| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-Finance | ₹20.5 L | L1 | Accepted-Finance LOWEST |
| 2 | L2₹21.1 L+₹54,484.03 (2.65%)Rejected-Finance | ₹21.1 L+₹54,484.03 (2.65%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹22.3 L+₹1.7 L (8.43%)Rejected-Finance | ₹22.3 L+₹1.7 L (8.43%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT RECOMMENED DUE TO CONTRACTOR NOT ENLISTED IN C (i) CATEGORY |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT RECOMMENED DUE TO CONTRACTOR NOT ENLISTED IN C (i) CATEGORY |
| Sl No | Description | Qty | Unit | Vishav Karma Refrigeration and Electric Work L1 | ARORA ENTERPRISES L2 | M/S KANWAR VIKAS SINGH L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply,installation ,testing of horizontal centrifugal multistage pumping set electric driven 2940 RPM with CI Impeller and steel shaft having discharge 5.3 LPSat 350 MTR Head coupled with squirrel cage induction motor of capacity not less than 50HP ,415 AC, 3 phase 50 HZ, mounted on common MS base plate ( Factory assemblled ) and foundation of the pump set including PCC foundation ,MS bolts with nots and anti viberation pads with stainless steel glycerin pressure gauge type complete al as specified and directed .
Note : Rates for any modification in suction and discharge by providing MS pipe , connecting suction and discharge line to the pump set and making new PCC foundation for installation of pumping set and other misc work realted to pumping set shall be included in the quoted rate. | 2 | Each | 5,09,338 ₹10,18,676 Lowest | 5,50,000 ₹11,00,000 | 5,50,000 ₹11,00,000 |
| 2.00 | Supply, installing, testing and commissioning of CPRI approved LT Control panel, outdoor type, double door, pedastal mounted, of suitable size , IP-54, having independent compartment for bus bar, incoming feeder and each out going feeder, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, mounted on 65mm x 65mm x 5mm iron angle frame height 45cm from PCC bedding suitable for 3 Phase 415 Volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 200 Amps rating for 3 Phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeveless as per colour code, supported on epoxy insulators - 01 set incl necessary copper cables of suitable size for MCCBs/MCBs/change over switch/inter connections, common earth bus bar of GI strip of size 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour mounting the panel on ground/floor with PCC (1:3:6) bedding upto a height of 45cm above ground level, complete all as approved and comprising as under:- | 1 | Each Job | 2,34,338 ₹2,34,338 Lowest | 2,50,000 ₹2,50,000 | 2,75,000 ₹2,75,000 |
| 2.01(a) MCCB 4 Pole,200 Amps, 35 KA, 415 Volt - 01 No (Incoming) (b) MCCB 4 pole, 80 Amps, 16 KA, 415 Volt-02 No (Outgoing) (c) Copper bus bar 300 Amps for 3 phase & neutral - 1 Set. (d) Digital Voltmeter 0-500 V with selector switch -01 No (e) Digital Ammeter 0-500 A with CTs and selector switch -01 No (e) LED type indicator lamps (R,Y,B) - 01 Set (f) star delta starter fully automatic ,fully automatic phase sequence corrector to correct input,reverse phase and also protect aganist single phasing voltage unbalancing, low/ high voltage with time delay 4 to 7 second and automatic digital timer switch with automaticcally on/off the motor starter upto 50 HPas per time setting -02 Nos | ||||||
| 3.00 | Supply and installing of size 150mm x50mmx6mm thick of perforated painted with powder coated MS cable tray with perforation not more than 17.5 % in convinient section ,joined with connectors suspended from ceiling with ms suspenders, nuts bolts , fixed on wall /floor all as specified and directed . | 20 | RM | 369 ₹7,380 | 150 ₹3,000 Lowest | 383 ₹7,660 |
| 4.00 | Unsheated stranded copper conducter cable size 16 sqmm single core 1100 Volts as in connections to MCCB,staters,motor etc connection to be made with cable terminal lugs and GI screws ,complete all as specified and directed. | 70 | RM | 338 ₹23,660 | 200 ₹14,000 Lowest | 349 ₹24,430 |
| 5.00Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying for laying GI tubing /UG cable/foundation of Pole etc and getting out in following type of soil complete all as specified and as directed. | ||||||
| 5.01 | (a) Soft /loose soil | 6.75 | Cum | 249 ₹1,680.75 | 100 ₹675 Lowest | 259 ₹1,748.25 |
| 6.00 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick excavated soft/loose soil in trenches after the pipe have been laid and tested complete all as specified and directed by Engineer-in-charge. | 5.4 | Cum | 49 ₹264.6 Lowest | 190 ₹1,026 | 59 ₹318.6 |
| 7.00 | Removal excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. | 1.35 | Cum | 49 ₹66.15 Lowest | 80 ₹108 | 59 ₹79.65 |
| 8.00 | M&L sand filling in trenches for cushioning of UG cable 8 cm before laying of cable and 15 cm after laying of cable including compacting after filling complete all as specified and directed.
Note : Only punned thickness shall be measured and paid. | 2.43 | Cum | 349 ₹848.07 | 120 ₹291.6 Lowest | 359 ₹872.37 |
Tender Value
₹19.3 L
EMD Value
₹38,680
Closing Date
22 Jul 2026, 6:00 pmClosed
GE SAMBA
GE SAMBA PIN 184121
PROVN OF CERTAIN REV WORKS AND MINOR WORKS UNDER GE SAMBA AT MIL STN SAMBA
2026_MES_774321_1
8166/GE/SMB/T-38/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE SAMBA
Class E Cat b i and c i
8 documents required · 8 mandatory
₹500
GE SAMBA
₹38,680
Yes
6 Aug 2026
23 Jun 2026
24 Jul 2026
23 Jun 2026
22 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,installation ,testing of horizontal centrifugal multistage pumping set electric driven 2940 RPM with CI Impeller and steel shaft having discharge 5.3 LPSat 350 MTR Head coupled with squirrel cage induction motor of capacity not less than 50HP ,415 AC, 3 phase 50 HZ, mounted on common MS base plate ( Factory assemblled ) and foundation of the pump set including PCC foundation ,MS bolts with nots and anti viberation pads with stainless steel glycerin pressure gauge type complete al as specified and directed .
Note : Rates for any modification in suction and discharge by providing MS pipe , connecting suction and discharge line to the pump set and making new PCC foundation for installation of pumping set and other misc work realted to pumping set shall be included in the quoted rate. | 2 | Each | 100 | ₹200 |
| 2 | Supply, installing, testing and commissioning of CPRI approved LT Control panel, outdoor type, double door, pedastal mounted, of suitable size , IP-54, having independent compartment for bus bar, incoming feeder and each out going feeder, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, mounted on 65mm x 65mm x 5mm iron angle frame height 45cm from PCC bedding suitable for 3 Phase 415 Volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 200 Amps rating for 3 Phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeveless as per colour code, supported on epoxy insulators - 01 set incl necessary copper cables of suitable size for MCCBs/MCBs/change over switch/inter connections, common earth bus bar of GI strip of size 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour mounting the panel on ground/floor with PCC (1:3:6) bedding upto a height of 45cm above ground level, complete all as approved and comprising as under:- | 1 | Each Job | 102 | ₹102 |
| 2.01 | (a) MCCB 4 Pole,200 Amps, 35 KA, 415 Volt - 01 No (Incoming)
(b) MCCB 4 pole, 80 Amps, 16 KA, 415 Volt-02 No (Outgoing)
(c) Copper bus bar 300 Amps for 3 phase & neutral - 1 Set.
(d) Digital Voltmeter 0-500 V with selector switch -01 No
(e) Digital Ammeter 0-500 A with CTs and selector switch -01 No
(e) LED type indicator lamps (R,Y,B) - 01 Set
(f) star delta starter fully automatic ,fully automatic phase sequence corrector to correct input,reverse phase and also protect aganist single phasing voltage unbalancing, low/ high voltage with time delay 4 to 7 second and automatic digital timer switch with automaticcally on/off the motor starter upto 50 HPas per time setting -02 Nos | - | - | - | - |
| 3 | Supply and installing of size 150mm x50mmx6mm thick of perforated painted with powder coated MS cable tray with perforation not more than 17.5 % in convinient section ,joined with connectors suspended from ceiling with ms suspenders, nuts bolts , fixed on wall /floor all as specified and directed . | 20 | RM | 104 | ₹2,080 |
| 4 | Unsheated stranded copper conducter cable size 16 sqmm single core 1100 Volts as in connections to MCCB,staters,motor etc connection to be made with cable terminal lugs and GI screws ,complete all as specified and directed. | 70 | RM | 104 | ₹7,280 |
| 5Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying for laying GI tubing /UG cable/foundation of Pole etc and getting out in following type of soil complete all as specified and as directed. | |||||
| 5.01 | (a) Soft /loose soil | 6.75 | Cum | 104 | ₹702 |
| 6 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick excavated soft/loose soil in trenches after the pipe have been laid and tested complete all as specified and directed by Engineer-in-charge. | 5.4 | Cum | 108 | ₹583.2 |
| 7 | Removal excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. | 1.35 | Cum | 110 | ₹148.5 |
| 8 | M&L sand filling in trenches for cushioning of UG cable 8 cm before laying of cable and 15 cm after laying of cable including compacting after filling complete all as specified and directed.
Note : Only punned thickness shall be measured and paid. | 2.43 | Cum | 111 | ₹269.73 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
TenderDocumentsT38.pdf
Tender Documents • 1.01 MB
BOQ_867053.xls
BOQ • 1.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .