Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50 LAccepted-AOC | ₹50 L | L1 | Accepted-AOC L1 |
| 2 | L2₹50.6 L+₹57,500 (1.15%)Rejected-AOC | ₹50.6 L+₹57,500 (1.15%) | L2 | Rejected-AOC L2 |
| 3 | L3₹50.7 L+₹73,440 (1.47%)Rejected-AOC SIMBARGAON BATABARI KOKRAJHAR ASSAM PIN 783370 | KOKRAJHAR | ASSAM | 783370 | ₹50.7 L+₹73,440 (1.47%) | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Sri Sanswrang Bargayary L3 | Kemendra Kr Brahma L2 | M/S. L.N. DISTRIBUTORS L1 |
|---|---|---|---|---|---|---|
| 1.00 | 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. | 174.74 | Cum | 318 ₹55,567.32 | 315 ₹55,043.1 | 305.02 ₹53,299.19 Lowest |
| 2.00 | 16.12.1 Dry brick pitching half brick thick in drains including supply of bricks and preparing the
surface complete : | 223.17 | Sqm | 658 ₹1,46,847.83 | 655 ₹1,46,178.32 | 645.65 ₹1,44,091.65 Lowest |
| 3.00 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
1:4:8 (1 Cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size). | 16.85 | Cum | 6,728 ₹1,13,373.53 | 6,728 ₹1,13,373.53 | 6,726.68 ₹1,13,351.28 Lowest |
| 4.00 | 5.22 Steel reinforcement for R... Work including straitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level.
5.22.6. TMT bar Fe500D or more.
5.22.1 Mild steel and Medium Tensile steel bars. | 7,979.15 | Kg | 98 ₹7,81,956.7 | 98 ₹7,81,956.7 | 94.58 ₹7,54,668.01 Lowest |
| 5.00 | 5.9 Centering and shuttering including strutting, propping etc end removal of the same...5.9.1. Foundation Footing, base of column etc. For mass concrete.
5.9.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. | 187.01 | Sqm | 328 ₹61,339.28 | 328 ₹61,339.28 | 327.45 ₹61,236.42 Lowest |
| 6.00 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. | 205.5 | Sqm | 648 ₹1,33,164 | 648 ₹1,33,164 | 646.88 ₹1,32,933.84 Lowest |
| 7.00 | 5.9.6 Columns, Pillars, Posts & Strut. | 376.06 | Sqm | 858 ₹3,22,663.77 | 856 ₹3,21,911.64 | 855.18 ₹3,21,603.27 Lowest |
| 8.00 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.3 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal. | 65.76 | Cum | 8,448.85 ₹5,55,596.38 Lowest | 8,448.85 ₹5,55,596.38 Lowest | 8,448.85 ₹5,55,596.38 Lowest |
| 9.00 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size). | 36.99 | Cum | 10,830.07 ₹4,00,604.29 Lowest | 10,830.07 ₹4,00,604.29 Lowest | 10,830.07 ₹4,00,604.29 Lowest |
| 10.00 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand). | 676.92 | Sqm | 1,082.52 ₹7,32,776.19 Lowest | 1,082.52 ₹7,32,776.19 Lowest | 1,082.52 ₹7,32,776.19 Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
28 Jul 2025, 2:00 pmClosed
The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Assam.
Const. of Boundary Wall for proposed ITI at Hatigor Udalguri District.
2025_BTC_45404_3
ACE-35/TECH/UDL(RB)/IFB/18-19
Open Tender
Civil Works
Item Rate
180 days
Udalguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹1 L
Yes
19 Sept 2025
7 Jul 2025
28 Jul 2025
7 Jul 2025
28 Jul 2025
7 Jul 2025
7 Jul 2025 - 28 Jul 2025
Amount
2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
16.12.1 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size).
5.22 Steel reinforcement for R... Work including straitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6. TMT bar Fe500D or more. 5.22.1 Mild steel and Medium Tensile steel bars.
5.9 Centering and shuttering including strutting, propping etc end removal of the same...5.9.1. Foundation Footing, base of column etc. For mass concrete. 5.9.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Posts & Strut.
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal.
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand).
13.5 15 mm thick cement plaster in single coat on rough side of single or half brick wall. 13.5.1. 1:4.(1 Cement: 4 Coarse Sand) c) In cement mortar 1:5
13.43 Applying one coat of water thinable cement primer of approved brand and manufacture on wall surfaces. 13.43.1.Water thinnable cement primer.
13.44 Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1. New work (Two or More coat @ 3.84 Kg/10m2
IRON GATE WITH RCC POST 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming o fbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a). Brick on flat soling.
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size)
5.22 Steel reinforcement for R... Work including straitaning, leaning utting and bending to proper shape planing in position and binding up to plinth level. 5.22.6. TMT bar Fe500D or more. 5.22.1 Mild steel and Medium Tensile steel bars. (i) TMT Corrosion resistant steel (CRS) reinforcement bar.
5.9 Centering and shuttering including strutting, propping etc end removal of the same...5.9.1. Foundation Footing, base of column etc. For mass concrete. 5.9.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
5.9.6 Columns, Pillars, Posts & Strut
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size)
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
13.14 15 mm cement plaster 1:2 (1 cement: 2 stone dust) on the rough side of single or half brick wall.
13.43 Applying one coat of water thinable cement primer of approved brand and manufacture on wall surfaces. 13.43.1.Water thinnable cement primer.
13.44 Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1.New work (Two or More coat @ 3.84 Kg/10m2
13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets.
CONSTRUCTION OF GATE 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 20 mm nominal size)
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.9 Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
13.5 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.2 1:6 (1 cement: 6 coarse sand).
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
APPROACH ROAD 2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.3 Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1⁄2 tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m 2.3.1 All kinds of soil
16.78 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge. 16.78.2 With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value- 25
16.43 Providing and laying.design mix cement concrete of M- 30 grade, in roads/taxi tracks/runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/camber.
Kemendra Kr Brahma (BID ID -273442)
Sri Sanswrang Bargayary (BID ID -273445)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .