Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹89,400+₹1,560 (1.78%)Qualified Make: EXIDE
Model: EXIDE INTA BRIGHT 12V 150 36 MONTH WARRANTY 196 INDRA NAGAR G FACTORY G T ROAD BAMRAULI ALLAHABAD UTTAR PRADESH 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | Make: EXIDE
Model: EXIDE INTA BRIGHT 12V 150 36 MONTH WARRANTY | L2 | Qualified | |
| 2 | L3₹90,792+₹2,952 (3.36%)Qualified Make: EXIDE
Model: EXIDE IPT1500 120 2 SWARUP BHAWAN NEAR LIC BUILDING SEVOKE ROAD DARJEELING WEST BENGAL 734001 | JALPAIGURI | WEST BENGAL | 734001 | Make: EXIDE
Model: EXIDE IPT1500 | L3 | Qualified | |
| 3 | L4₹93,600+₹5,760 (6.56%)Qualified Make: YASHPOWER
Model: YASHPOWER YPS12 - 150 D 115 SECTOR 9 NEW VIJAY NAGAR GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | UTTAR PRADESH | 201009 | Make: YASHPOWER
Model: YASHPOWER YPS12 - 150 | L4 | Qualified | |
| 4 | L5₹94,000+₹6,160 (7.01%)Qualified Make: EXIDE
Model: Exide Insta Brite IB 1500 01 PAHARTOLI BHAGWATI NAGAR HEHAL RANCHI JHARKHAND 834005 | RANCHI | JHARKHAND | 834005 | Make: EXIDE
Model: Exide Insta Brite IB 1500 | L5 | Qualified | |
| 5 | Qualified Make: LUMINOUS
Model: IL1830FP Luminous Flat Plate Battery (150AH-12V) LIG 14 KOTRA SULTANABAD NEAR VAISHALI SQUARE TT NAGAR BHOPAL MADHYA PRADESH 462003 | BHOPAL | MADHYA PRADESH | 462003 | Make: LUMINOUS
Model: IL1830FP Luminous Flat Plate Battery (150AH-12V) | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
15 Nov 2018, 12:00 pmClosed
lead acid battery MSME Exemption For Years Of Experience And Turnover No Lead Acid Battery ( 8 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992 Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments
Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992
Stationary cells and Batteries
Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991
Stationary Valve Regulated Lead Acid Batteries conforming to 1/4 IS:15549/2005
Lead- Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995
Lead- Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Nominal Voltage of Battery (volts) 12.0 Volt 2.0 Volt
6.0 Volt
12.0 Volt Material of container Polypropylene Hard Rubber
Fibre Reinforced Plastics (FRP)
Polypropylene
ABS Rated Capacity at C20 discharge (AH) 150 1-300 Warranty (Years) 2 Years 1 Year
2 Years
3 Years
4 Years
5 Years Battery Condition Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 9000 * Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab Manak Bhavan
9 Bahadur shah Zafar Marg
New Delhi-110002 * Name of the Lab Bureau of Indian Standards * Test Report No. R-410J5563 * Test Report Date 08.11.2017 * Compulsory Registration (CRS) of R-410J5563 * 2/4 BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ravindra Kartik Kumbhare 262001
O/O The DIG
SHQ
SSB Pilibhit
House No. 10
Kunwar Garh
Near Dudhiya Mandir
Pilibhit 8 15
788222
GEM/2018/B/110523
lead acid battery
15 days
Uttar Pradesh; Pilibhit
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| lead acid battery MSME Exemption For Years Of Experience And Turnover No Lead Acid Battery ( 8 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992 Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments | - | - | - |
| Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992 | - | - | - |
| Stationary cells and Batteries | - | - | - |
| Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 | - | - | - |
| Stationary Valve Regulated Lead Acid Batteries conforming to 1/4 IS:15549/2005 | - | - | - |
| Lead- Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 | - | - | - |
| Lead- Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Nominal Voltage of Battery (volts) 12.0 Volt 2.0 Volt | - | - | - |
| 6.0 Volt | - | - | - |
| 12.0 Volt Material of container Polypropylene Hard Rubber | - | - | - |
| Fibre Reinforced Plastics (FRP) | - | - | - |
| Polypropylene | - | - | - |
| ABS Rated Capacity at C20 discharge (AH) 150 1-300 Warranty (Years) 2 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 3 Years | - | - | - |
| 4 Years | - | - | - |
| 5 Years Battery Condition Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 9000 * Weight of Dry Battery (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab Manak Bhavan | - | - | - |
| 9 Bahadur shah Zafar Marg | - | - | - |
| New Delhi-110002 * Name of the Lab Bureau of Indian Standards * Test Report No. R-410J5563 * Test Report Date 08.11.2017 * Compulsory Registration (CRS) of R-410J5563 * 2/4 BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ravindra Kartik Kumbhare 262001 | - | - | - |
| O/O The DIG | - | - | - |
| SHQ | - | - | - |
| SSB Pilibhit | - | - | - |
| House No. 10 | - | - | - |
| Kunwar Garh | - | - | - |
| Near Dudhiya Mandir | - | - | - |
| Pilibhit 8 15 | - | - | - |
Exempted
15 Nov 2018
26 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_788222.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .