Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC TCP BAZAR JOSHIMATH DIST CHAMOLI UK PIN 246443 | JOSHIMATH | CHAMOLI | UK | 246443 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.3 L+₹36,390.50 (1.92%)Rejected-AOC JHABRERA ROAD NEAR POWER STATION MANGLOR DISTT HARIDWAR UTTRAKHAND | MANGLOR | HARIDWAR | UTTARAKHAND | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹20.7 L+₹1.8 L (9.31%)Rejected-AOC | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹20.9 L+₹1.9 L (10.1%)Rejected-AOC OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L4 | Rejected-AOC Not lowest | |
| 5 | L5₹21.6 L+₹2.6 L (13.8%)Rejected-AOC | L5 | Rejected-AOC Not lowest |
Tender Value
₹23.1 L
EMD Value
₹46,300
Closing Date
21 Aug 2023, 6:00 pmClosed
GE 871 EWS
GE 871 EWS PIN 913871 C/o 56 APO
SPECIAL REPAIR TO BLDG NO T 10 OF NFS NODE AT MANA UNDER GE 871 EWS
2023_MES_610371_1
8751/E8
Open Tender
Civil Works
Item Rate
180 days
Mana
AS PER NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹46,300
Yes
6 Oct 2023
24 Jul 2023
28 Aug 2023
24 Jul 2023
21 Aug 2023
7 Aug 2023
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness, incl Nainital or similar pattern roof covering all as directed.
Dismantling of Wall and ceiling boards or insulation boards/slabs any thickness, incl cover fillets all as directed.
Demolition of PCC block walling/brickwork or stone boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Taking down cement plaster on brick work or stone walls etc incl raking out joints hacking for key scrubbing down with water complete all as directed.
Demolition of unreinforced cement concrete in ground floor and paving n.exc 15cm thick (below or above ground level) etc complete all as specified and directed.
Taking down chowkats or frames with shutters ( without taking of shutter from the frame) n.exc 1.5 sqm each complete all as directed.
Taking down chowkats or frames with shutters ( without taking of shutter from the frame) exc 1.5 sqm but n.exc 4.00 sqm each complete all as directed.
Dismantling wrought iron or mild steel work/trusses/purlins/pillars of any description not otherwise provided for
S&F Prepainted Galvalume sheet aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of a colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed.
S&F Prepainted Galvalume sheet aluminium zinc coating GI based plain steel sheet 0.50mm thick of a colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed.
S&F for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on wall to make PVC frame as per specification and drawing complete all as directed by Engineer-in-Charge.
S&F for Solid PVC wall lining consisting of 5mm thick single side prelam PVC colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as directed by Engineer-in-Charge.
S&F for frame work for suspended false ceiling GI exposed ceiling suspension system of grid 600x600mm with main runner 38mmx24mm, cross tee 29mmx24mm and wall angle 24mmx24mm including 6mm dia GI/MS bar hanger fixing with steel dash fastener or iron purlins from the roof with adjustment clip providing position for light fixture incl complete fixing arrangement etc all as specified and directed by Engr-in-Charge.
S&F for false ceiling of Everest designer boards of 595x595mmx4mm fixed on GI snap grid complete all as specified and directed by Engr-in-Charge
M&L for pre cast cement concrete solid block masonry 1:3:6 type C-1(using 20mm aggregate)with solid block exc 10cm in width setting in CM 1:4 etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even and smooth without using extra cement in external surfaces complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces with CM 1:6 finished even and smooth without using extra cement in internal surfaces complete all as specified and directed.
M&L for rendering 5 mm thick on ceiling as in chajja in CM 1:3 even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plaster on wall surface apply two coat of Cement based paint over one coat of alkali resistant primer complete all as specified and directed.
M&L for preparing new plaster on ceiling surface apply two coat of Cement based paint over one coat of alkali resistant primer complete all as specified and directed.
M&L for preparing new plaster surface apply two coat of oil bound distemper over a coat of wall care putty to obtained smoothness of wall surfaces over one coat of primer complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) of 25mm thick as in correction/levelling course, finished surfaces even and rough to receive floor finish complete all as directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl over screed bed or bedding layer of mortar 15mm thick for laying tiles in cement mortar 1:6 complete all as directed.
All as per item No 23 but as in skirting over 10mm thick rendering as in backing coat of CM 1:4.
M&L for PCC 75mm thick, 1:4:8 type D-2 40mm stone aggregate as in sub base of flooring complete all as specified and directed.
M & L hard core of broken bricks gauge n. exc 63 mm, deposited spreaded and leveled in layer not exc 15 cm thick, watered and rammed to a true surface, broken stone or boulder.
M&L for rubber polished chequered cement concrete tiles of size 30cm X 30cm X 25mm thick, set and jointed and pointed in neat cement slurry in floors with grey cement and pigments over 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for providing 75mm thick cement concrete in 1:3:6 type C1, (using 20mm graded stone aggregate) finishing cement concrete surface even and fair without using extra cement as in plinth protection complete all as directed.
M&L for providing cement concrete in 1:3:6 type C1, (using 20mm graded stone aggregate) finishing cement concrete surface even and fair as in surface channel complete all as directed.
S&F for Powder coated (Minimum thickness of powder coating 50 microns) aluminium frames and shutters for door and window, ventilator or framing with one or more rebates joining cleat for fixing etc of any type, side hung shutter, sliding shutters etc complete all as specified and directed by Engr-in-Charge. (Glazing, Rubber, Beading and aluminium hardware shall be measured and paid separately).
M&L for Rubber beading for fixing glass pane in aluminium frame work complete all as specified and directed by Engr-in-Charge.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 140mm long complete.
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 100mm MS butt hinges cold rolled mild steel, and fixed complete all as specified and directed.
S&F Aluminium anodised, barrel tower bolts 150mm of extruded section and fixed
S&F Aluminium anodised, barrel tower bolts 75mm of extruded section and fixed
S&F Aluminium anodised, handles 150mm of extruded section and fixed
S&F Aluminium anodised, handles 100mm of extruded section and fixed
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
S&F Sheet glass 4.80mm thick, ordinary quality and glazing with oil putty in square of any size in each pane all as directed by Engr-in-Charge
S&F Sheet glass 4mm thick, frosted glass ordinary quality and glazing with oil putty in square of any size in each pane all as directed by Engr-in-Charge
S&F Brass 4 lever locks, for aluminium door , vertical type, size 100mm complete all as directed by Engr-in-Charge
S&F in repair for Drapery rod, mild steel, chromium plated with fixing brackets, stops etc all as specified and directed by Engr-in-Charge.
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats confirming to Fe 410 W (Gde E-25) quality A all as directed by Engr-in-Charge.
M&L preparation steel surfaces with two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L preparation old steel surfaces and applying two coats of Synthetic enamel paint (Trusses/CGI Sheet as in roof) complete all as specified and directed.
S&F in repair Door closer hydraulically, designation No 3, Aluminium extruded section body, regulated, universal type suitable for door shutters of 851 to 1000mm width and of weight 61 to 80kg and fixed as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as directed by Engr-in-Charge.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
S&F in repair Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handle etc as specified, erected in position and securing runners with holdfasts and brackets, complete all as directed by Engr-in-Charge.
M&L Providing Precast cement concrete 1:2:4 type B-1(using 20mm graded stone aggregate) in landings, cover slabs as drain cover, chajjas, water troughs, mangers, shelves set in CM 1:4 all as specified and directed.
S&F Mild steel TMT bars as in reinforcement 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking into credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed
M&L for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles all as specified and directed for One light/bell point controlled by one ,one way switch
All as per item No 55 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 55 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 55 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F in replacement switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F in replacement switch piano flush type 15/16 Amps single pole one way all as specified & directed.
M&L in replacement socket out let 5 pin 5/6 Amps all as specified and directed.
S&F in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F in replacement ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified and directed.
S&F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
S&F 9 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed.
S&F in replacement LED tube light fitting bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed.
Supply and fix in replacement of LED slim square panel light fitting, 36 Watt, 2x2 feet edge-lit luminaire suitable for arm strong/grid ceiling for low ceiling and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
M&L in replacement of sub main wiring in PVC concealed conduit of required size 2 x 4 sqmm PVC insulated multistrand copper conductor FRLS with 01x 4 Sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Note:- For the purpose of payment two runs of 4 sqmm conductors and one run of 4sqmm conductor with conduit will be measured as one length.
M&L in replacement earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Taking down and refixing of LED tube light fitting bright 18 Watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply and fix in replacement VTPN DB 4-ways, IP 43 - IK 09 with metal door (DPX3 63+12) suitable for surface/flush mounting as per site requirement with copper bus bar, with neutral bar, earth bar and cable ties for cable arrangement, fully insulated bus bar and neutral bar, door earthing, corner shield for better protection, pan assembly confirming to IS 8623 including making fixing arrangement with existing wall all as specified.
Supply and fixing MCCB 63 Amps 4 pole 415 volts 25 kA Ics=75% Icu including extended terminals all as specified and directed.
Supply and fix in replacement MCB 6-32 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed.
Supply and fix in replacement MCB 40 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed .
Supply and fixing plug and socket outlet (with industrial plug and socket ) with provision to mount MCBs 40A including 40A DP MCB , C series , 2 module , IP 30 degree protection complete all as specified and directed . .
Supply & fix in replacement of on load change over switch 4 pole, 63 Amps suitable for 3 phase, 415 Volts in sheet metal enclosures fitted on angle iron of size 40x40x5mm for fixing on ground complete all as specified & directed. .
Disconnecting and taking down existing Unserviceable PVC Body / Steel body Exhaust fan of any description and depositing to MES Store yard complete all as specified and directed
S & F exhaust fan , steel body AC Single phase 230 volt of size 300mm sweep with , blades and frame and louvers including twin core cable for connection from exhaust fan to ceiling rose , necessary repair to existing hole by plastering complete all as specified and directed.
S&F wooden block heavy weight of size 15x10x15cm with a hole of size 20mm for fixing of air termination rod of any size including dismantling and taking down existing unserviceable wooden block complete all as specified and directed.
S& F air termination five pointed rod aluminium rod 12mm dia and 300mm long complete all as specified and directed.
Test point terminal block of gun metal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 03 Nos 8 mm dia 25mm long hex head screw complete all as specified and directed .
Supply and fixing Aluminium strip 25X3 mm with saddles and fixing screw etc for roof conductor and down conductors and down conductors above ground complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and including galvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanised steel protection pipe light grade 40mm dia and GI pipe light grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion. Note : The unit rate includes for 40mm light grade protection pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level. The earth pit shall be constructed atleast 1.5m away from the top of earth electrode.
S&F tube light grade galvanised iron with all fittings laid in trenches or surface of dia 25mm complete all as specified and directed
S&F tube light grade galvanised iron with all fittings laid in trenches or surface of dia 40mm complete all as specified and directed
Excavation in trenches nexc 1.5 m wide and nexc 1.5 metre in depth for foundation and getting out in hard dense soil all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers nexc 25 cm thick in soil all as specified and directed.
Removing excavated soil to a distance nexc 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable all as specified and directed. Note :- For the purpose of payment only punned thickness will be measured.
M&L for providing new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable all as specified and directed.
Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor , 1100 volt grade ,cross sectional area 35 Sq mm 3.5 Core all as specified and directed.
M/S Swarn Constructions
Ram Naresh Singh Sikarwar
M/S RAMESH LAL
SIDHARTH CONSTRUCTION
Harendra Singh Panwar
M/S ANSULBHUJWAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .