湵瑩⁹慈汬îĶĈ匀灵汰楹杮愠摮映硩湩畳瑩扡敬猠穩䥇戠硯眠瑩潭畤慬汰瑡湡潣敶湩映潲瑮漠畳晲捡牯椠敲散獳湩汣摵湩牰癯摩湩湡楦楸杮㌠瀠湩㔠㘯愠灭潭畤慬潳正瑥漠瑵敬⁴湡⼵‶浡獰洠摯汵牡猠楷捴ⱨ挠湯敮瑣潩瑥愠敲畱物摥䘨牯氠杩瑨瀠畬獧琠敢甠敳湩渠湯爠獥摩湥楴污戠極摬湩獧⸩䘠牯䌠浯畭楮祴䠠污⑬ᴁ︀ࠂ䕃䱉义⁇䅆畓灰祬湉瑳污慬楴湯敔瑳湩湡潃浭獩楳湯湩景ㄠ〲‰浭猠敷灥䕂⁅‵瑳牡爠瑡摥散汩湩慦楷桴䈠畲桳䰠獥楄敲瑣䌠牵敲瑮⠠䱂䍄 潍潴Ⱳ挠慬獳漠湩畳慬楴湯›ⱂ㌠渠獯汢摡獥〳挠潬杮搠睯潲Ɽ㈠渠獯慣潮楰獥桳捡汫楫ⱴ猠晡瑥⁹潲数潣灰牥眠湩楤杮潐敷慆瑣牯渠瑯氠獥桴湡〠㤮敓癲捩慖畬䌨⽍⽍⥗洠湩浩浵㘠〮ⰰ䄠物搠汥癩牥⁹業楮畭ㄲ‰畃⽭楍Ɱ㌠〵删䵐⠠潴敬慲据獡瀠牥䤠⁓›㜳ⴴ〲㤱Ⱙ吠䑈氠獥桴湡ㄠ┰敲潭整漠汥捥牴湯捩爠来汵瑡牯甠楮⁴潦灳敥潣瑮潲湡污敲慭湩湩捡散獳牯敩湩汣摵湩慳敦祴瀠湩畮⁴潢瑬ⱳ眠獡敨獲整灭牥瑡牵楲敳㜽‵敤牧敥䌠⠠慭Ⱙ椠獮汵瑡潩敲楳瑳湡散洠牯桴湡㈠洠来桯Ɑ猠極慴汢潦㌲‰ⱖ㔠‰穈楳杮敬瀠慨敳䄠⁃畓灰祬慥瑲楨杮攠捴潣灭敬整愠敲畱物摥䘠牯†潃浭湵瑩⁹慈汬☠䘠獩慌摮湩 ˛ÊĈ匀灵汰楹杮愠摮映硩湩潭畤慬祴数㘠㘯䄠灭漠敮眠祡猠楷捴湯攠楸瑳湩潭畤慬汰瑡湡睳瑩档戠硯椠据畬楤杮挠湯敮瑣潩獮戠瑵攠捸畬楤杮洠摯汵牡瀠慬整攠捴獡爠煥極敲†潆䌠浯畭楮祴䠠污…楆桳䰠湡楤杮꜠ᴀȀࠁ牐癯摩湩湡楦楸杮映汯潬楷杮爠瑡湩湡牢慥楫杮挠灡捡瑩⁹湡潰敬䴠䍃⁂楷桴琠敨浲浯条敮楴敲敬獡湡整浲湩污猠牰慥敤獲椠硥獩楴杮挠扵捩敬瀠湡汥戠慯摲椠据畬楤杮搠楲汬湩潨敬湩挠扵捩敬瀠湡汥慭楫杮挠湯敮瑣潩獮瑥愠敲畱物摥䘠牯†潃浭湵瑩⁹慈汬ïïĈ䔀牡桴湩楷桴䜠䤮慥瑲楰数㐠㔮洠瑥敲氠湯Ⱨ㐠‰浭搠慩椠据畬楤杮愠捣獥潳楲獥湡牰癯摩湩慭潳牮⁹湥汣獯牵楷桴挠癯牥瀠慬整栠癡湩潬正湩牡慲杮浥湥⁴湡慷整楲杮瀠灩瑥眠瑩档牡潣污 潣敫愠摮猠污⁴獡爠煥極敲䘠牯†潃浭湵瑩⁹慈汬ÜÇĈ匀灵汰楹杮愠摮映硩湩潦汬睯湩潭畤慬睳瑩档猯捯敫⁴湯琠敨攠楸瑳湩潭畤慬汰瑡…睳瑩档戠硯椠据畬楤杮挠湯敮瑣潩獮戠瑵攠捸畬楤杮洠摯汵牡瀠慬整攠捴獡爠煥極敲ㄠ⼵㘱䄠猠楷捴䘠牯†潃浭湵瑩⁹慈汬´ÒĈ匀灵汰楹杮愠摮映硩湩潦汬睯湩潭畤慬睳瑩档猯捯敫⁴湯琠敨攠楸瑳湩潭畤慬汰瑡…睳瑩档戠硯椠据畬楤杮挠湯敮瑣潩獮戠瑵攠捸畬楤杮洠摯汵牡瀠慬整攠捴獡爠煥極敲㌠瀠湩㔠㘯䄠猠捯敫⁴畯汴瑥潆䌠浯畭楮祴䠠污뽬ᴀ쌀ࠀ畓灰祬湩湡楦楸杮琠潷洭摯汵瑳灥数祴数攠敬瑣潲楮慦敲畧慬潴湯攠楸瑳湩潭畤慬汰瑡湡睳瑩档戠硯椠据畬楤杮挠湯敮瑣潩獮戠瑵攠捸畬楤杮洠摯汵牡瀠慬整攠捴獡爠煥極敲䘠牯䘠獩慌摮湩덧ᴀࠀࠁ畓灰祬湩湡楦楸杮猠極慴汢楳敺䜠⁉潂⁸楷桴洠摯汵牡瀠慬整愠摮挠癯牥椠牦湯⁴湯猠牵慦散漠湩爠捥獥ⱳ椠据畬楤杮瀠潲楶楤杮愠摮映硩湩‶楰⼵‶浡獰☠ㄠ⼵㘱愠灭潭畤慬潳正瑥漠瑵敬⁴湡㔱ㄯ‶浡獰洠摯汵牡猠楷捴ⱨ挠湯敮瑣潩瑥獡爠煥極敲潆楆桳䰠湡楤杮øèĈ倀潲楶楤杮愠摮映硩湩潦汬睯湩慣慰楣祴吠♐⁎楤捳湯敮瑣牯映獵睳瑩档甠楮⁴湩楳敤琠敨攠楸瑳湩慰敮潢牡楷桴䤠䥓洠牡敫剈⁃畦敳湩汣摵湩潨敬湩挠扵捩敬瀠湡汥慭楫杮挠湯敮瑣潩獮瑥愠敲畱物摥㈳䄠吠♐⹎䘠牯䘠獩慌摮湩ᴀ가आLED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) < 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).. CRCA Sheet Body (Thickness ≥ 0.50 mm). 18- 22 watt For Community HallښوĈ匀灵汰楹杮湩瑳污慬楴湯楦瑴湩…楦楸杮整瑳湩湡潣浭獩楳湯湩景䔠敬瑣楲牤癩湥㌠瀭慨敳⠠潦䠵⽐㜠㔮偈ㄯ䠰⽐㈱㔮偈ㄯ䠵⥐⼠匠湩汧桰獡昨牯ㄠ䠠⁐ 䠲⁐ ″偈瀠浵⥰䌠湥牴晩杵污瀠浵⁰敳⁴景愠灰潲敶慭敫眠瑩牢湯敺椠灭汥敬景猠極慴汢楤浡瑥牥眠瑩⹇⹉猠捵楴湯瀠灩ⱥ猠捵楴湯猠牴楡敮Ⱳ渠湯爭瑥牵慶癬ⱥ搠汥癩牥⁹楰楰杮甠⁰潴猠畬捩慶癬污潣灭敬整桔異灭猠瑥猠潨汵敢挠畯汰摥眠瑩汥捥牴捩洠瑯牯搠楲敶漠摡煥慵整瀠睯牥猠極慴汢潦灯牥瑡潩瑡㈠〳⁖ ㄴ‵ⱖ㔠‰穈椠灮瑵瀠睯牥眠瑩佄⁌瑓牡整匯慴敤瑬瑓牡整湩汣摵湩汅捥牴捩䌠湯牴汯瀠湡汥戠慯摲攠据潬畳敲洠摡景䴠⁓桓敥⁴畤祬瀠楡瑮摥眠瑩湁楴挭牯潲楳敶瀠楡瑮潣灭敬整楦瑴摥眠瑩污汥捥牴捩污愠捣獥潳楲獥椠攮晏ⵦ湏匠楷捴ⱨ嘠汯浴瑥牥流敭整Ⱳ䤠摮捩瑡牯氠杩瑨攠捴Ⱞ†潃灭敬整眠物湩牦浯倠湡汥䈠慯摲琠慍湩䰠湩湩汣摵湩畳灰祬漠汁浵湩畩牁潭牵摥䌠扡敬漠摡煥慵整挠潲獳猠捥楴湯慅瑲楨杮眠物湡污敮散獳牡⁹慭整楲污潦桴慳敭湩汣摵湩潣瑳漠䍃瀠浵⁰潦湵慤楴湯眠瑩慢敳瀠慬整挠浯汰瑥湡瑯敨捡散獳牯敩湡慬潢牵挠慨杲潦湩瑳污慬楴湯漠桴異灭攠捴污潣灭敬整愠灳捥晩敩湡楤敲瑣摥戠⁹桴敄慰瑲敭瑮眠瑩湏敹牡眠牡慲瑮⁹牦浯琠敨搠瑡景挠浯業獳潩楮杮愠摮猠瑡獩慦瑣牯⁹整瑳湩条楡獮⁴湡⁹慭畮慦瑣牵湩敤敦瑣䥛湡⁹畳档搠晥捥⁴獩映畯摮搠牵湩桴敹牡映潲桴慤整漠湩瑳污慬楴湯愠摮猠瑡獩慦瑣牯⁹整瑳湩Ⱨ猠灵汰敩楷汬栠癡潴爠捥楴祦琠敨搠晥捥⁴瑡琠敨物挠獯⁴湡楲歳☠椠敮散獳牡⁹敲汰捡桴異灭猠瑥崮吠獥⁴敃瑲晩捩瑡景倠浵Ɒ䴠瑯牯瑓牡整Ⱳ倠湡汥䈠慯摲瑥映潲桴慭畮慦瑣牵牥猠慨汬栠癡潴戠畳浢瑩整㩤ㄊ䠠⁐景瀠浵⁰琨敢瀠潲楶敤⥤匠湩汧桐獡†䘠牯䌠浯畭楮祴䠠污㙬ᴆ昀ࠀ畓灰祬湉瑳污慬楴湯敔瑳湩湡潃浭獩楳湯湩景㔠坋传晦䜠楲潓慬潐敷汰湡†潆潃浭湵瑩⁹慈汬TĆȈ倀潲整瑣潩潗歲†††††††††††††††††††††††††††††††††††††††††††††††倠潲楶楤杮愠摮氠祡湩楐捴楨杮漠汳灯獥氠楡癯牥瀠敲慰敲楦瑬牥洠摥慩映牯攠扭湡浫湥⁴牰瑯捥楴湯挠浯汰瑥獡瀠牥搠慲楷杮愠摮吠捥湨捩污猠数楣楦慣楴湯sᴀ瀀ᰀ혀ࠁ牐瑯捥楴湯圠牯獫†††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††牐癯摩湩湡慬楹杮漠潢汵敤灡潲慬摩椠楷敲挠慲整楷桴㐠浭搠慩䜠⁉楷敲挠湯潦浲湩潴䤠㩓㠲‰湡卉㐺㈸‶湩ㄠ〰浭砠ㄠ〰浭敭桳⠠潷敶楤条湯污祬 湩汣摵湩〱瀠牥挠湥⁴硥牴潦慬獰愠摮樠楯瑮慬摩楷桴猠潴敮戠畯摬牥睳楥桧湩湧瑯氠獥桴湡㔲欠敧捡慨数牤睡湩湡整档楮慣灳捥晩捩瑡潩獮䌠慬獵㌱ǖ̈䈀牯湩㩧䈊牯湩⽧牤汩楬杮戠牯敷汬漠敲畱物摥搠慩映牯挠獡湩⽧猠牴楡敮楰数祢猠極慴汢敭桴摯瀠敲捳楲敢湩䤠㩓㈠〸‰瀨牡⁴⥉湩汣摵湩潣汬捥楴杮猠浡汰獥映潲楤晦牥湥⁴瑳慲慴牰灥牡湩湡畳浢瑩楴杮猠牴瑡档牡⽴戠牯潬Ⱨ椠据畬楤杮栠物…畲湮湩档牡敧景愠汬攠畱灩敭瑮ⱳ琠潯獬汰湡獴☠洠捡楨敮楲獥爠煥極敲潦桴潪Ɫ愠汬挠浯汰瑥獡瀠牥搠物捥楴湯漠湅楧敮牥椭档牡敧灵潴㤠‰敭牴敤瑰敢潬⁷牧畯摮氠癥汥⸮䄮汬琠灹獥漠潳汩㨠㌠〰洠楤但⁒佂䕒圠䱅Lᴀࠀᰀ준ᴁ猀ࠁ慃楳杮倠灩㩥匊灵汰楹杮獡敳扭楬杮潬敷楲杮愠摮映硩湩湩瘠牥楴慣潰楳楴湯椠潢敲眠汥ⱬ甠灮慬瑳捩穩摥倠䍖洠摥畩敷汬挠獡湩䌨⥍瀠灩景爠煥極敲楤ⱡ挠湯潦浲湩潴䤠㩓ㄠ㠲㠱湩汣摵湩敲畱物摥栠物湡慬潢牵挠慨杲獥楦瑴湩獧☠愠捣獥潳楲獥攠捴污潣灭敬整潦污敤瑰獨獡瀠牥搠物捥楴湯漠湅楧敮牥ⴠ湩挭慨杲⸮⸮⸮⸮⸮ㄠ〰洠潮業慮楳敺搠慩ਠ但⁒佂䕒圠䱅Lᴀഀᰀ昀ᴁ戀ࠁ捓敲湥⠠䵒⥓瀠灩獥畓灰祬湩Ⱨ愠獳浥汢湩Ⱨ氠睯牥湩湡楦楸杮椠敶瑲捩污瀠獯瑩潩湩戠牯敷汬甠灮慬瑳捩穩摥倠䍖洠摥畩敷汬猠牣敥刨卍 楰数楷桴爠扩ⱳ挠湯潦浲湩潴䤠㩓ㄠ㠲㠱湩汣摵湩楨敲☠氠扡畯档牡敧ⱳ映瑩楴杮…捡散獳牯敩瑥愠汬挠浯汰瑥ⱥ映牯愠汬搠灥桴ⱳ愠数楤敲瑣潩景䔠杮湩敥湩挭慨杲⸮⸮〱‰浭渠浯湩污猠穩楤䘊剏䈠剏⁅䕗䱌ŕɄ̈䴀⁓楐数畓灰祬湩Ⱨ愠獳浥汢湩Ⱨ氠睯牥湩湡楦楸杮椠敶瑲捩污瀠獯瑩潩湩戠牯敷汬剅⁗䔨敬瑣楲敒楳瑳湡散圠汥敤⥤䘠⁅ㄴ‰業摬猠整汥猠牣睥摥愠摮猠捯敫整⽤汰楡湥敤慣楳杮瀠灩獥漠敲畱物摥搠慩潣普牯業杮琠卉›㈴〷景爠灥瑵摥☠愠灰潲敶慭敫湩汣摵湩慰湩整楷桴漠瑵楳敤猠牵慦散眠瑩睴潣瑡景愠瑮捩牯潲楳敶瀠楡瑮漠灡牰癯摥戠慲摮愠摮洠湡晵捡畴敲湩汣摵湩敲畱物摥栠物…慬潢牵挠慨杲獥楦瑴湩獧☠愠捣獥潳楲獥污潣灭敬整潦污敤瑰獨獡瀠牥搠物捥楴湯漠湅楧敮牥椭档牡敧⸮⸮⸮㔱‰浭渠浯湩污猠穩楤慨楶杮洠湩浩浵眠污桴捩湫獥⸵〰洠੭但⁒佂䕒圠䱅Lᴀऀᰀ㜀ᴂ준ࠂ敄敶潬浰湥⁴景琠扵敷汬›†䐊癥汥灯敭瑮漠畴敢眠汥湩愠捣牯慤据楷桴䤠⁓›㠲〰⠠慰瑲䤠 湡卉ㄺㄱ㤸潴攠瑳扡楬桳洠硡浩浵爠瑡景甠慳汢慷整楹汥楷桴畯⁴慳摮挠湯整瑮⠠敢潹摮瀠牥業獳扩敬氠浩瑩Ⱙ眠瑩敲畱物摥挠灡捡瑩⁹楡潣灭敲獳牯畲湮湩桴潣灭敲獳牯映牯爠煥極敲楴敭琠汩敷汬椠畦汬⁹敤敶潬数Ɽ洠慥畳楲杮礠敩摬漠敷汬戠⁹嘢•潮捴敭桴摯漠湡⁹瑯敨灡牰癯摥洠瑥潨Ɽ洠慥畳楲杮猠慴楴敬敶…牤睡搠睯瑥戠⁹瑳灥搠慲⁷潤湷洠瑥潨Ɽ挠汯敬瑣湩慷整慳灭敬…敧瑴湩整瑳摥椠灡牰癯摥氠扡牯瑡牯ⱹ椠振搠獩湩敦瑣潩景琠扵睥汥ⱬ愠汬挠浯汰瑥ⱥ椠据畬楤杮栠物…慬潢牵挠慨杲獥漠楡潣灭敲獳牯潴汯…捡散獳牯敩瑥ਬ污獡瀠牥爠煥極敲敭瑮愠摮搠物捥楴湯漠湅楧敮牥椭档牡敧ਮ但⁒佂䕒圠䱅Lᴀᤀᰀ밀ᴂऀMS cap: Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:…...........150 mm dia FOR BORE WELLÜƘ̈䰀睯牥湩景挠汯浵楰数›倊潲楶楤杮愠摮映硩湩桃潬楲慮整潐祬楶祮桃潬楲敤⠠偃䍖 楰数ⱳ慨楶杮琠敨浲污猠慴楢楬祴映牯栠瑯☠挠汯慷整畳灰祬椠据畬楤杮愠汬䌠噐⁃汰楡…牢獡桴敲摡摥映瑩楴杮桔獩椠据畬敤潪湩楴杮漠楰数…楦瑴湩獧眠瑩湯瑳灥䌠噐⁃潳癬湥⁴散敭瑮牴湥档湩Ⱨ爠晥汩楬杮☠琠獥楴杮漠潪湩獴挠浯汰瑥獡瀠牥搠物捥楴湯漠湅楧敮牥椠桃牡敧⸮⸮⸮⸮⸮〴洠潮業慮楤楐数ੳ但⁒佂䕒圠䱅Lᴀᨀᰀ謀ᴁࠁ片癡汥瀠捡楫杮椠畴敢敷汬片癡汥瀠捡楫杮椠畴敢敷汬挠湯瑳畲瑣潩湩愠捣牯慤据楷桴䤠㩓㐠㤰ⰷ湩汣摵湩牰癯摩湩牧癡汥映湩⽥洠摥畩⽭挠慯獲ⱥ椠敲畱物摥朠慲楤杮☠猠穩獥愠数捡畴污爠煥極敲敭瑮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩挭慨杲䘊剏䈠剏⁅䕗䱌ýअ̈䘀䱁䕓䌠䥅䥌䝎›††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††倠潲楶楤杮愠摮映硩湩慦獬散汩湩瑡愠汬栠楥桧⁴湩汣摵湩牰癯摩湩湡楦楸杮漠牦浡潷歲洠摡景猠数楣污猠捥楴湯ⱳ瀠睯牥瀠敲獳摥映潲⹍⹓猠敨瑥湡慧癬湡穩摥眠瑩楺据挠慯楴杮漠㈱‰浧⽳煳戨瑯楳敤椠据畬楳敶 獡瀠牥䤠⁓›㜲‷湡潣獮獩楴杮漠湡汧汣慥獴漠楳敺㈠‵浭眠摩⁸⸱‶浭琠楨正眠瑩汦湡敧景㈠‷浭愠摮㌠洷Ɑ愠⁴㈱〰洠散瑮敲琠散瑮敲湯汦湡敧映硩摥琠桴散汩湩楷桴搠獡慦瑳湥牥ㄠ⸲‵浭搠慩砠㔠洰潬杮眠瑩洶楤潢瑬ⱳ漠桴牥映慬杮景挠敬瑡映硩摥琠桴湡汧慨杮牥景㈠砵〱へ㔮‰浭漠敲畱物摥氠湥瑧楷桴渠瑵…潢瑬景爠煥極敲楳敺愠摮漠桴牥攠摮漠湡汧慨杮牥映硩摥眠瑩湩整浲摥慩整䜠䤮档湡敮獬㐠砵㔱へ㤮洠畲湮湩瑡琠敨猠慰楣杮漠㈱〰洠散瑮敲琠散瑮敲潴眠楨档琠敨挠楥楬杮猠捥楴湯〠㔮洠桴捩潢瑴浯眠摥敧漠〸洠楷桴琠灡牥摥映慬杮獥漠㘲洠慥档栠癡湩楬獰漠〱㔮洠Ɑ愠⁴㔴‰浭挠湥牴潴挠湥牴ⱥ猠慨汬戠楦數湩愠搠物捥楴湯瀠牥数摮捩汵牡琠⹇⹉椠瑮牥敭楤瑡档湡敮楷桴挠湯敮瑣湩汣灩慭敤漠瑵漠⸲㐶洠楤⁸㌲‰浭氠湯⹇⹉眠物瑡攠敶祲樠湵瑣潩Ɱ椠据畬楤杮映硩湩数楲敭整档湡敮獬〠㔮洠桴捩㜲洠楨桧栠癡湩汦湡敧景㈠‰浭愠摮㌠‰浭氠湯Ⱨ琠敨瀠牥浩瑥牥漠散汩湩楦數潴眠污⽬慰瑲瑩潩楷桴琠敨栠汥⁰景爠睡汰杵瑡㐠〵洠散瑮敲楷桴㈠洵潬杮搠祲眠污捳敲獷䀠㈠〳洠湩整癲污湩汣摵湩楦楸杮漠祧獰浵戠慯摲琠散汩湩敳瑣潩湡数楲敭整档湡敮楷桴琠敨栠汥⁰景搠祲眠污捳敲獷
of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board celling conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) sqm 1145.955. For Community Hall ò
PAINTING: Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:.. - One or more coats on old work. . For Fish Landing, Gate
PAINTING: Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm . For Fish Landing,
TILES: Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete..WALL TILES. For Community Hall, Fish Landing
TILES: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm sqm. For Community Hall, Fish Landing
DOOR FITTINGS : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. 200x10 mm For Community Hall,
DOOR FITTINGS Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm . For Community Hall,
DOOR FITTINGS Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm . For Community Hall,
PVC DOOR SHUTTER Providing and fixing to existing door frames. 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter stles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. For Community Hall, Fish Landing
PAINTING WORK Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. For Community Hall, Fish Landing
ROOFING SHEET : Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. For Community Hall
Roofing sheet :- Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. For Fish Landing
TRUSS Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes . For Community Hall
Steel truss :- Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes . For Fish Landing & Water Tank
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. .Angle Section ISA 50x50x3. For Water Tank
EPOXY STEEL PAINT :- Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work. For Community Hall & Fish Landing
ROLLING SHUTTERS : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.... 80x1.20 mm M.S. laths with 1.20 mm thick top cover. For Fish Landing
Providing and fixing ball bearing for rolling shutters. For Fish Landing
Ramp Railing :- Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.G.I. pipes 50mm dia. For Fish Landing
CEMENT PLASTER (IN FINE SAND): 15 mm cement plaster on the rough side of single or half brick wall of mix .1:4 (1 cement: 4 fine sand). For Septic tank
MANHOLE COVER : Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. Circular shape 450 mm internal diameter. For Septic tank
WATER PROOFING : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. For Septic tank
PCC :- Plain cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). For Chainlink fench
CHAINLINK FENCH : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm. For Chainlink fench
STEEL GATE : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer…......... M.S. tube. For Chainlink fench Gate
WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes.. For Community Hall
WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.. External work. 25 mm nominal dia Pipes. For Fish Landing
WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.... 15 mm nominal dia Pipes For Fish Landing
WATER SUPPLY FITTINGS :- Providing and fixing PTMT bib cock of approved quality and colour… 15mm nominal bore, 86 mm long, weighing not less than 88 gms. For Fish Landing
WATER SUPPLY FITTINGS :- Elbow 90° for 15 mm outer dia SS pipe of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard. For Fish Landing
SANITARY FITTINGS : STOP COCK Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore For Community Hall
SANITARY FITTINGS : PILLER COCK Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps For Community Hall
SANITARY FITTINGS : WC PAN Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid For Community Hall
SANITARY FITTINGS : URINAL BASIN Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern For Community Hall
SANITARY FITTINGS : Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests For Fish Landing
SANITARY FITTINGS : Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : :.....100 mm diameter For Fish Landing
SANITARY FITTINGS : Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : :.....100 mm diameter S.W. pipe For Fish Landing
SANITARY FITTINGS : Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. For Fish Landing
SANITARY FITTINGS : Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. For Fish Landing
SANITARY FITTINGS : Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms For Fish Landing
SANITARY FITTINGS : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.. For Fish Landing
SANITARY FITTINGS : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. For Fish Landing
SANITARY FITTINGS : Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. For Fish Landing
SANITARY FITTINGS : Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36mm height of approved quality and colour, weighing not less than 300 gms… For Fish Landing
SANITARY FITTINGS : Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48gms. For Fish Landing
SANITARY FITTINGS : Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. For Fish Landing
SANITARY FITTINGS : Providing and fixing 100 mm sand cast Iron grating for gully trap. For Fish Landing
SANITARY FITTINGS : Providing and fixing plain bend of required degree… 100 mm dia...Sand cast iron S&S as per IS - 1729. For Fish Landing
SANITARY FITTINGS : Providing and fixing collar :… 100 mm dia...Sand cast iron S&S as per IS - 1729. For Fish Landing
SANITARY FITTINGS : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore. For Community Hall
Supplying and fixing PVC batten / angle holder including connections etc as required. For Fish Landing
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet. For Community Hall
Installation of Exhaust Fan in the existing opening including making good the damage, connection, Testing, commissioning etc required. Upto 450mm sweep. For Fish Landing
Pen Culture: Construction of Pen Culture with Bamboo (1st Class) 85 mm - 100 mm dia, 4.5 m - 5.5 m long, vertically placed at 2.00 m centre to centre driven 1.50 m below ground/bed level and 2.50 m above ground/bed level tied with Jati or Bethua bamboo 50mm to 100 mm dia and 6m long above groung level horizontally in two rows at 2.00 m apart, Fencing with split bamboo kamis in horizontal direction at 300 mm c/c and vertical direction at 800 mm c/c having tied with coconut fiber two poly twisted rope etc. manually with provision of hired country boat (2 nos.), fitting and fixing of PEN culture Net 115 GSM HDPE mono shade, 45 ply Nylon, 210D, 24 mm mesh size net with boarder rope of 10 mm dia Polypropylene and tie rope in every 2 meter intervals conforming to technical requirement of Textiles - Twisted Nylon Fish-Net Twines as per IS 4401-2006, complete as per drawings and technical specifications as directed by Engineer in-charge.
Katal Fishing Erection of Fish Agregating Device as Katal / Jeng Fishing circular structure at Beel/ Wetland covering 0.25 Ha water area with Bamboo Bholuka or Barua 55mm to 100mm dia and 6m long vertical member placed at 3.00 m centre to centre, Jati or Bethua Bamboo 50mm to 100 mm dia and 6m long tie horizontally with vertical members (Kamis)- one row and Inclined members (strut) to support each vertical member driven 2.00 m below the ground/bed level and 3.50 m to 4.00 m above the ground/bed level tied with coconut fiber two ply twisted rope etc. manually with provision of hired country boat complete as per drawings and technical specifications as directed by Engineer in-charge.
Bamboo Partition structure Construction of Bamboo Screening Structure by placing and arranging of whole Bamboo in barricade type with Bamboo Bholuka or Barua 55mm to 100mm dia and 6m minimum in length, vertically placed two rows in staggered manner at 2.50 m centre to centre, driven 2.00 m below ground/bed level and 4.00 m above ground/bed level tied with Jati or Bethua bamboo 50mm to 100 mm dia and 6m long above groung level horizontally in two rows at convenient level having tied with coconut fiber two poly twisted rope etc. manually with provision of hired country boat (2 nos.), fitting and fixing of 72 ply HDPE 30mm kk mesh size net with boarder rope of 32mm dia TUF PP IR 3 strand 220 mtr : 101 kg and tie rope in every 2 meter intervals conforming to technical requirement of Textiles - Twisted Nylon Fish-Net Twines as per IS 4401-2006, complete as per drawings and technical specifications as directed by Engineer in-charge.
SOLAR LAMP: Supply, Installation, Testing and commissioning of a Complete solar street-lighting system, including a 160Wp crystalline silicon solar photovoltaic module supplied with a compatible module mounting structure, clamps, fasteners, and UV-resistant cable tails, with test certification conforming to IEC 61215 (Edition II)/IS 14286 and IEC 61730 from a NABL or IECQ accredited laboratory. The system shall incroporate a Lithium Iron Phosphate (LiFePO4) battery of 12.8V nominal voltage and 42 Ah capacity, equipped with an integrated Battery Management System (BMS) providing protections against over/under-voltage, over-current, short-circuit, over-temperature, and ensuring cell balancing, duly certified to IEC 62133-2011 or the latest BIS standard by a BIS-recognized lab or MNRE-accredited test centre. The MPPT charge controller, integrated with the luminaire and battery, shall operate at 12.8 V noinal, have a maximum current rating of 6A/12 A/14 A as required and provide automatic dusk-to-dawn operation, LiFEPO4 charging profiles, and full electronic protection. The LED street-light luminaire shall be rated at 30W(+5%), with high-effciency optics, a driver compatible with the MPPT output, and ingress protection of IP66 or higher, complying with relevent BIS standards, The system shall be mounted on a 6m long 2.2mm thick tubular hot-dip galvanized GI pole conforming to IS 1161 and IS 4736 complete with a single-arm bracket, MMS, and light arm to hold the luminaire and PV module, along with all necessary clamps and fasteners. The work shall include complte erection on a prepared foundation, all wiring and interconnection, functional testing (dusk-to-dawn operation) in the presence of the Engineer-in-Charge, and submission of as-built documentation. The contractor shall also provide a Comprehensive Maintenance Contract (CMC) for a period of five years from the date of commissioning covering preventive and breakdown maintenance, replacement of defective parts, and maintenance of illuinataion levels as specified.
INFORMATION BOARD: Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
EMP: Implementation & Monitoring of Environmental Management Plan (EMP) as the provisions in the Bidding Document Vol-2, for which the estimated cost is Rs.1,15,000/=
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.47 MB
LetterofPriceBid.pdf
Tender Documents • 0.49 MB
EMPVol2.pdf
Tender Documents • 0.60 MB
DrawingsVol3.pdf
Tender Documents • 9.79 MB
HalowadalBeelVol1.pdf
Tender Documents • 1.95 MB
BOQ_82262.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid