Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹21.7 L+₹3.2 L (17.2%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹23.0 L+₹4.5 L (24.1%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST | |
| 4 | L4₹24.9 L+₹6.4 L (34.8%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST | |
| 5 | L5₹25.7 L+₹7.2 L (39.0%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
17 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA J AND K PIN-900176 C/O 56 APO
REPLACEMENT TO BURNT OUT LT UG CABLES POLES AND ALLIED CONNECTED WORKS UNDER AOR OF GE SAMBA AT MIL STN SAMBA
2022_MES_568476_1
GE/SMB/T-66/2022-23
Open Tender
Civil Works
Item Rate
180 days
SAMBA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
₹48,000
Yes
4 Feb 2023
17 Dec 2022
19 Jan 2023
17 Dec 2022
17 Jan 2023
3 Jan 2023
17 Dec 2022 - 19 Dec 2022
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables, poles & stay or other items and getting out soil in any type soil complete all as specifed.
Excavation in trenches not exceeding 1.5 mtr wide and exc. 1.5 m but not exceeding 3.0 mtr in depth for poles or other items and getting out soil in any type soil complete all as specifed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified
Sand cushioning to under ground electric cable a layer of 8 cm thick before laying the cable and stretching the cable and second layer of 15 cm thick after laying the cable and punned down to form a bed of 18 cm complete all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be of good quality as specifed and punned thickness shall be measured and paid.
Sub class 'B' bricks Well burnt of size 230mmX115mmX75mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles including use of necessary form works for rough finished surface complete all as specified and directed.
Plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping to poles including use of necessary form works for rough finished surface complete all as specified and directed.
GI pipe 50 mm bore ( Light grade ) in replacement for protection of LT cable fixed to walls/ poles/road crossing including suitable size clamps complete, complete all as specified and directed
GI pipe 80 mm bore ( Light grade ) in replacement for protection of LT cable fixed to walls/ poles/road crossing including suitable size clamps complete, complete all as specified and directed
XLPE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 16 sqmm, 4 core with stranded aluminium conductor including proper connection to LT panel / bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XLPE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 25 sqmm, 2 core with stranded aluminium conductor including proper connection to LT panel / bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XLPE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 25 sqmm, 4 core with stranded aluminium conductor including proper connection to LT panel / bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XLPE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 50 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel / bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XLPE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 70 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel / bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XLPE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 95 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel / bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XLPE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 120 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel / bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
Bus bar chamber , 3 phase 415 volts, 4 ways having aluminium bus bar of capacity 200 Amps, fixing on angle iron of size 40mmx40mmx5mm grouted in PCC 100 mm thick and also provide around tha bus bar for PCC 1:3:6 100 mm thick C-1 using 20 mm graded crushed stone aggregate in foundation to avoid vegetation, minimum ground clearance 30 cm, front and rear opening doors having locking arrangement complete all as specified and directed. Make of bus bar chamber : Havells Cat Part No. IHBC020004 or technocommerically equivelent to Legrand/ ABB / C&S/ Schneider.
Bus bar chamber , 3 phase 415 volts, 4 ways having aluminium bus bar of capacity 100 Amps, fixing on angle iron of size 40mmx40mmx5mm grouted in PCC 100 mm thick and also provide around tha bus bar for PCC 1:3:6 100 mm thick C-1 using 20 mm graded crushed stone aggregate in foundation to avoid vegetation, minimum ground clearance 30 cm, front and rear opening doors having locking arrangement complete all as specified and directed. Make of bus bar chamber : Havells Cat Part No. IHBC006304 or technocommerically equivelent to Legrand/ ABB / C&S/ Schneider.
LED street light fitting with dusk down (LDR Sensor) 60 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts including three core PVC insulated cable with multi stranded, unsheathed of size 1.5 Sqmm (FRLS) 1100 volts for connection from junction box to security light to be laid inside PVC conduit 20 mm dia 1.8 mm thick duly fixed with 2 nos MS clamp fabricated to the shape of PCC/Steel tubular pole made out of MS plate 25x3 mm thick complete with nuts, bolts and washer from junction box to GI bracket of street light fittings including taking out old u/s existing flood light with fittings, complete all as specified and directed. Make:-HPL Cat Part No. HPLLEDDSL6060WS or its techno commercially equivalent in Philips/Havells/Wipro/Crompton/Polycab. Note- Street light fittings, PVC Conduit, street light bracket shall be included in quoted rate.
LED street light fitting with dusk down (LDR Sensor) 90 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts including three core PVC insulated cable with multi stranded, unsheathed of size 1.5 Sqmm (FRLS) 1100 volts for connection from junction box to security light to be laid inside PVC conduit 20 mm dia 1.8 mm thick duly fixed with 2 nos MS clamp fabricated to the shape of PCC/Steel tubular pole made out of MS plate 25x3 mm thick complete with nuts, bolts and washer from junction box to GI bracket of street light fittings including taking out old u/s existing flood light with fittings, complete all as specified and directed. Make:-HPL Cat Part No. HPLLEDDSL9060WS or its techno commercially equivalent in Philips/Havells/Wipro/Crompton/Polycab. Note- Street light fittings, PVC Conduit, street light bracket shall be included in quoted rate.
LED flood light, 170/180 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) including taking out old u/s existing flood light with fittings, complete all as specified and directed. Make:-Polycab or its techno commercially equivalent in Philips/Havells/Wipro/Crompton/HPL.
Replacement of Junction box CPRI approved factoy made of minimum size 30cm (height) x 20cm (width) x 20cm (depth) made of steel sheet 3.15 mm thick duly painted with two coat of synthetic enamel paint over a coat of red oxide primer having aluminium bus bar 4 Nos of capacity 100 Amps with minimum 04 Set of nuts, bolts & washers on each busbar mounted on porcelain/PVC insulator having 01 No MCB, SP, 06 Amps. Junction box shall be fixed on PCC/ Steel pole including suitable clamps . entry of cable of size upto 25 sqmm including making electrical connection with & including suitable cable glands, thimbles complete all as specified.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and directed by Engr-in-Charge.
Structural steel work conforming to Grade Fe-410 S as in cross arms, bracing, supports, clamps, back plates, fabricated from steel section incuding nuts,bolts and washers welding,drilling hole complete with two coats of aluminium paint over one coat of primer red oxide complete all as specified and directed.
Supply & errection Pre-stressed concrete poles 9 meter long 102 x 172 mm top and 102 x 279 mm at bottom, class-10, errecting in truely vertical position, making 30 cm wide strip (total 5 nos) with black and yellow paint including numbering,complete all as specified and as directed. (Note : Excavation & earth work, PCC shall be measured and paid for separately under respective items of BOQ).
Stay assembly complete with accessories as shown in electrical plate No. 1 of 16 mm dia rode complete all as specified and directed.
Replacement loop type insulator, vitreous porcelain, white brown or green with overall dimensions 65x90 mm clearance of hole 16 mm including dismantling old unserviceable insulator, complete all as specified and directed.
Galvanized stranded stay wire of size 7/3.15 mm including necessary binding with insulator, clamp and stay clamp, complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
dinesh enterprises
M/S NINDI BUILDERS
KALSI CONSTRUCTION CO
Jiwan Singh
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .