Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAccepted-AOC HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹3.9 Cr Quoted ₹4.0 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹5.2 Cr+₹1.2 Cr (30.3%)Rejected-Finance 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹5.2 Cr+₹1.2 Cr (30.3%) | L2 | Rejected-Finance Being other than L1 |
| 3 | Rejected-Technical 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical Not Meeting the Eligibility Criteria as per NIT as two class below the eligible class |
Tender Value
₹4.3 Cr
EMD Value
₹5.1 L
Closing Date
22 Dec 2021, 6:00 pmClosed
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243 001
ADDN ALTN OF CERTAIN MD ACCN AT BHARUWALA PERRY ESTATE SURYA LINE JUNGLE AREA AND TCP LINE AT CLEMENT TOWN DEHRADUN
2021_MES_480590_1
CEBZ/DDN(H)/T-08 OF 2021-22
Open Tender
Civil Works
Item Rate
365 days
CLEMENT TOWN
AS PER TENDER DOCS
8 documents required · 8 mandatory
₹2,000
GE CLEMENT TOWN
₹5.1 L
Yes
7 Jan 2022
8 Oct 2021
23 Dec 2021
8 Oct 2021
22 Dec 2021
4 Dec 2021
9 Oct 2021 - 28 Oct 2021
Amount
BUILDING WORKS
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15 cm thickness ( below or above ground level ) and including removing unserviceable material,outside defence land complete all as specified and directed.
M & L 40mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) laid in panels as in flooring including finishing top surfaces even and smooth without using extra cement complete all as specified and directed
Supply only glass dividing strips 3mm thick 38mm wide complete all as specified and directed
M & L 75 mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection / hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement including filling the joints with mastic compound complete all as specified and directed
Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including on the roof top/mumty/parapet/RCC chajjas/RCC water tank and removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
M & L RCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, canopies, deck slabs or in Chajja / facia projection and the like complete all as specified and directed Note : The work is required to be carried out upto Second storey building. The cost of scaffolding shall be deemed to be included in the item. The contractor shall also make necessary safety arrangement for labour.
M & L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) ,complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each.Complete all as specified and directed
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each.Complete all as specified and directed.
M & L for PCC 1:3:6 type C1 (using 20mm graded aggregate stone aggregate) as in hold fast blocks including filling of pressed steel framing and complete all as specified and as directed.
M & L Solid (100 mm X 63 mm single rebate) factory made 100% solid WPC brown door frame made from 100% LEAD FREE (Single extruded process) material with density 780 kg / Cum & manufactured by an ISO: 9001-2015 certified company, all as per specification drawings as directed by the Engr-in-Charge. The door frame should be water proof, termite proof, fire retardant and having excellent screw holding capacity complete all as specified and directed. Make Rajshree Plastiwood, Kumar Arch TechPvt Ltd, Archid Ply, Floresta
M & L (125mm X 63mm Double Rebate) Factory made 100% solid WPC Door frame made from 100% LEAD FREE (Single extruded process) material with density 780kg / Cum & manufactured by an ISO: 9001-2015 certified company, all as per specification drawings as directed by the Engr-in-Charge. The door frame should be water proof, Termite proof, Fire retardant and having excellent screw holding capacity complete all as specified and directed. Make Rajshree Plastiwood, Kumar Arch TechPvt Ltd, Archid Ply, Floresta
S & F 0.90 mm thick decorative laminates surface finish one side,colour and pattern as approved,fixed with approved adhesive as per manufacture instructions complete all as specfied and as directed.
S & F 35 mm thick factory made flush shutter solid core construction with block board core and ply wood face panels, commercial type both sides complete all as specified and directed. Make Kit Ply wood / Century / Green Ply
S & F 30 mm thick 2nd class hard wood factory made glazed and skeleton shutter, open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats and complete all as specified and directed.
S & F galvanised mild steel wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specifed and directed.
M & L 30 MM thick moulded plain WPC solid door shutter: Providing (30mm thick) MOLDED WPC Brown factory made 100% solid door (Conforming As per IS: 4020) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/ Cum. Manufactured by an ISO: 9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity. complete all as specified and directed. Make Raj Shree Plasti wood / Sintex / Floresta / Kumar arch Tech Ltd
M & L 5.5mm thick sheet glass ordinary quality and fixed to wooden doors with wooden beads or tinned tacks in square not exc 0.5 sqm each pane complete all as specified and directed.
S & F three track Pre coated Steel Sliding Window System fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality, galvanized as per IS 277 with Zinc of 120 grams/ Sq. Mtr.) with total coated thickness of 0.58 mm or Powder Coated with pure Polyester Powder up to 50-60 microns thick. Windows Section for three track external frame should be of 44 x 107mm , Section for window glass shutter should be of 36 x 50 mm, if required Section for shutter horizontal mullion should be 22mm x 60mm, The windows should be paneled with 5mm thick Plain Float glass Gaskets are to be made with Ethyl Propylene Diamine Manomer (EPDM). Corner brackets for internal and external frame made of Polypropylene. Note:- The quoted rate for this Srl Item No 25 shall be deemed to be included the quoted for rate for Srl Item No 26.
Touch lock to be provided for window shuttes Sections are to be cut to length, joined and assembled by means of corner brackets. The above Frame should be fixed to brick/ concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames.Windows shall be provided with fixed Stainless steel 32gauge wire mesh/gauze of 304grade with 144 holes per square inch for mosquito proofing with the help of nut, bolt and flat iron of 20x3mm size on top and Grill made of 10mm MS Square bars welded to 25x4mm angle iron . Distance between bars should not be more than 125mm centre to centre. Total Grill and wire mess unit shall be powder coated.Assembling and installation of windows and ventilators shall be all as per details in manufacturer‟s instructions complete all as specified and directed. Make NCL, Ashwani Steel
S & F Pre coated Steel fixed type Window / ventilator fabricated from roll formed sections made of Galvanized Steel Colour Coated / Powder Coated (Base Steel as per IS 513 “D” quality, galvanized as per IS 277 with Zinc of 120 grams / Sq. Mtr.) with total coated thickness of 0.58 mm or Powder Coated with pure Polyester Powder up to 50-60 microns thick. The windows should be paneled with 5mm thick frosted glass Gaskets are to be made with Ethyl Propylene Diamine Manomer (EPDM). Corner brackets for internal and external frame made of Polypropylene. The above Frame should be fixed to brick / concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames. Windows shall be provided with Grill made of 10mm MS Square bars welded to 25x4mm angle iron . Distance between bars should not be more than 125mm centre to centre. Total Grill shall be powder coated.Assembling and installation of windows and ventilators shall be all as per details in manufacturer‟s instructions complete all as specified and directed. Make NCL, Ashwani Steel
S & F window / ventilator prepainted section of frame 72 x 55 mm fixed to wall or concrete surface with rawl plugs made of galvanised steel powder coated and section of shutter 47 x 20 mm, mulion section 72 x 50 mm (Base steel as per IS 513 "D" quality galvanized as per IS 277 with zinc of 120 gms / Sqm) glazed and wire gauge shutter prepared to receive wiremesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made made of 10mm square bars powder coated fixed to window frame with screws at 150mm c/c both ways, 4 mm thick sheet glass, 0.36 mm stainless steel wire cloth 1.4mm aperture and necessary fittings and all builders hardware such as handles, tower bolts & stays etc complete all as specified and as directed. Make NCL, Ashwani Steel
S & F for stainless steel barrel tower bolt (AISI 316 grade) of size 12 mm dia and 200 mm length Complete all as specified and directed. Make Hettich, Harrison, Dorset, Jaguar
S & F for stainlees steel sliding door bolt (AISI 316 grade) of size 16 mm dia and 250 mm long with hasp, staple (bolt type) complete all as specified and directed. Make Hettich, Harrison, Dorset, Jaguar
S & F stainless steel handle (AISI 316 grade) of size 150 mm complete all as specified and directed. Make Hettich, Harrison, Dorset, Jaguar
S & F for stainless steel barrel tower bolt (AISI 316 grade) of size 12 mm dia and 150 mm length Complete all as specified and directed. Make Hettich, Harrison, Dorset, Jaguar
S & F for Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm complete all as specified and directed.
S & F 150 mm , MS ordinary rat tail rod pattern springs including roller and plate , door spring fixed to door shutter complete all as specified and directed.
Dismantling Boarding any description fixed in any position with nails complete all as specified and directed.
S & F 18 mm thick with min density 600 Kg / Cum LEAD FREE PVC Celuka ply of both side plain white colour fixed with screws, solvent cement/ adhesive to make kitchen/bed rooms cabinet sides top and bottom and shelves inside the cabinets complete as per manufacturer’s specifications complete all as specified and directed. Make Raj Shree Plastic wood / Sintex / Archid Plywood / Kumar arch Tech Ltd
S & F 18 mm thick with min density 600 Kg / cum LEAD FREE PVC Celuka ply of single side rigid laminate of approved color and other side plain white colour fixed with ss screws and solvent cement/ adhesive to make kitchen cabinet shutters complete as per manufacturer’s instructions complete all as specified and directed. Make Raj Shree Plastic wood / Sintex / Archid Plywood / Kumar arch Tech Ltd
S & F 6 mm thick with min density 600 Kg / cum LEAD FREE PVC celuka ply fixed with ss screws and solvent cement / adhesive to make wall mount kitchen cabinet back sides complete as per manufacturer’s specifications complete all as specified and directed Make Raj Shree Plastic wood / Sintex / Archid Plywood / Kumar arch Tech Ltd
S & F in repairs for hasp and staples, size 150 mm, safety type, Stainless Steel Non Magnetic with hinge pin including bolt to hinge plate and fixed with screws, Complete all as specified and directed. Make Hettich, Harrison, Dorset, Jaguar
S & F Stainless steel kitchen plate rack 1.0 mm thick sheet of over all size 750 x 900 x 250 mm fixed with steel screws and steel rawal plugs Complete all as specified and directed. Make – Prayag, Blue star silver shine
S & F Auto closing hinges 35 mm of 0 crank ( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position all as specified and directed. Make Hettich, Kaff, Godrej & Kich
S & F Ball bearing runners 400 mm Telescopic (KA 5632) full extension load capacity 45 kgs complete all as specified and directed. Make Hettich, Kaff, Godrej & Kich
S & F D-type cabinet handles premium quality, stainless steel 304 / gloss chrome / SN finished 150 mm long matt finished complete fixed in position complete all as specified and directed. Make Hettich, Kaff, Godrej & Kich
S & F Ball catchers 304 grade stainless steel finished suitable for cabinets premium quality complete fixed in position as per manufacturer's instructions complete all as specified and directed. Make Hettich, Kaff, Godrej & Kich
S & F Stainless Steel 304 grade wire Basket of pull out type like lain / cup & saucer / bottle / multi purpose / 2-3 shelf baskets etc for kitchens of required sIze complete fixed in position all as specified and directed. Make Sleek Elnora / Godrej / Ever shine
S & F in repair for stainless steel, 25 mm dia and 1.2 mm thick curtain rod with and including fixing SS brackets and decorative type brass knobs both side of each rod , complete all as specified and directed. Note Measurement will be taken between end points of Knobs.
M & L for Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165. Complete all as specified and directed
S & F Welded steel wire fabric weight n exc 4 kg / sqm fixed to wood or steel members complete all as specified and directed
S & F Rolled mild steel work of Fe-290 (Gde E-165) as in framed work, trussed, purlins, crane gantries, railS&Fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M & L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa (AZ -150) as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. Make JSW (Colouron Plus), TATA (Bluescope).
Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material complete all as specified and directed. Note:- The work is required to be carried out at non-accessible roof for double storey .The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items
M & L 50 mm +/- 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed withliquid water proofing compound (as per manufacture direction and paid separately) over and incl one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete / mortar to old surface as per manufacturer direction and finishing the surface even and fair (without using extra cement) as in roof padding to receive roof treatment complete all as specified and directed.”complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M & L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3 .6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer. Note The quoted rate for Srl item No 53 above shall be deemed to be included the quoted rates for Srl item No 54.
(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg / Sqm each coat over APP membrance Note : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Roughening surfaces of old concrete floor by tucking, picking, sweeping clean and washing down with water to remove dust, etc. to receive the screed layer for laying floor tile. Complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed.
M & L for Non- skid coloured ceramic tiles of any design and pattern, 9 to 10 mm thick (square / rectangular) area of each tile exe 0.18 sqm but not exe 0.38, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption exc 0.5% but n.exc 3% and breaking strength 1000 N (Minimum) complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE.
M & L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square / rectangular) area of each tile exe 0.18 sqm but not exe 0.38, in vertical / skirting etc incl 10mm thick screed bed in CM 1:4, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption exc 0.5 % but n.exc 3 % and breaking strength 1000 N (minimum) Complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE.
M & L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square / rectangular) area of each tile exe 0.11 sqm but not exe 0.18 sqm, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II Complete all as specified and directed Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE.
M & L for joint free, Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square / rectangular) area of each tile exe 0.11 sqm but not exe 0.18, as in dado/skirting etc incl 10 mm thick rendering in CM 1:4 Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II Complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE.
M & L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square / rectangular) area of each tile exe 0.06 sqm but not exe 0.11 sqm, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II Grade-IV Complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE.
M & L for coloured glazed ceramic tiles of any design and pattern, 250 x 375 x 7 to 8 mm thick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III Complete all as specified and directed. Note: Shade of the tiles including Colour, design and pattern shall be got approved by GE .
All as per Srl item No.62 above but size of tiles 450 x 300 x 7 to 8 mm thick complete all as specified and directed.
M & L coloured vitrified tiles of any design and pattern, 600 x 600 x 9 to 10 mm thick as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles.Tiles shall be conforming to IS-15622:2017, Group B1b and including 15mm thick screed bed in Cement mortar (1:6) in flooring, set and jointed in neat cement slurry and pointed in cloured cement to match complete all as specified and directed directed by Engr-in-Charge . Note:- Shade of tiles including colour, design and pattern shall be approved by GE.
M & L coloured vitrified tiles of any design and pattern, 600 x 600 x 9 to 10 mm thick as in vertical surfaces / skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles.Tiles shall be conforming to IS-15622:2017,Group B1b and including 10mm thick rendering in Cement mortar (1:4), set and jointed in neat cement slurry and pointed in cloured cement to match complete all as specified and directed directed by Engr-in-Charge. Note:- Shade of tiles including colour,design and pattern shall be approved by GE.
M & L for 18 to 20 mm thick machine cut pre polished kota stone slab as in flooring / tread in full length in single piece without joint, of stair case over and incl 15 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing incl full round bull nosing including 40mm thick PCC in cement concrete (1:2:4) type-B1 as in floor complete all as specified and directed.
M & L for 18 to 20 mm thick machine cut pre polished kota stone slab as in riser of steps, full length in single piece without joint, of stair width / skirting laid over and incl 10 mm thick cement screed of CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade including necessary grinding, rubbing and polishing and bullnosing, including taking down cement plaster on brick or concrete surfaces complete all as specified and directed.
M & L for 16 to 18 mm thick prepolished marble any colour (Udaipur green marble) (table rubbed and polished) as in stair case (tread & riser in single piece) steps, jambs, pillars, window cills, cooking platforms including pointing in white cement (1:2) using marble dust to match with marble shade over and including cement screed bed 15mm thick in CM (1:6) complete all as specified and directed
M & L for rubber moulded vibro compacted coloured glossy finish cement concrete chequered tiles of size 30cm x 30cm x 20mm thick jointed in neat cement slurry and pointed in white or coloured cement and pigment to match the surface of tile as in floor over and including 15mm thick screed bed in CM 1:6 and 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) complete all as specified and directed.
M & L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in levelling course finished to receive the top layer of floor complete all as specified and directed
M & L 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material outside of A 1 defence land complete all as specified and directed.
M & L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & smooth without using extra cement. Complete all as specified and directed.
M & L plastering in two layers consisting of 10mm thick in CM 1:6 and top layer of 5mm thick in CM 1:4 mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. (WPC shall be measured and paid seperately)
M & L rendering 5 mm thick in CM 1:3 in ceiling / Chhajja's finished even and smooth (without using extra cement). Complete all as specified and directed
M & L butt hinges of mild steel medium weight cold rolled (ISI marked) 100mm long and fixed with screws to timber frame work Complete all as specified and directed
M & L for preparation of new surface plastered or unplastered and applying three coat of white wash on ceiling all as specified and as directed by Engr-in-Charge.
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . Note The quoted rate for Srl item No 78 shall be deemed to be included the quoted rates for Srl item No 79.
(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmaste of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. Note The quoted rate for Srl item No 80 shall be deemed to be included the quoted rates for Srl item No 81.
(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M & L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller over 2 mm thick wall care putty all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge . Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. Note The quoted rate for Srl item No 82 shall be deemed to be included the quoted rates for Srl item No 83.
(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE
M & L Preparation old treated surfaces of walls and applying one coat of white wash complete all as specified and directed.
M & L Preparation old treated surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M & L for prepairing old painted steel and Iron surfaces of any description over 10 cm Width / Girth and applying one coat of synthetic enamel paint of any tint complete all as specified and directed.
M & L for Polishing: Prepare a solution of shellac in de-natured spirit together with alcohol ingredient as may be necessary. The shellac shall be 25 percent by weight of de-natured spirit. Shellac crystals shall be washed in luke warm water to remove dust etc and clearly dried before use. Shake the mixture until the ingredients are completely dissolved. Strain the section through coarse muslin. Take a wad of cotton/wool and partially saturate it with the mixture thus prepared. Enclose the wad in a piece of linen cloth and apply to the surface along the grain with light even pressure. If the wad shows signs of sticking, it should be slightly dipped in mustard oil. Continue rubbing until a thinly coated glass appearance is obtained. Set aside for about two hours to permit surface coat to harden. Rub surface with sand paper no to remove any coarse grains. Repeat polishing the surface as before when a clean grained smooth surface is obtained. It should be allowed to harden for about an hour. Rub surface again with no o sand paper. Change the wad as before and apply to the surface in circular motion until the whole surface is covered. Once over change the wad with mentholated spirit and apply with straight stroke in direction of the grain until the required glossy finish is obtained to the satisfaction of the Engr-in-Charge. complete all as specified and directed.
M & L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (weather coat anti dust of Berger paint or equitant in Asian paint, Nerolac etc having five years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of point and as directed at site by Engineer-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. Note The quoted rate for Srl item No 88 shall be deemed to be included the quoted rates for Srl item No 89.
(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material, from wall/ chhajja including all loose dust particle from brick and application of two coat of smart care damp block 2k slurry by brush or roller on brick surface (second coat shall be applied after 4-6 hrs of 1st coat) to achieve a coverage of 0.72kg/sqm/coat and M&L for 15mm thick cement plaster in CM 1:4 after preparation of surfaces complete all as specified and as directed.
M & L for preparation of new steel surfaces of any description over 10cm width & girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer. Complete all as specified and directed
M & L for Preparation of New wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint (any tint) over a coat of pink primer. Complete all as specified and directed
M & L PCC 1:7:12 type F-2, using 40 mm graded concrete, as in foundation, mass concreting, sunken floor etc complete all as specified and directed
M & L PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate, as in padding, sunken, coping portion rounded chamfered on edge complete all as specified and directed.
M & L 10 mm thick rendering in cement mortar (1:4) mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid seperately.
Supply only integral liquid water proofing compound complete all as specified and directed. Make – LW of Dr Fixit / Cico Super of SIKA / WL of Fosroc.
M & L for two coats of elastomeric compound i.e. super latex of Dr. Fixit on concrete surfcae after cleaning of sunken portion (vertical or Horizontal) by removing all the loose mortar, laitance dirt, dust etc by chiesal, hammer, wirebrush, jute brush and air blower complete all as specified and directed
Supply and Fixing 40 mm dia GI light grade pipe as in spout of sunken slab complete all as specified and directed.
Disconnecting existing tanks of capacity exc 500 Ltr but n. exc 1000 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia .Complete all as specified and directed
S & F for GI tubing 15mm bore, ISI marked medium grade with all fittings of medium grade (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed. Note:- Cutting chases in wall shall be measured and paid seperately.
M & L for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .Complete all as specified and directed.
S & F for GI tubing 20mm bore, medium grade with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs,unions etc.) including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete . complete all as specified and directed. Note:- Cutting chases in wall shall be measured and paid seperately.
Fixing only 20 mm dia bore GI tubing medium grade fixed to wall or ceiling or laid in floors etc complete all as specified and directed
S & F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes (6 Kg / Sqcm pressure rating) (single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes (6 Kg / Sqcm pressure rating) (single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes , single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes , single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S & F in repair 75 mm dia PVC (SWR) multi floor trap, with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed
S & F in repair PVC (SWR) junction single, (Single T) equal or unequal 110 mm bore with access door complete all as specified and directed.
S & F in repair PVC (SWR) junction single, (Single T) equal or unequal 75mm bore with access door complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bend of any radius complete all as specified and directed.
S & F in repair PVC (SWR) bend any radius 110 mm bore with access door complete all as specified and directed.
S & F in repair PVC (SWR) bend any radius 75 mm bore with access door complete all as specified and directed.
S & F in repair PVC (SWR) 'P' Traps 110mm bore.complete all as specified and directed.
S & F in repair PVC vent cowls 75mm. complete all as specified and directed.
S & F in repair for PVC Connections 15mm size with PTMT nuts of length 450 mm (ISI Marked). Complete all as specified and directed
S & F in repair PVC waste pipe 32 / 40 mm dia and length of pipe 750 mm medium grade with coupling complete all as specified and directed
S & F cast copper alloy, chromium plated Towel Rail 20 mm dia, D-type, 600 mm long fixed with and including Chromimum plated brass screws and wooden plastic cleats Complete all as specified and directed . Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site .
S & F in repair bib tap cast copper alloy with crutch or butter fly handle, screwed down for iron pipe 15 mm bore of tubing fancy type cromium plated. complete all as specified and directed. (Note- Chromium plated fitting shall be brought in store yard first as approved by and will be issued subsequently for fixing at site . Make:- Jaquar Cat Part No 107KN, Marc Cat Part No MVT2080 and Hindware – F-100011QT
S & F in repairs stop valve cast copper alloy screwed down high presure (concealed type) screwed both end for iron pipe 15 mm dia fancy type cromium plated. complete all as specified and directed. Make JaquarEssco Cat Par No -MQT-526KN or equvalent in Part No. 12260 (Gem), F110004 (Hindware) Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site
M & L MS Work confirming to Fe-290 Gde E-165 as in Bands strapes stays hold fast and similar small articles complete all as specified and directed.
S & F in repair CP shower rose with or without swivel joints of 125 mm size with shower arm complete all as specified and directed Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site .
M & L16 to 18 mm thick MDF, DWR partical board, exterior grade prelaminated one side with decorative choice lamination and other side plain white lamination fixed with screws to timber frame work incl beading/ lamination to match with exposed surface complete all as specified and directed.
S & F in repair of sinks made of stainless steel 1.0 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm and bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S & F in repair corner self 300mm radius of 10mm thick toughened glass with CP railing with bracket S & Fixed with brass screw complete all as specified and directed . Make Jaquar Cat Part No ACN-1173, Parryware T-6010A-1, Cera- F-5005103
S & F in repair vitreous china squatting pan ‘Orissa pattern’ size 580 x 440 mm white with integral foot rest including connection to trap, and flushing pipe, anti-syphonage pipe, etc and including lime concrete bedding complete all as specified and directed.
S & F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ), low level , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make Complete all as specified and directed.
S & F in repair vitreous china WHB size 505 x 410 x 185 mm with pedestal white with flat back including CP waste coupling and PVC waste pipe complete all as specified and directed Make - Jaquar Cat Part No AIS-WHT-101801, Hindware Cat Part No -11032
S & F vitreous china wash down water closed pan (Pedestal pattern) white, including connection to drain (or out going pipe) and to flush pipe, antisypthonic (excluding flushing cistern and flush pipe) complete all as specified and directed .
Supply & fix in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15 mm bore pipes complete all as specified and directed . Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site . Make Jaquar Cat Part No 273KNUPR, Hindware – F20018 & Parryware – T-9940A
S & F in repair 15mm dia brass CP sink mixer with swinging spout (wall mounted model) with connecting legs and wall flanges screwed down for iron pipe and fixed complete all as specified and directed . Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site . Make Jaquar / Hindware / CERA
S & F in repair 15mm dia chromium plated central hole wash hand basin mixer without PWS with 450mm BRAIDED HOUSE hose screwed down high pressure screwed for iron pipe completed all as specified and directed . Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site . Make Jaquar Cat Part No ARI39001B, Hindware – F280010SCD, Cera- F-2013451
S & F in repair CP health faucet with 1m flexible tube and wall hook complete all as specified and directed. Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site . Make Jaquar Cat Part No ALD-573, Hindware Cat Part No – 160027, Parryware - T-99408
S & F in repairs angle stop valve cast copper alloy screwed down high presure screwed both end for iron pipe 15 mm dia fancy type cromium plated. complete all as specified and directed. Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site . Make Jaquar Cat Part No CON-053KN, Hindware Cat Part No – F-320006, Parryware - G-4907A1
S & F in repair brass CP bib tap 15mm bore fancy type screwed for iron pipe complete with wall flange complete all as specified and directed. Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site . Make Jaquar Cat Part No FUS29037, Parryware- G-2304A1, Cera – F1014151
S & F in repair CP overhead shower 125 mm round shape single flow (ABS body chromium plated with gray face plate) with rubit cleaning system fixed in 15mm bore of pipe complete all as specified and directed . Note- Chromium plated fitting shall be brought in store yard first as approved by GE and will be issued subsequently for fixing at site . Make Jaquar Cat Part No OHS 1989, Hindware Cat Part No – F-16004, Parryware - T-9927A
S & F in repair CP toilet paper holder fixed to wall with CP brass screws complete all as specified and directed. Make Jaquar Cat Part No AKP-35751, Hindware Cat Part No – F-880003, Parryware-T-6514A1
S & F for Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long Complete all as specified and directed Make Jaquar Cat Part No ACN-1171N, Cera Cat Part No – F-5005301, Parryware - T-6009A-1
S & F in repairs PVC water storage tank Double layer (ISI marked) cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 500 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed
S & F in repairs PVC water storage tank Double layer (ISI marked) white colour cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 1000 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 25mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed
Disconnecting existing tanks of capacity exc 250 Ltr but n. exc 500 Ltr, etting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position complete all as specified and directed
S & F in repair 15 mm dia Gun Metal, globe or Gate Valve (ISI marked) class 150 with Iron wheel head Screwed both ends for Iron Pipe and Complete all as specified and directed
S & F in repair 20 mm dia Gun Metal, globe or Gate Valve (ISI marked) class 150 with Iron wheel head Screwed both ends for Iron Pipe and Complete all as specified and directed
M & L for post construction Antitermite treatment Along the wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
M & L 16 to 18 mm thick pre polished granite stone slab of approved quality on cooking platform over and incl 20mm thick cement mortar in 1:6, bedded and jointed with cement mortar and pointed in white cement mortar 1:2 complete all as specified and directed.
M & L for at points of contact of wood work by chemical emulsion (in oil or kerosine based solution) at the rate of 0.5 lts per hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm C/C and sealing the same complete all as specified and directed.
Dismantling and taking down carefully unservicable copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall / floor etc, to match with the existing surfaces of wall / floor complete all as specified & directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Taking down submain / service / UG cable on wall / trenches / roof / floor etc complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall / floor etc. complete all as specified and directed.
M & L Point wiring with 1.5 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor in and including concealed rigid PVC conduit medium grade of size not less than 20 mm dia including accessories incl cutting chases , making surface good etc along with contineous earth wire 1.5 Sqmm FRLSH PVC insulated , unsheathed stranded copper conductor cable and connected to common earth dolly including metal flush box with white cover plate & frame for modular switch & socket complete with all accessories for complete all as specified & directed for the following:- Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. (a) One light / fan / bell / exhaust fan point controlled by one, 01-way modular type switch 5/6 Amp.
All as per Srl Item No 152 above but one socket outlet on the same board with other switches / sockets
All as per Srl Item No 152 above but for One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, 01-way modular type switch single pole 5/6 Amps.
All as per Srl Item No 152 above but one light point controlled by two, 02-way point wiring with two no of two way switch with cables 1.5 sqmm size in PVC conduit
M & L Point wiring with 2.5 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor in and including concealed rigid PVC conduit medium grade of size not less than 20 mm dia including accessories incl cutting chases and making surface good etc along with contineous earth wire 2.5Sqmm FRLSH PVC insulated , unsheathed stranded copper conductor cable and connected to common earth dolly, including metal flush box with white cover plate & frame for modular switch & socket complete with all accessories for Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will the final and binding. (a) one three pin 15 Amps Switch Socket outlet on independent board
All as per Srl item No 156 above but with 4 Sqmm PVC insulated FRLSH cable for 15 Amps power point.
M & L Point wiring with 1.5 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor drawn in Existing concealed PVC conduit, along with contineous earth wire 1.5 Sqmm FRLSH PVC insulated , unsheathed stranded copper conductor cable and connected to common earth dolly including metal flush box with white cover plate & frame for modular switch & socket complete all as specified & directed for the following :- (a) One light / fan / bell / exhaust fan point controlled by one, 01-way modular type switch 06 Amp.
All as per Srl Item No 158 above but one socket outlet on the same board with other switches/sockets
All as per Item No 158 above but for One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, 01-way modular type switch single pole 5/6 Amps.
M & L Point wiring with 2.5 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor drawn in Existing concealed PVC conduit, along with contineous earth wire 2.5Sqmm FRLSH PVC insulated , unsheathed stranded copper conductor cable and connected to common earth dolly, including metal flush box with white cover plate & frame for modular switch & socket complete with all accessories for complete all as specified and directed. (a) one three pin 15 Amps Switch Socket outlet on independent board
All as per item No 161 above but with 4 Sqmm PVC insulated FRLSH cable for 15 Amps power point.
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
Supply and fixing modular switch type 1 way 06 Amp, 1 Module, 240 Volts AC complete all as specified and directed. Make Legrand Cat No-673401, Indo Asian Cat No-800000 Cona Cat No-9251
Supply and fixing modular switch type 1 way 16 Amp, 1 Module, 240 Volts AC complete all as specified and directed. Make Legrand Cat No-673411, Indo Asian Cat No-800002 Cona Cat No-9386
Supply and fixing modular bell push 1 way 06 Amp, 1 Module type all as specified complete all as specified and directed. Make Legrand Cat No-673404, Indo Asian Cat No-800007 Cona Cat No-9261
Supply and fixing modular switch type 2 way 06 Amp, 1 Module, 240 Volts AC complete all as specified and directed. Make Legrand Cat No-673402, Indo Asian Cat No-800001 Cona Cat No-9256
Supply and fixing modular socket 06 Amp 3 pin combined, 2 module complete all as specified and directed. Make Legrand Cat No-673452, Indo Asian Cat No-800020 Cona Cat No-9316
Supply and fixing modular socket 06/16 Amp combined, 2 module complete all as specified and directed. Make Legrand Cat No-673455, Indo Asian Cat No-800022 Cona Cat No-9416
S&F bell ding dong elelctric 230V AC single pole complete all as specified and directed. Make Anchor / Havells / Cona
Supply and fixing modular fan regulator, 120 W, 2 module complete all as specified and directed. Make Legrand Cat No-673430, Indo Asian Cat No-800043 Cona Cat No-9381
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
M & L for taking down and refixing at same position of Geyser after tiling work complete all as specified and directed.
S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed
Supply and fixing batton holder mounted on wall including 09 Watt LED Bulb complete all as specified and directed.
Taking down old ceiling fan from existing building and deposit to MES Store. complete all as specified and directed.
Taking down ceiling fan including servicing and greasing from existing building again refixing the same ceiling fan connecting up including provision of cable flexible 3 core of suitable size wire from ceiling rose to connect fan. complete all as specified and directed.
Supply and fix surface mounted LED luminiare, 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10% made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency > 120 lumen per watt, internally pre –wired through flexible wire connecting with ceiling rose all as directed. Make (i) Havells Cat No-LUMILINEPLUSBS20WLED865SPCSS (ii) Crompton Cat No- LCTLN-20-CDL (iii) Shakti Cat No-SZSLBMX020 Note : The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period.
S& F in repair oval shape Bulk head Edge-lit LED fitting comprising with high brightness LED 10 watt, IP-67 protection complete all as specified and directed. Make (i) Havells Cat No-HEXAFT10WLED857SSYMBOPC (ii) Crompton Cat No-LBHE10-CDL (iii) Shakti-SZSLMMX010
Supply and Fixing Glaze Wall Light including 9/10 watt LED lamp ( B22), 6500 K complete all as specified and as directed. Make Havells / Crompton / Shakti
Supply and fixing LED lights fitting mirror type with high out put diffuser 2 feet, 10 watt 220V, AC decorative type with driver, holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Make (i) Havells Cat No- LUMILINEPLUSBS10WLED865SPCSS (ii) Crompton Cat No-LCTLN-10-CDL (iii) Shakti Cat No- SZSLBMX010
Supply and fix LED street/security light fitting 20W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts AC, 50 HZ, consisting of reflective lens wired with approximate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level > 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency > 120 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 K- 6500 K including fixed on wall with 02 Nos MS clamp made out of 40 x 6 mm F1 and bracket made out of 32 mm dia light grade GI pipe not less than 0.9 mtr long bend to shape including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volta grade all as specified and as directed by Engr-in-Charge Note :- (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 & LM 80 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRS (iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above. Make (i) Havells Cat No- ENURAPEARLSL20WLED757SASTOPCMP (ii) Crompton Cat No- LSTS-20-CDL-M (iii) Shakti Cat No-SZPSLMM020
S & F double door sheet metal enclosure for DB , 08 way , SPN, with 200 Amps rated bus bar , 240 Volts suitable for housing MCBs and flushed inside the wall and making good for disturbed surface with existing etc complete all as specified & directed.
S & F double door sheet metal enclosure for DB , 12 way , SPN, with 200 Amps rated bus bar , 240 Volts suitable for housing MCBs and flushed inside the wall and making good for disturbed surface with existing etc complete all as specified & directed.
Supply and fix sheet metal enclosures with metal socket and plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with One RCCB double pole 25 Amp, 30 mili Amps all complete as specified and directed by Engineer-in-Charge .
Supply and fixing MCB SP AC 240 volts of 6 to 32 Amps capacity 10 KA, 'B' series and making connections with suitable size of copper lugs complete all as specified and directed .
Supply and fixing MCB SPN 40 Amp 240 V AC 10 KA repturing capacity complete all as specified and directed.
Supply and fix electric water heater storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve thermostate NRV connection piece including taking down old water heater storage type from existing building and deposit to MES Store including all as specified and directed.
S&F Exhaust fan AC single phase 230/240 Volt of size 300 mm sweep, metallic body powder coated painted finish, Power consumption- 50 W, Air deplacement -1290 Cum/Hr, RPM-900 complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed sufaces of wall complete including taking down old exhuast fan any type from existing building and deposit to MES Store all as specified and directed.
Supply & fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm sweep complete with all fittings all as specified.
Supply, installing, testing and commissioning factory made 2 mm thick and tested LT Panel Indoor type Wall mounted, of size : 900 X 650 X 250 mm suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 200 Amps rating installed on DMC insulators with bus bar chamber. front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:- Note Quoted rate for this Srl item No 201 shall include the quoted rate for Srl item No 202 & 203 also.
BUS BAR CHAMBER:- (a) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. (i) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three). INCOMING SUPPLY:- (i) MCCB 125 Amps 25 KA , 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz =01 No., Make of MCCB:-L&T/Siemens / Legrand/ Schneider OUTGOING SUPPLY:- (i) MCB SPN 40 Amps, 230 volts, 50Hz, rupturing capacity 10 KA = 5 Nos., Make of MCB:- L&T/ Siemens/ Legrand/ Schneider. (ii) Space for Fixing of 1 Phase, 2 Wire, Pre-paid Energy Meters- 05 Nos (iii) DMC Connector 2 way 100 A for outgoing submain supply - 5 Nos. Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible.
Notes For Item No 202 Contd.....:- 1. The panel manufacturer should have following certification:- (i) CPRI certificate Degree of protection IP-54 (should have IEC: 61439-1-2 & IEC: 60529 tests) (ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certificate rated current not less than 5000A 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from GE Clement Town before fabrication. 4. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
Supply, installing, testing and commissioning factory made 2 mm thick and tested LT Panel Indoor type Wall mounted, of size : 1500 X 1200 X 250 mm suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 200 Amps rating installed on DMC insulators with bus bar chamber. front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS-H cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:- Note Quoted rate for this Srl item No 204 shall include the quoted rate for item No 205 & 206 also.
BUS BAR CHAMBER:- (a) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. (i) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three). INCOMING SUPPLY:- (i) MCCB 160 Amps 25 KA , 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz =01 No., Make of MCCB:-L&T/Siemens / Legrand/ Schneider OUTGOING SUPPLY:- (i) MCB SPN 40 Amps, 230 volts, 50Hz, rupturing capacity 10 KA = 09 Nos., Make of MCB:- L&T/ Siemens/ Legrand/ Schneider. (ii) Space for Fixing of 1 Phase, 2 Wire, Pre-paid Energy Meters- 09 Nos (iii) DMC Connector 2 way 100 A for outgoing submain supply - 9 Nos. Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible.
Notes For Item No 205 Contd.....:- 1. The panel manufacturer should have following certification:- (i) CPRI certificate Degree of protection IP-54 (should have IEC: 61439-1-2 & IEC: 60529 tests) (ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certificate rated current not less than 5000A 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from GE Clement Town before fabrication. 4. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
M & L for sub main wiring with two run of 6 Sqmm (nominal cross sectional area ) of single core unsheathed PVC insulated cables FRLS-H cable 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 20 mm or higher dia with & including necessary conduit accessories concealed / surface only on roof & column) type including 6 Sqmm stranded copper conductor PVC insulated cable as earth wire connected to common earth dolly complete all as specified & directed. Note : (i) Two runs of phsse and neutral wire and one run earth wire with PVC conduit measured as one length or one RM . (ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sqmm 3.5 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement all as specified and directed. by Engr-in-charge. Note:(i) GI tubing required shall be measured and paid separately under relevant item of sch as supply only, (ii) Heat shrink sleeve of 25mm long on HS joint for colour indication shall deemed to be included on the quoted rate.
Excavation in trenches for taking out/laying of cable and pipe line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in soft/loose soil. complete all as specified and directed.
Returning, filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in each layer in soft / lose soil.complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point. complete all as specified and directed.
M & L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable (measurement to be taken after punning down consolidated thickness). complete all as specified and directed.
Supply and laying , un-reinforced precast concrete cable cover (ISI marked) ,class LV,Type I,flat,size 250mm X 150mm X 40mm with breaking load capacity 200 KG complete all as specified and directed.
Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road etc. for cable protection complete all as specified and directed .
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00, BEE Five star rated with brushless direct current motor (BLDC) including provision of cable flexible 3 core of suitable size wire from ceiling rose to Ceiling Fan complete all as specified and directed.
Taking down carefully by disconnecting and unscrewing from board / out lets boxes, electric meters of any locatios and deposited to MES store yard complete all as specified and directed.
Supply, installation, testing & commissioning of 1 Phase, 2 Wire, Pre-paid Energy Meters, BIS 15884 Marked in existing Meter Board / Floor Panels with Pre Payment capacitive touch Key pad based Digital having current range 10-60 Amp, 240V, acucuracy class 1.0 along with Parallel home display split Unit, with inbuilt load control switch, containing provision for TOD & RTC, dynamic load allocation facility from Grid and DG, capable to define 4 tariff slabs, happy hour & holiday definition including 6 core control cable laying to connect meter to Parallel Home Display Unit for remote access of data / operation form home Along with both side Connector punching drawn in medium class PVC conduit 25 mm / Casing & capping size (20mm* 12mm) along with accessories in surface / recess including cutting in the wall and making good the same in case of recess all as specified and directed. Make L&T / Siemens / Schneider
BLANK
Material & labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected by GI wire 4 mm dia as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300 mm x 300 mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320 x 80 mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1 (2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4 kg / sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Note : Tenderers may note that amount of credit Rs 6,94,987.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
J.D.Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .