Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹4.6 LAccepted-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | ₹4.6 L Quoted ₹4.8 L | 1st | Accepted-AOC Contract awarded to M/s Garhwal Enterprises please see uploaded AOC for details. |
| 2 | 2nd₹5.3 L+₹54,461 (11.4%)Rejected-Finance GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹5.3 L+₹54,461 (11.4%) | 2nd | Rejected-Finance L2 |
| 3 | 3rd₹5.4 L+₹64,860 (13.5%)Rejected-Finance MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹5.4 L+₹64,860 (13.5%) | 3rd | Rejected-Finance L3 |
| 4 | 4t₹5.5 L+₹70,114.50 (14.6%)Rejected-Finance GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹5.5 L+₹70,114.50 (14.6%) | 4t | Rejected-Finance L4 |
| 5 | 5th₹5.6 L+₹84,991 (17.7%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹5.6 L+₹84,991 (17.7%) | 5th | Rejected-Finance L5 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
23 Dec 2023, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR AND MAINTENANCE OF INTERNAL WIRING, SUB MAIN WIRING AND FITTINGS AND FIXTURES, GEYSERS CEILING FANS, EXHAUST FANS AND ALLIED WORKS AT KOTDWARA UNDER AGE(I) LANSDOWNE.
2023_MES_630010_1
8853/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹16,000
Yes
15 Jan 2024
25 Nov 2023
29 Dec 2023
25 Nov 2023
23 Dec 2023
10 Dec 2023
Amount
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Taking down carefully by unscrewing from ceiling roses, Light fittings, switch , sockets, regulators for reuse at site and carrying to the store when re-fix the serviceable materials Complete all as specified and directed (To be measured only when found serviceable in all respect for reuse. )
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old U/S TPN DB/SPN DB any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit,medium grade(ISImarked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item no 5.00 but for One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per item no 5.00 but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per item no 5.00 but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified & directed.
All as per item no 5.00 but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
All as per item no 5.00 but in existing concealed conduit inside wall, ceiling etc (light, fan, call bell) complete all as specified and directed.
All as per item no 6.00 but in existing concealed conduit inside wall, ceiling etc (5 amps socket on same board) complete all as specified and directed.
All as per item no 7.00 but in existing concealed conduit inside wall, ceiling etc (5 Amps socket on Independent board) complete all as specified and directed.
All as per item no 8.00 but in existing concealed conduit inside wall, ceiling etc (15 Amps socket on Independent board) complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including, PVC Casing Caping "medium grade" (ISI marked) , of 20 mm size fixed on wall/ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed.
All as per Item No14 above but for (5 amps socket on same board) complete all as specified and directed.
All as per Item No 14 above but for (5 amps socket on Independent board) complete all as specified and directed.
All as per Item No 14 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified and directed.
S & F switch Modular single pole, one way 6 Amps , 1 module,ISI Marked 230 volts, 50 hz complete all as specified and directed.
Supply and fixing switch modular , one-way 16Amps, 1 module ISI marked 240 Volts AC complete all as specified and directed.
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module ISI Marked 230 volts, 50 hz complete all as specified and directed.
Supply and fixing switch modular single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all complete all as specified and directed.
Supply and fixing step socket type modular fan regulator 120W/230 V 1 module, ISI marked complete all as specified & directed.
Supply and fixing bell push modular single pole one way 6 Amps, 1 module , ISI marked complete all as specified & directed.
Supply and fixing bell ding dong AC 230/240 volts single pole, complete all as specified & directed.
Supply and fixing ceiling rose surface bakelite 65 mm dia having three terminals complete all as specified & directed.
Supply and fixing Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings complete all as specified & directed.
S&F in repairs switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked complete all as specified and directed.
S&F in repair switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps ISI markd single pole one way complete all as specified and directed.
S&F in repairs, socket out let 3/5 pin 5/6 Amps flush type complete all as specified and directed.
S&F in repair socket outlet 5/6 pin 5/15 ampISI Markd flush type multi suitable for 240 volts AC ISI marked complete all as specified and directed.
S&F in repair batton/angle holder insulated body with back plate, suitable for batten fittings complete all as specified & directed.
S& Fsurface mounted LED luminiare, 20 watt with all accessories having aluminum extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed.
S&F Straight Linear 10Watt, LED Tube light fittingaluminum extruded body for mirror light, 2ft long with LED light source with uniform light output, , Surge protection range-2KV , Voltage- 120- 280 V AC, System efficacy not less than 110 lumen /watt, power factor >0.98, THD <20%, CRI >80, CCT 6500K, fixed on site with all accessories all as specified directed, Make: shakti/C&S/Havells
S&F Decorative gate light made up of high grade unbreakable polycarbonate material complete with 18 Watt LED type including connecting up with twine core twisted flexible copper conductor cable with suitable size of 230v, 50HZ all as specified & directed.
S&F 36 Watt, LED Panel 2X2 Feet environmental friendly, fully diffused, using engineering grade aluminum diffuser, new generation, aesthetically designed, CRCA housing, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.98, thd<15%, CCT 6500K, with separate electronic driver ceiling light 36W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specified & directed.
S&F 36 Watt, LED Panel 2X2 Feet environmental friendly, fully diffused, using engineering grade polycarbonate diffuser, new generation, aesthetically designed, CRCA housing, ultra modern Surface mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.98, thd<15%, CCT 6500K, with separate electronic driver ceiling light 36W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specified & directed.
S&F 18 Watt LED Panel 1X1 feet environmental friendly, new generation, aesthetically designed, flat panel for recess mounting which provides soft-light and glare free symmetrical illumination, Voltage range-120V-280V AC, system efficacy -110 Lumen/Watt, power factor >0.98, thd<15%, CCT 6500K,with separate electronic driver ceiling light 18W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specifified & directed.
S&F 18 Watt LED panel 1x1 feet environmental friendly, new generation aesthetically designed flat panel for surface mounting which provides soft-light and glare free symmetrical illumination, Voltage range-120V-280V AC, system efficacy -110 Lumen/Watt, power factor >0.98, thd<15%, CCT 6500K, with separate electronic driver ceiling light 18W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specifified & directed.
S&F 10 Watt LED aluminum Bulkhead surface mounted with opaque aluminum diffuser for optimum light output IP65 environmental friendly, Voltage range-120V-280V AC,power factor>0.98 system complete including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specifified & directed.
Supply and fixing sheet metal enclsoure double door type for MCCB DB TPN 4 way Vertical including MCCB 4 pole, adjustable thermal & fixed magnetic type 63 Amp, 26 KA, 4 pole MCCB of Make Legrand, ABB, Schnedier all as specifie and directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with 200 Amps rated bus bar complete all as specified and directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar complete all as specified and directed .
Supply & fixing MCB, TPN, AC, 415 volts of 40-63Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply and fixing MCB SPN 10- 32 Amp 240 V AC 10 KA B curve repturing capacity complete all as specified& directed.
Supply and fixing MCB SP 6 to 32 Amp 'B' series 10 KA 240 V AC 50 Hz repturing capacity complete all as specified & directed.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit surface/ concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly complete all as specified and as directed. Note: Two runs of phase, netural wire and one run of earth wire will be measured as one RM or one length.
S&F service cable 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended with insulating hanger not more than 1 mtr apart including 4 mm dia suspension wire alongwith 10 Sqmm twin core flat cable all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to DB, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Fixing only serviceble light fitting retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable switches retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable sockets retrived from Item No-02 above complete all as specified and directed.
Taking down ceiling fan of 1200/1400 mm sweep removing and cleaning of dust properly, oiling & greasing of bearing with and including replacement of washer and any other minor spare parts such as new screw, check nut, pin etc and refixing in position, connecting, testing complete all as specified and directed.
Taking out & removing old burnt-out winding of electric fans of size 1200/1400 mm sweep and rewinding of fan motor with appropriate size super enamelled copper wire (Make : Atlas/Finolex/Devi Dayal) as approved by the Engineer-in -charge including insulating material such as illuminous paper Leatherized paper,cotton tape,glass sleeving,insulating varnish incl ball bearing/bushes/hanging assembly if required etc testing at workshop and transportation to site,connecting and testing on full load to the entire satisfaction complete all as specified and directed.
M&L spray painting of Ceiling fans complete, in situ with synthetic enamel paint of any tint as approved by Engg-in-Charge by spraying including filling cavities with filler ,one coat after cleaning all dust of any size including fan blades complete all as specified and directed.
S&F in replacement of condenser 3.15 MFD for fan complete all as specified and directed.
Panwar Electrical
A ONE BUILDERS AND ENGINEERS
PIONEER REFRIGERATION AND ELECTRICALS
Bedi Refrigeration Works
S.M. KAZIM
Deven Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .