Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹126.0 CrAccepted-AOC H NO 8 2 2 1 FLAT NO 203 SITARAMA APARTMENT OPP AXIS BANK PANJAGUTTA HYDERABAD 500 082 | HYDERABAD | TELANGANA | 500082 | ₹126.0 Cr Quoted ₹126.1 Cr | L1 | Accepted-AOC Accepted Amount after deducting Sch of Credit of Rs. 213970.00 |
| 2 | L2₹147.1 CrRejected-Finance | ₹147.1 Cr | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹159.6 CrRejected-Finance | ₹159.6 Cr | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹187.8 CrRejected-Finance | ₹187.8 Cr | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹212.3 CrRejected-Finance | ₹212.3 Cr | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹171.7 Cr
EMD Value
₹15 L
Closing Date
14 Feb 2025, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
Chief Engineer (Navy) Visakhapatnam Station Road Visakhapatnam-530 004
PROVISION OF DEFICIENT SINGLE LIVING ACCOMMODATION INCLUDING DINING HALLS AND COOK HOUSES FOR SAILORS OF NAVAL UNITS AT VISAKHAPATNAM
2024_MES_688089_1
85436
Open Tender
Construction Works
990 days
Visakhapatnam
As per NIT
14 documents required · 14 mandatory
₹3,000
Garrison Engineer Project Navy Visakhapatnam
₹15 L
Yes
2 Apr 2025
11 Dec 2024
21 Feb 2025
11 Dec 2024
14 Feb 2025
24 Jan 2025
23 Dec 2024 - 30 Dec 2024
Amount
SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XIV: Note: Schedule 'A' Part-I to Part-XV are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lump Sum price worked out by the contractor for 'Buildings & Structures', as listed in Schedule 'A' Part-I.
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-II.
Lump Sum price worked out by the contractor for 'Pile Foundation', as listed in Schedule 'A' Part-III.
Lump Sum price worked out by the contractor for 'Internal Water Supply', as listed in Schedule 'A' Part-IV.
Lump Sum price worked out by the contractor for 'Internal Electrification', as listed in Schedule 'A' Part-V.
Lump Sum price worked out by the contractor for 'External Water Supply', as listed in Schedule 'A' Part-VI.
Lump Sum price worked out by the contractor for 'External Electrification', as listed in Schedule 'A' Part-VII.
Lump Sum price worked out by the contractor for 'Area Drainage', as listed in Schedule 'A' Part-VIII.
Lump Sum price worked out by the contractor for 'Sewage Disposal', as listed in Schedule 'A' Part-IX.
Lump Sum price worked out by the contractor for 'Road/Path/Culvert', as listed in Schedule 'A' Part-X.
Lump Sum price worked out by the contractor for 'Lightening Protection', as listed in Schedule 'A' Part-XI.
Lump Sum price worked out by the contractor for 'Solar Water Heater', as listed in Schedule 'A' Part-XII.
Lump Sum price worked out by the contractor for 'Fire Fighting', as listed in Schedule 'A' Part-XIII.
Lump Sum price worked out by the contractor for 'Fire Alarm & Detection System', as listed in Schedule 'A' Part-XIV.
SCHEDULE 'A' PART-XV: (MISCELLANEOUS ITEMS):
PILE FOUNDATION:
Boring for bored cast-in-situ piles 900mm dia. in any type of soil/clay/ soft rock except hard rock/fractured rock using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed by the Engineer-in-Charge.
Boring for 900mm dia. bored cast in situ piles in hard rock and getting out and disposal of spoil out side MD land using DMC method (Direct Mud Circulation) complete all as specified and shown on drawings and as directed by the Engineer-in-Charge.
Boring for bored cast-in-situ piles 600mm dia. in any type of soil/clay/ soft rock except hard rock/fractured rock using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed by the Engineer-in-Charge.
Boring for 600mm dia. bored cast in situ piles in hard rock and getting out and disposal of spoil out side MD land using DMC method (Direct Mud Circulation) complete all as specified and shown on drawings and as directed by the Engineer-in-Charge.
Chipping of laitance concrete in piles above cut off level up to a maximum of 1m from cut of level and disposal to out side MD land and depositing where directed complete all as specified and as directed by the Engineer-in-Charge.
Carrying out initial compressive load test on 900mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed by the Engineer-in-Charge.
Carrying out initial compressive load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed by the Engineer-in-Charge.
Carrying out routine compressive load test on 900mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed by the Engineer-in-Charge.
Carrying out routine compressive load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed by the Engineer-in-Charge.
Carrying out routine lateral load test on 900mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed by the Engineer-in-Charge.
Carrying out routine lateral load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed by the Engineer-in-Charge.
Carrying out pull out test on cast in situ pile 900mm dia. as per IS complete all as specified and as directed by the Engineer-in-Charge.
Carrying out pull out test on cast in situ pile 600mm dia. as per IS complete all as specified and as directed by the Engineer-in-Charge.
Carrying out low strain integrity test on cast in situ piles 900mm dia. including analysing the result as per ASTM D 5882 complete all as specified and as directed by the Engineer-in-Charge.
Carrying out low strain integrity test on cast in situ piles 600mm dia. including analysing the result as per ASTM D 5882 complete all as specified and as directed by the Engineer-in-Charge. Note fot Item Nos.20 to 29: Test results shall be approved by the CWE. The GE shall intimate CWE before commencing the load test and the test shall be carried out in presence of the authorised representative detailed by the CWE.
INTERNAL ELECTRIFICATION:
Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly, for One light/bell point controlled by one no. one way switch or One fan (ceiling fan/exhaust fan/wall mounted) point controlled by one switch or one 3 pin socket outlet 5 Amps on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No.30 here-in-before but for One light point controlled by two nos. two way switches on independent board.
All as per item No.30 here-in-before but for one 3 pin socket outlet 5 Amps on same board.
All as per item No.30 here-in-before but for one 3 pin socket outlet 5 Amps on independent board with 2.5 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuity.
All as per item No.30 here-in-before but for one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity.
Point wiring for flame proof light fittings with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including concealed stove enamelled steel metallic conduit and metal conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly, for One light/bell point controlled by one no. one way switch or One fan (ceiling fan/exhaust fan/wall mounted) point controlled by one switch or one 3 pin socket outlet 5 Amps on independent board complete all as specified and as directed by the Engineer-in-Charge.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 4 Sq.mm. cable and one run of 4 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with four runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 25mm dia. with accessories complete with four runs of 10 Sq.mm. cable and one run of 10 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 25mm dia. with accessories complete with four runs of 16 Sq.mm. cable and one run of 16 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge. Note for Item Nos.36 to 40: Two/Four (As specified) runs of cable, one run of earth wire and one run of conduit will be measured as one unit.
S&F switch flame Proof rotary type with termination box in LM6, 6/16A, single pole 250 Volts complete all as specified and as directed by the Engineer-in-Charge.
S&F concealed in wall vertical MCCB DB double door type, TPN 4 way, 415 Volts, 50 Hz, IP 43 protection with 200 Amps rated bus bar including provision for fixing MCCB FP 63 Amps as incommer and out going circuits MCB SP/TP complete, filling empty way with blanking plates complete all as spcified and as directed by the Engineer-in-Charge. Note: MCCB & MCBs shall be measured and paid separately.
S&F LED adore lamp 9 Watts, 240 Volts AC, B22 type, CDS 5 star complete all as specified and as directed by the Engineer-in-Charge.
S&F energy efficient LED tube light fitting (Mirror optic) with tube 5 Watt, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI>80, PF>0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc. with extruded polycarbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.
S&F energy efficient LED tube light fitting with tube 9 Watts, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.
S&F energy efficient LED tube light fitting with tube 20 Watts, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.
S&F energy efficient LED tube light fitting with tube 2x20 Watts, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.
S&F LED building security light fitting with tube 30 Watt new generation energy saving & environmental frindly, long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.5 Sq.mm. copper conductor cable up to connector including 1.5m long GI tubing light grade of 32mm dia. bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F LED flame proof tube light fitting 1x16 Watt, IP 65 protection with die cast aluminium housing with heat resistance, toughened glass with LED tube light fixtures, driver, holders, connections etc. complete with accessories powered and including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.
S&F ceiling fan complete with blades, down rods, and accessories, 230 Volts, 1200mm sweep, minimum air delivery 210 CFM with service value 6.0 BEE five star rated with brushless direct current motor (BLDC) with and including flexible copper wire 1 Sq.mm. form ceiling rose to connector of ceiling fan complete all as specified and as directed complete all as specified and as directed by the Engineer-in-Charge.
S&F exhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, 1200 RPM copper winding of sweep 250mm, fixed on wall including making opening, fixing and making good the distrubed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 Sq.mm. twin core flexible wire complete all as specified and as directed by the Engineer-in-Charge.
S&F exhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, 1200 RPM copper winding of sweep 300mm, fixed on wall including making opening, fixing and making good the distrubed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 Sq.mm. twin core flexible wire complete all as specified and as directed by the Engineer-in-Charge.
S&F flame proof 100mm dia. junction box 4 way sutaible for 20/25mm dia. ERW MS coundit complete certified CIMFR for gas group I, II A & II B for Zone I & II complete all as specified and as directed by the Engineer-in-Charge.
S&F flame proof stainless steel hose conduit pipe 300mm long complete all as specified and as directed by the Engineer-in-Charge.
EXTERNAL WATER SUPPLY:
S&F foot Valve, cast iron body, 100mm bore with flanged ends of any pattern with by pass arrangement and confirming to IS-4038, ISI marked including all Joints with rubber gasket and jointing materials, bolts, nuts, washer complete all as specified and as directed by the Engineer-in-Charge.
M&L brick masonry valve chamber of size 1000x1000x1000mm (Inner dimensions) comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200mm thick PCC 1:4:8 type D2 foundation, brick work in CM 1:6, plastring internal surface 15mm tick in CM 1:4, PCC 1:3:6 type C1 couping, 50x50x6mm angle iron, 3mm thick MS plate cover complete with locking arrangement painting to steel and iron surface with two coat of synthetic enamel paint over one coat of zinc chrome primer complete all as shown on drawing and as specified and as directed by the Engineer-in-Charge.
Supply, install, testing and commissioning of horizontal centrifugal closed couple pump set having discharge 13000 LPM at 75m Head with 40 HP TEFC squirrel cage induction motor insulation class F, inlet/outlet of 65x50mm and bronze impeller having motor efficiency of IE3 and mechanical seal including PCC foundation complete all as specified and as directed by the Engineer-in-Charge.
Fabricate, supply, Install, test and commission LT panel board made out of CRCA sheet 2mm thick Indoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, danger notice plate, stickering of switcher gear about termination of switch gear and nuts & bolts etc. made of rust proof material all as per IS 8623 including aluminium bus bar with heat proof colour code, insulators suitable for 3 Phase and four wire LT AC, 50 Hz, 415 Volts, 200 Amps capacity complete with powder coating including necessary internal electric connections as required with and inclusive of following items complete all as specified and as directed by the Engineer-in-Charge: INCOMING: (a) MCCB, 3 Pole, 25 kA, 100 Amps rated, LT 440 Volts, 4 wire, 50 Hz, adjustable type complete with overload protection, no-volt thermal based release-01 No. OUTGOING: (a) MCCB, 4 Pole, 16 kA, 63 Amp, 415 Volts, 50 Hz-03 Nos. (02 Nos. for Pumps & 01 No. Spare) (b) MCB TPN 16 Amps, C-Curve, 50 Hz, 415 Volts-01 No. (For pump house building) (c) Standard Automatic Star Delta starter for 3 Phase pump set of minimum capacity 40 HP with protection-02 Nos. (d) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases-01 Set of 03 (e) Intelligent Panel Meter to measure voltage, current, frequency, power factor, kWH, etc. with all connected CTs of main incommer.
M&L earth continuity conductor or main earthing lead made of galvanised iron strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI pipe for earthing etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L for cutting existing CI/DI pipe 200mm dia. for alterations or additions necessarily done in position with out taking down and inserting DI 'TEE' of size 200x200x300mm for tapping complete all as specified and as directed by the Engineer-in-Charge.
EXTERNAL ELECTRIFICATION:
Supply, installation, testing and commissioning of outdoor type 11 KV Compact Sub Station with non-extensible manually operated 1 No SF6 insulated VCB with metering cubicle/relays/protections, HT cable/bus bar, 1 No. transformer 1000 KVA, 11 KV/433 V, oil filled & associated LT side having of ACB 1600 Amps 50 KA 02 Nos. (One for main LT panel and one spare) complying the following specifications complete all as specified and as directed by the Engineer-in-Charge: HT Side: 11 kV, 630 Amps, 21 kA/1 sec, non-extensible breaker in min 2.5mm stainless non ferrite and non magnetic robotically welded steel tank with copper bus bar, compact switchgear consisting of one no. Fixed manual Vacuum Circuit Breakers (VCB) with direct incoming connection in SF6 insulated sealed for life gas tank with IP67 degree of protection with integrated current protection which shall be connected to HV side of above transformer using 1C x 3R x 95 Sq.mm. Cable with site replaceable bushings along with air insulated metering module for bus side metering. The breaker shall have self-powered microprocessor based numerical over current and earth fault relay protection with charged open/closing mechanism, on/off indicators, mechanical operation counters etc. Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Al. unarmoured XLPE Cable. (a) Relay shall be self-powered of Ashida/C&S or equivalent make (50, 50 N, 51, 51 N) with RS485 communication port-01 No. (b) Protection CT shall be 80/1A 2.5 VA 5P10 (Make: ECS/Ericon/Bharti Electricals or equivalent)-01 Set
(c) Standard Manometer (SF6 Gas Pressure Indicator)-01 No. (d) Fault Passage Indicator (FPI) for incoming only-01 No. (e) Voltage presence indicator (VPIS) for incoming healthy indications-01 Set (f) Manual push button for breaker ON/OFF-01 Set (g) Mechanical Indication for Breaker & LBS ON/OFF/EARTHED-03 Nos. (h) Operating handle-01 No. (j) All incoming modules of the breaker shall be capable for cable termination of 3 Core x 300 Sq.mm. aluminium conductor XLPE cable TRANSFORMER: 1000 KVA 11 kV/433 V Dyn 11 Oil Filled (ONAN) Hermetically sealed distribution transformer with corrugated radiator wall (without conservator type design) & Top mounted normal porcelain bushing for HT, LT with Off circuit tap changer (Make: Danish/ABB or equivalent approved vendors) (a) Off Circuit Tap Changer (OCTC), Tapping range +5% to -5% in a steps of 2.5% (4 Steps/5 Positions) (b) Temporary Rise shall be 40/45 Degrees C for Oil/Winding resp. Over an ambient of 50 Degrees C Temp (c) Insulation Class: A (d) Losses (Subject to IS 1180 Efficiency Level 2/Star 2 as per latest Amendment 4) Maximum Total Loss @ 50% Loading: 2620 W and Maximum Total Loss at 100% Loading: 7000 W. (e) % Impedance (%Z) shall be 5.00% (Subject to IS Tol.) (f) Rating & Diagram (R&D) Plate (Fitted on Transformer) (g) Oil Temp. Indicator (OTI) with alarm and trip contact
(h) Winding Temporary Indicator (WTI) with alarm and trip contact (j) Rated temp Class of Transformer Compartment K10 up to 1000 kVA LT Side: LT PANEL-1600 Amps aluminium bus bar (100% for Phase & 50% for Neutrals) Current density 1 Amp/Sq.mm., having IP2X, fabrication using 1.5/2mm CRCA sheet steel complete with internal wiring consisting of following: (a) INCOMER From transformer (b) 1600 Amps 4P 50Hz 50 KA Fixed Manual Type Air Circuit Breaker (ACB) with microprocessor based Ekip Dip release for Overload (O/L), Short circuit (S/C) & Earth Fault (E/F) protection-02 Nos. (c) LED type Indicating Lamp-RYB, ON-OFF-TRIP (Make: TEKNIK/ BINAY/ ESSEN DEINKI)-01 Set (d) LT side metering CT 1600 A/5 A, 5 VA, Cl:1.0 (G&M/NEWTEK or Equivalent)-01 Set (e) Digital Multifunction Meter (MFM), CL-1.0 Accuracy with RS 485 Port (Make: CONZERVE/ RISHABH/ ELMEASURE/SECURE or Equivalent)-01 No. OUTDOOR ENCLOSURE: Outdoor type enclosure having construction of Galvanised Sheet Steel having 1.5mm thickness for Non-load bearing & 2 mm for Load bearing partition sheets & Door with HRCA 4 mm base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (Colour Light grey and dark grey). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp
Fabricate, supply, Install, test and commission main LT panel made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, stickering of switcher gear about termination of switch gear and nuts & bolts etc. made of rust proof material all as per IS 8623, including tinned copper bus bar rated with insulators suitable for 3 Phase and four wire LT AC, 50 Hz, 415 Volts, 2400 Amps capacity complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed by the Engineer-in-Charge: Incoming: Air circuit breaker 1600 Amps, 50 kA, MDO, 4 Pole, microprocessor release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. - 1 No. Outgoing: (a) MCCB 500 Amps, 35 kA, 4 Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection- 03 Nos. (BBT-02 Nos. & 01 No. Spare) (b) MCCB 400 Amps, 35 kA, 4 Pole suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection- 03 Nos. (01 No. each for APFC & AMF & 01 No. Spare) (c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH etc. with all connected CTs. (d) LED indicating lamps with colour Red, Yellow, Blue of 03 Sets.
Fabricate, supply, Install, test and commission LT Distribution Panel board made out of CRCA sheet 3.15mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, stickering of switchgear about termination of switchgear, cable connector for connecting multi cables located in cable chamber terminated form the switchgear and nuts & bolts etc. made of rust proof material all as per IS 8623 including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 Volts, 1300 Amps capacity complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed by the Engineer-in-Charge: Incoming: (a) MCCB 400 Amps, 35 kA, 4 Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection-01 No. Outgoing: (a) MCCB 200 Amps, 35 kA, 4 Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection-02 Nos. (01 No. for FF Pump House & 01 No. Spare). (b) MCCB, 3 Pole, 25 kA, 100 Amps rated, LT 440 Volts, 4 wire, 50 Hz, adjustable type complete with overload protection, no-volt thermal based release- 03 Nos. (01 No. for STP & Fresh Water Pump each & 01 No. Spare). (c) MCCB AC 3 Phase 415 Volts, 50 Hz, 4 Pole, 40 Amps capacity 16 kA with adjustable type thermal and magnetic setting relays-12 Nos. (For Common area-02 Nos., Street Light-01 No., Lift 08 Nos. and Spare 01 No.). (d) Intelligent Panel meter to measure voltage, current, frequency, power factor etc. with all connected CTs (e) LED indicating lamps with colour Red, Yellow, Blue-01 Sets
Supply, installation, testing and commissioning of APFC panel with MD-XL capacitor and MCCB as incomer (Auto/ Manual option) with 400 KVAR with 8 steps (2x100 + 2x50 + 4x25 KVAR) complete all as specified and as directed by the Engineer-in-Charge.
S&F the following components for Compact Air Insulated bus bar trunking rising main system, aluminium conductor 630 Amp 40 KA (3 Phases + 100 % Neutral + Integral Ground Earth) 4 Nos. aluminium bus bars and 2 Nos. of aluminium external earthing strips of 32x6mm size, system voltage 415 Volt, AC supply, rated frequency 50/60 Hz, with made of 1.6mm thick sheet GI enclosure duly painted with powder coating (RAL-7032), Indoor ( IP 54 ), with provision of taping at every floors, end cover, vertical support, flange end, brackets, spring hangers, braided flexible, suspension bracket etc. complete all as specified and as directed by the Engineer-in-Charge:
630 Amps, 4 Pole, 40 kA, IP 54 Aluminium Compact Air Insulated Type Rising Main
630 Amps End Feed Unit with 36 KA/4 Pole of 630 Amps MCCB
63 Amps plugin box with 63 Amps 15 KA 4 Pole MCCB
125 Amps plugin box with 125 Amps 36 KA 4 Pole MCCB
S&F LED street light fitting 72 Watt, 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified and as directed by the Engineer-in-Charge.
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, combi-climate cable glands of IP 66/IP 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, ‘C’ Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed by the Engineer-in-Charge;
3½ core 400 Sq.mm.
3½ core 300 Sq.mm.
3½ core 240 Sq.mm.
3½ core 120 Sq.mm.
3½ core 50 Sq.mm.
3½ core 35 Sq.mm.
3½ core 25 Sq.mm.
4 core 16 Sq.mm.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, of sixe 3 core 240 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC insulated PVC sheathed flexible cable LT 1100 Volts grade with copper conductor of size 3 core 1.5 Sq.mm. multi stranded conductor drawn through PVC pipe with clamping materials complete all as specified and as directed by the Engineer-in-Charge.
M&L earth continuity conductor or main earthing lead made of galvanised iron strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI pipe for earthing etc. complete all as specified and as directed by the Engineer-in-Charge.
Boring of holes under road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe 150mm dia. suitable for 0.4 mpa working pressure complete all as specified and as directed by the Engineer-in-Charge.
AREA DRAINAGE:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed by the Engineer-in-Charge.
M&L pre-cast RCC M-30 as in factory made cover slabs, set in cement mortar (1:4) including use and waste of form work complete all as specified and as directed by the Engineer-in-Charge.
SEWAGE DISPOSAL:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed by the Engineer-in-Charge.
M&L for pre-cast SFRC 560mmx560mm EHD-35 Extra Heavy Duty (Square) manhole cover slabs conforming to IS 12592-2002, set in cement mortar (1:4) complete all as specified and as directed by the Engineer-in-Charge.
ROAD/PATH/CULVERT:
M&L granular sub base (GSB) with grading V of 200mm thick compacted thickness (Laid in two layers of 100mm each, compacted seperately) confirming to grading as specified, spread, rolled & consolidated to required gradient and camber complete using necessary mechanical paver/grader & vibratory soil compacter of capacity 8-10 Ton complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Pavement shall be made for solid quantity arrived after consolidation. 2. Compaction of granular sub base filling shall be carried out under optimum moisture condition to achieve 98.50% modified density. 3. Curing shall be carried out as per IRC recommendations. 4. Before execution of this item the approved material obtained from outside MD land shall be tested/Checked for suitability to use. 5. Contractor shall use vibratory earth compactor in lieu of power roller to achieve 98.50% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. 6. GSB shall be as per MORTH specification as detailed in particular specification.
LIGHTNING PROTECTION:
S&F single pointed air terminal aluminium rod 12mm dia. 300mm long with aluminium box plate of size of 125x125x10mm fixed over porcelain insulator and fixed on roof top complete including 40mm dia. medium grade MS pipe 300mm long and including necessary fasteners fixed for lighting protection with necessary connections to earthing etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F horizontal roof conductor and down conductor of size 25x3.15mm aluminium strip fixed to walls/columns/projections/roof including porcelain blocks/DMC insulator spaced at 1m interval complete all as specified and as directed by the Engineer-in-Charge.
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F galvanised iron strip of 32x6mm size with saddles and fixing screws etc. for wall conductors connected with equipment and above ground (Proper insulation should be provided between the strip and walls) complete all as specified and as directed by the Engineer-in-Charge.
AVIATION LIGHT:
S&F aviation obstruction light LED type filament-less bulb with 10 Watt bulb including standard fixing arrangements complete all as specified and as directed by the Engineer-in-Charge.
S&F time switches 250 Volts single phase, 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed by the Engineer-in-Charge.
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, combi-climate cable glands of IP 66/IP 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, ‘C’ Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. complete all as specified and directed.
S&F PVC insulated PVC sheathed armoured cable LT 1100 Volts grade with copper conductor of size 3 core 1.5 Sq.mm. multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps, spacers, bolts, nuts etc. complete all as specified and as directed by the Engineer-in-Charge.
HOT WATER SUPPLY:
S&F electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW capacity 25 Litres, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece branded with ISI mark etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW capacity 50 Litres, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece branded with ISI mark etc. complete all as specified and as directed by the Engineer-in-Charge.
TV & TELEPHONE:
S&F rigid non metallic PVC conduit of 25mm dia. (external) concealed in wall, exclusive of junction box but inclussive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers lock nuts, saddles, pipe hooks etc. including GI wire for wiring of TV/telephone cable complete all as spcified and as directed by the Engineer-in-Charge.
S&F telephone/communication network sockets (Jack type) RJ 11-1 with shutter 1 module with cover plate complete with all acessories complete all as specified and as directed by the Engineer-in-Charge.
S&F TV co-axial socket 1 module complete all as specified and as directed by the Engineer-in-Charge.
S&F factory fabricated GI metal flush boxes suitable for 1-2 module complete all as specified and as directed by the Engineer-in-Charge.
COOLING APPLIANCES:
S&F refrigerator, electric driven (single phase), capacity 380 Litres, double door with smart inverter compressor BEE 3 star rated complete with all acessories complete all as specified and as directed by the Engineer-in-Charge.
S&F deep freezer glass top 405/425ltrs capacity having double door single phase 240 Volt, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
S&F S&F voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 2 KVA complete all as specified and as directed by the Engineer-in-Charge.
WATER COOLER:
S&F water cooler electric driven (single phase) having approx storage capacity of 120 Litres and nominal cooling capacity of 60 Litre per hour complete all as specified and as directed by the Engineer-in-Charge.
S&F S&F voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 2 KVA complete all as specified and as directed by the Engineer-in-Charge.
ELECTRIC CHIMNEY:
Design, supply, fabricating, installation, testing and commissioning of electric chimney for kitchen, of size 60x60x30 inches, stainless steel sheet with oil filter 20 gauge sheet 304 GI ducting, angle frame, threading rods, nuts, bolts etc. along with damper suitable blower with starter suitable 15 stoves and panelling for all items, fixing of outer GI sheet ducting box type from bottom to top with 20/22 gauge GI sheet, top bend corner with blower motor with 3 HP XL fan 960 RPM, 3 Phase Automatic running motor with starter, connected to GI sheet ducting complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable PVC insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3 core 10 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
FIRE FIGHTING SYSTEM:
M&L laying of ductile iron pipe 150mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed by the Engineer-in-Charge.
S&F MS flanged pipe 200mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge.
S&F MS flanged pipe 150mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge.
S&F MS flanged pipe 100mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge.
S&F MS flanged pipe 80mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge.
S&F MS flanged pipe 40mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge.
S&F MS flanged pipe 25mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed by the Engineer-in-Charge.
S&F flanged end lift type foot valve 80mm dia. with brass strainer, suitable flanges, nuts, bolts, gaskets etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F flanged end lift type foot valve 150mm dia. with brass strainer, suitable flanges, nuts, bolts, gaskets etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F MS cabinet made out of 3mm thick MS sheet with front door having 3mm thick glass panels and locking arrangement suitably mounted on wall including painting with two coats of postal red synthetic enamel paint over one coat of zinc chrome primer complete all as specified and as directed by the Engineer-in-Charge.
S&F air cushioning tank (Air vessel) 300mm dia. and 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia. stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete fixed on top of suitable flange hydrant line complete all as specified and as directed by the Engineer-in-Charge.
S&F control panel for operating Electrical driven Booster terrace pump up to 20 HP rated including necessary MCCB, starter, multifunction meter, CT & control wiring complete all as specified and as directed by the Engineer-in-Charge.
S&F LED EXIT light double sided with battery backup up to 2 hours complete all as specified and as directed by the Engineer-in-Charge.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, of sixe 4 core 16 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
M&L earth continuity conductor or main earthing lead made of galvanised iron strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI pipe for earthing etc. complete all as specified and as directed by the Engineer-in-Charge.
Design, supply, fabricating, installation, testing and commissioning of fixed type wet chemical fire suppression system at 02 Nos. kitchen/cook house in 1st floor for Approx. 5x1 mtr. size kitchen hood including complete automatic fire detection system comprising of pressure switch, heat detection sensor, manual release switch, discharge nozzle, wet chemical cylinders, alarm, exit sign, fire cable, hooter, control panel, suitable size heavy duty ms pipe as per approved design etc. complete all as specified and as directed by the Engineer-in-Charge. Note: The contractor shall submit the design/calculations and drawings of system and shall get the approval of the Accepting Officer before placing order.
FIRE ALARM DETECTION SYSTEM:
S&F PVC insulated PVC sheathed armoured cable LT 1100 Volts grade with copper conductor of size 2 core 1.5 Sq.mm. multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps, spacers, bolts, nuts etc. complete all as specified and as directed by the Engineer-in-Charge.
PA SYSTEM:
Supply, installation, testing and commissioning of IP based Digital Public Address and Emergency Sound System Controller certified to International standards of Emergency Sound System EN 54 and ISO 7240 16, marked for CE and compliant with the RoHS directive, fully IP-network based and all system devices communicating via IP, using an audio over IP (AoIP) protocol that supports standards AES67 for audio and using AES128 for control with optional encryption and authentication to prevent unauthorized access, misuse and modification of data, capable of receiving Dante and AES67 audio streams, the audio part capable of supporting Layer 3 connections via routers between subnets with latency of less than 10ms and synchronized outputs, the control data part being guaranteed by Transmission Control Protocol (TCP) Layer 4, the system capable of supporting >100 simultaneous channels for music routing and making calls, including the system based on a single system controller supporting at least 120 system devices and 500 zones, and the system controller dynamically assign the network audio channels for audio routing between system devices across multiple subnets, the system controller having dual power supply inputs and power supplies and keeping an internal log of fault events and call events, with the system controller providing a secure TCP/IP open interface for remote control and diagnostics and the front-panel LED indications for the status of power supplies and the presence of faults in the system up to 2000 faults and also providing an additional software monitoring and fault reporting features, having the provision of 'Hot Redundancy' for standby controller automatically taking over the faulty duty controller in case of failure of working controller complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of the IP based desktop call station for PA system operation certified for EN 54 16 and ISO 7240 16, marked for CE and be compliant with the RoHS directive, with Desktop housing with gooseneck microphone, 4.3" full colour capacitive touch display, including provision of control and routing of live speech calls, stored messages and music with volume control per zone, graphical user interface for optimum user guidance and feedback, status and fault indicators for voice alarm purposes and Dual Audio over IP network ports for redundant network, audio over IP complying AES 67 standard for audio and AES 70 for control with optional encryption and authentication to prevent unauthorized access, misuse and modification of data and capable of receiving Power over Ethernet (PoE) via either one or both network connections complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of the IP based Digital Class-D multi-channel amplifier 600 W each with 8 channels, with the adaptation of the maximum output power of each amplifier channel to its connected loudspeaker load, with free assignable output power per channel, EN 54 certified and ISO 7240 16, marked for CE and compliant with the RoHS directive, having a built-in independent spare amplifier channel for automatic failover, providing an interface for control data and multi-channel digital audio over IP using dual Ethernet ports for redundant network connection, supporting RSTP and loop-through cabling, with automatic failover to an analog lifeline input, having dual power supply inputs and power supplies and all amplifier channels having independent A/B zone outputs with support for class-A loudspeaker loops, all amplifier channels being capable of supervise the integrity of connected loud speaker lines without interruption of audio distribution, and providing front-panel LED status indications for the network link, ground fault, power supplies and audio channel, additional software monitoring and fault reporting features, Audio over IP, using the high quality digital audio interface, compatible with AES67 and AES 70 standards with optional encryption and authentication to prevent unauthorized access, misuse and modification of data using an uncompressed, high-definition digital audio format with 24-bit sample size and 48 kHz sample rate, also being digital signal processing on all amplifier channels, including equalization, limiting and delay, to optimize and tailor the sound in each loudspeaker zone complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of the 48 Volts DC power supply module containing a mains input with power factor correction and a 48 Volts output, with output current capability 5 Amps continuous and 7.5 Amps peak, power supply of DIN rail mountable with convection cooling and marked for UL and CE and compliant with the RoHS directive complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of the 24 Volts DC power supply module containing a mains input with power factor correction and a 48 Volts output, with output current capability 5 Amps continuous and 7.5 Amps peak, power supply of DIN rail mountable with convection cooling and marked for UL and CE and compliant with the RoHS directive complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of the compact device for loudspeaker end of line supervision having one connection with the end of the loudspeaker line to supervise its integrity, with the supervision reliability not depending upon the number of connected loudspeakers, with the supervision being inaudible and not interrupting the audio content (Using the low level high frequency pilot tone monitoring), certified for EN 54-16 and ISO 7240-16, marked for CE and be compliant with the RoHS directive complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of the 4 Watt False True Ceiling loudspeaker with a circular plastic grille, having excellent audio performance and being easy to install with its integral, IPx4 water protected from the front for installation in humid environments, with a back box for mounting speakers on true ceiling as a part of the speaker, with special treated paper cone, tested for operating at rated power for 100 hours in accordance with IEC268-5 Power Handling Capacity (PHC) standards complying with the following specifications complete all as specified and as directed by the Engineer-in-Charge: Rated Power: 4 Watts, Power Tapping: 4/2/1 Watt Effective frequency range (-10 dB): 85 Hz to 10KHz SPL at rated power (1 Khz at 1 m): 96 dB SPL at 1 Watt (1 Khz at 1 m): 91 dB Opening Angle 1 KHz/4 KHz (-6 dB): 180°/89° Rated Impedance: 2500 Ohms Dimensions (DxH): 164mmx64mm, Cut out: 142mm Operating temperature: -5° C to +55° C
Supply, installation, testing and commissioning of the 6 Watt general-purpose cabinet loudspeaker for indoor use, with the keyholes at the rear for quick and easy wall mounting, with the angled front baffle for the better sound in the listening area, with the cabinet in black or white, robust, solid MDF (Medium Density Fiber) board enclosures covered with a durable, easy-to-clean vinyl in white or black and ABS fronts covered with fine woven cloth in matching colour, tested for operation at rated power for 100 hours in accordance with IEC 268-5 Power Handling Capacity (PHC) standards complying with the following specifications complete all as specified and as directed by the Engineer-in-Charge: Rated Power: 6 Watt, Power Tapping: 6/3/1.5 Watt Effective frequency range (-10 dB): 150 Hz to 15 KHz SPL at rated power (1 Khz at 1 m): 101 dB SPL at 1w (1 Khz at 1 m): 90 dB Opening Angle Horizontal 1 KHz/4 KHz (-6 dB): 195°/95° Opening Angle Vertical 1 KHz/4 KHz (-6 dB): 70°/20° Rated Impedance: 833 Ohms Operating temperature: -5° C to +55° C
S&F PVC insulated shielded PVC FRLS sheathed blue in outer colour armoured speaker cable LT 1100 Volts grade with copper conductor of size 2 core, 1.5 Sq.mm. multi stranded conductor with clamping materials complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of 19 Equipment Rack, 42 U Made of mild steel for housing of all the equipment as described in all the PA System items with front lockable glass door, fan tray for cooling, caster wheel base, main panel with spike buster and individual fuse power supply unit including all the internal wiring/interconnections as required complete all as specified and as directed by the Engineer-in-Charge.
S&F CAT 5/6 cable complete all as specified and as directed by the Engineer-in-Charge.
S&F 8 Port POE switch complete all as specified and as directed by the Engineer-in-Charge.
DG SET:
Supply installation testing and commissioning of silent engine generating set with acoustic enclosure as per CPCB norms IV 415 volts 250 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self-excited self-regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following complete all as specified and as directed by the Engineer-in-Charge: (A) Alternator: Standard design alternator rated at 250 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 Phase, 4 Wire, 415 Volts, 50 Hz, 1500 RPM, self-excited self-regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/-1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation within +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS-4722. (i) Insulation class: 'H‘ (ii) Temperature rise Class: 'H‘ (iii) Excitation: Self Excited (iv) Regulation performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5% v) Frequency regulation +/- 1% (B) Diesel Engine: Adequate capacity of Diesel engine as approved by GE basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by
accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under: (i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust System complete with exhaust piping of suitable size with MS pipe light grade up to & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold, Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. (vi) Lubricating Oil System: Lubricating oil filter and lubricating oil pump (vii) Air Intake System: Air intake Manifold and air cleaner dry type (viii) Governor: Electronic Governor (ix) Starting System: Electric Self-starter with maintenance free battery including battery charging alternator (x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self-starter to the battery terminals complete with initial charge and initial fill of electrolyte all as
specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, Lubricating oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel (xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant Temperature indicator, Battery volt display. (xii) Safety Controls: Engine low lubricating oil pressure high water Temperature and over speeding of engine. (xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling. (xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms (xvi) Fuel Tank: Additional fuel tank of capacity to suit daily service fuel tank made out of 3mm thick (10 G) HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the acoustic enclosure. (xvi) MS pipe line to and from the fuel tank to the DG set. (C) AMF Panel: Factory made outdoor type control cubical made out of CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 250 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 pole ACB/MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, battery voltage, etc.
LIFTS:
Design supply, install testing & commissioning passengers lift, speed 1.5 metre/sec, lift with single speed motor 415 Volts, 3 Phase, AC supply, 50 Hz conforming to IS 14665, suitable to serve S+13 upper floors carry 13 passengers (884 Kg) with AC Variable Voltage & Variable Frequency drive (VVVF Drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (Electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (03 Nos. one each in car, machine room & near ground floor landing door) complete all as specified and as directed by the Engineer-in-Charge.
Design, supply, install, testing & commissioning firemen lift (1020 Kg), speed 1.5 metre/sec with single speed motor, 415 Volts, 3 Phase, AC supply, 50 Hz conforming to IS-14665 and as amended, suitable to serve S+13 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF Drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (Electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (03 Nos. one each in car, machine room & near ground floor landing door) complete all as specified and as directed by the Engineer-in-Charge.
S&F galvanised iron strip of 32x6mm size with saddles and fixing screws etc. for wall conductors connected with equipment and above ground (Proper insulation should be provided between the strip and walls) complete all as specified and as directed by the Engineer-in-Charge.
ARBORICULTURE:
Supply and planting Ashoka plant including filling the plantation pit of size 60x60x60cm with approved mixture of fertiliser soil (Sweet soil) and manure all as specified in the relevant PS clause, using pesticides of approved quality, including earth work and construction basin around the plant with excavated soil for stagnation of water and mixing the manure from time to time as required etc. complete all as specified and as directed by the Engineer-in-Charge.
Supply and planting Royal Palm tree including filling the plantation pit of size 60x60x60cm with approved mixture of fertiliser soil (Sweet soil) and manure all as specified in the relevant PS clause, using pesticides of approved quality, including earth work and construction basin around the plant with excavated soil for stagnation of water and mixing the manure from time to time as required etc. complete all as specified and as directed by the Engineer-in-Charge.
Supply and planting Neem tree including filling the plantation pit of size 60x60x60cm with approved mixture of fertiliser soil (Sweet soil) and manure all as specified in the relevant PS clause, using pesticides of approved quality, including earth work and construction basin around the plant with excavated soil for stagnation of water and mixing the manure from time to time as required etc. complete all as specified and as directed by the Engineer-in-Charge.
Supply and planting Jamun/Ravi tree including filling the plantation pit of size 60x60x60cm with approved mixture of fertiliser soil (Sweet soil) and manure all as specified in the relevant PS clause, using pesticides of approved quality, including earth work and construction basin around the plant with excavated soil for stagnation of water and mixing the manure from time to time as required etc. complete all as specified and as directed by the Engineer-in-Charge.
Supply and plant Korean carpet grass preparation of earth to required depth using pesticides and manures complete all as specified and as directed by the Engineer-in-Charge. Note for Item Nos.151 to 155: Supply only fertile earth, vermi compost etc. will be measured separately.
Supply only approved good quality fertile earth suitable for carpet grass all as specified.
Supply only approved vermi compost of the best quality all as specified.
SCHEDULE 'A' PART-XVI: Outsourcing Services for Operation of Lifts for the First Year of the two year Defect Liability Period:
Outsourcing of services for operaion of passenger lifts (8 Nos. i.e. 6 Nos. Passenger Lifts & 2 Nos. Firemen Lifts) any type and make to serve S+13 floors, during First Year of the two year Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including sunday & holidays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge (Shift Details: 365 Days x 1 Building x 2 Shifts x 2 Operators=1460 Shifts).
SCHEDULE 'A' PART-XVII: Outsourcing Services for Operation of Lifts for the Second Year of the two year Defect Liability Period:
Outsourcing of services for operaion of passenger lifts (8 Nos. i.e. 6 Nos. Passenger Lifts & 2 Nos. Firemen Lifts) any type and make to serve S+13 floors, during Second Year of the two year Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including sunday & holidays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge (Shift Details: 365 Days x 1 Building x 2 Shifts x 2 Operators=1460 Shifts).
SCHEDULE 'A' PART-XVIII: Outsourcing Services for Operation of Lifts and Comprehensive maintenance of Lifts for the First Year after Defect Liability Period:
Outsourcing of services for operaion of passenger lifts (8 Nos. i.e. 6 Nos. Passenger Lifts & 2 Nos. Firemen Lifts) any type and make to serve S+13 floors, during First Year after expiry of Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including sunday & holidays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge (Shift Details: 365 Days x 1 Building x 2 Shifts x 2 Operators=1460 Shifts).
Comprehensive mainenance of passenger lift, 6 Nos., with capacity of 13 passengers (884 Kg) to serve S+13 floors complete including ARD and all connected components of lift during First Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
Comprehensive mainenance of fireman lift, 2 Nos., with capacity of 1020 Kg to serve S+13 floors complete including ARD and all connected components of lift during First Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
SCHEDULE 'A' PART-XIX: Outsourcing Services for Operation of Lifts and Comprehensive maintenance of Lifts for the Second Year after Defect Liability Period:
Outsourcing of services for operaion of passenger lifts (8 Nos. i.e. 6 Nos. Passenger Lifts & 2 Nos. Firemen Lifts) any type and make to serve S+13 floors, during Second Year after expiry of Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including sunday & holidays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge (Shift Details: 365 Days x 1 Building x 2 Shifts x 2 Operators=1460 Shifts).
Comprehensive mainenance of passenger lift, 6 Nos., with capacity of 13 passengers (884 Kg) to serve S+13 floors complete including ARD and all connected components of lift during Second Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
Comprehensive mainenance of fireman lift, 2 Nos., with capacity of 1020 Kg to serve S+13 floors complete including ARD and all connected components of lift during Second Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
SCHEDULE 'A' PART-XX: Outsourcing Services for Operation of Lifts and Comprehensive maintenance of Lifts for the Third Year after Defect Liability Period:
Outsourcing of services for operaion of passenger lifts (8 Nos. i.e. 6 Nos. Passenger Lifts & 2 Nos. Firemen Lifts) any type and make to serve S+13 floors, during Third Year after expiry of Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including sunday & holidays including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed by the Engineer-in-Charge (Shift Details: 365 Days x 1 Building x 2 Shifts x 2 Operators=1460 Shifts).
Comprehensive mainenance of passenger lift, 6 Nos., with capacity of 13 passengers (884 Kg) to serve S+13 floors complete including ARD and all connected components of lift during Third Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
Comprehensive mainenance of fireman lift, 2 Nos., with capacity of 1020 Kg to serve S+13 floors complete including ARD and all connected components of lift during Third Year after expiry of Defect Liability Period complete all as specified and as directed by the Engineer-in-Charge.
Notes for Outsourcing Services Items: (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift shall be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non-function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 5 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair/replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure house keeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code: The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. “Name of the firm and designation” on front and on the back of the T-shirt along with protective clothing/gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. (xiii) The rate quoted by the bidders shall be deemed to be including Basic rate (Minimum Wages as notified by Government of India/ State Government/ Local body, whichever is higher), employers contribution towards Employees Provident Fund (EPF) liability, contribution towards Employees State Insurance Corporation (ESIC), contribution towards Bonus. Overhead and profit and labour welfare cess (LWC) as applicable depending upon the manpower requirement. This will create onus on the Bidders to applicable depending upon the man power requirement. This will create onus on the bidders to ascertain the relevant rates and quote accordingly. The rates quoted shall be inclusive of all taxes, cess, levies are applicable including GST. Note: The Manpower deployed shall be changed for every 11 months period. The rate quoted deemed to be inclusive for the same.
(xiii) The rate quoted by the bidders shall be deemed to be including Basic rate (Minimum Wages as notified by Government of India/State Government/Local body, whichever is higher), employers contribution towards Employees Provident Fund (EPF) liability, contribution towards Employees State Insurance Corporation (ESIC), contribution towards Bonus. Overhead and profit and labour welfare cess (LWC) as applicable depending upon the manpower requirement. This will create onus on the Bidders to applicable depending upon the man power requirement. This will create onus on the bidders to ascertain the relevant rates and quote accordingly. The rates quoted shall be inclusive of all taxes, cess, levies are applicable including GST. Note: The Manpower deployed shall be changed for every 11 months period. The rate quoted deemed to be inclusive for the same.
(viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personnel. The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work Order No I.
NJR Constructions Private Limited (BID ID -3233967)
Ramkrishy Infrastructure Private Limited (BID ID -3233158)
Som Projects Pvt. Ltd. (BID ID -3231548)
VRC Constructions (India) Limited (BID ID -3233898)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid