| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹46.0 L+₹3.0 L (7.04%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹48.1 L+₹5.2 L (12.0%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹53.3 L+₹10.4 L (24.1%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹54.5 L
EMD Value
₹1.1 L
Closing Date
12 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF AMBALA
HQ CWE AF Ambala Ambala cantt
PROVISION OF EXTERNAL SERVICES FOR TECHNICAL BLDG AT AF STATION AMBALA UNDER GE (AF) AMBALA
2022_MES_512340_1
CWE/AF AMB/AMB-54/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Ambala cantt
For MES enlisted contractor Class C Category b ii and for un-enlisted contractor refer NIT
7 documents required · 7 mandatory
₹1,000
GE AF AMBALA
₹1.1 L
Yes
5 May 2022
7 Mar 2022
14 Apr 2022
7 Mar 2022
12 Apr 2022
29 Mar 2022
7 Mar 2022 - 22 Mar 2022
60 days
Amount
Supply, installation, commissioning and testing of HT 11KV, 3 phase 50 hertz, indoor type, floor mounted, horizontal drawout, vertical isolation type totally enclosed metal switchgear complete vaccum circuit breaker of capacity 400 Amp as outgoing with motor operated, spring charged having rupturing capacity of 250 MVA & breaking capacity 13.1 KA with over load & earth fault protection, 230 volts, AC Single phase 80watt rated strip type heater with thermostat with indicator complete- 02 Nos., current transformer (CT chamber incorporating 3 single phase resin cast dual class, dual ratio CTs of ratio 200/100/5 Amps with suitable VA burden and accuracy class - 01 No., provision of PTs for measurement of voltage, rear cable termination provision for terminating 3 core upto 120sqmm XLPE cable, digital amperemeter, digital voltmeter, 2X12volt DC battery with provision of battery charger, Triple pole digital numerical relay for over current setting 50% to 200% and one high set element for earth fault protection setting 20% to 80%, On/Off/Trip indicator - 01 No., TNC switch - 01 No., Trip circuit healthy indication lamp with push button - 01 No., 3 phase RYB indication with lamp & holder - 01 set, cable glands of suitable size, in built integral earthing including connection with extending the copper busbars for coupling with existing VCBs complete with standard fittings including testing on completion at site complete all as specified & directed.
Notes:- (i) Rate of cutting in existing VCB, modification of existing busbar for matching with new busbar will be included in the quoted rates. (ii) The drawings in respect of VCB shall be approved by Accepting Officer through GE and as & when requested by contractor before placing order to manufacturer (iii) VCB shall be tested by representative of Accepting Officer at factory premises before dispatch as & when requested by contractor. (iv) The testing and commissing of the VCB shall be carried out in presence of Electrical Inspector as & when requested by contractor.
Supply, laying, jointing, testing and commissioning HT XLPE cable (heavy duty), 11000 volts (earthed), cross sectional area 120 Sqmm, 3 core, insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, laid in trenches /pipes /ducts /along poles/ walls/ equipment etc complete all as specified & directed. Notes: (i) Cable shall be of manufacturing date not earlier than Dec 2021. All the cable shall be embossed with year of manufacturing, meterage at every metre, in addition to its own standard markings as per IS i.e. Size, voltage etc. (ii) Excavation & earth work, sand cushioning, end termination joints, protection pipes & protection covers shall be measured and paid separately. (iii) No straight through joint shall be permitted in less than single drum length. (iv) The contractor shall produce original purchase vouchers duly machine numbered alongwith excise duty gate pass of factory for verification and record. (v) Cable shall be tested in the presence of rep of Accepting Officer at the factory premises as well as after laying in the trenches & before returning filling in the trenches as & when requested by contractor.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for walls, shafts, manholes, poles not exceeding 10 sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as specified & directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose soil complete all as specified & directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
M&L Sand cushioning with fine dry sand to cable with a layer of sand 8 cm thick before laying the cable and 15 cm thick after laying the cable (punned down to 18 cm thick after laying and stretching of cable) complete all as specified & directed.
M&L un-reinforced precast concrete cable cover, Class HV type-1, flat, size 300mm x 180mm x 40mm, laid flat for protection of cable, adjacent to each other, perpendicular to central axis of cable complete all as specified & directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead wire 4 mm dia upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20 mm bore including protection pipe GI light grade 15mm bore, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in soft/losse soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C-1(using 20 mm graded mechnically crushed stone aggregates) and pit cover slab shall be of RCC 1:2:4 type B-1 (using 20 mm graded mechnically crushed stone aggregates) reinforced with 8mm dia deformed bars @ 15cm centre to centre both ways including necessary form work and earthwork in soft/losse soil complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes:- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at no extra cost , till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
M&L Air break switch, gang operated, triple pole, HT, 11000 volt, 200Amp rating, outdoor type confirming to IS specification for horizontal or vertical operation, mechanically operated, mounted on 12 insulators and steel frame with operating mechanism & operating rod of 25mm bore, heavy duty GI pipe from operating level with locking arrangements including making electrical connections to make it functional after testing complete all as specified & directed.
M&L lightning arresters expulsion type (set of three) complete with all fittings, transmission class, discharge capacity 65 kilo amp, 11000 volts complete all as specified & directed.
M&L cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed duly painted with two coats of aluminium paint over & including one coat of red oxide primer complete all as specified & directed.
M&L anti climbing device, spikes type fabricated out of MS bars ,round square and flat with and including providing required nuts ,bolts,washers etc., welding in two halves, made to shape, to suit the cross section of the pole duly painted with two coats of aluminium paint over & including one coat of red oxide complete all as specified & directed.
M&L true vertical steel tubular, swaged welded pole conforming to IS-2713 part II , type 410 SP-55, 11 metre long complete with mild steel base plate of 6 mm thick of size 300mm X 300mm, finial taper plug, cap, bolts, nuts, washer and screws hole of required size and Nos. for fixing cross arms including painting externally with two coats of aluminium paint over & including one coat of red oxide primer for exposed surface and two coats of black bituminious paint for embeded portion in concrete as well as throughout internally including provision of white & blue colour strips with fluorescent paint upto 1.5 mtr height & nubmering of pole complete all as specified & directed. Note:- Excavation, earth work and PCC shall be measured and paid separately.
Excavation in trenches not exceeding 1.5mtr wide and exceeding 1.5mtr but not exceeding 3.0mtr in depth for foundation etc or for walls, shafts, manholes, poles not exceeding 10 sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as specified & directed.
M&L plain cement concrete(PCC) 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates as in foundations, filling and mass concrete etc complete all as specified & directed.
M&L plain cement concrete(PCC) 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates as in coping to pole etc. including necessary formwork to exposed surface finished even & smooth complete all as specified & directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead strip 32 mm x 6 mm upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20 mm bore including protection pipe light grade GI 40mm bore, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in soft/losse soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C-1(using 20 mm graded mechnically crushed stone aggregates) and pit cover slab shall be of RCC 1:2:4 type B-1 (using 20 mm graded mechnically crushed stone aggregates) reinforced with 8mm dia deformed bars @ 15cm centre to centre both ways including necessary form work and earthwork in soft/losse soil complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes:- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at no extra cost , till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
S&F cable jointing kit for 11000 volt earthed grade, outdoor, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm complete all as specified & directed.
S&F cable jointing kit for 11000 volt earthed grade, indoor, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm complete all as specified & directed.
Supply & laying synthetic rubber insulated mat, size 2mtr x 1mtr, 25mm thick for voltage upto 11KV for electrical purpose as per IS 15652-2006(superseding IS 5424) suitable for electrical shock safety complete all as specified & directed.
Dismantling of concrete poles, any size complete all as specified & directed.
Dismantling of stay assembly complete all as specified & directed.
S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed.
M&L GI pipe 80 mm bore, light grade confirming to IS 1239, in any length with all fittings laid in trenches, under road, under floor, fixed to wall with fixing arrangement or along the pole with fixing arrangement etc for cable protection complete all as specified & directed .
M&L for making bore under roads / paths / hardstanding concrete/taxi track bituminious etc. of any length at any location for insertion of GI protection pipe upto 100mm bore to pass the HT/LT cables in soft /losse soil with complete arrangement of T&P including making good the disturbed surface after laying of pipe complete all as specified and directed. Note: GI pipe shall be measured and paid seprately.
M&L cutting of existing 150mm bore cast iron pipes and reducing to required length in position for insertion of new tees, branches, etc before laying complete all as specified & directed.
M&L galvanized iron steel water tubing 50 mm bore, medium grade, with all fittings(such as elbow, unions, nipples, tees, bends, short pieces, connectors, back nuts, caps, plugs, diminishing pieces, sockets etc. as per site requirteement) laid in trenches complete all as specified & directed.
Description all as per BOQ item No 27.00 here-in-before but steel water tubing 40mm bore.
Description all as per BOQ item No 27.00 here-in-before but steel water tubing 25mm bore. Note for BOQ item No. 27.00 to 29.00 : Excavation & earthwork shall be measured & paid separately.
S&F 50mm bore heavy duty gun-metal, gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked complete all as specified & directed.
Description all as per BOQ item No 30.00 here-in-before but 25mm bore.
S&F 40mm bore GI union brass, both ends screwed to iron pipes, or one flange end bedded in red lead cement, and other end screwed to iron pipe, etc. complete all as specified and directed.
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted in total quoted amount of BOQ to arrive contract sum.
R D Bansal
Raman Electric Trading Co
M/S Sonu Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .