| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹41.7 L+₹1.5 L (3.79%)Rejected-Finance 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹43.6 L+₹3.4 L (8.49%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹44.3 L+₹4.1 L (10.2%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L4 | Rejected-Finance NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Shri Electrical Enterprises L3 | DIWAKAR CONSTRUCTION CO. L4 | SACHIYAY MAA ELECTRICALS L1 | GITANSH ENGINEERS AND COMPANY L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying, testing & commissioing of 10 Sqmm 2 core size XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 Part I marked, suitable for LT 1100 Volt system,laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe including jointing & testing and taking down old U/S cable complete all as specified and as directed
Note :- Excavation, earth work ,cable protection , sand fillings shall be measured and paid separately under respective items of schedule. | 600 | RM | 97 ₹58,200 Lowest | 130 ₹78,000 | 110 ₹66,000 | 99 ₹59,400 |
| 2.00 | All as per Ser No 1 above but size 10 sqmm 4 core | 400 | RM | 145 ₹58,000 | 130 ₹52,000 Lowest | 155 ₹62,000 | 142 ₹56,800 |
| 3.00 | All as per Ser No 1 above but size 16 sqmm 4 core | 500 | RM | 175 ₹87,500 | 150 ₹75,000 Lowest | 165 ₹82,500 | 175 ₹87,500 |
| 4.00 | All as per Ser No 1 above but size 25 sqmm 4 core | 600 | RM | 210 ₹1,26,000 | 175 ₹1,05,000 Lowest | 210 ₹1,26,000 | 220 ₹1,32,000 |
| 5.00 | All as per Ser No 1 above but size 35 sqmm 3.5 core | 400 | RM | 265 ₹1,06,000 | 200 ₹80,000 Lowest | 250 ₹1,00,000 | 280 ₹1,12,000 |
| 6.00 | All as per Ser No 1 above but size 50 sqmm 3.5 core | 300 | RM | 315 ₹94,500 | 330 ₹99,000 | 280 ₹84,000 Lowest | 352 ₹1,05,600 |
| 7.00 | All as per Ser No 1 above but size 70 sqmm 3.5 core | 200 | RM | 375 ₹75,000 Lowest | 398 ₹79,600 | 450 ₹90,000 | 550 ₹1,10,000 |
| 8.00 | All as per Ser No 1 above but size 120 sqmm 3.5 core | 250 | RM | 700 ₹1,75,000 | 600 ₹1,50,000 Lowest | 630 ₹1,57,500 | 688 ₹1,72,000 |
| 9.00 | All as per Ser No 1 above but size 300 sqmm 3.5 core | 100 | RM | 1,570 ₹1,57,000 | 850 ₹85,000 Lowest | 1,500 ₹1,50,000 | 1,650 ₹1,65,000 |
| 10.00 | All as per Ser No 1 above but size 400 sqmm 3.5 core | 100 | RM | 1,900 ₹1,90,000 | 1,150 ₹1,15,000 Lowest | 1,900 ₹1,90,000 | 2,000 ₹2,00,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Jun 2025, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND MAINT OF LT CABLES PANELS FEEDER PILLAR BOXES POLES AND CONNECTED ITEMS IN A A BANAR UNDER GE BANAR
2025_MES_709521_1
8825/23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Banar
₹90,000
Yes
13 Sept 2025
22 May 2025
26 Jun 2025
22 May 2025
19 Jun 2025
5 Jun 2025
Amount
Supply, laying, testing & commissioing of 10 Sqmm 2 core size XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 Part I marked, suitable for LT 1100 Volt system,laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe including jointing & testing and taking down old U/S cable complete all as specified and as directed Note :- Excavation, earth work ,cable protection , sand fillings shall be measured and paid separately under respective items of schedule.
All as per Ser No 1 above but size 10 sqmm 4 core
All as per Ser No 1 above but size 16 sqmm 4 core
All as per Ser No 1 above but size 25 sqmm 4 core
All as per Ser No 1 above but size 35 sqmm 3.5 core
All as per Ser No 1 above but size 50 sqmm 3.5 core
All as per Ser No 1 above but size 70 sqmm 3.5 core
All as per Ser No 1 above but size 120 sqmm 3.5 core
All as per Ser No 1 above but size 300 sqmm 3.5 core
All as per Ser No 1 above but size 400 sqmm 3.5 core
Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole as a foundation or in any situation complete all as specified.
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole by demolition of existing /broken coping or in any situation complete all as specified.
Excavation in trenches in soft/ loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified.
All as per item No 13 here in before but exc 1.5 mtr in depth complete all as specified.
M&L for tibba sand locally available sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified.
M&L for laying jodhpur stone quarry stone slab cover 25 to 30cm in width, 60cm long and 40 to 50 mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered under ground cables complete all as specified.
Returning, filling, in including spreading, leveling , watering and well ramming in layers n.exc 25 cm in soil complete all as specified.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified.
Supply and fixing in replacement GI Pipe light grade 80 mm dia with necessary accessories/ fittings bracing with pole/wall by FI clamps for cable protections/pole for crossing of culverts/nallah complete all as specified. sizes:-
All as per ser item No 19 above but of size 50 mm dia
All as per ser item No 19 above but of size 40 mm dia
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified.
Arranging fault locating machine to locate the fault in underground elect power cables of any length and any type of 1100 Volts grade LT cable and pin point the fault and testing of the cable after locating fault and cutting the cable at fault to check healthiness of cable before and after including excavation and earth work in any type of soil complete all as specified.
Supply, fixing and testing in replacement straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 16- 35 Sqmm x 3.5 core/4 core complete all as specified.
All as per ser item No 24 above but of size 50-70 Sqmm x 3.5 core
All as per ser item No 24 above but of size 95-120 Sqmm x 3.5 core
All as per ser item No 24 above but of size 150-185 Sqmm x 3.5 core
All as per ser item No 24 above but of size 240-300 Sqmm x 3.5 core
Supply, fixing and testing in replacement end joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 10-35 Sqmm x 3.5 core complete all as specified.
All as per ser item No 29 above but of size 50-70 Sqmm x 3.5 core
All as per ser item No 29 above but of size 95-120 Sqmm x 3.5 core
All as per ser item No 29 above but of size 150-185 Sqmm x 3.5 core
All as per ser item No 29 above but of size 240-400 Sqmm x 3.5 core
Material and labour for disconnecting power supply from LT ACB of cap. 800/1000/1500 Amps for repair works , taking out trolly unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part , cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley, checking proper operation of trolly all as directed, inserting trolley inside and testing and putting on load complete all as specified.
Supply and fixing in replacement of manual on load change over switch 4 pole, 415 Volts 50 Hz 100 Amps with sheet steel enclosure mounted on wall or fixing in existing panel with all fixing arrangement complete all as specified.
All Asper Srl Item No 35 above but of 160 Amps Capacity
All Asper Srl Item No 35 above but of 250 Amps Capacity
All Asper Srl Item No 35 above but of 400 Amps Capacity
S&F in replacement of MCCB,4 pole 100 Amp 16 KA , suitable for 415 volts, 50HZ 3 Phase, with adjustable Thermal & fixed magnetic,, over load and short circuit setting on LT panel/feeder pillar complete all as specified.
All as per ser item No 39 above but of capacity 125 Amps,4pole 415 volts 25 KA
All as per ser item No 39 above but of capacity 160 Amps,4pole 415 volts 36KA
All as per ser item No 39 above but of capacity 200 Amps,4pole 415 volts 36KA
All as per ser item No 39 above but of capacity 250 Amps,4pole 415 volts 36KA
All as per ser item No 39 above but of capacity 315 Amps,4pole 415 volts 36KA
All as per ser item No 39 above but of capacity 400 Amps,4pole 415 volts 36KA
All as per ser item No 39 above but of capacity 630 Amps,4pole 415 volts 50KA
Repair & maintenance of LT Panel board in door/outdoor type comprising of MCCBs as incoming and outgoing with digital mettering and control wiring by disconnecting all incoming and out going connection, opening of LT cable incl reconnect the cable by excavating the loop and making connection tight by replacing the suitable size of heavy duty lugs with new nut bolts and washers and gland complete. Cleaning of all compartment from in side and out side including using anti rust spray and checking and repair of all controls, switches, meters. etc (if found diffective) Refixing of panel board upon new angle iron stand fixed at 75 cm made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6 B2 type complete. Note: 1. The MCCBs, and MCBs. will be measured and paid saperately in respective Sch A item. 2. The charges for Voltmeter meter, Amp meter, Lugs, control wiring and angle iron size of 50x50x6 mm & PCC work is deemed to be included in above quoted rates.
Suupply and Fixing in replacement of Digital Volt Meter 0-500 V including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified.
Suupply and Fixing in replacement of Digital Amp Meter 0-400 Amp with CT three nos of same rating including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified.
Material and labour for scraping the rusted surface of LT panel/feeder pillar any descreption/size (approx size 2 to 4 Sqm) and applying the primer coat of red oxide and painting on surface of LT Panels/feeder pillars 2 coats of super enamal paint grey/sky blue/existing colour with sparygun including writing of feeder pillar numbers in appropriate size of letters complete all as specified.
Suupply and Fixing in replacement of Mild steel sliding door bolts plate type, stove enamelled black, with bright bolt not less than 12mm dia, 200mm long bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed on front side door of LT panel board complete all as specified.
Material and labour for repairing/replacing the broken hinges of LT panel shutters with stainless steel hinges of 200mm long by welding/bracing with nut bolts of existing LT panels shutters of any descreption complete all as specified.
Material and labor for edging the machine cut /true dressed jodhpur stone patty of size 30 cm in width, 60 cm long and 50 mm thick, to make edge aroung the LT Panels complete all as specified.
Supply and laying the graded coarse aggregate 40mm size for loose filling around the LT Panels or under 2/4/6 poles structure surface dressing and cleaning the vegetation before spreading the gravel and complte all as specified.
M&L in replacement of earthing with Galvanised Steel earthplate of size 60x60cmx6mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). Note: Testing of earthing shall be carried out after completion of earthing.Payment for earthing shall be admissible after satisfactory test result.
M&L in replacement of GI strip of size 32x6 mm including mounting on PVC/Porcelain insulators on wall and burried in ground depth not less than 60 cm in ground complete all as specified.
Labor for cutting and removing grass, vegetation, bushes/shrubs etc from surrounding of 02 Pole/ 4 Pole structure and LT/ HT Panel E/M installations and removing all rubbish and dressing the gravel/soil and spaying the one time herbicide approved brand (Roundup/Noweed) to prevent the further vegetation complete all as specified.
Restretching aluminium conductor or GI wire on existing over head lines without removing including unbinding from insulator and rebinding to insulator using aluminium binding wire, connections of incoming and outgoing cables, binding with spacers where required, complete all as specified Note :- (i) Length of span shall be 40 to 50 m. (ii) Due care shall be given while resagging of overhead conductor that there shall be no damage to pin/post/disc insulator and pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible.(iii) Proper shut down will be taken from department and T&P will be provided by contractor
Dismantling and taking down old ACSR conductor complete all as specified.
Fixing and restretching of old serviceable (ACSR) conductor obtained from items No 59 here in before including binding complete all as specified.
Supply and fixing ACSR conductor including binding of wire and providing jumpers at the end as per site requirement complete all as specified.
S&F Pin type, pocelain, vitreous, white brow or green insulator including one galvanised mild steel spindle, two galvaanised iron washers and one galvanised iron nut, 100mm height, 65 mm dia for 1100 volts grade with fixing on existing 2 pole/4pole/single pole including taking down of old unsv insulator complete all as specified.
Supply only Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps (31 x 5mm), washers, insulators bolts 14mm, washers and nuts, working pressure 1100 volts, height 100 mm, 115mm dia, complete all as specified
S&F PVC seperators/spacers clamp mounted on ACSR conductor suitable for 4 run
S&F PVC seperators/spacers clamp mounted on ACSR conductor suitable for 2 run
Supply and fixing in replacement of cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holesfor bolt. In any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified.
M&L for painting black and white strips 05 Nos (each strips of 30 cm height) with synthetic enamel paint of black and white colour round the PCC/steel tubular pole alternatevely from the bottom of the pole and also including numbering of pole both side with black paint in Yellow background complete all as specified.
Supply and fixing in replacement of pole mounted junction box of inside dimension 240x130x110 made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 5/6 Amp rating MCB SP-01 No, up to 100 Amp rated 3 pole connector suitable to insert the cable size 25 Sqmm-01 No,with neutral link and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cales complete all as specified.
Supply and fixing in replacement of pole mounted junction box of inside dimension 300x200x105 mdae out of FRP body (hot mulded type) with IP-66 protection and locking with screws comprising of aluminum bus bar rating 100 Amp, 4 strips for 3 phase and neutral along with 6 Amp rating MCB SP-01 No and duly fixed on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and outgoing cables complete all as specified.
Trimming and cutting of tree branches coming across LT over head line, clearing alround 3m the LT line and disposal of branches/bushes to a distance upto 50m and cleaning the site complete all as specified. Note :- (i) Length of span shall be 40 to 45m. (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible.(iii) Proper shut down will be taken from department and T&P will be provoded by conractor.
Taking out faulty underground LT 1100 volts grade heavy duty, armoured with steel strip of wire, with stranded aluminium conductor of sizes up to 16 Sqm 4 core by excavation and relaying same laocation or any other location rectification of fault and removing of surplus soil. Note: Excavation, stone for cable cover, tibba Sand and earth work will be measured and paid for seperately under respective items of schedule.
All as per srl item 71 here in above but of size 25 Sqmm to 50 Sqmm
All as per srl item 71 here in above but of size 70 Sqmm to 120 Sqmm
All as per srl item 71 here in above but of size 150 Sqmm to 240 Sqmm
Supply and errecting in replacement of Prestressed concrete pole, 9.0 meter long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level and including dismantling and taking out the damaged/old PCC pole and setting aside within 50 mtr distance and opening the street light bracket/crossarms with connected items and street light fitting from old pole and refixing the same on new pole for street light fitting complete all as specified.
S&F in replacement of GI stay assembly set comprising of 14mm dia 400mm iron stay bow and16mm dia, 2150mm long stay rod stay plate 230x230x6mm thick, GI stay wire 7/8 SWG of required length complete with all accessories as shown in electric plate No 1 of SSR Part 1 2009 complete with excavation earth work including PCC 1:3:6 of required quantity with loop insulator, clamps nut bolts etc complete all as specified.
Supply and installation, testing and commissioning in replacement of LT panel factory made suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply system confirming to IS:8623/93, outdoor type, double door floor mounting weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 1000 Amp three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable door locking arrangements, mounted on angle iron stand fixed at 75 cm height made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1350x450mm, (ii) Drawing of LT Panel shall be submitted by manufacturer before placing order and will be approved by GE. INCOMING:- MCCB 4P 630 Amp 50 KA thermal adjustable type-01 Nos OUTGOING :- (i) MCCB 4P 400 Amp 36 KA thermal adjustable type -01 Nos, (ii) MCCB 4P 315 Amp 36 KA thermal adjustable type -01 Nos (iii) MCCB 4P 125 Amp 25 KA thermal adjustable type-02 No (iv) MCB TPN 415 Volt 10 KA 'B' Curve 63 Amp -02 Nos (v) Digital type volt meter & Amp Meter-01 Nos (vi) LED type Indicating Lamp - 3 Nos
Supply and installation, testing and commissioning in replacement of LT panel factory made suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply system confirming to IS:8623/93, outdoor type, double door floor mounting weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 500 Amp three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable door locking arrangements, mounted on angle iron stand fixed at 75 cm height made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1350x450mm, (ii) Drawing of LT Panel shall be submitted by manufacturer before placing order and will be approved by GE. INCOMING:- MCCB 4P 315 Amp 36 KA thermal adjustable type OUTGOING :- (i) MCCB 4P 250 Amp 36 KA thermal adjustable type -01 Nos, (ii) MCCB 4P 125 Amp 25 KA thermal adjustable type -02 Nos (iii) MCB TPN 415 Volt 10 KA 'B' Curve 63 Amp -02 Nos (iv) Digital type volt meter & Amp Meter-01 Nos (v) LED type Indicating Lamp - 3 Nos
Supply and installation, testing and commissioning in replacement of LT panel factory made suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply system confirming to IS:8623/93, outdoor type, double door floor mounting weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 400 Amp, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable door locking arrangements, mounted on angle iron stand fixed at 75 cm height made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears. (Note: (i) The size of Feeder pillar box should not be less than 1100x1350x450mm, (ii) Drawing of LT Panel shall be submitted by manufacturer before placing order and will be approved by GE. INCOMING:- MCCB 4P 250 Amp 36 KA thermal adjustable type OUTGOING :- (i) MCCB 4P 100 Amp 36 KA thermal adjustable type -04 Nos, (ii) MCB TPN 415 Volt 10 KA 'B' Curve 63 Amp -01 Nos (iii) Digital type volt meter & Amp Meter-01 Nos (v) LED type Indicating Lamp - 3 Nos
GITANSH ENGINEERS AND COMPANY (BID ID -3320538)
Shri Electrical Enterprises (BID ID -3318966)
DIWAKAR CONSTRUCTION CO. (BID ID -3329589)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .