Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹48.9 L+₹3.2 L (6.88%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹49.6 L+₹3.8 L (8.38%)Rejected-AOC SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | L3 | Rejected-AOC REJECTED | |
| 4 | Rejected-Technical | - | Rejected-Technical REF TECHNICAL EVALUATION DOCUMENT | |
| 5 | Rejected-Technical KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | - | Rejected-Technical REF TECHNICAL EVALUATION DOCUMENT |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
29 Dec 2021, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVISION OF SHED FOR DG SHED AND TRANSFORMER AT ICGS VERAVAL, IANZ VILLAGE ALONGWITH PROVISION OF SCREENING WALL AND CONNECTED WORK AT CG JETTY, ICGS VERAVAL AND PROVN OF BORE WELL AT OTM/MARRIED ACCN AT INAZ VILLAGE AT ICGS VERAVAL AND DG SET PBR
2021_MES_491889_1
8675
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Porbandar
Please refer tender Documents
8 documents required · 8 mandatory
₹500
GE I CG Porbandar
₹92,000
Yes
15 Mar 2022
2 Dec 2021
30 Dec 2021
2 Dec 2021
29 Dec 2021
16 Dec 2021
2 Dec 2021 - 15 Dec 2021
Amount
SCHEDULE 'A'
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.
Excavation in trenches not exc 1.5m wide and n exc 1.5m in depth for foundation etc and getting out in soft/loose soil.
M&L PCC 1:4:8 type-D2 using 40mm graded stone aggregate in foundations filling and mass concrete etc. complete.
M&L precast PCC block masonary with solid blocks made of PCC 1:3:6 type C1 using 20mm graded aggregate,exc 10 cm in width and set in CM 1:6 complete.
M&L for RCC nominal mix,1:2:4 type B1 using 20 mm graded agg,in foundations,footings,foundation beams,plinth beams etc complete.
M&L for RCC nominal mix,1:2:4 type B1 using 20 mm graded agg,in columns,pillars,piers,posts and struts etc complete.
Form work to sides of concrete foundations,footings,bases of columns for rough finished surfaces of concrete.
Form work to sides of columns,pillars,posts and stanchions for rough finished surfaces of concrete.
S&F TMT steel bars in reinforcement 10mm dia and over cut to length, bend to shape required, incl cranking,bending and binding with and incl MS wire (Annealed) not less than 0.9 mm dia etc complete.
S&F TMT steel bars 5mm dia and over upto and incl 10 mm dia in stirrups, spacers and binders etc complete.
S&F plate girder or single stanchions, built up of one beam or chennel section with flange plates, caps, bases,angle brackets,cleats,and other connections.
S&F roof trusses (framed) ,trussed,purlins,rails and fastings and heavy brackets,rafters,wind ties includung distance pieces,cleats etc.
S&F expanded metal exc 4kg per sqm in partitions etc., cut to length, bent to shape required and tying with a incl annealed MS wire n.less than 0.90 mm dia or fixing with galvanised steel staples fixed complete to wood or steel members.
M&L for PCC cast in situ ,1:2:4 type B1 using 20mm graded aggregate,as in lintels upto 1.5 m clear span,cills,steps,bands,copings etc complete.
M&L for plastering 15mm thick in cement mortar 1:6 on masonary or concrete internal surfaces of walls, finishing the surfaces even and fair without using extra cement, complete all as specified and directed.
M&L for plastering 15mm thick in cement mortar 1:4 on masonary or concrete surfaces of walls, finishing the surfaces even and fair without using extra cement, complete all as specified and directed.
M&L for three coats of white wash over new plastered surfaces incl preparation of surfaces.
M&L for two coats cement base paint over one coat of primer incl preparation of new surfaces.
M&L for two coats of synthetic enamel paint over steel surfaces including zinc chrome primer.
S & F pre-painted galvalum aluminium zinc coating GI based corrogated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F pre-painted galvalum aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M & L or moorum filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and rammed incl watering.
M&L for broken stone hardcore of gauge not exc.63mm ,deposited,spread and levelled in layers not exc.15cm thick,watered and rammed to a true surface.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate (75 mm thick) , as in floor toping, finishing the surfaces even and fair without using extra cement complete all as specified and directed.
M&L for plastic dividing strips, 38 mm wide, 3mm thick, inserted in position to conform to design,in floors,plinth protection etc complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protections, finishing the surfaces even and smooth without using extra cement all as specified.
Returning,filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm in soft/ loose soils.
Removing excavated materials(Soils) exc 250m but n exc. 500 m out of defence land.
Mild steel tower bolt with 10mm dia bright bolt of length 200mm, stove enameled black etc all as specified.
Mild steel sliding door bolt of size 250mm clip type, stove enameled black with bright bolt not less than 16mm dia, with and including a minimum of 6 bolts and nuts, four on bolt clips and two on staple plate & fixed, complete all as specified and directed.
M&L for MS works in stairs/ladder (framed) including stringers, treads, landing, balusters, hand rails etc including cleats, brackets, etc complete.
cutting holes in PCC block walls built in cement mortar for inserting holdfasts and making good in CM 1:3 or cement concrete 1:2:4 type B1,depth of holes n exchalf brick ect complete.
S&F precast cement concrete jallies 25 mm thick,1:2:4 type B0 set in cement mortar 1:4 etc complete.
Broken stone hardcore of gauge not exc.63mm ,deposited,spread and levelled in layers not exc.15cm thick,watered and rammed to a true surface.
M&Lfor PCC 1:3:6 type C-1 using 20mm graded stone aggregate (75 mm thick) , as in sub base of floor , finishing the surfaces even and rough etc complete all as specified and directed.
M&L for 25 mm thick fine sand layer filling under paver blocks including watering and consolidation etc complete.
M&L 60mm thick machine pressed pre cast concrete interlocking pavor block any shape and size conferming to IS 15658-2006, M-35 grade with greay cement and pigment etc complete.
Supply, Installation, testing and commissioning of silent diesel engine driven generating set,415volt, 3 phase, 4wire,engine as per is 10002/10001 and alternator as per is 13364 of capacity 62.5 KVA at 0.8 PF, complete with sound proof canopy made of powder coated with specially designed lifting hooks, meet the latest CPCB norms of 75DB at 1 M distance all as spd and directed and comprising of following : (a) Engine: water cooled, four stroke, diesel engine for 62.5 KVA alternator as per is 10002/10001 with sensor for low oil pressure, high water temprature including microprocessor based engine control panel, 12V DC start system with battery and fuel tank for 8 hr run all as spd and directed. (b) Alternator: alternator of rated capacity 62.5 KVA at1500 RPM, 0.8 lagging pf, 415 volts, 3 phase, 4 wire, self excited, self regulated and avr with +- 1% voltage regulation.
(c) AMF panel: cubical type, floor mounting control panel with hinged door, 3 phase 4 wire system, made of CRCA sheet of 3.15 mm out door type thick complete all as specified and directed. Note : The Genset should be supplied through authoirsed dealer of OEM. (i) MCCB 100 Amp,tp, microprocessor based - 02 Nos (ii) Power contactor 100 Amp, 4 pole contactor for alternator/main - 02 Nos (iii) Microprocessor based AMF Module. (iv) Multifuctional meter & pcc 0301 for water treatment/ lube oil pressure/ voltage / ampere/ frequency /KW/ KVA/running hr counter.
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 95 Sqmm 3.5 Core laid in trenches/along the wall/pole including making all connections complete as required at site and as directed. Make : Polycab/Havells/RR Kabel/Plaza
S & F of GI steel tubing light grade 80 mm dia for laying in ground and road crossing along the pole in coping etc for cable protection including necessary fittings, clamps for supports, etc and all as specified and directed. Make - Tata/Jindal/Surya Prakash
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
Supply and lay 77 /63 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge.
M&L for bore Earthing, 150 mm bore for earthing with maintenance free chemical earthing using copper electrode of size 19 mm dia - 01 No, 3 m long, Copper earth strip, excavation and earth work, back fill with compound (Chemical for earth enhancer gel 2 x 25Kg) - 01 set. all as directed, shall be deemed to be included in the unit rate. Note: (i) IR Value should be less than 1.0 ohm. (ii) Copper earth stip of size 25 x 3 mm including installation 7.5 m (Copper purity not less than 99%) is deemed to be included in the unit rate. (iii) Suitable FRP Chamber should be included in the unit rate.
Material and labour for drilling trial bore through direct hammering (DTH) technique in any type of strata consisting of 300 mm dia drill bit for depth upto 200 Mtr in sequance from ground level as given below for bore well complete as per IS- 2800 Part-1 1991. The following tests and reporting will be carried out by the contractor and approved by GE all as per IS- 2800 part 1 1991:- (i) Recording the well discharge during driling by a 90 degree V-notch (ii) Recording the water bearing horizon . (iii) Taking the samples from the bore well cutting for every 3 meter interval and every change in slrata if less than 3meter. (iv) Prepartion of litho logs based on these samples.(v) Drill time log to be prepared and prescribed.(vi) Aquifer performance tests at constant discharge with draw down and recovery reading.(vii) Interpretation of data and preparation of hydro scientific report for designing of submersible pump and artificial recharge studies.
Supply assembling, jointing, lowering and fixing in the bore hole uPVC Casing pipe of Nominal Dia 200 mm (medium well), 7.5 mm thickness.confirming to IS12818-2010 including providing peagravel of 8 mm to 4.6mm size for packing around the casing/slotted pipe in bore well all as specified and directed. Make: Astral/Ashirwad/Ajay
All as per item above but slotted pipe.
S&F ball plug 200mm bore all as specified and directed.
S&F well cap 200mm size threaded and similar to housing pipe all as specified and directed.
S&F 2 Nos MS flat iron 100mmx10mm thick size clamp for holding with upto 300mm bore housing pipe including casting of PCC block of size 1200mmx1000mmx1000mm in PCC (1:2:4) type B-1 using 20mm graded stone aggregate including 150mm bore MS pipe 2 No. each, 1.5 metre long with cap plug and cap top for feeding pea gravel for each bore well as specified and directed.
Supply only strata sample box with glass cover 3mm thick having internal dimension 100x100x600mm made out of 20mm thick wood with hinges, hasp and staple including polishing complete with samples at various strata met in boring including strata chart in duplicate
Yield testing of the tube well as specified and directed to determine the safe pumping capacity of tube well.
Chemical and bacteriological testing or water sample from approved laboratory to ensure portability of water complete all as directed.
Supply, Assembling, Jointing, lowering lead free uPVC column pipes of nominal dia 65 mm, OD 75 mm (min), Non toxic, Pressure 10 Kg/Cm2 with and including Top and Bottom adaptor (SS) and accessories like EPDM ring and double SS stud all as spd and directed by Engineer-in-Charge. Make: Astral/Ashirwad/Ajay
Supply, installation / Lowering Submersible pump set, discharge capacity 180 LPM at not less than 140 Mtr Head, Electric driven, 415 V, TP, stainless steel body, water filled, fitted with Non return Valve to prevent back flow, with SWR of rating as per manufacturer (from MS flat iron clamp to submersible motor, length of SWR of size 6mm dia as per site requirement), including Submersible pump with connected in Column pipe up to not less than 140 RM depth for installation testing & Commissioning all as specified and directed by Engineer-in-Charge. Make: Crompton Greaves/ KSB/ Kirloskar brothers
Supply and fix Flat multi stranded copper cable 1100 volt grade of Submersible cabel of size 6 sqmm x 3 core, including secure for uPVC column pipe complete all as specified and directed. Make : Havells/ Polycab/ Finolex
S& lay 3- layer PP-R Polypropylene random copolymer) pipes of outer dia 63 mm SDR 6 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches.
S& lay 3- layer PP-R Polypropylene random copolymer) pipes of outer dia 32 mm SDR 6 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches.
S&F PP-R Ball valves (brass insert) of size 50 mm bore
S&F PP-R Ball valves (brass insert) of size 25 mm bore
Material and Labour for Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x6 mm as earthing lead burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to galvanised iron strip 32×6mm as earthing lead by means of bolts,nuts, check nuts and washer etc made of galvanised iron including 15 mm bore GI pipe medium grade up to 7.5 metres long all as shown in electrcial plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/ earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and as directed by Engr-in-charge. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any aditional in length shall be adjusted through deviation order. (ii) Item includes trhe cost of 7.5 metre GI earth lead. Any additional in length shall be measured and paid under respective item of this Schdule.
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated from RAL 7035 finish confirming to IP 65 complete including Cu bus bar 100 Amps, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry including PCC Foundation comprising of following:- (a) Incoming MCCB 63 Amps 4 pole with microprocessor based release having breaking capacity 25 KA - 01 Nos. (b) Ougoing MCB 40 Amp 4 Pole 10 KA, -02 Nos (c) Outgoing DOL starter 10 HP, Power Contactors, Control Relays - 02 Nos (d) Digital Voltmeter 0-500 V 96x96xmm …. 01 No. (e) Digital Ammeter 0 - 500 A 96x96mm …. 01 No. (f) Indicating lamps set RYB …. 01 set. (g) Panel mounted type digital multifunctional energy meter, CT operated, LT 3 phase, 4 wire, including CT ratio 60/5---01 Nos Make: CPRI approved, Channel partner of L&T/Schinder/Legrand/C&S
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade (Earthed ), of size 4 core 16 sq mm. all as specified and as directed by Engineer-in-charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply and lay 63 mm (OD) HDPE double corrugated (DWC) high density polythene pipes OF GRADE pe-63 having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 4984 for protection of UG cables. laid in trenches/road/drain or fixed along wall,poles or laid under floor all as spd and as directed by Engr-In-Charge. make-REX/POLY/Gemine (excavation and earth work shall be measured and paid separately)
Nitesh Enterprise
vijay infraprojects pvt ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .